EU bejelentett testület Notified body
ORSZÁGOS MÉRÉSÜGYI HIVATAL National Office of Measures, Hungary
H-1124 Budapest, Németvölgyi út 37-39 H-1535 Budapest Pf.: 919, fax (36)-1-3550598
Azonosítási szám: 1422 Identification number:
Ügyiratszám: TH-8401/4/2005 File number:
EK TÍPUSVIZSGÁLATI TANÚSÍTVÁNY EC Type-approval Certificate (TAC)
A 90/384/EGK irányelvet honosító 62/2004. (IV.24.) GKM rendelet alapján a következő EK Típusvizsgálati tanúsítványt adtuk ki. In accordance with the requirement of the 62/2004. (IV.24.) decree of the Minister of Economy and Transport implementing the Council Directive 90/384/EEC of the non-automatic weighing instruments, this certificate of EC type-approval has been issued.
Kérelmező: Issued to:
KONTINEX KFT H-6724 Szeged Pacsirta u. 7/A.
Megnevezés:
Nem-automatikus működésű mérleg emelőrendszer nélkül.
In respect of:
Non-automatic weighing instruments, without lever system.
Max 1 kg…120 t n ≤ 6000 Pontossági osztály / class: III vagy / or IIII Gyártó / Producer: KONTINEX KFT Típus / Type: KX-…-... Engedély száma:
TH-8401/4/2005
Approval number:
Érvényes:
2015. október. 21.
Valid until:
Oldalak száma:
6
Number of pages:
Az azonosításhoz szükséges információkat (fő adatok, funkciók, lezárás, stb.) és a típusvizsgálati feltételeket (ha ilyenek vannak) ezen tanúsítvány és annak részét képező melléklet tartalmazza. The necessary data (principal characteristics, functions, securing, etc.) for identification purposes and conditions (when applicable) are set out in this certificate and in the descriptive annex, which forms an integral part of this certificate.
Budapest,
............................................... Schmalhofer Károly aláírás / signature
ORSZÁGOS MÉRÉSÜGYI HIVATAL
Engedély száma: TH-8401/4/2005
National Office of Measures, Hungary
Approval number: page 2 of 6 pages
2/6 oldal 1 A mérőeszköz megnevezése és típusjele Nem-automatikus működésű elektromechanikus mérleg, típusjele KX-…-… a kiépítéstől függően. A korábbi (nemzeti) típusjelölési rendszer kereskedelmi jelzésként továbbra a is használatban van. 1 Name and the type of the instruments Non-automatic electromechanical weighing instruments, type KX-…-... depending on configuration. The former (national) type system remain in use as commercial marking.
2 A mérőeszköz leírása A típusnév három részből áll: ¾ alapjel: ¾ kiértékelő egység jele: ¾
teherfelvevő jele:
(KX), (01;01/Mxxx ; MIDI; DUAL; MT; MTT; MTC; EMX100/1xx; IQMx-y-z), (VSH; TS-GSX; LMG; RMGK).
KXalapjel
-
base
.
kiértékelő egység
teherfelvevő
indicator
load receptor
példa: közúti hídmérleg KX-EMX100/111-VSH; régi jele: VSH 200 CS 2 Description of the type The name of type has 3 fields: base name: ¾ name of indicator:
name of load receptor:
example: weighbridge
(KX), (01; 01/Mxxx; MIDI; DUAL ;MT; MTT; MTC; EMX100/1xx IQMx-y-z), (VSH; TS-GSX; LMG; RMGK).
KX-EMX100/111-VSH ; old type: VSH 200 CS
2.1 Mechanikai felépítés A mérleg alapvetően kiértékelő egységből, valamint emelőrendszer nélküli teherfelvevőből áll. 2.1 Mechanical construction The weighing instrument generally comprises the indicator and the load receptor without leverwork.
2.2 Elektronikus felépítés Kiértékelők analóg mérlegcellákhoz: Típusjel 01; 01/Mxxx; MIDI; DUAL; MT; MTT; MTC EMX100/1xx
TC száma TH-8301/6/2004 TH-8297/6/2004
Bejegyzett testület OMH OMH
A kiértékelő egységre nyúlásmérőbélyeges mérlegcellák csatlakoztathatók. A mérlegcella kimenő jelét erősítés és digitalizálás után mikroprocesszor dolgozza fel. A mérési eredmények a konfigurációtól függően 7 szegmenses LCD vagy LED kijelzőn jelennek meg. Kiértékelő digitális mérlegcellákhoz: Típusjel IQMx-y-z
TC száma TH-8343/7/2005
Bejegyzett testület OMH
ORSZÁGOS MÉRÉSÜGYI HIVATAL
Engedély száma: TH-8401/4/2005
National Office of Measures, Hungary
Approval number: page 3 of 6 pages
3/6 oldal 2.2 Electrical construction Indicators for analog load cells: Type 01; 01/Mxxx; MIDI; DUAL; MT; MTT; MTC EMX100/1xx
TC number TH-8301/6/2004 TH-8297/6/2004
Notified body OMH OMH
Electronic indicator intended for connection of strain gauge load cells. The output signal of the load cell is amplified, digitized and subsequently processed in a micro processor. The weighing results are displayed in 7 segment LCD or LED display depending on the configuration. Indicator for digital load cells: Type IQMx-y-z
TC number TH-8343/7/2005
Notified body OMH
2.3 Megengedett funkciók és berendezések Lásd a vonatkozó TC-t. 2.3 Approved functions and features See the relevant TC.
2.4 További funkciók Lásd a vonatkozó TC-t. Egyes funkciók a kiértékelő egység kivitelétől függően hiányozhatnak. 2.4 Other function See the relevant TC. Some functions can be missing depending of the indicator.
3 Technikai adatok 3 Technical data
3.1 Mérleg Pontossági osztály: Mérési határ (Max): Hitelesítési osztásértéke száma: -változó osztásértékekre: Tárázási tartomány: Hőmérsékleti tartomány:
III vagy IIII 1 kg…120 t n ≤ 6000 III n ≤ 1000 IIII ni ≤ 3000 i = 1, 2 ≤ Max vagy Max1 100%-a -10 °C / +40 °C
A mérési tartományokat beleértve az alsó mérési határt, a hitelesítési osztásértéket és a hitelesítési osztásértékek számát, az alkalmazott mérlegcellára és a kiértékelő egységre megadott határértékek alapján a 3.2 szerint kell megállapítani. 3.1 Weighing instrument Accuracy class: Maximum capacity (Max): Max. number of verification scale interval: -for multi intervals: Range of tare: Temperature range:
III or IIII 1 kg…120 t n ≤ 6000 III n ≤ 1000 IIII ni ≤ 3000 i = 1, 2 ≤ 100% of Max or Max1 -10 °C / +40 °C
ORSZÁGOS MÉRÉSÜGYI HIVATAL
Engedély száma: TH-8401/4/2005
National Office of Measures, Hungary
Approval number: 4/6 oldal page 4 of 6 pages Weighing ranges including minimum load, verification scale interval and number of verification scale intervals may be chosen according 3.2. however limits of the indictor and the load cells used shall be considered.
3.2 Analóg mérlegcellák A kiértékelő egység és a teherfelvevő egység összekapcsolásával komplett mérleg alakítható ki. A következő feltételek teljesülése esetén bármely megfelelő (kompatibilis) mérlegcella használható. ¾ A celláról OIML (R 60) tanúsítvány vagy a 90/384/EK irányelv alapján típusvizsgálatra bejegyzett testület által az EN 45501 szabvány szerint kiadott Vizsgálati tanúsítvány rendelkezésre áll. ¾ A tanúsítvány a WELMEC útmutató szerinti megfelelőségi nyilatkozat kiállításához szükséges adatokat és az esetleges telepítési követelményeket tartalmazza. NH jelzésű mérlegcella csak az EN 45501 szabvány szerinti páraállósági vizsgálat után alkalmazható. ¾ A mérlegcella és a kiértékelő egység kompatibilitását az EK hitelesítés vagy a minőségbiztosításon alapuló típusegyezőségi nyilatkozat idején a WELMEC 2 útmutató szerinti kompatibilitás igazolás űrlappal igazolták. ¾ Az erőbevetés megfelel a WELMEC 2.4 mérlegcella útmutatóban megadott példák egyikének. A mérlegcellák általános elfogadási elve nem vonatkozik a 3.4 pontban megadott un. kritikus teherfelevőre. 3.2 Analog load cells The indicator can be connected to a weigh platform to form a complete weighing system. Any compatible load cell(s) may be used providing the following conditions are met: There is a respective OIML Certificate of Conformity (R 60) or a test Certificate (EN 45501) issued for the load cell by a Notified body responsible for type examination under Directive 90/384/EEC. The certificate contains the load cell types and the necessary load cell data required for the manufacturer’s declaration of compatibility of modules (WELMEC 2) and particular installation requirements. A load cell marked NH allowed only if humidity testing to EN 45501 has been conducted on this load cell. The compatibility of the load cells and indicator is established by the manufacturer by means of the compatibility of modules calculation, contained in the above WELMEC 2 document, at the time of EC verification or declaration of EC conformity of type. The load cell transmission must conform to one of the examples shown in the WELMEC Guide 2.4. The general acceptance of load cells is not valid for critical load receptors mentioned in 3.4.
3.3 Digitális mérlegcellák Mérlegcella típusjele SBC SCC DSC
Mérlegcella gyártója Revere Revere Revere
TC száma PTB D09-99.19 PTB D09-99.18 PTB D09-03.08
3.3 Digital load cells Type of load cell SBC SCC DSC
Produced by Revere Revere Revere
TC number PTB D09-99.19 PTB D09-99.18 PTB D09-03.08
ORSZÁGOS MÉRÉSÜGYI HIVATAL National Office of Measures, Hungary
5/6 oldal 3.4 „Kritikus” teherfelvevő
Engedély száma: TH-8401/4/2005 Approval number: page 5 of 6 pages
A „TS-GSX” könnyen áttelepíthető közúti hídmérleg, áttelepítést követően újrahitelesítési kötelezettséggel. Beépített mérlegcellák: 4…8 db DSC vagy SCC típusú digitális mérlegcella. Megjegyzés: A VSH, LMG és RMGK típusú teherfelvevők nem kritikus teherfelvevők. 3.4 Critical load receptor The “TS-GSX” type is a weighbridge with the possibility of easy transportation and reinstallation. After the installation, the weighbridge is subject of reverification. The built-in load-cells are 4…8 pieces DSC orSCC type digital load cells. Note: Type of the load receptors VSH, LMG and RMGK are non-critical load receptors.
4 Interfészek és perifériák 4 Interfaces and peripheral devices
4.1 Interfészek Az interfészek az MSZ EN 45501 szabvány 5.3.6.1 előírásainak megfelelően visszahatás mentesek, ezért azokat bélyegezni nem kell. 4.1 Interfaces The interfaces are non-interacting according EN 45501 and need not to be secured.
4.2 Perifériák Hitelesítési kötelezettség alá tartozó esetekben az interfészekre a következő perifériák köthetők: ¾ EK típusvizsgálati eljárás keretében típusvizsgált KONTINEX gyártmányú periféria vagy típusvizsgált mérleghez köthető vizsgálati tanúsítvánnyal rendelkező bármilyen gyártmányú periféria. A vizsgálati tanúsítványt a 90/384/EK irányelv szerint bejegyzett testület adhatja ki. ¾ Tanúsítvánnyal nem rendelkező perifériák a következő feltételek teljesülés esetén használhatók: − A 89/336/EK számú EMC irányelvnek való megfelelőséget tanúsító CE jelzés feltüntetésre került. − A periféria a mérlegbe nem továbbít adatokat és utasításokat, a nyomtatást indító, adatátvitelt ellenőrző vagy érvényesítő adatokon és parancsokon kívül. − A periféria a mérési eredményt és mérlegből érkező adatokat mindenféle módosítás és feldolgozás nélkül nyomtatja. − A periféria teljesíti az MSZ EN 45501 szabvány követelményeit. 4.2 Peripheral devices For purposes subject to legal verification the following peripherals may be connected to the interfaces provided.
Peripheral devices that have been approved within the scope of an EC type approval issued to KONTINEX or which have been assessed to be connectable to EC type approved weighing instruments by a (EC) test certificate. The test certificate has to be issued by a notified body according the Directive 90/384/EEC. Peripherals without a test certificate under following conditions: − it bears the CE marking of conformity to the EMC Directive 89/336/EEC;
ORSZÁGOS MÉRÉSÜGYI HIVATAL
Engedély száma: TH-8401/4/2005
National Office of Measures, Hungary − − −
Approval number: 6/6 oldal page 6 of 6 pages it is not capable of transmitting any data or instruction into the weighing instrument, other than release a printout, checking for correct data transmission or validation; it prints weighing results and other data as received from the weighing instrument without any modification or further processing; it complies with the applicable requirements of EN 45501.
5 Típusvizsgálati feltételek ¾ Ez a típusvizsgálati tanúsítvány kifejezetten csak nem-automatikus működésű mérlegre vonatkozik. Automatikus működésű mód esetén (kiegészítő elemekkel vagy anélkül) a használat helyén érvényes EK és nemzeti előírásokat kell figyelembe venni. ¾ Fixen nem rögzített teherfelvevőket az MSZ EN 45501 szabványt kielégítő szintjelzővel és szintező eszközökkel kell ellátni. ¾ A mérlegcellák túlterhelését megfelelő konstrukciós eszközökkel (túlterhelésgátló , megfelelő névleges terhelésű cella) kell megakadályozni. ¾ A mérleg kezelőjének rálátással kell rendelkeznie a teherfelvevőre. Ez azonban nem kötelező a tartálymérlegek esetén. 5 Approval conditions The type approval is valid only for non-automatic weighing instruments. For automatic mode of use with or without additional devices the other EEC or national regulations of the site of use shall be considered. Load receptors that are not fixed firmly shall be equipped with a level indicator which meets the requirements of EN 45501 and levelling device. Overloading of the load cells has to be avoided by special constructive means (overload protection, sufficiently high nominal load cells or similar means). The operator’s position shall allow him to have a sight on the load receptor. This is not mandatory with hopper scales.
6 Lezárás, bélyegzés Öntapadó vagy függőhuzalos lezárást kell alkalmazni: ¾ a mérlegcella közösítő dobozon, ¾ a feliratokat tartalmazó adattábla eltávolításának megakadályozására, ha az roncsolásmentesen eltávolítható, ¾ a kiértékelő egységen a vonatkozó TC szerint, ¾ Ex kivitel esetén a Zener gátak bekötésein. 6 Securing, location of seals and verification marks Securing stamps or lead seals shall be applied to: the load cell junction box, the data plate bearing the descriptive marking against removal (unless self destroying at removal), on the indicator according the relevant TC, in case of Ex version the Zener barrier.
7 CE jel helye A CE megfelelőségi jelölést és annak kiegészítő jeleit, a zöld M-et a kiértékelő egységen kell elhelyezni a vonatkozó TC szerint. Megjegyzés: Az időszakos hitelesítés tanúsító jelet az adattábla mellett kell elhelyezni. 7 Location of the CE marking The mark of CE conformity, the green M have to be placed on the data plate according the relevant TC Note: The verification mark for re-verification has to be placed near to the data plate.