Humidity Roadmap
Aansluiting van NMi VSL op de Europese “roadmap” voor vochtontwikkeling Rien Bosma
NMi - the Art of Measurement
Inhoud
• • • •
iMERA Roadmap Humidity Huidige status bij het NMi VSL Ontwikkelingsprogramma 2009-2012
NMi - the Art of Measurement
iMERA • iMERA = Implementing Metrology in the European Research Area – Ontwikkelen van de metrologie in Europa, bijvoorbeeld in • Industrie – Metingen worden complexer – Meetbereiken worden groter en gewenste onzekerheden kleiner
• Nieuwe techonologische gebieden – o.a. nano- en bio-technologie
• Gebieden met groeiend belang van metrologie – o.a. chemie, voedselveiligheid
NMi - the Art of Measurement
iMERA • Hoe omgaan met de beperkte budgetten? – Meer samenwerking tussen NMI-s – ‘Sharing’ van faciliteiten – Strategische planning van langlopende ontwikkelingsprojecten
Roadmaps NMi - the Art of Measurement
Roadmap • “Roadmapping is a planning tool used to coordinate business needs with the resources and delivery mechanisms neccesary to achieve explotation” – Ontwikkeld in 70-jaren – Identificeerd marktbehoefte – Zet product vereiste, benodigde technologie en hulpbronnen in tijdsvolgorde
NMi - the Art of Measurement
Humidity Roadmap (start 2006) • Triggers: – Global warming – Geavanceerde fabricage technieken
• Doelen: – – – –
Verbeterde klimaatmodellen Reductie van CO2 Verbetering proces controle Vocht vrije fabricage o.a. bij waver productie
• Benodigdheden: – Verbetering vocht-standaarden – Uitbreiding van temperatuur- en drukbereiken en gassen anders dan lucht – Water-activiteit NMi - the Art of Measurement
Humidity Roadmap Triggers
Actions against global warming (energy efficiency, climate research) require better humidity measurements. Higher performance manufacturing will require better humidity process control and global interoperability Contaminant-free manufacturing Robust water vapour by minimising trace data for improved Energy efficiency by water and its climate models moisture control e.g. in adverse effects Precision industrial building materials and oven drying humidity control
Targets
Better humidity standards for high temperatures, Pressures, in non-air gases & steam
Better trace humidity standards
Experimental realisation
Standards for moisture: - ref. materials (stable) - standards for direct meas. instruments
Improved relative humidity standards
New water vapour formulations
Metrological application of basic science
New and improved transfer standards and methods
Modelling (e, f) based on new data Measurements of e and f
Enabling Science and technology
research-grade humidity instruments spectroscopic, condensation, etc.
2005
Emerging laboratory experimental techniques (Acoustic resonator, Doppler broadening…)
Improved vacuum pressure meas. at low temp.
Hygro-thermal modelling
Moisture field measurement
Universal moisture measurement/calibration techniques
Nano-scale humidity.& moisture measurement.
Advanced relative humidity sensor
Advances in nanotechnology
TIME
2020
NMi - the Art of Measurement
Huidige Status NMi VSL
• Primaire vocht generator • (kleine) Klimaatkamer • ‘Flow-mixing’-opstelling
NMi - the Art of Measurement
Primaire Vocht Generator Temperature-controlled bath
-60°C < Td/f < +70°C
LT Saturator
U(Td/f) = 0.04 – 0.07°C
Dry gas Mass Flow Controller
Pump
Presaturator
Hygrometer under test
HT Saturator
Temperature-controlled bath
¾ LTS (Lage temperatuur verzadiger): -60°C < T < 20°C ¾ HTS (Hoge temperatuur verzadiger): 5°C < T < 70°C ¾ Metingen bij atmosferische druk
NMi - the Art of Measurement
Primaire Vocht Generator
NMi - the Art of Measurement
(kleine) Klimaat kamer 10 % < rh% < 98 % (0°C < t90 < +70°C) U(rh%) = 0.3 – 0.8 %
NMi - the Art of Measurement
“Flow-mixing” opstelling Back pressure regulator
{xwet , φ wet }
MFC1 N2 Pressure Controller
Standard Humidity Generator
MFC2
xtot
MFC3
2 nm Filter N2
Purifier
Test instrument
Mass Flow Controller
{xdry ,φdry }
Minimum frostpoint: -85°C Uncertainty: ±1°C
NMi - the Art of Measurement
“Flow-mixing” opstelling
NMi - the Art of Measurement
Ontwikkelingsprogramma 2009-2012 • Uitbreiding temperatuurbereik primaire generator – Hoogste temperatuur van 70 °C naar 90/95 °C – Laagste temperatuur van –60 °C naar –100 °C ( 10 ppm(v) naar 14 ppb(v) )
• Uitbreiding relatieve vochtigheid bereik – Van 0 °C t/m 70 °C naar –40 °C t/m 180 °C
NMi - the Art of Measurement
Ontwikkelingsprogramma 2009-2012 • Nieuwe activiteiten – Dauwpunten bij hoge druk (maximum circa 40 Bar) – Dauwpunten bij gassen anders dan lucht o.a. • CO2 • Methaan • SF6
– Relatieve vochtigheid bij drukken anders dan atmosferisch – Water activiteit
NMi - the Art of Measurement