Systeem- en Project beschrijving Project Buitenland Inkomend/Arbitrage tenbehoevevande Algemene Bank Nederland N.V.
Uitgegevendoor: Philips-Electrologica Nederland N.V. Juli1972 Projectleider: Ir. R.F.M.Nitzsche Systeem Ingenieurs: Ir. A.v. Dort C.B. Leeuwenburg Ir.A. Paalman C.C.H.v.Puffelen J.L.C.N.M.Suys
data systems
PBA N0RM-BERICHT
...„!---------------- ———— - I-- .... I I I IN I I CODE: I OMSCHRYVING: I I I
I I I I I I I I I I I I I I I I I I I I 1 I II I I I I I I I I I I I I I I I • I I I I
1 ...... i ...... 1 1 I I
I 4 I
I RESP.I UIT I I 1 I ——— 1 ————— i ————— I I I 81 ENTRY: DE START VAN I I I I I DE TRANSAKTIE I I 2)1 I( EXTRA OP DE LYN I 141 I RESPONSE I 120 I I UITVOER VAN HET SCHA I I I I I BL00N I 0*1 I* LEZEN VAN SCHABL00N I
3 I 4 I
NAAM PARTY 1 TM 3 LEZEN PARTY 1 TM 3
I I 6 I 2 I 3 I 1
1 I 6 I 2 I 1
I
6 I
2 I 3 I I
4 I
1 6 2 3
I I I I
INGEVULD SCHABL00N EXTRA OP DE LYN RESPONSE 2 BEVESTIGING
LXTKA OP DE LYN
RESPONSE 3 PARTY 4 (VOOR DE SYN.)
LEZEN PARTY 4
BEVESTIGING EXTRA OP DE LYN RESPONSE 4 EINDANTW00RD
TOTAAL:
SNELHEDEN: TYDEN:
TOTAAL TYD:
5% VOOR F0UTEN: AANL00P EN UITL00PX
TOTAAL: AANTAL RESPONSES
EXTRA TEKENS OP DE LYN
TOTAAL AANTAL OP DE LYN
3ERICHTLENGTE NETT0 INPUT REPETITION TIME TRANSAKTIETYD BY 70%
T.
I 92 I 1 I 46)1 I( 141 I I I I 4*1 I* I I 4 I I I 2)1 I< 4 I I I I I I I I I 2*1 I* I I 4 I I I 2)1 1C 4 I I I I I I -I16 I 108 I I 6*1 1C 52)1* 1 I 2.0 I
90
25 505 0
I0 I 22 I 54 I I I- ———— j. ....-! ...... I 76.0 I I
I I II
3.8 3.0
I I I 82.8 I I s:S3SS38S=:=Z = 8S3SSSaS I I 4.0 I : 52.0 I : I 665.0 * I 166.3 : 20.7 I : I 118.3 : I •I
B-6-5
Explanation of some words on B-6-5 IN = Number of characters ( ) = Extra characters on the line RESP.= Response time * * = Extra wait time UIT = Number of characters output TOTAAL SNELHEDEN TIJDEN TOTAALTIJD 5% VOOR FOUTEN AANLOOP EN UITLOOP
I I I 270 I
TOTAL SPEEDS TIMES TOTALTIME 5% ERROR RECOVERY START- AND FINISH
Philips Data Systems Nederland B.V. page:
Sociale Verzekerings Bank Bijlage B
doc.numb.:
Hoofdstuk 2 i Mutatie ie stroom Verheterina
date: author:
Human actions
04-04-1978 J. Suijs
Dialogue scheme Transactionname;
2.1.1.
prec.doc. :
part: Mutatie l e stroom Verbetering Machine actions Transport
Opzoeken van de gegevens van deze KB "gerechtigde"
Invoer Identifikatie Lezen van het scherm en stukken ervan verbeteren Verbeteringen aanbrengen en versturen einde transaktie
Intrinsieke screening Relatie screening Indien fouten dan deze melden Akkoord melding
Opmerking; op de hiernavolgende bladen otaan enige afkortingen: : Dit is de parameterkode, die aangeeft wat P-code voor soort parameter bedoeld wordt. Op blad 2.3.1. staan ze omschreven met daarachter de totaalwaarden. Prob.
Dit is de Probability (de kans), dat dit element voorkomt. (tussen 0 en 1) 0.5= 50% 1 = 100% Als de kans niet 1 is, volgt nog een regel (met sterretjes), waar de gemiddelde waarde bij kans 1 is weeryegeven.
E(x)
Dit is de gemiddelde waarde.
VAR(x)
Dit is de variantie (kwadraat van de standaardafwijking).
Philips Data Systems Nederland B.V. page:
3
Sociale Verzekerings Bank Bijlage B Hoofdstuk 2: Mutatie l e stroom Verbetering Par 2:Detailed Transaction Scheme Transactionname: Mutat i e l e stroom Verbetering Prob. p-code Consent
-— -
•
Invoer transaktiesoort Invoer identif ikatie geboortedatum 6 3 volgnummer 1 checkdigit 1 funktietoets 11 Transport Term naar CPU transaktiesoort en identif ikatie Dialoog response Response eenheden 6.5 + 0.5 bestandsraadplegingen Transport CPU naar Term. 7 kopregels 3 kinderregels + 1 6 sluitregels ieder ongeveer 80 tekens Weergave op het beeldscherm Lezen van het scherm leessnelheid ca. 20 tekens per seconde Wijziging van ca. 45 toetsen ± 15 Transport wijziging Af sluitresponse Response eenheden; geschat wordt een equivalent van 6 ctiscaccessen + 1 In 5% van de gevallen volgen een of meerdere van de 175 foutmeldingen. Transport 30+10 Weergave van de f outmelding Korrektie aanbrengen
Transport korrektie Af sluitresponse Response eenheden ^oonieuw screening^
2.2.1 .
prec.doc. :
doc. numb. : 04-04-1978 date: author :
J. Suijs part: ± E(x)
VAR(x) »
1
1
1
0
1
1
11
0
2 5
1 1
11 1
0 0
6
1
3 4
1
12
1
32
36
1 2 7
1 1 1
45 45 1
225 225 0
8
1
8
3
0.05 1.00 0.05 1.00 0.05 1.00 0.05 1.00 0.05 1.00 0.05 1.00
XXX
4
XXX
1
XXX
2
XXX
7
XXX
8
XXX
6.5
1280 1280
30 1.5 30 1.5 45 2.25 45 2.25 1 0.05 8 ___ Da4—— .
0.25
80
——SO __ .
___ 0^5..
100 47.75 100 47.75 225 107.44 225 107.44 0 0.05 0.5 3^07
Philips Data Systems Nederland B.V. Pa9<;
Sociale Verzekerings Bank Bijlage B
.J
date: author :
04-04-1978
J. Suijs part: ^
Transactionname: Mutat i e l e stroom Verbetering P-code
Prob.
3 4
1 1
E(x)
10 10
Einde transaktie
.•
I
doc. numb. :
Par 2: Detailed Transaction Scheme
Akkoord bericht retour 10 posities + 5 weergave ervan
;•
prec.doc. :
Hoofdstuk 2: Mutatie l e stroom Verbeterina
Corrrr.ent
2.2.2.
•
•~\
«,
VAR(x)
25 25
4
(
I
Philips Data Systems Nederland B.V. page :
Sociale Verzekerings Bank Bijlage B Hoofdstuk 2: Mutatie l e stroom Verbetering
2.3.1.
prec.doc. :
doc. numb. :
date: 04-04-1978 author:
Rar 3 : Transaction Summary Transactionname: Pcod,
J. Suijs
Mutaite l e stroom Verbetering
Parameter
E(x)
,
1
Inputlength
2
Transportlength input
3
Transport length output
4 5 6
1291.5 Outputlength 1 Dialogue response 6.5 Dialogue responseunits 1.05 Closure response 8.4 Closure response-units
7 8
dimension
59.25 characters
58.25 characters 1291.5 characters
2.5
characters responses units responses units seconds
11 12 13 14
Start- and End-times Wait- and Think-times
Type speed Recovery percentage/ 100
2 char. /sec. 0.05 factor X)
15
(Minimum Input Repetition time Effectiveness
0
seconds
0.7
factor 1}
16
32
seconds
VAR(x)
332.44 322.44
152.75 152.75 0 0.25 0.05
3.57 1 36 1 0
0.1
percentage/ 100 21 22 23
Transport delay time Unit time (responses)
1)
The factor is always between 0 and 1
Printing speed
0.4 seconds 0-3 seconds 400 char. /sec. (4800 bps 70% effectief)
0.1 0.1 400
Opmerkingen: de transportti jd is als konstante meegenomen, ongeacht de berichtlengte. De printsnelheid zelf zorgt voor de noodzakeli jke "vertraagde" weergave. Omdat bij muteren niet "blind" getypt wordt, nemen we aan 2 tekens per seconde. (van overzichtelijk formulier met voornamelijk alpha-informatie en weinig numeriek)
Philips Data Systems Nederland B.V. page :
2.4.1.
Sociale Verzekerings Bank Bijlage B
prec.doc. :
Hoofdstuk 2: Mutatie l e stroom Verbetering
date
doc.numb.:
J. Suijs
Par 4:Transaction Terminal Time Transactionname:
04-04-1978
author:
Mutatie l e stroom Verbetering
Tiir.e element
VAR(x)
Second
Input time
(quotient of Inputlength
29.63
302.52
32.00
36.00
0.82
0.43
4.47
22.55
3.23
0.03
Subtotal Recovery time Start and End time
70.14
361.52
3.51 2.50
0.90 1.00
Total
76.15
363.43
and Type speed)
Wait- and Think time Transport time
(product of number of Responses and Transport delay time) Processing time
(product of Response-units and Unit time)
Printing time (quotient of Outputlength and Printing speed)
The Standard Deviation is: 19.06
Philips Data Systems Nederland B.V. page: 7.4.7.
Sociale Verzekerings Bank Bijlage B
prec.doc. : doc.numb.:
Hoofdstuk 2: Mutatie l e stroom Verbetering E&r4:Transaction Terminal Time (continued) Transactionname:
date:
04-04^1978
author:
J. Suijs
Mutatie r6 stroom Verbetering
Time element
Total time
Input Repetition time (quotient of Total time and the number of responses)
Normal Transaction time (quotient of Total time and effectiveness percentage)
seconds
VAR(x)
76.15
363.43
37.15
102.90
103.79
3156.91
characters
VAR(x)
Netto messagelength input (quotient of Inputlength and the number of Responses)
28.41
88.71
Netto messagelength output (quotient of Outputlength and the number of Responses)
630.00
4758.54
! Estimations ! (to be checked)
seconds
VAR(x)
Average Response
2.58
5.47
Dialoaue Response
2.35
4.35
Closure Response
2.80
6.79
3.
CONSTRUCTION OF TRANSACTIONS
1 1
Model of a transaction scheme. Human actions and operations After taking up and reading a form the kind of transaction and debtor-number is keyed. Reading (check) the name.
Data trans port
Machine processing
Interpretation and storage of the da ta; searching to the name and re turning it.
Keying the first or der line.
Interpretation and storage; giving permission for next line, etc.
Keying next order line.
Permission, etc.
etc.
Comparison of the total with the sto red data; if cor rect, acceptance of the order follows by passing it on to another system-com ponent. Finally a reference number be printed.
Keying a total
O -P
•< X
Start of a (possibly another kind) trans action.
- 28 -
;
5-
PERSONAL PARAMETERS.
Schedule of speeds of keying 4 to 5 charac ters per sec.
^ tc 3 charac ters per sec.
clear
not clear
clear
not clear
3,8 3,6
3,4 3,2
2,8 2,6 2,3 2,1
2,2 2,2 2,1 2,0
1,9 1,7 1,6
'.Vith looking Alpha Alphanum. * 2/1 Alphanum. - 1/2 Numeric
2,3 2,0 1,8 1,5
1,6 1,4 1,2 1,0
1,6 1,5 1,3 1,2
1,3 1,1 1,0 0,8
'.Vith looking and de ciding Alpha Alphanum. = 2/1 Alphanum. = 1/2 Numeric
1,7 1,5 1,2 1,0
1,3 1,1 0,9 0,8
1,3 1,1 1,0 0,9
1,0 0,9 0,8
Blind Alpha Alphanum . = 2/1 Alphanum. = 1/2 Numeric
1,5
0,7
3.
CONSTRUCTION OF TRANSACTIONS.
The A.P.M.-parameters.
Problem APPLICATION 'INFORMATION INFORMATION
MAN TERMINAL
COMPUTER
Personal parameters
Machine parameters
1 . Lead and run out. 2. Times to con 2. Transportsider and length in waiting ti put. mes 3» Speed of key 3. Transporting and length out touching. put. Error correc 4. Outputlength. tion per centage. Minimum input 5. Number of of repeti responses tion time. 6. Effective 6. Number of workingresponsehours . items.
1. Transport de lay. 2. Response time per unit.
Application
parameters
1. Inputlength.
3. Print speed.