STUDI KASUS : Implementasi Power line Communivation :’ REGULASI, DESAIN DAN ANALISA PEMANFAATAN JARINGAN TENAGA LISTRIK PT.PLN (PERSERO)’ DR IR Iwan Krisnadi MBA (NIDN: 0010085204)
Program Studi
Magister Teknik Elektro
Kode Kelas : B21546BA
IMPLEMENTASI POWER LINE COMMUNICATION REGULASI, DESAIN DAN ANALISA PEMANFAATAN JARINGAN TENAGA LISTRIK PT.PLN (PERSERO)
Kelompok 6 : Muhamad Yusuf; Ahmad Miftahudin; Zuansah Rachmat Munggaran; Slamet Riyanto; Norma Liaty Fithri; Nelza Oktarini
Dosen
: DR Ir IwanKrisnadi MBA
Outline
Latar Belakang Power Line Communication
Regulasi
Analisa SWOT
Kesimpulan
LATAR BELAKANG STUDI KASUS IMPLEMNTASI POWER LINE COMMUNICATION (PLC)
BACKGROUND
KEBUTUHAN AKAN TELEKOMUNIKASI BERKEMBANG PESAT
INTERNET OF THINGS
DIBUTUHKANNYA INVESTASI DAN INFRASTUKTUR YANG MEMADAI
MAIN PROBLEM
COVERAGE DARI INFRASTRUKTUR YANG ADA
PEMBANGUNAN INFRASTRUKTUR PROVIDER
MODAL PARA PELAKU BISNIS TELEKOMUNIKASI
FOCUS ISSUE
ADAKAH TEKNOLOGI SISTEM TELEKOMUNIKASI ALTERNATIF ?
BAGAIMANA PERANCANGAN SISTEM ALTERNATIF YANG BARU?
BAGAIMANA ANALISA NYA?
Power Line Communication (PLC) STUDI KASUS IMPLEMNTASI POWER LINE COMMUNICATION (PLC)
Powerline Communications (PLC) Apa yang disebut dengan PLC ?
9
PLC adalah suatu cara dimana sistem jaringan telekomunikasi untuk menyalurkan internet maupun telepon dengan memanfaatkan jaringan penghantar listrik (PLN)
10
11
12 DPLC
DP/DISTRIBUTION POINT
SEKUNDER DP
SEKUNDER Kabel Tegangan Rendah
DP GARDU DISTRIBUSI
RK
MULTIPAIR CABLE /PRIMER DW/DROP WIRE
SENTRAL TELEPON
E1
DP
13
FO BACKBONE DI PULAU JAWA
14
SLAYA MTWAR
CLGON
JAWA
TGRNG BKASI
CKUPA SRANG
JAKARTA
KSBRU GNDUL CBATU CIBNG
JTLHR
CRATA
AJWNG
SRAGI
PDLRG
BGBRU
PRKAN
PKLON KRPYK
GRESIK
MADURA
WLERI
KMJNG CNJUR
TBROK
KBSEN
BANDUNG
SGLNG
SEMARANG
BDSLN
SGMDU TNDES
UNGAR KLBKL
JELOK
SWHAN
UWRU KRIAN
SURABAYA
BNGIL
YOGJA
GRATI
PITON
KLTEN
STBDO
KDBRU
BALI LMJNG
GLNUK JMBER BWNGI NGARA
KAPAL GNYAR
PSGRN NSDUA
JARINGAN BACKBONE SERAT OPTIK ICON+ / PLN DI JAWA-BALI
SANUR
PLUSTM architecture
15
Telephony over power lines
16
(Domestic Example)
Class 5 Softswitch
PSTN (Provider 1 NW)
Billing Provisioning
PSTN (Provider 2 NW) Class – 5 Switch
PU IP Backbone Gateway (Provider 2)
Gateway (Provider 1) VAS
Customer (Provider 1)
Class – 5/4 Switch
Concentrator
CuPLUS
Power line
TelPLUS
Medium Voltage solution
Medium Voltage point to point link
Medium voltage chain/ring
USA Experience
In the US two cases:
Underground/pad mounted transformers – Insolated line inside closed enclosure
Overhead transformers external non isolated line
USA Experience
Medium Voltage solution Use of coupler in order to inject signal, without direct connection to high voltage Main.net’s tests in USA has proven that the CtPLUS units are capable of communicating over medium and low voltage both to other Transformer units and to in-home units Implementing Main.net’s point-to-multi point technology over Medium and Low Voltage Fully integrated in the PLC system and network management
Main.net’s MvPLUS
MvPLUS unit
Small
Special Coupler Interface
Based on the same technology as the LV solution
Fully monitored by NmPLUS management system
Inductive Couplers For Isolated and non-isolated cables
Capacitive Couplers
STUDI KASUS POWER LINE COMMUNICATION
Memanfaatkan kabel konduktor sebagai media transfer data
Menyisipkan sinyal dengan rentang 500-600 Mhz
Menggunakan Modem Broadband over power line
Kecepatan sampai 45 Mbps
Konversi dari arus AC signal analog ke digital
DIAGRAM KERJA PLC
HARDWARE
PERANGKAT MODULASI PLC
CONDITIONING UNIT
PERIPHERAL
1.
BASE STATION
2.
COUPLER CIRCUIT
3.
REPEATER
PLAN AND DESIGN
Regulasi STUDI KASUS IMPLEMNTASI POWER LINE COMMUNICATION (PLC)
REGULASI
UU NO 36 TAHUN 1999
UU NO 5 TAHUN 2013
Analisa SWOT STUDI KASUS IMPLEMNTASI POWER LINE COMMUNICATION (PLC)
ANALISA SWOT
STRENGTH
OPPURTUNITY
WEAKNESS
TREAT
ANALISA SWOT
STRENGTH 1.
PLC memiliki kemampuan yang cukup baik dalam transfer data
2.
Didukung UU no 36 tahun 1999
3.
Didukung Lampiran PM KOMINFO pada desain PLC
4.
Biaya 1/3 Fixed line
5.
Modal investasi tidak terlalu besar dengan existing jaringan PLN
ANALISA SWOT Oppurtunity
Lebih dari 80.000 kms Saluran Udara, Saluran Kabel Tanah, dan Saluran Kabel Laut
Potensi 70 JUTA pelanggan dengan kWh Meter Terpasang
Lebih dari 1000 Gardu Induk dan 40.000 Gardu Distribusi
Coverage dari sabang sampai merauke, Laut, pesisir dan pedalaman
Dibutuhkan sebagai alternatif untuk menjawab kebutuhan telekomunikasi
ANALISA SWOT
TREAT
Pelaku bisnis yang memiliki jabatan di pemerintahan
ANALISA SWOT WEAKNESS PM KOMINFO NO 5 TAHUN 2013 LAMPIRAN BAB II KOMODITI KELOMPOK I POINT D
Kesimpulan STUDI KASUS IMPLEMNTASI POWER LINE COMMUNICATION (PLC)
KESIMPULAN
PLC cocok diimplementasikan di PLN
Dapat menjawab tantangan pada focus issue
Secara aturan modulator, basestation, BPL, Bbpl, Periperal
Untuk dapat terealisasi harus dirubah regulasi pada aturan PM KOMINFO karena A3CS PLN tidak termasuk pendukung jaringan telekomunikasi