ORT-10
Electronic modulating room thermostat for OpenTherm appliances Installation and User Guide Danfoss Heating
Index
Index GB Specification..................................................................................... 3-4 Positioning & Installation...................................................................5 Wiring................................................................................................ 6-7 Mounting..............................................................................................8 Locking & Limiting..................................................................................9 User Instructions............................................................................. 10-11
NL Technische Specificaties.............................................................12-13 Positionering..................................................................................... 14 Installatie........................................................................................... 15 Bedrading.....................................................................................15-16 Montage............................................................................................. 17 Blokkeren & Begrenzen...................................................................... 18 Gebruikers handleiding............................................................... 19-20
2
Specification Code Number Temperature range
087N773800 8-30°C
Maximum ambient temperature
45°C
Control type
P+I
OpenTherm software version
2.3
Domestic hot water keep hot feature
•
Holiday mode
•
ID 14 low load control Thermostat output Construction IP rating Supply voltage Wiring, non-polarised 2 wire bus Control pollution situation
Specification
GB NL
Specifications
• Data EN60730-2-9 IP20 24V DC from boiler • Degree 2
Ball hardness test
75°C
Dimensions (mm)
86 high x 85 wide x 42 deep
3
Specification
GB NL Specification ERP Class The products represented within this document are classified according to, and allow completion of, the Energy Related Product (ErP) Directive System Package fiche and the ErP system data label. ErP Labelling obligation is applicable from 26th September 2015. ErP Class
V
ErP Class 5 Product
4
Product Function and ErP Description Modulating Room Thermostat, for use with modulating heaters An electronic room thermostat that varies the flow temperature of the water leaving the heater dependent upon measured room temperature deviation from room thermostat set point. Control is achieved by modulating the output of the heater.
Additional efficiency gain
3%
ORT-10
GB NL Installation
Positioning & Installation
5
Wiring
GB NL Wiring
6
1.
For surface mounted wiring, cutouts are provided on the backplate to enable correct positioning of the cable.
2.
For recessed wiring, cabling can be connected as in diagram 2.
ORT-10
A
B
3
4
Set-back connections in ORT-10
Wiring
OpenTherm connections in ORT- 10
GB NL
Wires can be crossed
OpenTherm connections in boiler
O
O
External volt free contactor/ switch
Important - To avoid damage to Boiler and Thermostat, connect only to OpenTherm connections on boiler, do not connect to any other power source. By connecting a volt free switch over terminals 3 + 4 you can provide an external override to enable a forced 8°C frost protection + HW store off condition.
7
Mounting
GB NL Mounting 1.
2.
3.
8
Locking and Limiting
GB NL
1. Before removing dial, turn until setting 1 aligns with reference mark on front case. 2. Remove dial, lock or limit as required (see note below). 3. Replace dial, ensuring setting 1 aligns with reference mark on case.
Locking and Limiting
Important Note: If Holiday Function
is required DO NOT adjust lower limit.
9
User Instructions
GB NL User Instructions Unlike normal room thermostats, the ORT-10 varies the heat output of Setting the Opentherm condensing boiler to which it is connected. This adds Dial to the boiler efficiency significantly by ensuring that the boiler keeps in economical condensing mode whenever possible. Daily use is as easy as setting the thermostat dial to the required setting, the advanced electronics and software within the thermostat establish two-way communication with the Opentherm boiler to ensure optimal operation.
10
In addition to the room temperature control, the ORT-10 also incorporates a feature which, dependant on boiler type, allows the domestic hot water store in the boiler to be kept hot or to be turned off, for example when on holiday. To select hot water and heating off, simply turn the thermostat dial to the holiday position or press the button if you still wish to control the central heating only.
Settings
GB NL
Room Temperature Setting 10 – 30°C: Set dial to required room temperature, domestic hot water store in boiler is kept hot*. The LCD will flash to show set point and then display room temperature.
User Instructions
Holiday Setting : Controls room temperature at 8°C, (frost setting), domestic hot water store in boiler is turned off. button: Pressing this switches off the boilers HW store*. Unit will display to confirm. *(This feature is dependant upon boiler type).
Indication Start-Up: When boiler is first turned on the LCD will flash for 20 seconds.
11
User Instructions
GB NL
12
Normal Operation: Flame symbol will be displayed whenever the boiler is firing. The bars to the right of the displayed temperature visually indicate the level of modulation at the boiler. 1 bar =25%, 2 bars = 50% etc. Holiday Mode: When thermostat is put into, or taken out of holiday setting the LCD will flash for 20 seconds. larm Mode: Should a fault occur with the boiler the LCD will A display Er (or Er + associated error code if boiler functions support) to warn of failure. For details of errors codes please consult your boiler manual.
Technische Specificaties Technische Specificaties Bestelnummer Temperatuurbereik
087N773800 8 - 30°C
Maximale omgevingstemperatuur
45°C
Regelprincipe
P+I
OpenTherm Protocol
2.3
Warm tapwater Comfort-functie
•
Warm tapwater Eco-functie (vakantie stand)
•
ID 14 regeling lage belasting Thermostaat output Fabrikagenorm Dichtheidsklasse Voedingsspanning Aansluiting: 2 draads, polariteit ongevoelig
•
Technische Specificaties
NL
OpenTherm Data EN60730-2-9 IP20 24V dc van ketel •
Emissiewaarde
Niveau 2
Afmetingen in mm (bxhxd)
85x86x42
13
Technische Specificaties
NL Technische Specificaties ErP-klasse De in dit document beschreven producten zijn geclassificeerd overeenkomstig de richtlijn voor energiegerelateerde producten (ErP) en stellen u in staat om zowel het datablad voor het systeempakket als het ErP-systeemlabel aan te maken. De ErP-labelverplichting gaat in op 26 september 2015. ErP-klasse
V
ErP Class 5 Product
14
Productfunctie en ErP-beschrijving Modulerende kamerthermostaat, voor gebruik met modulerende verwarmingen Een elektronische kamerthermostaat die de stromingstemperatuur van het water vanuit de verwarming varieert op basis van de gemeten afwijking van de kamertemperatuur ten opzichte van het setpoint van de kamerthermostaat. De regeling vindt plaats door het uitgangsvermogen van de verwarming te moduleren.
Extra rendement
3%
NL Positionering
Positionering
ORT-10
15
Installatie
NL Installatie
16
Bedrading 1.
Als de bekabeling via de onderzijde wordt aangebracht kan gebruik gemaakt worden van de afbreekbare doorgangen op de bodemplaat zoals afgebeeld in figuur 1.
2.
Als de bekabeling via de achterzijde wordt aangebracht kan gebruik gemaakt worden van de opening in de bodemplaat zoals afgebeeld in figuur 2.
Bedrading
NL
17
Bedrading
NL Bedrading OpenTherm aansluiting in ORT- 10
A
B
Draden mogen gewisseld worden
OpenTherm aansluiting in ketel
18
O
3
4
Aansluitklemmen t.b.v. extern (schakel)contact
Extern potentiaalvrij (schakel)contact
O
Belangrijk - Om schade aan ketel en thermostaat te voorkomen dient de thermostaat alleen op de OpenTherm aansluiting van de ketel te worden aangesloten. Door een extern potentiaalvrij (schakel)contact over de klemmen 3 + 4 aan te sluiten kan de thermostaat vergrendeld worden op een ruimtetemperatuur van 8°C en warm tapwater functie uitgeschakeld. De functie is hetzelfde als de instelling op (suitcase symbol here) met de instelknop.
Montage
NL 2.
Montage
1.
3.
19
Blokkeren & Begrenzen
NL Blokkeren & Begrenzen
20
1. Draai de instelknop op stand 1. 2. Verwijder de instelknop en blokkeer of begrens naar behoefte ( zie onderstaand schema). 3. Plaats de instelknop op stand 1 weer terug. Let op: Stel geen minimum begrenzing in als de Vakantie Stand nodig is.
Instelknop
Anders dan bij normale aan/uit thermostaten regelt de ORT-10 traploos de warmteafgifte van de OpenTherm ketel waarop hij is aangesloten. Dit draagt in hoge mate bij aan het ketelrendement door te zorgen dat de ketel zo lang mogelijk in HR (condenserend) bedrijf werkt.
Dagelijks gebruik is zeer eenvoudig door de instelknop van de thermostaat simpelweg op de gewenste temperatuur in te stellen. De geavanceerde elektronika en innovatieve software in de thermostaat verzorgen de twee-weg-communicatie met de OpenTherm ketel en verzekeren een optimale werking. Naast de comfortabele regeling van de ruimtetemperatuur heeft de ORT-10 ook functies t.b.v. de warm tapwater voorraad. Afhankelijk van het merk en type ketel kan de warm tapwater voorziening van de ketel in- en uitgeschakeld worden. Als u geen verwarming én geen warm tapwater voorraad wenst draait u de instelknop eenvoudig op de vakantiestand . Als u wel verwarming maar géén warm tapwater voorraad wenst drukt u op het knopje.
NL Gebruikers handleiding
Gebruikers handleiding
21
NL
Instellingen
Instellingen
Ruimtetemperatuur instelling 10 – 30°C: Zet de instelknop op de gewenste ruimtetemperatuur, tapwater voorraad wordt op temperatuur gehouden*. De display knippert als de gewenste temperatuur wordt ingesteld en geeft vervolgens, zonder te knipperen, de werkelijke ruimtetemperatuur weer. Vakantiestand : Regelt de ruimtetemperatuur op 8°C, (vorst beveiliging), warm tapwater uitgeschakeld*.
knopje: druk op dit knopje om de warm tapwater voorraad van de ketel uit te schakelen*. Op de display wordt het symbool weergegeven. *(Deze funktie is afhankelijk van het keteltype).
22
Opstarten: Na het inschakelen van de voedingsspanning van de ketel knippert de LCD gedurende 20 seconden. Normaal bedrijf: Als de thermostaat de ketel inschakelt wordt dit met een vlam symbool op de display weergegeven. De streepjes naast het vlamsymbool geven een indicatie over de modulatie van de ketel. 1 streepje =25%, 2 streepjes =50% etc.
NL Instellingen
LED-indicator
Vakantiestand: Wanneer de thermostaat op Vakantiestand wordt gezet knippert de LCD twee keer, bij terugzetten op normaal bedrijf een keer. Alarm functie: Mocht er een storing in de ketel zijn wordt dit op de display van de ORT-10 weergegeven met de aanduiding Er of Er+. Raadpleeg voor details over de storing de handleiding van uw ketel of uw installateur.
23
www.heating.danfoss.co.uk
24
Part No 25189 Issue 2 06/2015 (VIRKB17L)