FIESSLER
infrarood beveiligings lichtscherm BWS Type 4
ELEKTRONIK
LSUW...
Handleiding
INHOUD:
AA AA AA
Veiligheidsaanwijzingen Gebruik
TÜV Rheinland
AAAAAA AAAAAA AAAAAA AAAAAA AAAAAA AAAAAA AAAAAA
Gebruikertips
Q ZERT
Electrische aansluiting Inbedrijfstelling
DIN EN ISO 9001 Reg. Nr. 96007
Fiessler Elektronik D-73734 Esslingen
Kastellstr. 9
Optional Telefon: 0711 / 91 96 97-0 Internet: http://www.fiessler.de Telefax: 0711 / 91 96 97-50 eMail:
[email protected]
FIESSLER ELEKTRONIK
Sinds 40 jaar zijn wij gespecialiseerd op het gebied van de opto-electronica. Onze ervaring is uw voordeel. Wij adviseren u graag bij uw probleemstelling.
2
inhouds opgave
FIESSLER ELEKTRONIK
Deel
Inhoud
blz
1 2 3 4 4.1 4.2 4.3 5 5.1 5.2 5.3 5.4 5.5 6 6.1 6.2 6.3 6.4 6.5 7 7.1 7.2 7.2.1 7.2.2 7.2.3 7.2.4 7.2.5 7.2.6 7.3 7.3 7.5 7.5.1 7.5.2 7.6. 7.6.1 7.6.2 7.6.3 8 8.1 8.2 9 9.1 9.2
Veiligheidsaanwijzingen Principes Eisen voor het gebruik van lichtschermen Beschrijving en toepassingsgebied Apparatenomschrijving Werking zender en ontvanger Werking LSUW Afmeting en gewichten Zender en ontvanger Opbouw ontvanger Ombuigspiegels Schakelversterker Opbouwbehuizing IP55 voor schakelversterker Montage Veilige afstand tot gevaarlijke zone Montage eisen Montage zender en ontvanger Bevestigingsmogelijkheden Werking met ombuigspiegels Electrische aansluiting Algemene tips Aansluitschema LSUW NSR 3-1 Algemene tips Funktie A: 1- of 2- tact bedrijf Funktie B: beveiligen met aanloopvergrendeling Funktie B1 Funktie C Funktie D Aansluitschema LSUW N1 Aansluitschema LSUW N1K Aansluitschema LSUW N1 DUO Beveiligen van een gevaren zone met 2 schermen Beveiligen van 2 gevaarlijke zone's Aansluitschema LSUW N1 muting Algemene tips. Mutingfunktie, 4 muting sensoren en tijdcontr defunktie Mutingfunktie, 4 muting sensoren zonder tijdcontr defunktie Inbedrijfstellen Instelaanwijzingen Foutzoeken Bijlagen Conformiteiten,toelatingen TUV proefverklaring
5 6 8 10 11 12 13 14 17 18 20 21 22 24 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45
Een veilige werking van de totale installatie is alleen met inachtneming van deze handleiding en de wettelijke voorschriften gewaarborgd. Deze handleiding is een deel van het lichtscherm en dient bij de montageplaats te worden bewaard.
3
FIESSLER ELEKTRONIK
4
Veiligheidsaanwijzingen
FIESSLER ELEKTRONIK
1
Leeg
Alle veiligheidsaanwijzingen zijn met dit symbool aangegeven en moeten bijzonder in acht worden genomen. Deze bedieningshandleiding geeft de gebruiker belangrijke informatie over het doelmatig toepassen van veiligheids lichtschermen LSUW NSR 3-1, LSUW N 1, LSUW N1 DUO en LSUW N1 Muting. Zij behoort tot de standaard leveringsomvang en moet bij de montageplaats worden bewaard. Alle gegevens in de handleiding en de wettelijke voorschriften dienen te worden gevolgd.
Handleiding lezen Voor inbedrijfstelling moet eerst deze handleiding worden doorgenomen. Vakkundig personeel Gevarentips
Montage: In bedrijfstellen en onderhoud mag alleen door vakkundig personeel worden uitgevoerd. Bij gebruik van een machine met veiligheidslichtscherm moet gecontroleerd worden dat voor inbedrijfstelling zich niemand in de gevaarlijke zone bevind. Op de machine moet een waarschuwingssignalering worden aangebracht. Lichtschermen beschermen niet tegen vliegende voorwerpen welke door het funktioneren van de machine worden veroorzaakt. Voor het verwijderen van de schakelversterker eerst de netspanning afschakelen. In de voet bevinden zich spanningvoerende delen. O p l e t t e n, d a g e l i j k s e co n t r o l e Voor elke ploeg aanvang is het lichtscherm op de volgende manier te testen(maximaal na 24 uur): Met de proefstaaf wordt aan de kant van de zender deze van begin tot einde afgedekt.De lamp "frei" mag tussen begin en einde niet branden. De proefstaaf diameter moet met de op het typeplaatje van de ontvanger voorzijde aangegeven diameter overeenkomen.
5
Principes
FIESSLER
2
ELEKTRONIK
Amateriele De veiligheidslichtschermen LSUW NSR 3-1 en LSUW N1 zijn contactloos werkende veiligheidsvoorzieningen. beveiligingsschermen Het doorbreken van het schermveld met een lichaamsdeel of voorwerp zal het uitgangssignaal veranderen. Hierdoor wordt de beveiliging effectief. Risicocategorie 4 De veiligheidslichtschermen behoren tot de risico categorie 4 overeenkomstig pr EN 954. Apparaten met risico categorie 4 zijn zelf controlerende amateriele veiligheidsvoorzieningen en bezitten de hoogste risico categorie. Zelfcontrole
Het systeem controleert zichzelf op goede werking.Een opgetreden defect leidt tot geven van een stop commando aan de besturing van de machine.
Schermveldhoogte Hoogte van het schermveld welke door de zender en ontvanger wordt gecreeerd. Ø = Hindernisgrootte
Schermveldbreedte Minimale/maximale toelaatbare afstand tussen zender en ontvanger. De toelaatbare afstand is op de LSUW ontvanger aangegeven. De afstand tussen de lenzen wordt als raster aangegeven. De LSUW is leverbaar in 15 en 30mm raster.
Schermveldhoogte
Raster
Hindernisgrootte Kleinste diameter van de hindernis waarbij nog een zekere onderbreking van de gevaarlijke beweging wordt uitgevoerd. De hindernisgrootte is afhankelijk van de rastermaat en de afstand tussen zender en ontvanger. In volgende tabel is dit weergegeven.
Schermveldbreedte
zender
Bereik in m Raster 15 mm Raster 30 mm
o ntvanger
0,2-0,5 0,5-1 1-2 1,5-3 2-4 4-6 6-8 8-10 10-12 12-15 20 mm 20 mm 20 mm 25 mm 30 mm 30 mm 40 mm 40 mm 40 mm – 40 mm 40 mm 40 mm 40 mm 40 mm 50 mm 60 mm 60 mm 70 mm 80 mm = Hindernisgrootte
Straalafstand
De afstand tussen de afzonderlijke lenzen wordt bij de LSUW N1de straal afstand genoemd. Standaard kan deze, afhankelijk van de schermveldhoogte tussen 90 en 495 mm bedragen. Als optie zijn afstanden in veelvouden van 15 mm mogelijk.
Veiligheidsafstand Dit is voor de bescherming tegen lichamelijk letsel benodigde minimale afstand S tussen lichtscherm en de gevaarlijke plaats. Het bepalen van deze afstand is aangegeven in de EN 999 norm, deel C machine specifikatie. Deze is afhankelijk van de hindernisgrootte, de nalooptijd, de aanspreektijd en de naderingssnelheid. Naloop Dit is de het deel van de gevaarlijke beweging wat nog wordt uitgevoerd als in het schermveld wordt gegrepen. Naloopafstand. Dit is de afstand welke tijdens de naloop wordt afgelegd. Nalooptijd De tijd tussen het uitschakelen en het stilstaan van de gevaarlijke beweging.
Naloop
S
Aanspreektijd Tijd tussen binnendringen in het schermveld en het schakelen van de relais in de schakelversterker. Ventiel of relais controle funktie
Voor elke vrijgave van de uitgangsrelais in de versterker wordt gecontroleerd of de aangesloten relais of ventielen afgevallen zijn. Als dit niet zo is is geen nieuwe vrijgave mogelijk. Uitval van een relais kan zo nooit tot het inschakelen van de gevaarlijke beweging leiden.
6
Principes
FIESSLER
2
ELEKTRONIK
Aanloopvergrendeling
Na inbedrijfstelling of spanningsonderbreking wordt door de aanloopvergrendeling de vrijgave geblokkeerd. Door eerst in het schermveld in te grijpen en vrij te geven en daarna de starttoets te bedienen worden de uitgangen van de versterker gesloten.
Herstartvergrendeling Deze vergrendelt de automatische vrijgave na onderbreking en vrijgave van het schermveld. Door bedienen van de starttoets worden het scherm vrijgegeven.
Tact bedrijf
De machine voert na een of tweemaal ingrijpen in het scherm automatisch een arbeidsslag uit en wacht daarna maximaal 30 seconde op opnieuw ingrijpen in het schermveld.Als deze tijd langer is als 30 seconden wordt de herstart vergrendeling aktief.
Beschermingsfunktie
Bij ingrijpen in het schermveld worden de uitgangen geopend. Na vrijgave van het scherm worden de uitgangen direct gesloten.
Muting Tijdelijke overbrugging van de veiligheidsfunktie voor b.v. materiaal transport. daarbij kan het lichtgordijn een ounderscheid maken tussen een mens en een palet of een vorkkeftruck.
7
FIESSLER
Eisen voor het gebruik van lichtschermen
3
ELEKTRONIK
-EN 50100-1 - De gevaarlijke toestand van een machine moet door het funktioneren van het lichtgordijn beeindigd worden. (Deel C, montage, inbedrijfstelling en testen van - De veiligheidsafstand moet zo groot zijn dat bij ingrijpen in het schermveld de gevaarlijke plaats niet kan worden bereikt voordat de gevaarlijke beweging gestopt is. een BWS aan de machine) - De toegang tot de gevaarlijke plaats mag alleen mogelijk zijn door het schermveld. Via de onder, boven of de zijkanten mag de gevaarlijke plaats niet te bereiken zijn. - Het zich bevinden achter het schermveld mag niet mogelijk zijn. Als dit wel mogelijk is moet bij het ingrijpen in het schermveld de herstart vergrendeling worden geactiveerd. Door de start toets te bedienen kan het scherm weer worden vrijgegeven. Deze startoets moet zich op een plaats bevinden vanwaar het een goed uitzicht biedt op de plaatsen waar men zich achter het schermveld kan bevinden. - Het onopzettelijk herhalen van een gevaarlijke beweging moet met de nodige zekerheid verhinderd worden.-De veiligheidsklasse (klasse 4) moet minstens met de veiligheidsklasse van de machine overeenkomen. - Oplevering van de montage en het testen moeten door een persoon worden uitge voerd welke daarvoor is opgeleid en alle informatie van de machine en lichtgordijn in zijn bezit heeft. - De gebruiker moet er voor zorgen dat het veiligheids lichtscherm jaarlijks wordt gecontroleerd door een deskundige. Dit kan een medewerker zijn van de fabrikant/leverancier of een opgeleide medewerker van de gebruiker. De firma Fiessler Elektronik kan op verzoek de oplevering en de jaarlijkse controle uitvoeren. Als extra service kunnen klanten worden geinstrueerd om de jaarlijkse controle in eigen beheer uit te voeren.
8
Eisen voor het gebruik van lichtschermen
FIESSLER ELEKTRONIK
prEN 999 Voor het vaststellen van de juiste afstanden kan het onderstaande diagram behulpzaam zijn. (Veiligheid van machines, De formules voor het berekenen van deze afstand (EN999) zijn op blz. 22 en 23 in deze handleiding benaderingssnelheid van weergegeven. lichaamsdelen voor het vaststellen van de uitvoering van de bescherming.) Voor de juiste veiligheidsafstand moet de gebruiker ook de specifieke machinenorm raadplegen. Keuze tabel voorgeschreven norm voor veiligheidsafstand tussen bescherminrichting en gevaarlijke plaats.
RISIKOBEPALING van het gevaar
Is een C norm beschikbaar
JA
NEE
JA
Is in deze C norm een voorgeschrevenen minimale aftstand aangegeven
NEE Berekenenvan de minimum afstand vlgs EN 999
Deze afstand gebruiken.
Kan deze afstand bereikt worden? Gezamelijke aanspreektijd of hindernis grootte verkleinen.
NEE
JA
JA Kan gezamelijeke ssnprektijd of hindernisgroote verkleind worden ?
Biedt deze afstand de moglijk om tussen het scherm en de gevarlijke plaats te komen ?
JA
NEE
NEE Beschermingsfunktie met herstartvergrendeling uitkiezen of extra maatregelen treffen om tussen het scherm en de gevaarlijke plaats aanweizig zijn te voorkomen
Andere of extra beveiligingen toepassen.
9
Minimale afstand benutten.
3
FIESSLER
Beschrijving en toepassingsgebied
4
E L E K T R O N I K
Infrarood veiligheids en stuurlichtschermen van de serie LSUW zijn contactloos werkende apparaten (BWS). Deze dienen om personen tegen ongevallen te beschermen. Hiertoe wordt het scherm zo geplaatst dat toegang tot de gevaarlijke plaats alleen via het schermveld mogelijk is. Bij ingrijpen in het schermveld wordt de machine tijdig en betrouwbaar uitgeschakeld. De LSUW veiligheids lichtschermen : -zijn TUV gekeurd en door de BG toegelaten -voldoen aan de EN 50100 klasse 4 -zijn zelfcontrolerend zonder extra schakeling -hebben kompakte bouwvorm, eenvoudige montage en afstelling -zijn jarenlang beproefd -alle funkties inclusief muting programmeerbaar Toepassingsgebieden lichtschermen LSUW : -persen voor hout,metaal,kunststof -filterpersen -buig- en kantbanken -spuitgietmachines -bewerkingscentra en lasrobots -montage automaten
Persbeveiliging
Beveiligen kabelautomaat
Zonebewaking 10
FIESSLER
Beschrijving en toepassingsgebied
4
type omschrijving
4.1
ELEKTRONIK
FIESSLER
Infrarotlicht-Empfänger Arbeitsreichweite: A-B m Hindernisgröße: cc mm
ELEKTRONIK
Plaats van de typeaanduiding
FIESSLER E L E K T R O N IK
IR-Empfänger LSUW
FIESSLER E L E K T R O N IK
IR-Sender LSUW
SH—Typ: .................................
SH—Typ: .................................
M / J / Nr.: .................................
M / J / Nr.: .................................
Spannung: 24 V =
Spannung: 230 V~
Schutzart : IP
Schutzart : IP
......................
Hindernisgröße und Reichweite siehe Frontplatte D-73734 Esslingen, Kastellstr. 9 0711 / 3 45 10 54
TÜV Rheinland
......................
D-73734 Esslingen, Kastellstr. 9 0711 / 345 10 54
Made in Germany Made in Germany
Apparaat code nummer zender en ontvanger
XX YY ZZZZ
Productie maand
Apparaat code nummer schakelversterker
Productie jaarIn
Serie nummer, 4 cijferig.
XX S ZZ YY
Productie maand
Apparaat code 0..4 = 5..6 = 7 = 8 = 9 =
11
LSUW NSR 3-1 LSUW N 1 LSUW N1 Muting LSUW N1 K LSUW N 1 Duo
Serie nummer
Productie jaar
FIESSLER
Beschrijving en toepassingsgebied
4
E L E K T R O N I K
Werking zender-ontvanger
4.2
Het veiligheids lichtschermsysteem LSUW bestaatuit 3 delen, zender ,ontvanger en schakelversterker. Alle componenten uit deze serie LSUW kunnen met elkaar worden gecombineerd. Voor verschillende veiligheidsmaatregelen zijn ontvangers met diverse rastermaten en schakelversterkers leverbaar.
Zender: Deze straalt over de gehele lengte een infrarood gemoduleerde lichtband uit. Ontvanger: Ontvanger:De ontvanger bestaat uit een aantal optiekbouwstenen in 15 of 30 mm of meer als 90 mm raster. Deze bouwstenen zien door de speciale optiek alleen het tegenoverliggende deel van de lichtband. De ontvangbouwstenen worden in serie geschakeld en worden door de zender gemoduleerd. Wanneer in het schermveld ingegrepen wordt zal de serie schakeling onderbroken worden De verwerkings elektronica in de ontvanger vormt 2 antivalente signalen welke aan schakelversterker worden aangeboden
Infra - rood zender Principe schema:
AAAA AAA AAAA AAA AAAA AAA AAAAAAA Verwerking
12
ONTVANGER
modulatie eenheid
4
Beschrijving en toepassingsgebied
FIESSLER ELEKTRONIK
4.3
Schakelversterkers LSUW.....
Er zijn 4 soorten schakelversterkers leverbaar. In onderstaande tabel is te zien welke funkties bij welke versterker horen.
Netz
power
tension
LS Frei
LC free
BS libre
AA AA AA
Netz
power
tension
frei
free
libre
TÜV Rheinland
AA AA AA
power
Netz
Netz power tension
tension
AA AA AA TÜV Rheinland
TÜV Rheinland
LS LC BS unterbrochen interrupted interrompu
LS B frei / unterbrochen
Wiederanlauf- restart sperre interlock
Wiederanlaufsperre restart interlock
sortie interrompue
output free
FIESSLER ELEKTRONIK
Nr./Baujahr
No./year of construction
No./année de fabrication
..................................
Ansprechzeit
response time
temps de réponse
30 mS
Temp.
temp.
temp.
-10… + 55 °C
Schutzart
enclosure rating
degré de protection
IP 40
Versorgung
supply voltage
tension d'alimentation
230 VAC -10% +15 %, 50Hz
Kontaktbel.
contact max.
charge contact maxi.
2 A, 250 VAC
frei / unterbrochen
Nr./Baujahr Ansprechzeit Temp. Schutzart Versorgung Kontaktbel.
power tension free / interrupt libre / interrompu
Typ: LSUW N1 K 230V Wiederanlaufsperre
restart interlock interdiction de redémarrage output free sortie libre
Ausgang frei
Vor Abziehen der Klemmleiste Netzspannung abschalten! Turn off the supply voltage ! Couper l'alimentation !
No./year of construction
No./année de fabrication
2
3
18
19
14
12
15
13
22
D
17
16
21
Unfallschutz-IR Lichtschranke Typ 4 IR-Safety Light Barriers Type 4 Barri•res de SŽcuritŽ-IR Type 4
FIESSLER
LSUW-N 1 Duo
ELEKTRONIK
Ansprechzeit
response time
temps de réponse
20 mS
temp.
temp.
-10… + 55 °C
Schutzart
enclosure rating
degré de protection
IP 40
Versorgung
supply voltage
tension d'alimentation
230 VAC -10% +15 %, 50Hz
Kontaktbel.
contact max.
charge contact maxi.
2 A, 250 VAC
No./year of construction
FIESSLER LSUW N 1 Muting
ELEKTRONIK
..................................
Nr./Baujahr
No./year of construction
No./année de fabrication
Ansprechzeit
response time
temps de réponse
20 mS
Ansprechzeit
response time
temps de réponse
Temp.
temp.
temp.
-10… + 55 °C
Temp.
temp.
temp.
Schutzart
enclosure rating
degré de protection
IP 40
Schutzart
enclosure rating
degré de protection
IP 40
Nr./Baujahr
No./année de fabrication
supply voltage
tension d'alimentation
230 VAC -10% +15 %, 50Hz
Versorgung
supply voltage
tension d'alimentation
230 VAC -10% +15 %, 50Hz
contact max.
charge contact maxi.
2 A, 250 VAC
Kontaktbel.
contact max.
charge contact maxi.
2 A, 250 VAC
Achtung
Achtung
Vor Abziehen des Gerätes Netzspannung abschalten und die vier Eckschrauben lösen !
Attention
Vor Abziehen des Gerätes Netzspannung abschalten und die vier Eckschrauben lösen !
Attention
Attention
Turn off the supply voltage and untie the four corner screws before taking off the device !
Turn off the supply voltage and untie the four corner screws before taking off the device !
Attention
Attention
Attention Couper l'alimentation et desserrer les quatre vis d'angle avant de déposer l'appareil !
Couper l'alimentation et desserrer les quatre vis d'angle avant de déposer l'appareil !
Couper l'alimentation et desserrer les quatre vis d'angle avant de déposer l'appareil !
.................................. 25 mS -10… + 55 °C
Versorgung Kontaktbel.
Vor Abziehen des Gerätes Netzspannung abschalten und die vier Eckschrauben lösen !
Couper l'alimentation et desserrer les quatre vis d'angle avant de déposer l'appareil !
0711 / 3 45 10 54 , Made in Germany
Made in Germany
LSUW NSR 3-1
BS desactivée
..................................
Temp.
Fiessler Elektronik D-73734 Esslingen, Kastellstr. 9
LC muted
TÜV Rheinland
20
Turn off the supply voltage and untie the four corner screws before taking off the device !
Fiessler Elektronik D-73734 Esslingen, Kastellstr. 9 0711 / 3 45 10 54
sortie libre
Muting LS gebrückt
Made in Germany
1
Turn off the supply voltage and untie the four corner screws before taking off the device !
Attention
output free
Ausgang frei
TÜV Rheinland
Ausgang frei output free sortie libre
Achtung
Achtung
AA AA AA
interdiction de redémarrage
AA AA AA
Vor Abziehen des Gerätes Netzspannung abschalten und die vier Eckschrauben lösen !
Attention
restart interlock
Wiederanlaufsperre
Wiederanlaufsperre restart interlock interdiction de redémarragee
No./year of construction No./annŽe de fabrication ................................. response time temps de rŽponse 20 mS temp. temp. -10É + 55 ¡C enclosure rating degrŽ de protection IP 20 supply voltage tension d'alimentation 230 VAC -15% +10 %, 50Hz contact max. charge contact maxi. 2 A, 250 VAC
Achtung Attention Attention
LSUW N 1
LSUW NSR 3 - 1 Nr./Baujahr
Netz
ELEKTRONIK Kastellstr.9 73734 Esslingen Tel. 0711/ 345 19 44 Schaltgerät BWS Typ 4 Switching unit ESPE Type 4 Boîtier de commande ESPS Type 4
Unfallschutz-IR Lichtschranke Typ 4 IR-Safety Light Barriers Type 4 Barri•res de SŽcuritŽ-IR Type 4
FIESSLER
ELEKTRONIK
interdiction de redémarrage sortie libre
LS unterbrochen LC interrupted BS interrompu
frei / unterbrochen free / interrupt libre / interrompu
FIESSLER output free
Ausgang frei
sortie libre
Unfallschutz-IR Lichtschranke Typ 4 IR-Safety Light Barriers Type 4 Barrières de Sécurité-IR Type 4
libre / interrompu
interdiction de redemarrage
Ausgang output unterbrochen interupted Ausgang frei
free / interrupt
LS A
Fiessler Elektronik
LSUW N1
LSUW N1 K
Programmeerbaar
D-73734 Esslingen,
Kastellstr. 9
0711 / 3 45 10 54
Fiessler Elektronik
D-73734 Esslingen,
Kastellstr. 9
LSUW N1 Duo voor het aans- LSUW N1 Muting luiten van 2 schermen overbruggen beveiliging
schakelversterker LSUW NSR 3-1 LSUW N1 programmeerbaar LSUW N1 K Funktion
LSUW N1 Duo
LSUW N1 Muting
Lichtgordijn bewaking
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Aanloopvergrendeling
Herstartvergrendeling
Relais of ventiel controle Beschermen en sturen bij cyclisch ingrijpen1 tact bedrijf
X Beschermen en sturen bij cyclisch ingrijpen 2 tact bedrijf
X Beschermen met wederaanloop tijdens gehele cyclus.
X Beschermen zonder Herstartvergrendeling met relais of ventiel controle
X
Bescherming met Herstartvergrendeling en cyclisch testen.
X Twee gecontroleerde sluiters voor machine sturing
X Aansluiting voor 2 lichtschermen
X
Aansluiting funktie keuze schakelaar
X
Programmeerbare funkties
X Muting = tijdelijkoverbruggen
X Deze funkties zijn de betreffende schakelversterker uit te voeren.: X 13
0711 / 3 45 10 54 , Made in Germany
Uitvoering, afmetingen en gewichten
FIESSLER E L E K T R O N I K
Behuizing: Montage: Bescherming: Elektrische aansluiting:
Afmeting:
5 5.1
Zender en ontvanger
Aluminium profiel bekleed met kunsstof RAL 1020 geel. Eindstukken uit zuurbestending polyamide. Licht inen uit trede voorzien van plexiglas. Als optie is oplossingbestendig silikaat glas leverbaar. Verschuifbare lippen op 3 behuizings zijden. IP 55. Optie IP 65. Steker DIN 43650
instelborgmoer M6
ontvanger
zender
AA AA
46
130
L
110
boring Ø 7 t.b.v. montage
55
92,5
boring Ø 7 t.b.v. montage en aarding
5
instelborgmoer M6
27
10
7
AA AA A AA AA AA AA A AA
130
5,2 Ø
27
11 Ø
45o
5,2 Ø
110
27
10,5
AA AA AA AA AA AA AA AA AA AA AA AA AA
10,5
5,2 Ø
27
5,2 Ø
Bevestigingslippen
7
10
5
50
5
Afmeting veiligheids lichtschermen LSUW.... schermhoogte
50
ontvanger Lengte
gewicht
bestelcode
bestelcode
gram 15 mm
gram 30 mm
IR -ontvanger LSUW ...
IR-ontvanger LSUW ...
...
zender Lengte
bestelcode gewicht IR-zender LSUW ...
...
120 mm
226 mm
1110 g
...120/9
...120/5
256 mm
1110 g
...120
235 mm
314 mm
1550 g
...235/15
...235/8
344 mm
1410 g
...235
355 mm
464 mm
2300 g
...355/25
...355/12
494 mm
2200 g
...355
505 mm
616 mm
2800 g
...505/35
...505/17
646 mm
2700 g
...505
685 mm
766 mm
3500 g
...685/45
...685/23
796 mm
3100 g
...685
895 mm
996 mm
4500 g
...895/60
...895/30
1026 mm
3800 g
...895
1135 mm
1226 mm
5300 g
...1135/75
...1135/38
1256 mm
4900 g
...1135
1435 mm
1526 mm
6500 g
...1435/95
...1435/48
1556 mm
5700 g
...1435
1600 mm
1697 mm
7850 g
...1600/107
...1600/54
1736 mm
6990 g
...1600
1800 mm
1940 mm
8970 g
---
...1800/61
1970 mm
7930 g
...1800
2000 mm
2012 mm
9310 g
---
...2000/68
2042 mm
8220 g
...2000
14
Uitvoering, afmetingen en gewichten
FIESSLER E L E K T R O N I K
Afmeting 2-3 en meerstralige lichtschermen voor zone bewaking:
Zender en ontvanger
scherm
aantal stralen
straal afstand
ontvanger
lengte gewicht
bestelcode
IR -ontvanger LSUW ...
zender
5 5.1
bestelcode
lengte gewicht IR-zender LSUW ...
... 505 mm
2
480 mm
616 mm 2800 g
...505/2
646 mm 2700 g
505/2
505 mm
3
255 mm
616 mm 2800 g
...505/3
646 mm 2700 g
505/3
505 mm
4
165 mm
616 mm 2800 g
...505/4
646 mm 2700 g
505/4
505 mm
5
120 mm
616 mm 2800 g
...505/5
646 mm 2700 g
505
505 mm
6
90 mm
616 mm 2800 g
...505/6
646 mm 2700 g
505
685 mm
3
330 mm
766 mm 3500 g
… 685/3
796 mm 3100 g
685/3
685 mm
4
210 mm
766 mm 3500 g
… 685/4
796 mm 3100 g
685
685 mm
5
165 mm
766 mm 3500 g
… 685/5
796 mm 3100 g
685
685 mm
6
120 mm
766 mm 3500 g
… 685/6
796 mm 3100 g
685
685 mm
7
105 mm
766 mm 3500 g
… 685/7
796 mm 3100 g
685
685 mm
8
90 mm
766 mm 3500 g
… 685/8
796 mm 3100 g
685
895 mm
3
405 mm
996 mm 4500 g
… 895/3
1026 mm 3800 g
895/3
895 mm
4
285 mm
996 mm 4500 g
… 895/4
1026 mm 3800 g
895/4
895 mm
5
210 mm
996 mm 4500 g
… 895/5
1026 mm 3800 g
895
895 mm
6
165 mm
996 mm 4500 g
… 895/6
1026 mm 3800 g
895
895 mm
7
135 mm
996 mm 4500 g
… 895/7
1026 mm 3800 g
895
895 mm
8
120 mm
996 mm 4500 g
… 895/8
1026 mm 3800 g
895
895 mm
9
105 mm
996 mm 4500 g
… 895/9
1026 mm 3800 g
895
895 mm
10
90 mm
996 mm 4500 g
… 895/10
1026 mm 3800 g
895
1135 mm
4
360 mm
1226 mm 5300 g
… 1135/4
1256 mm 4900 g
1135/4
1135 mm
5
270 mm
1226 mm 5300 g
… 1135/5
1256 mm 4900 g
1135/5
1135 mm
6
210 mm
1226 mm 5300 g
… 1135/6
1256 mm 4900 g
1135
1135 mm
7
180 mm
1226 mm 5300 g
… 1135/7
1256 mm 4900 g
1135
1135 mm
8
150 mm
1226 mm 5300 g
… 1135/8
1256 mm 4900 g
1135
1135 mm
9
135 mm
1226 mm 5300 g
… 1135/9
1256 mm 4900 g
1135
1135 mm
10
120 mm
1226 mm 5300 g
… 1135/10
1256 mm 4900 g
1135
1135 mm
11
105 mm
1226 mm 5300 g
… 1135/11
1256 mm 4900 g
1135
1135 mm
12
90 mm
1226 mm 5300 g
… 1135/12
1256 mm 4900 g
1135
1435 mm
4
465 mm
1526 mm 6500 g
… 1435/4
1556 mm 5700 g
1435/4
1435 mm
5
345 mm
1526 mm 6500 g
… 1435/5
1556 mm 5700 g
1435/5
1435 mm
6
270 mm
1526 mm 6500 g
… 1435/6
1556 mm 5700 g
1435/6
1435 mm
7
225 mm
1526 mm 6500 g
… 1435/7
1556 mm 5700 g
1435/7
1435 mm
8
195 mm
1526 mm 6500 g
… 1435/8
1556 mm 5700 g
1435
1435 mm
9
165 mm
1526 mm 6500 g
… 1435/9
1556 mm 5700 g
1435
1435 mm
10
150 mm
1526 mm 6500 g
… 1435/10
1556 mm 5700 g
1435
1435 mm
11
135 mm
1526 mm 6500 g
… 1435/11
1556 mm 5700 g
1435
1435 mm
12
120 mm
1526 mm 6500 g
… 1435/12
1556 mm 5700 g
1435
1435 mm
14
105 mm
1526 mm 6500 g
… 1435/14
1556 mm 5700 g
1435
1435 mm
16
90 mm
1526 mm 6500 g
… 1435/16
1556 mm 5700 g
1435
15
Uitvoering, afmetingen en gewichten
FIESSLER E L E K T R O N I K
Afmeting 2-3 en meerstralige lichtschermen voor zone bewaking:
5 5.1
Zender en ontvanger
scherm
aantal straalen
stralafstand
ontvanger
bestelcode
lengte gewicht
IR -ontvanger LSUW ...
zender
bestelcode
lengte gewicht IR-zender LSUW ...
... 1600 mm
5
390 mm
1697 mm
7850 g … 1600/5
1727 mm
6990 g
1600/5
1600 mm
6
315 mm
1697 mm
7850 g … 1600/6
1727 mm
6990 g
1600/6
1600 mm
7
255 mm
1697 mm
7850 g … 1600/7
1727 mm
6990 g
1600/7
1600 mm
8
225 mm
1697 mm
7850 g … 1600/8
1727 mm
6990 g
1600
1600 mm
9
195 mm
1697 mm
7850 g … 1600/9
1727 mm
6990 g
1600
1600 mm
10
165 mm
1697 mm
7850 g … 1600/10
1727 mm
6990 g
1600
1600 mm
11
150 mm
1697 mm
7850 g … 1600/11
1727 mm
6990 g
1600
1600 mm
12
135 mm
1697 mm
7850 g … 1600/12
1727 mm
6990 g
1600
1600 mm
14
120 mm
1697 mm
7850 g … 1600/14
1727 mm
6990 g
1600
1600 mm
16
105 mm
1697 mm
7850 g … 1600/16
1727 mm
6990 g
1600
1600 mm
18
90 mm
1697 mm
7850 g … 1600/18
1727 mm
6990 g
1600
1800 mm
5
450 mm
1940 mm
8970 g … 1800/5
1970 mm
7930 g
1800/5
1800 mm
6
360 mm
1940 mm
8970 g … 1800/6
1970 mm
7930 g
1800/6
1800 mm
7
300 mm
1940 mm
8970 g … 1800/7
1970 mm
7930 g
1800/7
1800 mm
8
255 mm
1940 mm
8970 g … 1800/8
1970 mm
7930 g
1800/8
1800 mm
9
225 mm
1940 mm
8970 g … 1800/9
1970 mm
7930 g
1800/9
1800 mm
10
195 mm
1940 mm
8970 g … 1800/10
1970 mm
7930 g
1800
1800 mm
11
180 mm
1940 mm
8970 g … 1800/11
1970 mm
7930 g
1800
1800 mm
13
150 mm
1940 mm
8970 g … 1800/13
1970 mm
7930 g
1800
1800 mm
14
135 mm
1940 mm
8970 g … 1800/14
1970 mm
7930 g
1800
1800 mm
16
120 mm
1940 mm
8970 g … 1800/16
1970 mm
7930 g
1800
1800 mm
18
105 mm
1940 mm
8970 g … 1800/18
1970 mm
7930 g
1800
1800 mm
21
90 mm
1940 mm
8970 g … 1800/21
1970 mm
7930 g
1800
2000 mm
5
495 mm
2012 mm
9310 g … 2000/5
2042 mm
8220 g
1800/5
2000 mm
6
390 mm
2012 mm
9310 g … 2000/6
2042 mm
8220 g
1800/6
2000 mm
7
330 mm
2012 mm
9310 g … 2000/7
2042 mm
8220 g
1800/7
2000 mm
8
285 mm
2012 mm
9310 g … 2000/8
2042 mm
8220 g
1800/8
2000 mm
9
240 mm
2012 mm
9310 g … 2000/9
2042 mm
8220 g
1800/9
2000 mm
10
210 mm
2012 mm
9310 g … 2000/10
2042 mm
8220 g
1800/10
2000 mm
11
195 mm
2012 mm
9310 g … 2000/11
2042 mm
8220 g
1800
2000 mm
12
180 mm
2012 mm
9310 g … 2000/12
2042 mm
8220 g
1800
2000 mm
13
165 mm
2012 mm
9310 g … 2000/13
2042 mm
8220 g
1800
2000 mm
14
150 mm
2012 mm
9310 g … 2000/14
2042 mm
8220 g
1800
2000 mm
15
135 mm
2012 mm
9310 g … 2000/15
2042 mm
8220 g
1800
2000 mm
120 mm
2012 mm
9310 g … 2000/17
2042 mm
8220 g
1800
2000 mm
17 20
105 mm
2012 mm
9310 g … 2000/20
2042 mm
8220 g
1800
2000 mm
23
90 mm
2012 mm
9310 g … 2000/23
2042 mm
8220 g
1800
Bestelkode voor kompleet Schakelversterker LSUW NSR 3-1 systeem, bestaande uit zender, pr.baar ontvanger en schakelversterker: bestelcode ( zie ontvanger ) LSUW NSR 3-1...
LSUW N1 LSUW N1 K
LSUW N1 Duo
LSUW N1 Muting
LSUW N1 ... LSUW N1 K ...
LSUW N1 Duo...
LSUW N1 Muting...
Voorbeeld 1: LSUW N1 895/3 bestaat uit ontvanger LSUW 895/3 ,zender LSUW S 895 en de schakelunit LSUW N1. Aantal stralen 3. Schermveld hoogte 895 mm. Voorbeeld 2: LSUW NSR 3-1 1435/95 bestaat uit ontvanger LSUW 1435/95, zender LSUW S 895 en schakelunit LSUW NSR 3-1. Raster maat is 15 mm. Aantal stralen is 95. S.V.P. altijd reikwijdte zender - ontvanger aangeven bij bestellingen, zie ook tabel in deel 6.1 16
Mechanische gegevens en maatvoering
FIESSLER ELEKTRONIK
Lenzen volgorde ontvanger
Lenzen volgorde (ontvanger):
5 5.2
A A AAA 1
1
A AA 1
AAA A A AAAA AA A AA AA AA AAA AA
Steker
46 mm
Deksel
1
A
eerste lens
Verwerking
SH
Blindmoduul
A
laatste lens
Ontvangmoduul
B
Deksel
1
AA
1
A A AA
1
AAA A AA AA
1
1
1
5/9
8/15
12/25
17/35
23/45
30/60
AAAAA AAAAA AAAAA AAAAA AAAAA AAAAA AAAAA AAAAA AAAAA AAAAA AAAAA AAAAA AAAAA AAAAA AAAAA AAAAA AAAAA AAAAA
Minimum bevestigingsafstand:
Ontvanger:
Typ A: mm SH: mm B: mm BFA: mm
120/... 45 136 45 266
235/... 50 221 45 356
355/... 65 351 50 506
505/... 60 496 60 656
685/... 50 673 45 808
Zender :
Typ BFA: mm
120 296
235 386
355 536
505 686
685 838
Lengten van zenders en ontvangers zie pagina 14 - 16. 17
38/75
48/95
54/107
2000/...
1800/...
1600/...
1435/...
1135/...
895/...
685/...
505/...
235/...
355/...
1
120/...
AA
61
68
Minimum bevestigingsafstand BFA
895/... 1135/... 1435/... 1600/... 1800/... 2000/... 50 50 50 35 35 35 882 1122 1422 1627 1839 2049 60 45 45 35 35 35 1032 1257 1557 1737 1949 2159
895 1062
1135 1287
1435 1587
1600 1767
1800 1979
2000 2189
FIESSLER
Mechanische gegevens en maatvoering
ELEKTRONIK
Ombuigspiegels voor meerstraals lichtschermen.
Afmeting : Montage :
5 5.3
Uitvoering:torsiearm aluminium profiel,kunststof bekleed RAL1021 geel. met kogelkop schroef.
LP
LB ± 2 mm
Montage tekening:
Drukstift
M10
AAAAAA
Inbus 5 mm
90 44
60
7
M10
116
Scharnierbereik ± 30 Graden.
18
FIESSLER
Mechanische gegevens en maatvoering
5
ELEKTRONIK
Ombuigspiegels voor meerstraals lichtschermen
5.3
Bouwgrootten:
Schermhoogte Lengte LP Gat afstand LB Gewicht g
120 235 355 505 685 895 1135 1435 1600 1800 2000 205 315 465 618 765 995 1.210 1.510 1.710 1.910 2.110 mittig* 210 360 513 660 890 1.105 1.405 1.605 1.805 2.005 1.699 2.392 3.337 4.300 5.227 6.676 8.030 9.920 11.180 12.440 13.700 * Bevestiging met 1 kogelkopschroef.
Montage instructie:
1. kogelkop in uitsparing plaatsen 2. drukstift plaatsen 3. inbusschroef aandraaien met inbus sleutel 5 mm. De spiegel kan met de kogelkopfschroef aan een frame worden gemonteerd. Verder bieden ook de gaten in het profiel moglijkheden tot montage van de spiegels.
19
Mechanische gegevens en maatvoering
FIESSLER E L E K T R O N I K
NSR 3-1, N1, N1 Duo, N1 Muting Behuizing: Montage: Bescherming: Aansluiting: Gewicht:
Schakelversterker LSUW ...
ABS kunsstof behuizing RAL 1020 4 gaten in bodem, zie tekening. Optie is klik bevestiging op DIN rail 35 mm. IP40,inbouwuitvoering,IP55 door opbouw behuizing. steekbaar. 2550 gram. Behuizing met steek aansluiting en voet ( zij aanzicht ) 1. afdekkap 2. voet 3. steekvoet
Steekvoet
Behuizing(vooraanzicht) Behuizing
(zijaanzicht)
Behuizing(bovenaanzicht)
N1 K Behuizing: Montage: Bescherming: Aansluiting: Gewicht:
Kunsstof behuizing zwart, deksel beige. DIN rail 35 mm. of schroefbaar M 4. IP 40 klemmschroeven 800 gram
20
5 5.4
FIESSLER
Mechanische gegevens en maatvoering
5
E L E K T R O N I K
Opbouw behuizing IP 55 voor schakelunit
5.5
Behuizing: Montage: Bescherming: Aansluiting: Gewicht:
bodem kunststof grijs, deksel makrolon doorzichtig. 4 gaten in bodem. IP 55 via PG kabeldoorvoering. 800 gram
190
5
280
250
5
Kabelwartel 170
207
21
Montage
6
Veiligheidsafstand tot de gevaarlijke plaats
6.1
FIESSLER ELEKTRONIK
Algemeneirchtlijne: De veiligheidsafstand S tussen lichtscherm en gevaarlijke plaats moet zo groot zijn dat bij indringen in het schermveld gevaarlijke plaats niet kan worden bereikt voordat de gevaarbrengende beweging gestopt is. Volg hier de EN 999 en verdere nationale en internationale veiligheidsrichtlijnen. Veiligheidsafstand: De veiligheidsafstand s (in mm) is afhankelijk van: - Grijpsnelheid (mm/sec) - Aanspreektijd van het lichtscherm (sec) Deze betraagt voor LSUW N1, N1 K, N1 Duo 20 ms. Voor LSUW N1 muting 25 ms. en voor LSUW NSR 3-1 30 ms. - Nalooptijd van de maschine (sec) (moet door machine bouwer worden opgegeven) - Minimale hindernis grootte (mm)
de
S K t1
t2 d
De gezamelijke nalooptijd T wordt samengesteld uit deaanspreektijd van het lichtscherm t1 en nalooptijd van de machine t2. T= t1+ t2 De minimale herkenbare hindernisgrootte d is afhankelijk van de afstand tussen zender en ontvanger(reikwijdte). reikwijdte in m Raster 15 mm Raster 30 mm
0,2-0,5 0,5-1 1-2 1,5-3 2-4 4-6 6-8 8-10 10-12 12-15 20 mm 20 mm 20 mm 25 mm 30 mm 30 mm 40 mm 40 mm 40 mm – 40 mm 40 mm 40 mm 40 mm 40 mm 50 mm 60 mm 60 mm 70 mm 80 mm = Hindernisgrotte
De formule voor het berekenen van de veligheidsafstand is als volgt:
S = (1600 mm / s . T) + 8( d-14)
S > 500 mm
S = (2000 mm / s . T) + 8( d-14) 100 mm ≤ S ≤ 500 mm
Voorbeeld 1. Nalooptijd machine 75 ms. De veiligheidsafstand voor een LSUW ... met raster 15 mm en een hindernis grootte van 20 mm bedraagt : S = (2000 mm /s . 0,095s) + 8 ( 20-14) S = 238mm De veiligheidsafstand voor een LSUW ... met raster 30 mm en een hindernis grootte van 40 mm bedraagt : S = (2000 mm /s . 0,095s) + 8 ( 40-14) S = 398 mm Voorbeeld 2. Nalooptijd maschine 275 ms. De veiligheidsafstand voor een LSUW.... met raster 15mm en een hindernis grootte van 20 mm bedraagt: S = (1600 mm /s . 0,295s) + 8 ( 20-14) S = 520mm De veiligheidsafstand voor een LSUW.... met raster 30 mm en een hindernis grootte van 40 mm bedraagt: S = (1600 mm /s . 0,295s) + 8 ( 40-14) S = 680mm
22
Montage
FIESSLER E L E K T R O N I K
Formule voor het berekenen van de veiligheidsafstand bij zone beveiliging:
Veiligheidsafstand tot de gevaarlijke plaats
S = (1600 mm / s . T) + 850 mm Voorbeeld: Nalooptyd van de machine 75 ms De veiligheidsafstand voor een LSUW ... met 3 stralen en schakelversterker LSUW N 1 bedraagt:
S = (1600 mm /s . 0,095s) + 850 mm S = 1002mm
AAAAAA AAAAAA AAAAAA AAAAAA AAAAAA AAAAAA
AAAAA AAAAA AAAAA AAAAA AAAAA AAAAA
1,2
ontvanger
0,9 0,6
0,3
AAAAAA AAAAAA AAAAAA AAAAAA AAAAAA AAAAAA AAAAAA AAAAAA AAAAAA AAAAAA AAAAAA AAAAAA
0,4
zender
1,1 0,9
Aantal stralen: 2
23
AAAAA AAAAA AAAAA AAAAA AAAAA AAAAA
ontvanger
0,7
0,3
zender
Aantal stralen: 3
AAAAA AAAAA AAAAA AAAAA AAAAA AAAAA
ontvanger
zender
Aantal stralen: 4
Hoogte vanaf werkvloer
Plaatsing van de lichtstralen:
6 6.1
FIESSLER
Montage
6
E L E K T R O N I K
Montage regels
6.2
Montage zonder afscherming:
Vermijden om over en onder het lichtgordijn te grijpen:
Tussen lichtzender (a) en de lichtontvanger (b) bevindt zich het lichtscherm. Bij onderbreking in het schermveld b.v. door een hand wordt door het stuurstroomcircuit te openen de gevaarlijke beweging verhinderd of onderbroken. Het bereiken van de gevaarlijke plaats om het scherm heen vanaf de werkplek is in dit voorbeeld niet mogelijk. Een extra afscherming aan de voorzijde is hier overbodig. Om te voorkomen dat men tussen het scherm en de machine kan komen mag de afstand tussen beide maximaal 75 mm bedragen.
≤ 75 mm
Bescherming tegen onder/boven langs benaderen gevaarlijke plaats Bij normale gang van zaken (tek 1)legt de bediener zittend het werkstuk in de machine. Op grond van de naloopsnelheid wordt het lichtscherm LSUW..(a) iets voor de gevaarlijke plaats gemonteerd. Bij de hier gekozen beschermhoogte ontstaat boven het scherm een onbeschermd stuk. Tek. 2 toont hoe het zo tot ongelukken kan leiden. goed
verkeerd
1 Vermijden om over en onder het lichtgordijn te klimmen en dit bij modes A,B1,C,D en schakelversterker LSUW NSR 3-1:
2
3
Bij tek 3 is aangegeven hoe dat door het aanbrengen van een LSUW met hoger scherm hoogte dit kan worden voorkomen. Bescherming tegen achterhetschermveld bevinden Moet de afstand van het scherm om technische redenen zo groot worden gekozen dat zich een persoon tussen scherm en gevaarlijke plaats kan bevinden moet de situatie door een extra scherm of en beschermstang worden beveiligd.(tek 3)
24
verkeerd
goed
FIESSLER
Montage
6
E L E K T R O N I K
Montageregels
6.2
Afstand tot spiegelende oppervlakken:
Om te GEVARENBEREIK Gefahrenbereich vermijden dat een object reflekterend door hetObjekt reflektierendes niet word lichtgordijn (vingers e.d.) (z.B. Container) herkend door 4o a 4o omspiegeling noet het LSUW LSUW scherm met LSUW Sender Zender Naderingsrich Empfänger Annäherungsrichtung een minima- Ontvanger unterbrochener Strahl zentraler Strah le afstand Centralestraal Onderbrokenstraal avan het reflecterende object worden geplaatst. Deze minimale maat a kan uit volgende tabel worden gehaald. Montageafstand in m afstand a in mm
2,5 - 3 105
4 140
Het lichtscherm LSUW kan op basis van het speciale lensen system direct op een spiegelnde oppervlakte worden gemonteerd. Objecten worden zo ook op spiegelende oppervlakten herkend. Voor de directe opbouw op werkplekken is een uitvoering leverbaar met vlak aluminium deksel. Hier begint het schermveld dicht boven de reflecterende oppervlakte.
5 180
6 210
7 250
Zender Sender
zentraler Strahl spiegelnde Oberfläche
reflekterend
Om wederzijdse be Invloeding van twee lichtgordijnen LSUW te voorkomen moet bij de toepassing het volgende in acht genomen
Ont vanger
Ont vanger
Zender
Zender
Ont vanger
25
Zender
10 350 Empfänger Ontvanger
Centralestraal
Montage van 2 lichtschermen LSUW:
8 280
Zender
Ont vanger
Ont vanger
AAAAAAAAA AAAAAAAAA
Ont vanger
Zender
Zender
≤ 0,3 o
Montage
6
Montage zender en ontvanger
6.3
FIESSLER ELEKTRONIK
Montage zender en ontvanger:
Bevestigingsbeugels:
Montage zender en ontvanger De zender is ca. 30 mm langer door de ingebouwde montagehulplamp.Hiermee dient rekening gehouden te worden bij de montage.Niet de stekkerzijde maar de bovenkant moet dus bij het monteren in horizontale lijn liggen
De bijgevoegde bevestigingshulpstukken dienen om de LSUW lichtgordijnen te bevestigen en af te regelen.In kombinatie met de aluminium profielen laten ze bevestiging toe op vele manieren. schraf voor aarding van de bevestigingsbengels. Bevestigingsboring 7mm voor bevestiging en aarding
a
b Justageschroeven met kontermoeren
Bevestiging volgens afbeelding a aanbevden
Antitrilbevestiging:
Bij sterke trillingen is een antitrilling bevestigingsset leverbaar.
ZEER BELANGRIJK !! Zowel de zender als de ontvanger moet aan stabiele, ongebogen en loodrechte konstrukties bevestigd worden.De bevestigingsplaatjes zo monteren dat de justageschroeven toegankelijk blijven.Het aluminiumprofiel mag niet gebogen worden.Zoniet is een goede afregeling niet mogelijk.De ene zijde justeren terwijl aan de andere zijde de justageschroeven los zijn.
26
FIESSLER E L E K T R O N I K
Wandbevestiging:
M6 x 15 DIN 912 M6 M6
AA AA AA AA AA AA AA AA AA
DIN 934 DIN 127
50 x20 x 2
40 X 90 x 6 vlak
Afhankelijk van de nalooptijd van de machine
Machine
50 x20 x 2
40 X 90 x 6 vlak
M8 DIN 912 M8 DIN 127
27
Montage Bevestigingsmogelijkheden
A AA AAA AA AA AA AAA A
6 6.4
Konterschroeven met veerringen voor de justage van de ontvanger
FIESSLER
Montage
6
E L E K T R O N I K
Bevestigingsschroef
6.4
Indien het lichtgordijn samen met een zuil besteld wordt, dan zal het geheel voorgemonteerd geleverd worden
Konterschroeven Justierkonterschrauben 110
140
DIN 970-M8
1250
AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAA
10
10
1250
140
110
AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAA
200
200 Justierkonterschrauben Konterschroeven
27 R7
AAAAAAAAA AAAAAAAAA AAAAAAAAA AAAAAAAAA AAAAAAAAA 30AAAAAAAAA AAAAAAAAA AAAAAAAAA AAAAAAAAA AAAAAAAAA AAAAAAAAA AAAAAAAAA AAAAAAAAA M8 AAAAAAAAA AAAAAAAAA AAAAAAAAA AAAAAAAAA AAAAAAAAA AAAAAAAAA
AAAAAAAAA AAAAAAAAA AAAAAAAAA AAAAAAAAA AAAAAAAAA AAAAAAAAA AAAAAAAAA AAAAAAAAA AAAAAAAAA AAAAAAAAA AAAAAAAAA AAAAAAAAAAA AAAAAAAAA AAAAAAAAAAA AAAAAAAAA AAAAAAAAA AAAAAAAAA AAAAAAAAA AAAAAAAAA AAAAAAAAA AAAAAAAAA
200
Zuilbevestiging:
(Ansicht ohne LSUW) (Aanzicht zonder LSUW )
Zuil met spiegel
Zuil met fotocel LSUW
Deksel i.g.v spiegel
Front en deksel i.g.v spiegel Zuil voor LSUW en Spiegel
ZUILBEVESTIGING
Montagelangsgat voor M12 4 justageschroeven Montagelangsgat voor M12
Bodemplaat als boorsjabloon voor de bodembevestiging M12 en als tegenplaat voor de justageschroeven.
28
DIN 970-M8
Montage
FIESSLER E L E K T R O N I K
6.5
Met spiegels kan het beschermingsveld an een gevarllijke plaats heen geleid worden
ge ie
Gevaarlijke zone Gefahrenbereich
Gevaarlijke zone Gefahrenbereich
Sender Zender
Ontvanger Empfänger
Sp
l
Sp
ge
ie
ie
ge
l
Sp
l
Meersijdige beveiliging:
Werking met ombuigspiegels
6
Empfänger Ontvanger
Hierbij is de
Sender Zender
optische wet van kracht die zegt dat bij reflektie op een spiegel de invalshoek gelijk is aan de uitvalshoek.Bij een afleiding over een hoek van 90° moet de spiegel dus in een hoek van 45° gemonteerd worden.De spiegels voor de LSUW hebben hiertoe draaibare bevestigingsbeugels Verlies door omspiegeling:
Elke omspiegeling verzwakt het zendsignaal.Bij gebruik van spiegels moet dus de reikwijdte hoger gekozen worden. Het beste is bij de bestelling reeds op te geven of er gaat omspiegeld worden of niet.Zender, ontvanger en spiegel moeten met de waterpas gekontroleerd worden.
Montage:
Een bedrijfszekere werking van het lichtgordijn is alleen gewaarborgd bij een montage die voldoende stabiel is . Precieze gegevens omtrend de afregeling treft U aan in paragraaf 8
Montage van de LSUW en spiegelzuilen:
Met behulp van de meegeleverde zwarte bodemplaten kunnen de Bevestigingsgaten M12 voor de zuilen in de bodem geboord worden. Hierbij opletten dat de zuilen zoals AAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAA op de tekening AAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAA AA AAAAAA AAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAA AA AAAAAAAA AAAAAA AA AAAAA geplaatst worden. ZenAAAAAAAAAAAAAAAAAAAAAAAA A AAAAAAAAAA AAAAAAA AA AAAA A AAAAAAAAAAAAAAAAAAAAAAA AAAAA AAAAAAAA AAAAAAAAAAAAAAAAAAAAAAA AA AAAAA AAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAA AAAAAAA AAAAAAAA AAAA AAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAA AAAAAAAAAAAAAAAAAAAAAAA AA AAA AAAAAAAAAAA AAAAAAAA AAAA AAAAAAAAAAAAAAAAAAAAAAA AA AAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAA AAAAAAAAAA AAAAAAA AAAAAAAA AA AAAAA A AA der, ontvanger en AA A AAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAA AAAAAAAAAA AAAAAAA AAAA AA AAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAA AAAAAAAAAA AAAAAAA AAAAAAA AAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAA AAAAAAAAAA AAAAAAA AAAA AA AAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAA AAAAAAAAAA AAAAAAA AAAAA AAA spiegelzuilen moeten AAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAA AAAAAAA AAAAA AA AAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAA AAAAAAA AAAAA AAAAAAAAAAAAAAAAAAAAAAAA AAA AA AAAAAAAAAAAAAAAAAAAAAAAA AAAAAA AAAA met de waterpas op AAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAA dezelfde hoogte AAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAA gemonteerd worden. AAAAAAAAAAAAAAAAAAAAAAAA Voor de vertikale justage moeten de 4 justageschroeven 90o gebruikt worden. De zuilen kunnen door de montagegaten gedraaid worden.Wanneer de M8 AAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAA bevestigingsbouten aan AAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAA AAA AAAAAAAAAAAAAAAAAAAAAAA AAAAA AA AAA AAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAA AAAAAA AAA AAAA AA de trekstang onder het AAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAA AAAAAA AA AA A AA AAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAA AAAAAAAAAA AAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAA AAAAAA AAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAA AA AAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAA AAAAAAAAAA AAAAAA AAAA AAAAA AA deksel gelost worden AAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAA AAAAAAAAAA AAAAAA AAAAAA AAAAAAAA AAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAA AAAAAA AAAAAAA AA AAAAAAAAAAAAAAAAAAAAAAA AA AAAAAAAAAAAAA AA AAAAAAAAAAA AAAAAA AAAAAAA AAAA kan de spiegel gedraaid AAAAAAAAAAAAAAAAAAAAAAA AA AAAAAAAAAAA AAAAAAAAAA AAAAAA AAAAAAA AAAA AAAAAAAAAAAAAAAAAAAAAAA AA AAAAAA AAAAAA AAAAAAA AAAA AAAAAAAAAAAAAAAAAAAAAAA AAAAAA AAAAAAAAAAA AAA AA AAA AA AAAAA AAAAAAAA AAAAA AAAAAAAAAAAAAAAAAAAAAAA AAAA AAA AAAAAAAA AAAAAA worden. De fijnregeling AAAAAAAAAAAAAAAAAAAAAAA AAAAA AAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAA moet volgens hoofdstuk AAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAA 8 plaats vinden. Daarbij AAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAA moet het deksel weggenomen worden en na de justage er weer opgezet.
29
FIESSLER
Electrische aansluiting
7
Algemene tips
7.1
ELEKTRONIK
Elektrische gegevens Schakeltoestel: steeksokkel met schroefklemmen 0,75 mm2 230 V / 60 VA, zender/ontvanger: 3 / 4- polige stekker DIN 43650. Bedrijfsspanning: 230 V 50 Hz, - 15 %, + 10 % (115 VAC is optie) Stromaaupname: max. 0,09 A Ompoolbeveiliging: Niet tegen alle mogelijkheden van foute aansluiting Schakelfunktie: 2 potentiaalvrije, zelfbewaakte, mechanisch verbonden Normaal Open kontakten en (enkel bij LSUW NSR 3 -1 hulpopener). Schakelspanning: 250 V AC Schakelstroom: Max. 2 A, niet induktief . Lastkapaciteit: Bij induktieve last moeten er twee vonkblussingskomponenten gebruikt worden;Vrij van indukties. ( Vb. 0,22 µF, 220 Ω). Kortsluitvastheid: Gedwangen kontakten 3,15 A (M) Schakeltijden: LSUW NSR 3-1: LSUW N1: LSUW N1 K: LSUW N1 Duo: LSUW N1 Muting:
30 ms vanaf het onderbreken van het beschermingsveld tot het openen van de relaiskontakten. 20 ms vanaf het onderbreken van het beschermingsveld tot het openen van de relaiskontakten. 20 ms vanaf het onderbreken van het beschermingsveld tot het openen van de relaiskontakten. 20 ms vanaf het onderbreken van het beschermingsveld tot het openen van de relaiskontakten. 25 ms vanaf het onderbreken van het beschermingsveld tot het openen van de relaiskontakten.
Sectie van de aansluitkabels: 0,75 mm2 Kabelisolatie: Alle aansluitkabels moeten een isolatie hebben die bestand is tegen 250 V. Plaats van de ontvangeraansluitkabel: Zeker niet naast sterkstroomleidingen. Bij de LSUW NSR3-1 mag de kabel tussen 4,5,8,9 niet langer zijn dan 1 meter.De kabels voor de relaiskontrolefunktie moeten zo gelegd worden dat een kortsluiting onmogelijk is. Bij de LSUW NSR 3-1 mag er geen kortsluiting tussen de leidingen van klemmen 6/7 en de kontrolekontakten mogelijk zijn. Bij alle andere versie mag het niet mogelijk zijn een kortsluiting te hebben tussen de leidingen van de startknop en de klem 22 naar de kontrolekontakten. Opbouwhuis Leggen van de aansluitleidingen Tussen ontvanger en schakeltoestel mag de kabellengte maximaal10 m bedragen. Stoorgevoeligheid: Volgens EN 50100 is het niet toegelaten aan de gelijkspannuigsuitgang van het schakeltoestel aan te sluiten. Bescherming van het schakelgedeelte: Bedrijfstemperatuur: - 10 bis 55 °C Stockagetemperatuur: - 25 bis 70 °C Beschermingsgraad: IP 40, in optie IP 55 ( Bijv....) Ischeerstofklasse: E Bouwvorm: enkele isolatie opgelet: Daarenboven moeten alle andere betreffende normen en voorschriften met betrekking tot montage en gebruik ook nageleefd OPGELET : Een veilige werking is enkel gewaarborgd indien het lichtgordijn volgens n van de volgende schakelschema's werd aangesloten.Elke afwijking kan een gevaarlijke toestand veroorzaken. PLS - Sturing: Bij de aansturing van PLC sturingen mag een uitgangskanaal gebruikt worden voor de uitschakeling van de gevaarlijke beweging via de PLC, inzoverre de PLC volgens de vigerende ongevallenvoorschriften niet als zelfbewakend is getest.Het andere kanaal van het lichtgordijn moet via een relais direkt in de gevaarlijke beweging schakelen. 30
FIESSLER
Electrische aansluiting
7
E L E K T R O N I K
Aansluitschema LSUW NSR 3-1
7.2
Algemene tips
7.2.1
Aansluitschema:
AAAAAAAAAA AAAAAAAAAA AAAAAAAAAA AAAAAAAAAA AAAAAAAAAA AAAAAAAAAA AAAAAAAAAA AAAAAAAAAA B
Terugstellen van de LSUW NSR 3-1 telcyclus.
Brug: Kontakt open : 2 Taktlll Kontakt geloten : 1 Taktlll
D
LSUW NSR 3-1
11
10 9
8 7
Ventiel of relais veld.kontrolefunktie
Startknop
Aansluitsokkel
22 (intern)
zelfbewakend indiging van de arbeidscyclus
21
Hulpopener geopend bij vrij het veld vrij is
19
20
18
6
5
17 Zelfbewakend gesloten wanneer
16
4
15
Kanaal 2
3
14
Kanaal 1
2
+
13
AAAAAAAAAA AAAAAAAAAA AAAAAAAAAA AAAAAAAAAAAAAAAAAAAA 2
1
1
-
A
Lichtzender
230 V AC
12
3
2
1
C
N.O. kontakt
Lichtontvanger
L
N
PE
Funktiebeschrijving:
inbouwreikwijdte en het kleinst detekteerbare objekt zijn op het typenschild aangegeven.(Zie ook par. 4.1) Het arbeidsstroomcircuit dat de gevaarlijke beweging bedient wordt over klemmen 16 en 17 en 20-21 geschakeld.Er zijn twee potentiaalvrije, zelfbewaakte en mechanisch verbonden NO kontakten. En ook een hulpopener.De uitgangskontakten zijn potentiaalvrij en mogen met maximum 2A/250VAC of 60V DC,30W belast worden.Bij induktieve last moet er parallel op deze laatste vonkblussingsystemen geschakeld worden.(Bijv. 0,22 µF, 220 Ω)Aan de klemmen 4,5,6,7,8,9,10,D en 22 mag geen potentiaal aangesloten worden. Ter verhoging van de veiligheid moeten hier dubbele kontakten gebruikt worden. De gevaarlijke beweging mag enkel via 16-17 en 20-21 geschakeld worden. De uitgang 18-19 is een kontrole uitgang en mag niet gebruikt worden als start kontakt voor de gevaarlijke beweging. Bij laswerken aan de machine moeten de ontvanger en het schakelgedeelte van het net gescheiden worden. Anders kunnen lasstromen de elektronika van deze toestellen beschadigen.
31
Electrische aansluiting
FIESSLER E L E K T R O N I K
Funktie: Anwendung:
Voorbeeld:
7
7.2 Funktie "A" 7.2.2
Aansluitschema LSUW NSR 3-1
Beschermings en sturingsbedrijf bij cyclisch ingrijpen in het beschermingsveld (1- of 2-takt bedrijf ). Toepassing Taktbedrijf met 30 sec bewaking voor het sturen vanpersen met een tafelhoogte hoger dan 750 mm voor manuele inlegwerkzaamheden. De pers maakt een beweging na de eerste of de tweede ingreep in het beschermingsveld tijdens de stilstand in het bovenste dode punt. Indien tijdens de gevaarlijke beweging in het beschermingsveld ingegrepen wordt, dan loopt de pers weer terug naar het bovenste dode punt.Een nieuwe gevaarlijke beweging volgt slechts na bekrachtiging van de startknop en het testen van het lichtgordijn door 1 of 2 maal in het veld in te grijpen.
Mode"A" mag niet gebruikt worden wanneer men door het beschermingsveld kan stappen. (zie 6.2) Aansluitschema:
Zekeringen zo dimensioneren dat het aan elkaar lassen van de kontakten efficient vermeden wordt
M 2,0 A
X X
L1 = 230 V AC Terugstellen van de LSUW NSR 3-1 telcyclus Drukknop of Eindschakelaar in het ounderste dode punt
Kc1
Zelfbewakend gesloten wanneer het veld vrij is
10 9
Hulpopener geopend bij vrij veld.
8
Brug: 1-Takt
21 20
16
Kc2
4
15 Kanaal 1
3
14 Kanaal 2
2
13 +
Vonkblussing
AAAAAAAAA AAAAAAAAA AAAAAAAAA AAAAAAAAAA AAAAAAAAAA 2
1
voor de onderbreking van de gevaarlijke beweging
17
5
Lichtzender
X=
18
6
Kc1
X X
22
19
zelfbewakend gesloten wanneer het veld vrij is
7
Kc2
D
LSUW NSR 3-1 (intern)
11
Zonder brug: 2-Takt
Startknop
Aansluitsokkel
B
1
12
A
-
2
3
1
C
Intern niet verbanden
Lichtontvanger Kc1
Kc2
N
PE
Funktiebeschrijving:
Na het inschakelen van de pers moet door het ingrijpen in het beschermingsveld een aanlooptest volgen.Na het bekrachtigen van de startknop, bij vrij beschermingsveld en eenmalig (resp. tweemalig) onderbreken en weer vrijgeven sluiten kontakten 16-17 en 20-21 zich en opent 18-19.Het kontrolekontakt 6-7 werkt als volgt: de gevaarlijke beweging kan enkel starten als bij een ingreep in het beschermingsveld de beide relais Kc1 en Kc2 afgevallen zijn en het veld vrij is.Bij het inleiden van de sluitbeweging door relais Kc1 en Kc2 moeten telkens NO kontakten van Kc1 en Kc2 in serie geschakeld worden. De uitgang 18-19 is een kontroleuitgang en mag niet gebruikt worden als startkontakt voor de gevaarlijke beweging. Na 30 sec blokkeert de tijdfunktie de WAV, dit indien er ondertussen geen ingreep in het beschermingsveld of een vrijgave van het veld komt. Een korte onderbreking van het kontakt 10-11 door een schakelaar aan de machine zorgt voor het terugzetten van het telwerk.(nodige tijd ongeveer 20 msec.) Met de aansluitingen Startknop (klem D-22) , kontrolekontakt
32
(klem 6-7) en de reset van het telwerk (klemmen 1011) worden kleine stromen en spanningen geschakeld. Deze kontakten moeten potentiaalvrij zijn en juist gedimensioneerd. Bij het omschakelen van de ene mode naar de andere moet volgens prEN50100 de WAV geaktiveerd worden. Die kan gerealiseerd worden door de zender af te schakelen tijdens de omschakeling.
Electrische aansluiting
FIESSLER E L E K T R O N I K
Funktie: Toepassing:
Voorbeeld:
7
7.2 Funktie "B" 7.2.3
Aansluitschema LSUW NSR 3-1
Beschermingsbedrijf met Wederaanloopvergrendeling tijdens de volledige cyclus Toepassingen met cyclisch ingrijpen met de hand in het beschermingsveld. Siehe z.B. ZH 1/281 und ZH 1/597. Persen met een tafelhoogte lager dan 750 mm zonder bijkomende beschermingsinrichting en zonder sturing. Verder stansautomaten waarbij men zonder de cyclische test kan werken.
Aansluitschema:
Zekeringen zo dimensioneren dat het aan elkaar lassen van de kontakten efficientvermeden wordt !
M 2,0 A
X X
L1 = 230 V AC
Kc1 Startknop
B
Aansluitsokkel
LSUW NSR 3-1
D
11
(intern)
22
10
Zelfbewakend gesloten wanneer het veld vrij is
9
Hulpopener geopend bij vrij veld
8 7 Kc1
Kc2
Lichtzender
zelfbewakend gesloten wanneer veld vrij is
1
X X X = voor de onderbreking van de gevaarlijke beweging
21 20 19
het
18
6
17
5
16
4
15 Kanaal 1
3
14 Kanaal 2
2
13
+
1
12
-
A
C
AAAAAAAAAA AAAAAAAAAA AAAAAAAAAA AAAAAAAAA 2
Kc2
intern niet verbanden
Vonkblussing
3 2
1
Lichtontvanger
Kc1
Kc2
N
PE
Funktiebeschrijving:
Na het inschakelen van de pers moet door het ingrijpen in het beschermingsveld een aanlooptest volgen.Na het bekrachtigen van de startknop, bij vrij beschermingveld en eenmalig (resp. tweemalig ) onderbreken en weer vrijgeven sluiten kontakten 1617 en 20-21 zich en opent 18-19. De machine stopt wanneer in het beschermingsveld van de machine werd ingegrepen. Een nieuwe start volgt eerst wanneer er op de startknop werd gedrukt. Het kontrolekontakt 6-7 werkt als volgt: de gevaarlijke beweging kan enkel starten als bij een ingreep in het beschermingsveld de beide relais Kc1 en Kc2 afgevallen zijn en het veld vrij is.Bij het inleiden van de sluitbeweging door relais Kc1 en Kc2 moeten telkens NO kontakten van Kc1 en Kc2 in serie geschakeld worden. De uitgang 18-19 is een kontroleuitgang en mag niet gebruikt worden als startkontakt voor de gevaarlijke beweging. Met de aansluitingen "Startknop (klem D-22)", kontrolekon takt ( klem 6-7) en de reset van het telwerk (klemmen 10-11) worden kleine stromen en spanningen geschakeld. Deze kontakten moeten potentiaalvrij zijn en juist gedimensioneerd.
33
De startknop is te monteren op een plaats waar de gebruiker de gevaarlijke zone goed kan overschouwen. Op de startknop drukken vanuit de gevaarlijke zone mag niet mogelijk zijn zonder in het veld in te grijpen.
Electrische aansluiting
FIESSLER E L E K T R O N I K
Funktie:
7
7.2 Funktie "B1" 7.2.4
Aansluitschema LSUW NSR 3-1
Beschermingsbedrijf met Weder Anloopvergrendeling tijdens de arbeidsbeweging . Mode B1 mag niet gebruikt worden indien het mogelijk is door het gordijn te kruipen of te stappen. (zie ook 6.2)
Aansluitschema:
Zekeringen zo dimensioneren dat het aan elkaar lassen van de kontakten efficient vermeden wordt
M 2,0 A
X X
L1 = 230 V AC
Kc1 Startknop Aansluitsokkel
B 11
zelfbewakend kontakt gesloten wanneer veld vrij is.
10
Hulpopener geopend bij vrij veld.
8 7
Lichtzender
22
1
zelfbewakend van de gevaarlijke kontakt beweging
21
19
17
5
16
4
15 Kanaal 1
3
14 Kanaal 2
2
13
+
1
12
-
A
C
AAAAAAAAAA AAAAAAAAAA AAAAAAAAAA AAAAAAAAA 2
X X X = voor de onderbreking
18 Zelfbewakend N.O. kontakt
6
Kc2
S
20
9
Kc1
Kc2
D
LSUW NSR 3-1 (intern)
intern niet verbanden
Vonkblussing
3 2
1
Lichtontvanger
Kc1
Kc2
N
PE
Funktiebeschrijving:
Indien tijdens de gevaarlijke beweging in het veld ingegrepen wordt zal de machine stoppen.Verder werken is enkel mogelijk na het drukken van de startknop. In de rusttoestand van de machine (schakelaar S geopend) kan op elk ogenblik in het veld ingegrepen worden zonder dat er een nieuw druk op de startknop nodig is.Na het inschakelen van de pers moet door het ingrijpen in het beschermingsveld een aanlooptest volgen. Na het bekrachtigen van de startknop, bij vrij beschermingsveld en eenmalig onderbreken en weer vrijgeven sluiten kontakten 1617 en 20-21 zich en opent 18-19.De machine stopt wanneer in het beschermingsveld van de machine werd ingegrepen. Een nieuwe start volgt eerst wanneer er op de startknop werd gedrukt. Het kontrolekontakt 6-7 werkt als volgt: de gevaarlijke beweging kan enkel starten als bij een ingreep in het beschermingsveld de beide relais Kc1 en Kc2 afgevallen zijn en het veld vrij is.Bij het inleiden van de sluitbeweging door relais Kc1 en Kc2 moeten telkens NO kontakten van Kc1 en Kc2 in serie geschakeld worden. De uitgang 18-19 is een kontroleuitgang en mag niet gebruikt worden als startkontakt 34
voor de gevaarlijke beweging. Met de aansluitingen "Startknop (klem D-22)", kontrolekontakt (klem 6-7) en de reset van het telwerk (klemmen 10-11) worden kleine stromen en spanningen geschakeld. Deze kontakten moeten potentiaalvrij zijn en juist gedimensioneerd.
Electrische aansluiting
FIESSLER E L E K T R O N I K
Funktie:
Toepassing:
7.2 Funktie "C" 7.2.5
Aansluitschema LSUW NSR 3-1
Beschermingsbedrijf zonder Weder Aanloopvergrendeling en met relaiskontrolefunktie aan machines (ZH 1/597). Gewoon beschermingsbedrijf en wanneer een wederaanloopverrendelingin de machine gewenst is. Mode C niet mag gebruikt worden indien het mogelijk is van door het gordijn te kruipen of te stappen.(zie ook 6.2)
Aansluitschema:
Zekeringen zo dimensioneren dat het aan elkaar lassen van de kontakten efficient vermeden wordt
M 2,0 A
X X
L1 = 230 V AC
Kc1
B 11 10
Aansluitsokkel
LSUW NSR 3-1 (intern) zelfbewakend N.O. kontakt gesloten wanneer het veld vrij is
9
7 Kc1
gesloten wanneer het veld vrij is
6
Kc2
Lichtzender
1
X X X = voor de onderbreking
22
van de gevaarlijke beweging
21
19 18 17
5
16
4
15 Kanaal 1
3
14 Kanaal 2
2
13
+
1
12
-
AAAAAAAAAA AAAAAAAAAA AAAAAAAAAA AAAAAAAAA 2
Kc2
D
20 Hulpopener geopend bij vrij veld.
8
A
Vonkblussing
3 2
1
C
intern niet verbanden
N
PE
Funktiebeschrijving:
7
Na het inschakelen van de pers moet door het ingrijpen in het beschermingsveld een aanlooptest volgen.Na het weer vrijgeven sluiten kontakten 16-17 en 20-21 zich en opent 18-19.De machine stopt wanneer in het beschermingsveld van de machine werd ingegrepen. Kontakten 16-17 en 20-21 openen. 18-19 sluiten hierbij.Het kontrolekontakt 6-7 werkt als volgt: de gevaarlijke beweging kan enkel starten als bij een ingreep in het beschermingsveld de beide relais Kc1 en Kc2 afgevallen zijn en het veld vrij is. Bij het inleiden van de sluitbeweging door relais Kc1 en Kc2 moeten telkens NO kontakten van Kc1 en Kc2 in serie geschakeld worden. De uitgang 18-19 is een kontroleuitgang en mag niet gebruikt worden als startkontakt voor de gevaarlijke beweging. Met de aansluitingen kontrolekotakt( klem 6-7)worden kleine stromen en spanningen geschakeld. Deze kontakten moeten potentiaalvrij zijn en juist gedimensioneerd.
35
Lichtontvanger
Kc1
Kc2
Electrische aansluiting
FIESSLER E L E K T R O N I K
Funktie: Toepassing:
7
7.2 Funktie "D" 7.2.6
Aansluitschema LSUW NSR 3-1
Beschermingsbedrijf met cyclische testing en Weder Aanloopvergrendeling. Bijvoorbeeld om de achterzijde van een pers te beschermen. zie ook ZH 1/281 Hierbij zal niet cyclisch in het veld worden ingegrepen. Mode D mag niet gebruikt worden indien het mogelijk is van door het gordijn te kruipen of te stappen.(zie ook 6.2)
Aansluitschema: M 2,0 A
Zekeringen zo dimensioneren dat het aan elkaar lassen van de kontakten efficient vermeden wordt
L1 = 230 V AC Terugstellen van de telcyclus. Eindschakelaar of druk knop in het onderste dode punt
Kc1 Startknop
B
Aansluitsokkel
LSUW NSR 3-1
11
Kc2
D
X X
22
X=
21
10 (intern)
9
gesloten wanneer
20
8
Hulpopener geopend bij vrij veld.
19
gesloten wanneer het veld vrij is
17
7 Kc1
X X
6
voor de onderbreking van de gevaarlijke beweging
18
5
16
4
15 Kanaal 1
3
14 Kanaal 2
2
13
1
12
A
C
Kc2 Testschakelaar 230V 0,1A of machinetest Zelfbewakend N.O. kontakt. Tenminste 60 msec.
2
Lichtzender
1
Vonkblussing‘
AAAAAAAAAA AAAAAAAAAA AAAAAAAAAA intern niet verbanden
+ -
3 2
1
Lichtontvanger
Kc1
Kc2
N PE
Funktiebeschrijving:
Bij elke gang van de machine wordt er in het veld van de machine ingegrepen en test het lichtgordijn zichzelf. Bij automatische werking blijft deze test soms urenlang achterwege. Nochtans is een zelftest voor elke gevaarlijke beweging voorgeschreven.Een schakelaar aan de machine reset het telwerk door een kortstondige onderbreking aan klemmen 10-11 (ca. 20 msec)Hierbij schakelen de uitgangen 16-17 en 20-21 kortstondig. Een wisimpuls onderbreekt kortstondig de stroomtoevoer aan de zender. Na het inschakelen van de pers moet door het ingrijpen in het beschermingsveld een aanloop test volgen.Na het bekrachtigen van de startknop, bij vrij bescher mingsveld enmalig onderbreken en weer vrijgeven sluiten kontakten 16-17 en 20-21 zich en opent 18-19. Het kontrolekontakt 6-7 werkt als volgt: de gevaarlijke beweging kan enkel starten als bij een ingreep in het beschermingsveld de beide relais Kc1 en Kc2 afgevallen zijn en het veld vrij is. Bij het inleiden van de sluitbeweging door relais Kc1 en Kc2 moeten telkens NO kontakten van Kc1 en Kc2 in serie geschakeld worden. De uitgang 18-19 is een kontroleuitgang en mag niet gebruikt worden als startkontakt 36
voor de gevaarlijke beweging. Na 30 sec blokkeert de tijdfunktie de WAV, dit indien er ondertussen geen ingreep in het beschermingsveld of een vrijgave van het veld komt. Een korte onderbreking van het kontakt 10-11 door een schakelaar aan de machine zorgt voor het terugzetten van het telwerk.(nodige tijd ongeveer 20 msec.) Met de aansluitingen "Startknop (klem D-22)", kontrolekontakt( klem 6-7) en de reset van het telwerk (klemmen 10-11) worden kleine stromen en spanningen geschakeld. Deze kontakten moeten potentiaalvrij zijn en juist gedimensioneerd.
Electrische aansluiting
FIESSLER E L E K T R O N I K
Funktie: Toepassing:
Voorbeeld:
Aansluitschema LSUW N1
7 7.3
Beschermingsbedrijf met Aanloop en Weder Aanloopvergrendeling en ventielof relaiskontrole. Voor de beveiliging van begaanbare zones. Toepassingen met cyclisch ingrijpen in het beschermingsveld.
Beveiliging van een robot. Persen met tafelhoogte <750 mm
Aansluitschema: M 2,0 A
L1 = 230 V AC
X X X Startknop
B
Kc1 Kc2
Aansluitsokkel
LSUW N 1
D
(intern )
22
gesloten wanneer het veld vrij is
21
1 1 10 9
Kc1
X X X X=
Kc2
voor de onderbreking van de gevaarlijke beweging
20
8
19
7
18
6
2
16 Kanaal 1
4
1
17
Zelfbewakend gesloten wanneer het veld vrij is
5
Lichtzender
3
15
Vonkblussing
14 +
2
Kanaal 2
13
AAAAAAAAA AAAAAAAAA AAAAAAAAA AAAAAAAAAAAAAAAAAAAAAAAA 1
12
A
C
intern niet verbanden
-
3
2
1
Lichtontvanger
Kc 1
Kc 2
N
PE
Funktiebeschrijving:
Na het aanleggen van de netspanning begint vooreerst de rode LED"onderbroken" op de ontvanger te branden. Na het drukken van de startknop is ook de zender ingeschakeld.Ter kontrole brandt de LED op de zender. De LED op de ontvanger schakelt dan over op groen.Op het schakelgedeelte branden dan de LED's"vrij".Bij het lossen van de startknop schakelen de uitgangen 16-17 en 20-21 door. De LED"uitgang vrij" brandt op het schakelgedeelte.Bij een ingreep in het beschermingsveld schakelen de uitgangen 16-17 en 20-21 af.Pas na het weer vrij komen van het beschermingsveld en het drukken van de startknop is het lichtgordijn weer ingeschakeld.De NCkontakten van relais Kc1 en Kc2 in serie met de startknop dienen als relais of ventielbewaking.
37
Tip: Bij de justage dient de startknop voortdurend gedrukt of overbrugd te worden.De startknop is te monteren op een plaats waar de gebruiker de gevaarlijke zone goed kan overschouwen. Op de startknop drukken vanuit de gevaarlijke zone mag niet mogelijk zijn zonder in het veld in te grijpen.
Electrische aansluiting
FIESSLER E L E K T R O N I K
Funktie: Toepassing:
Voorbeeld:
Aansluitschema schakelunit LSUW N1 K
7 7.4
Beschermingsbedrijf met Aanloop en Weder Aanloopvergrendeling en ventielof relaiskontrole. Voor de beveiliging van begaanbare zones. Toepassingen met cyclisch ingrijpen in het beschermingsveld.
Beveiliging van een robot. Persen met tafelhoogte <750 mm
Aansluitschema:
output free sortie libre
3
18
19
14
12
15
L1
230V AC -15% +10%
N
N
L1 2
1
Lichtzender
LSUW
24V
-
13
(Kanaal 2)
2
Achtung Attention Attention
(Kanaal 1)
1
Ausgang frei
A1
AA AA
Vor Abziehen der Klemmleiste Netzspannung abschalten! Turn off the supply voltage ! Couper l'alimentation !
22
D
17
16
kc1
TÜV Rheinland
21
20
kc2
A2
1
2
................................. 20 mS -10É + 55 ¡C IP 20 230 VAC -15% +10 %, 50Hz 2 A, 250 VAC
L1
3
Lichtontvanger LSUW
Vonkblussing
restart interlock interdiction de redémarrage
Schaltgerät BWS Typ 4 Switching unit ESPE Type 4 Boîtier de commande ESPS Type 4
No./annŽe de fabrication temps de rŽponse temp. degrŽ de protection tension d'alimentation charge contact maxi.
M 2A
Typ: LSUW N1 K 230V Wiederanlaufsperre
No./year of construction response time temp. enclosure rating supply voltage contact max.
M 2A
free / interrupt libre / interrompu
frei / unterbrochen
Kastellstr.9 73734 Esslingen Tel. 0711/ 345 19 44
Nr./Baujahr Ansprechzeit Temp. Schutzart Versorgung Kontaktbel.
power tension
Netz
ELEKTRONIK
Startknop
FIESSLER
kc1
x x x kc1
kc2
N
X= voor de onderbreking van de gevaarlijke beweging
kc2
x x x
Funktiebeschrijving:
Na het aanleggen van de netspanning begint vooreerst de rode LED "onderbroken" op de ontvanger te branden. Na het drukken van de startknop is ook de zender ingeschakeld.Ter kontrole brandt de LED op de zender. De LED op de ontvanger schakelt dan over op groen.Op het schakelgedeelte branden dan de LED's"vrij".Bij het lossen van de startknop schakelen de uitgangen 16-17 en 20-21 door. De LED"uitgang vrij" brandt op het schakelgedeelte.Bij een ingreep in het beschermingsveld schakelen de uitgangen 16-17 en 20-21 af.Pas na het weer vrij komen van het beschermingsveld en het drukken van de startknop is het lichtgordijn weer ingeschakeld.De NCkontakten van relais Kc1 en Kc2 in serie met de startknop dienen als relais of ventielbewaking.
38
Tip: Bij de justage dient de startknop voortdurend gedrukt of overbrugd te worden.De startknop is te monteren op een plaats waar de gebruiker de gevaarlij¨ke zone goed kan overschouwen. Op de startknop drukken vanuit de gevaarlijke zone mag niet mogelijk zijn zonder in het veld in te grijpen.
Electrische aansluiting
FIESSLER E L E K T R O N I K
Aansluitschema schakelunit LSUW N1 Duo Beveiliging van een gevaren zone met 2 schermen
Toepassing:
7 7.5 7.5.1
Beveiliging van een gevaren zone met 2 schermen (1 Start-Taster). Opgelet zie punt 6.2
Aansluitschema:
M 2,0 A
L1 = 230V AC
Startknop
X
X
X
X
X
X
Kc1 Aansluitsokkel LSUW N1 Duo
B 11
(intern)
22
10
gesloten wanneer het veld vrij is
21
9
Kanal 2 6
3 2
7
1
Lichtzender
LS A Zelfbewakend gesloten wanneer het veld vrij is
Kanal 1 5 B
1
1
A
2
1
17
15 Kanaal 1
3
A
Lichtzender
18
16
4
14
2 2
X= voor de onderbreking van de gevaarlijke beweging
19
LS B +
Kc2
Kc2
20
8
Lichtontvanger B
Kc1
D
Kanaal 2
+
Vonkblussing
13
AAAAAAA AAAAAAA AAAAAAA 12
-
3 2
1
C
Lichtontvanger A
intern niet verbanden
N PE
Funktiebeschrijving:
Beveiligen van gevaarlijke zone die van zijde toegangkelijk is maar met 2 fotocellen beveiligd is.vorige seiten Na het aanleggen van de netspanning begint vooreerst de rode LED "onderbroken" op de ontvanger te branden.Na het drukken van de startknop zijn de zenders A en B ingeschakeld.Ter kontrole branden de LED's op de zenders. De LED op de ontvangers schakelen dan over op groen. Op het schakelgedeelte branden dan de LED's"vrij".Bij het lossen van de startknop schakelen de uitgangen A 16-17 en 20 21 en de uitgangen "B" 8-9 en 10-11 door. De LED "uitgang vrij" brandt op het schakelge deelte.De uitgangskontakten van beide veiligheidsfotocellen zijn in serie geschakeld. Bij een ingreep in een van beide beschermingsvelden vallen de relais Kc1 en Kc2 af. Pas na het weer vrij komen van het beschermingsveld en het drukken van de startknop is het lichtgordijn weer ingeschakeld.De NC kontakten van relais Kc1 en Kc2 in serie met de startknop dienen als relais of ventielbewaking.
39
Kc 1
Kc 2
Tip: Bij de justage dient de startknop voortdurend gedrukt of overbrugd te worden.De startknop is te monteren op een plaats waar de gebruiker de gevaarlijke zone goed kan overschouwen. Op de startknop drukken vanuit de gevaarlijke zone mag niet mogelijk zijn zonder in het veld in te grijpen.
Electrische aansluiting
FIESSLER E L E K T R O N I K
Toepassing:
7
7.5 Beveiliging van twee onafhankelijke gevaarlijke zone's 7.5.2 Aansluitschema schakelunit LSUW N1 Duo
Beveiligen van twee aparte van elkaar gescheiden, onafhankelijke gevaarlijke zones. Beveiliging van gevaarlijke zone die van twee zijden toegankelijk is Opgelet zie punt 6.2
Aansluitschema:
M 2,0 A
Startknop A X
X
Kc 3
Aansluitsokkel LSUW N1 Duo
B
Kc 4
Startknop B X
11
X
10
voor de onderbreking van de gevaarlijke beweging Lichtontvanger B
2
+ Kanal 2
3 1
Kanal 1 -
Lichtzender B
Kc 3
Funktiebeschrijving:
D
gesloten wanneer het veld vrij is
21
9
20
8
19
7 6
LS B
X=
Kc 2 22
X
X
voor de onderbreking van de gevaarlijke beweging
Lichtzender A
LS A
Zelfbewakend gesloten wanneer het veld vrij is
18
5
16
4
15
3
14
Kanal 2
2
1
17
Kanal 1 +
Vonkblussing
13
AAAAA AAAAA AAAAAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAAAAA 1
Vonkblussing
PE
X
Kc 1
Kc 1
(intern)
2
2
N
X
Kc 2
Kc 4
X
X
X
Kc 3
X=
X
L1 = 230V AC
1
12
A
C
intern niet verbanden
Kc 4
Na het aanleggen van de netspanning begint vooreerst de rode LED "onderbroken" op de ontvanger te branden. Na het drukken van de startknop zijn de zenders A en B ingeschakeld. Ter kontrole branden de LED's op de zenders. De LED op de ontvangers schakelen dan over op groen.Op het schakelgedeelte branden dan de LED's"vrij".Bij het lossen van de startknop schakelen de uitgangen 16-17 en 20-21 door en dit zowel van A als B. De LED"uitgang vrij" brandt op het schakelgedeelte.De uitgangskontakt van beide veiligheidsfotocellen zijn in serie geschakeld. Bij een ingreep in een van beide beschermingsvelden vallen de relais Kc1 en Kc2 af. Pas na het weer vrij komen van het beschermingsveld en het drukken van de startknop is het lichtgordijn weer insgeschakeld.De NC kontakten van relais Kc1 en Kc2 in serie met de startknop dienen als relais of ventielbewaking.
40
-
3
2
1
Lichtontvanger A
Kc 1
Kc 2
Tip: Bij de justage dient de startknop voortdurend gedrukt ofoverbrugd te worden. De startknop is te monteren op een plaats waar de gebruiker de gevaarlijke zone goed kan overschouwen. Op de startknop drukken vanuit de gevaarlijke zone mag niet mogelijk zijn zonder in het veld in te grijpen.
FIESSLER
Electrische aansluiting
E L E K T R O N I K
Aansluitschema schakelunit LSUW N1 Muting
Funktie:
Toepassing:
7
7.6 Algemene tips 7.6.1
Dit schakelgedeelte bevat een "Mutingunit". Deze laat toe de veiligheidsfotocellen kort te overbruggen tijdens het transport van materiaal in en uit een fabrikagecel.Tevens laat deze unit toe het onderscheid te maken tussen mens en een vorkheftruck.
Het schakelgedeelte LSUW N1 MUTING is van toepassing wanneer er een onderscheid moet gemaakt worden tussen een mens en een machine.
Aansluitschema: M 2,0 A
L1 = 230 V AC
Startknop
D
(intern
19
7
18 Zelfbewakend gesloten wanneer het veld vrij is
5
X
X
Lichtzender
2
17
1
16
4 3 2
X
voor de onderbreking van de gevaarlijke beweging
20
8
6
X=
Kc2
21
) gesloten wanneer het veld vrij is
9
Kanaal 2
15
Kanaal 1
14
+
Vonkblussing
13
AAAAAA 1
A
Kc1
22
10
X
Kc2
LSUW N 1 Muting
11
Mutingsignaallamp
X
Kc1
Aansluitsokkel
B
Alarm
X
intern niet verbanden
3
-
12
2
1
C Lichtontvanger
Kc 1
Kc 2
AAAAAAAAAAAAAAAAAAAAAA N
PE
Funktiebeschrijving:
vorige seiten Funktiebeschrijving In kombinatie met vertikaal geplaatst lichtgordijn LSUW en vier zgn. Mutingsensoren (zie verder) of horizontaal geplaatst lichtgordijn LSUW kan het onderscheid gemaakt worden tussen een mens en een palet of een vorkheftruck.Om de Mutingfunktie te verwezenlijken zijn volgende komponenten nodig.1. Schakelgedeelte LSUW N1 Muting2. Ongevallenlichtgordijn(Zender, Ontvanger) bijv. LSUW 895/3. Vier Mutingsensoren bijv. fotocellen, induktieve sensoren, nokkenschakelaars of tweekanalige veiligheidsfotocellen zoals bijv. LSUW 1135/2, mOm te verhinderen dat het lichtgordijn door een fout op twee Mutingsensoren of door moedwillig saboteren voortdurend overbrugd wordt, is een tijdfunktie verbonden aan het systeem.Deze tijd is instelbaar van 3-90 sec en is bij de fabriek in te stellen volgens de wensen van de klant.De unit kan zo geschakeld worden dat het mogelijk is te werken zonder de tijdbewaking.!De Mutingsignaallamp (max 230V 60W in 24 VAC of DC max. 0,5A) is bewaakt door het lichtgordijn.Indien ze niet aangesloten is of ze is defekt dan kan het lichtgordijn niet bewaakt worden.Bij het aanleggen van de spanning komt er dan alarm.Dit alarm kan enkel gereset worden door het drukken van de startknop(sleutelversie in dit geval).
Voor toepassingen waarbij enkel een alarm gegeven wordt en er geen onderbreking van de gevaarlijke beweging mogelijk is,moet als startschakelaar een sleutelschakelaar gebruikt worden.Het verwijderen van de sleutel mag dan enkel mogelijk zijn in geopende toestand. Voor het draaien aan de startsleutel moet men kontroleren of er zich in de gevaarlijke zone geen per soon bevindt. De sleutelschakelaar moet op een plaats aangebracht zijn van waar men een overzicht heeft over de gevaarlijke zone. LSUW N1
LS 1B / LS 2B
LS 1A / LS 2A Palette
A
De afstand S moet kleiner zijn of gelijk aan de lengte van de palet, de vorkheftruck of de reflektorband.
S
LSUW
LS 1B / LS 2B
LS 1A / LS 2A
A
S
De afstand S moet zo groot zijn dat een gelijktijdig onderbreken van de Mutingsensoren LS1/LS2 en LS1A/LS2A door een mens ounmoeglijk is.
LSUW
LS 1A / LS 2A
LS 1B / LS 2B
H
A 41
S
Ventueel moeten de afstanden H of S vergroot worden.
FIESSLER
Electrische aansluiting
E L E K T R O N I K
Aansluitschema schakelunit LSUW N1 Muting
Toepassing:
7
7.6 Mutingfunktie, 4 Mutingsensoren en tijdcontr. 7.6.2
Voorraden beveiligen, palettentransportsystemen.
Aansluitschema:
+
M 2,0 A
LS 1A
+ -
LS 1B
LS - Spannungsversorgung = 24V ungeregelt
L1 = 230 V AC
Start-Taster
LSUW N 1 Muting
D
11
Alarm
Kc1
22 (intern
10
X=
Kc2
21
gesloten wanneer ) het veld vrij is
9
X
X
X
X
X
Kc2
Aansluitsokkel
B
X Kc1
Schützenüberwachung
20
voor de onderbreking van de gevaarlijke beweging
Mutinglampe 8
19
7
18
6
LS 2A
+ -
1
16
4
15
3
14 +
2
LS 2B
2
17
Zelfbewakend gesloten wanneer het veld vrij is
5 +
Lichtzender
Kanaal 2
Kanaal 1
Vonkblussing
13
AAAAAAA AAAAAAA AAAAAAAAAAAAAAAAAAAAAAA 1
A
12
intern niet verbanden
-
3
2
1
C
Lichtontvanger
Kc 1
Kc 2
N
PE
Funktiebeschrijving:
Wanneer de Muting sensoren LS1A/LS2 en LS1 en LS2A allen tesamen open zijn is het lichtgordijn overbrugd.De Muting sensoren mogen echter maar gedurende de ingestelde tijd open blijven.Tijdens deze toestand kan het lichtgordijn voor ongevallenbeveiliging onderbroken worden zonder dat er aan alarm uitgelokt wordt. Er komt wel een alarm wanneer het lichtgordijn onderbroken wordt en er gelijktijdig geen overbrugging via de Mutingsensoren plaats grijpt.De kontakten 20 - 21 en 16 11 vallen dan af.
Een nieuwe start en desaktivering van het alarm is mogelijk bij een vrij beschermingsveld dooor het draaien aan de sleutelschakelaar. Voor het draaien aan de start sleutel steeds kontroleren of er geen persoon in de gevaarlijke zone is. Min - en plusleidigen meeten uit veiligheidsverzweigingen aangebracht worden zools in het schakelschema aangegeven. De aansluitingen voor LS 1 A/B en LS 2 A/B zijn met ajzarteleidigen uit te voeren. De kountakten van de Muting - kanalen kunnen ook door eindschakelaars verwangen worden.
LSUW
LSUW
Alarm
AAAAAAAAAAA AAAAAAAAAAA AAAAAAAAAAA AAAAAAAAAAA AA AA AAA
LS 1B / LS 2B
LS 1A / LS 2A
LS 1 A/ LS 2A
LS 1B / LS 2B
Palette
Transportband
42
AAA AA
Transportband
AA AA
FIESSLER
Electrische aansluiting
E L E K T R O N I K
Aansluitschema schakelunit LSUW N1 Muting
Toepassing:
7
7.6 Mutingfunktie, 4 Muting sensoren zonder tijdcontr 7.6.3
Voorraden beveiligen wanneer de vorkheftruck mag parkeren in de inrijzone.
Schakelschema:
+
M 2,0 A
LS 1A
-
L1 = 230 V AC
Startknop
+ -
B
Alarm
LSUW N 1 Muting
D
11
Mutinglampe
(intern)
9
X
Lichtzender
18 2
17
5
16
LS 2A +
4
15
-
3
14 +
LS 2B
X
19
Zelfbewakend gesloten wanneer het veld vrij is
6
-
X
van de gevaarlijke beweging
Schützenüberwachung
20
gesloten wanneer het veld vrij is
7
+
X
X= voor de onderbreking
Kc2
21
überwachter
8
S - Spannungsversorgung 24V ungeregelt
Kc1
22
10
X
Kc2
Aansluitsokkel
LS 1B
X Kc1
2
Kanaal 2
Kanaal 1
1
Vonkblussing
13
AAAAAA AAAAAA AAAAAAAAAAAAAAAAAAAA 1
A
12
N.O. kontakt
-
3
2
1
C
Lichtontvange r
Kc 1
N
Kc 2
PE
Funktiebeschrijving:
Wanneer de Muting sensoren LS1A/LS2 en LS1 en LS2A allen tesamen gesloten zijn is het lichtgordijn overbrugd.Tijdens deze toestand kan het lichtgordijn voor ongevallenbeveiliging onderbroken worden zonder dat er aan alarm uitgelokt wordt. Er komt wel een alarm wanneer het lichtgordijn onderbroken wordt en er gelijktijdig geen overbrugging via de Mutingsensoren plaats grijpt.De kontakten 20 - 21 en 16 -17 vallen dan af.
Een nieuwe start en desaktivering van het alarm is mogelijk bij een vrij beschermingsveld door het draaien aan de sleutelschakelaar. Voor het draaien aan de start sleutel steeds kontroleren of er geen persoon in de gevaarlijke zone is. Min - en plusleidigen meeten uit veiligheidsverzweigingen aangebracht worden zools in het schakelschema aangegeven. De aansluitingen voor LS 1 A/B en LS 2 A/B zijn met ajzarteleidigen uit te voeren. De kountakten van de Muting - kanalen kunnen ook door eindschakelaars verwangen worden.
LSUW
LSUW Alarm
AAAAAAAAAAA AAAAAAAAAAA AAAAAAAAAAAAAAA AAAAAAAAAAAAAAA
LS 1A / LS 2A
LS 1B / LS 2B
LS 1A / LS 2A
Reflektorband
43
A
LS 1B / LS 2B
8
Inbedrijfstellen
FIESSLER E L E K T R O N I K
Instelaanwijzingen
8.1
Justagehulplamp:
Om het afregelen van de lichtgordijnen voor ongevallenbeveiliging LSUW over grotere afstanden te vereenvoudigen werd er door FIESSLER op elk toestel een projektor geplaatst.Bestaande uit een laagspanningsgloeilamp met een rechte gloeidraad. Via een lens tekent deze projektor op de tegenoverliggende ontvanger een streep.Deze streepjesprojektor is op de zender aangebracht en kan bediend worden door de drukknop naast de stekker.
Justage:
Het best volgt de justage bij gedempt omgevingslicht. Dit laat toe het streepje van justagehulp beter te zien op de ontvanger.Eerst de kontermoeren op de zender lossen.Dan de projektor inschakelen. De zender moet nu om zijn langsas zo gedraaid worden dat de streep van de projektor op dezender zichtbaar is.Bij vrij lichtscherm kan het lichtgordijn nu vrij zijn. Dit is merkbaar doordat de groene LED's op de ontvanger nu branden. Is dit niet het geval, dan moet het lichtgordijn nog wat om zijn dwarsas gedraaid worden.
Justage met spiegels:
De streepjesprojektor inschakelen en de zender op het midden vande spiegel richten. Daarna de spiegel zo afregelen dat de tweede spiegel of de ontvanger precies in het midden getroffen worden.
Laser voor justage:
Voor het precies justeren van de LSUW, vooral bij grote afstanden, levert Fiessler een handig toestel. De Laser moet tegen het beschermglas van de zender en ontvanger gehouden worden. Zijn zode lichtvlek is over grote afstanden zichtbaar. Deze lichtvlek moet het tegenoverliggende toestel in het midden treffen. De test moet telkens boven en ounder uitgevoerd worden. Eventueel moet de zegeling gekorrigigeerd worden.
Justagehulp LED's:
Om de justagetoestand precies te kennen bevinden zich achter de eerste en de laatste lens telkens twee kleine rode LED's.Deze doven wanneer er voldoende lichtreserve voorhanden is.
Fotocel vrij, juist afgeregeld :
grote LED groen
justage OK
kleine LED uit Fotocel vrij, te weinig reserve :
grote LED groen
Fotocel vrij, reserve niet :
grote LED groen
om langsas draaien
kleine LED rood om dwarsas draaien
kleine LED rood Bij het afregelen mogen de aluminium profielen van de behuizing niet gebogen worden. Als laatste kontrole moet een stift van diameter 3 - 4 mm diameter langzaam voor de ontvanger van boven naar onder bewogen wor¨den.Daarbij mogen op geen enkele plaats de groene LED's doven.Deze geven aan welke reserve tegen uitval door vervuiling en netspanningstoleranties nog voorhanden is.Verder moet met de teststaaf die bij het gordijn geleverd is van boven naarbeneden voorbij de zender bewogen worden. Hierbij mag de LED "vrij" niet gaan branden.De diameter van de proefstaaf moet overeenkomen met de diameter van het kleinst detekteerbare objekt zoals dit staat aangegeven op het typeplaatje van de ontvanger
Test staaf:
De afstand tussen de zender en de ontvanger na de inbouw moet met de op het typeplaatje aangegeven afstand overeen komen.Alleen dan is de resolutie of kleinst detekteerbare objekt gegarandeerd. Langsas Längsachse
AAAA AAA AAA AAAA AAA AAAA AAA AAAA AAA AAAA AAA AAAA AAA AAAA AAA AAAA AAA AAAA AAA AAAA AAAA AAA AAAA AAA g g
Querachse
Belangrijk:
Ontvanger
Empfänger
AAA AAA AAA AAA AAA AAA AAA AAA AAA AAA AAA AAA AAA Sender Zender 44
Ontvanger
Zender
kleine LED rot
kleine LED zoot
kleine kleine LEDLED rot
zoot Strichprojektor Steepjiesprojektor
große LEDLED grün green grote
grote große LEDLED rot
zoot
Taster für
Knop voor projektor Strichprojektor
FIESSLER
Inbedrijfstellen
8
E L E K T R O N I K
Fautzoeken
8.2
Foutdetektie:
De voorwaarde voor een foutdtektie is een juist afgeregeld lichtgordijn.
Fout
hoe verhelpen
Schakeluitgangen 16 -17 18 -19 of 20 - 21 trekken niet Zender defekt, zender opsturen geliijktijdig. aan. De grote zode LEDen de zode LED aan de ontvanger werken. Schakeluitgangen 16 -17 18 -19 of 20 - 21 trekken niet Verbindingskabel tussen de ontvanger en de schakelaan. De LED aan de ontvanger en de overeinkomstige unit onderzoken. In orde is. Dan is de ontvanger deLED aan het schakeltastel schakelen niet gelijktijolig fekt. Ontvanger voor herstelling oustweren
De lichtgordijnen werken maar de schakeluitgangen laten het afweten.
De uitgangen zijn intern met een zekering 3,15 A Deze zekering is moedeliijk door overbelasting doorgebrand. Het schakelge deelte moet hersteld worden.
Lichtgordijn werkte enige tijd goed maar de uitgangen Onderzweken of vonkblussing parallel op de last staat. schakelen niet altijd door Indien dit niet zo is, dan kunnen de Schakeltastel moet hersteld worden.
De aanloopvergrendeling kan niet ontgerendeld worden door het drukken van de startknop. De gele LED brandt.
Kontroleer of de startknop en of de kontakten doorlaten.
Aan het schakelgedeelte LSUW N1 of LSUW N1 DUO De zender is niet of verkeerd aangesloten Schakelof LSUW N1 Muting branden de LED ´S groen zonder schema kontroleren drukken van de Start Knop en dit na ounderbreking en vrijgane van een lichtgordijn. Het lichtgordijn is niet vrij. De LED´s schakelen niet zu- Het Venster van de fotocellen reinigen, de justage iver am. kontroleren. Kontroleren of de inbouwreikwijte klopt volgens wat op het type plaatje is aangegeven Bij het schakelen van een grote verbruiker zoals een motor onderbreekt het lichtgordijn en rode LED ´s branden kort.
De vebindingskabel van de ontvanger naar het schakelge deelte ligt waarschinlijk parallel met met de sterkstroom kabels. Het schakelgedel te moet zo kort mogelijk bij de ontvanger staan en de kabels moeten afgeschermd zijn.
Opgelet:
met de stekker naar onder gemonteerd worden. Oplosmiddelen kunnen de plexigazen afdekkingen van de zender en ontvanger beschadigen. Als optie zijn afdekkingen in silikatglas leverbaar. Indien er laspatten op de afdekglazen kunnen springen is het best een uitwisselbare PVC afdekschijfte nemen.
Let op:
Het LSUW... system is ounderbandsvrij go het zegelmatig zeinigen van de afdekschijf met een patsmiddel zonder oplosuimiddelen. een jaarlijkse kontrole volgens EN 50 100 ( ZH 1 / 281 resp. ZH 1 / 597 ) blijft eventuwel verpflicht.
45
Le
ri ve
ng
s
g pro
ra
a mm
:
AA AA AA
Fiessler Elektronik Kastellstr. 9 D-73734 Esslingen Telefon: 0711 / 91 96 97 - 0 Telefax: 0711 / 91 96 97 - 50
AA AA AA
TÜV Rheinland
TÜV Rheinland
Veiligheidslichtschermen
Zone - bewakingen
ELEKTRONIK
FIESSLER
FIESSLER ELEKTRONIK
FIESSLER ELEKTRONIK
Referentietasters
Kantensensoren
Lijnsensoren
Doorhangsensoren
Doorhangsensoren voor slang
Telsystemen
Analoge lichtschermen
Perforatiezeeksystemen
Liftentozellen
Klewdetektoren
Afstandssensoren
FIESSLER ELEKTRONIK
ELEKTRONIK
FIESSLER
ELEKTRONIK
FIESSLER
0018452
Treebeheidssensoren
Fotocellen voor alg. toepassingen
?
Doku Nr. 310 Stand 25.03.98 / GF
ELEKTRONIK
FIESSLER
A A