Pricelist
Applied Systems
Prices and technical information for Applied Systems 2015-2016
Table of contents Type
Refrigerant
Air cooled chiller Inverter R-410A Air cooled heat pump Inverter R-410A Air cooled chiller Inverter R-410A Air cooled heat pump Inverter R-410A Air cooled heat pump Inverter - split version R-410A Water cooled chiller R-407C Water cooled chiller R-407C Condenserless chiller R-407C Condensing unit heat pump Inverter R-410A Hydronic Kit Rooftop heat pump R-410A Rooftop heat pump R-407C Fan coil Low ESP duct Medium ESP duct Medium ESP duct / BLDC High ESP flexi duct Cassette 600x600 Cassette 600x600 Cassette 900x900 Cassette 900×900 Wall mounted Floor standing Flexi type Flexi concealed Floor standing / BLDC Flexi type / BLDC Flexi concealed / BLDC Air Handling Units - AHU Overview: Air cooled chiller portfolio Overview: Portfolio Water cooled and Condenserless units Large Chillers options and accessories summary Air Cooler Air Handling Unit Dry Cooler & Condenser Cooling Tower Compressor Service Measuring conditions Commercial terms and conditions
Compressor Swing Swing Scroll Scroll Srcoll Scroll Scroll Scroll Scroll Scroll Scroll
Material
Capacity
Page
EWAQ-A EWYQ-A EWAQ-BAW EWYQ-BAW SEHVX - AAW + SERHQ-AAW1 EWWP-KBW1N EWWP-KAW1M EWLP-KBW1N ERQ EKBT / EHMC UATYQ-CY1 UATYP-AY1
5-13 kW 5-13 kW 17-75 kW 17-75 kW 20-63 kW 13-65 kW 86-194 kW 12-62 kW 11-28 kW
3 4 5 5 6 7 8 9 10 11 11 11
FWE-C FWB-B FWP-A FWD-A FWF-C FWF-B FWC-B FWG- A FWT-C FWV-D FWL-D FWM-D FWZ-A FWR-A FWS-A D-AHU Modular
27-73 kW 79-110 kW
2,1 - 10 kW 2,6 - 11 kW 2,6 – 6,5 kW 3,9 - 18 kW 2,5 - 4,5 kW 1,7 - 4 kW 5 - 7,2 kW 5,9-11,75 kW 2,3 - 5,3 kW 1,5 - 8 kW 1,5 - 8 kW 1,5 - 8 kW 2,6 - 10 kW 2,6 - 10 kW 2,6 - 10 kW 1200-15000 m3/h
Screw/Recip
NOTE: All prices are list prices, excl. VAT and valid from 1. April 2015 till 31. March 2016. All prior pricelists are not valid anymore. The Daikin Commercial Terms and Conditions apply (see last page or http://www.daikin-ce.com/legal-notice.jsp). We reserve the right for printing errors and model changes. The LOT1&2 regulation requires the manufacturers to publish additional energy efficiency data for some products shown in this literature. From September 2015, these required efficiency data can be publicly viewed and downloaded from the following free access website: www.daikin.at/energylabel/Lot1_2
2
12 13 14 15 16 16 16 17 17 19 20 21 23 24 25 27 28 30 30 32 32 32 32 32 33 35
EWAQ-A
EWAQ-A Air cooled chiller inverter High ESEER thanks to inverter technology, integrated hydronics.
Unit size (1 phase) Price Cooling capacity EER ESEER Sound power level Options OP10
evaporator heater tape
Unit size (1 phase) Price Cooling capacity EER ESEER Sound power level Options OP10 SOPHP EKRP1HBA
evaporator heater tape high ESP pump (up to 90 kPa) digital I/0 PCB
Unit size (3 phase) Price Cooling capacity EER ESEER Sound power level Options OP10 SOPHP EKRP1HBA
evaporator heater tape high ESP pump (up to 90 kPa) digital I/0 PCB
Applied Systems Price list 2015-2016
dB(A)
EWAQ005ADVP 80.818,5,2 2,75 3,75 62
EWAQ006ADVP 88.482,6 2,55 3,83 62
EWAQ007ADVP 98.162,7,1 2,41 3,87 63
CZK
12.082,-
12.082,-
12.082,-
dB(A)
EWAQ009ACV3P 111.998,8,6 3,05 4,31 64
EWAQ010ACV3P 118.579,9,6 2,93 4,3 64
EWAQ011ACV3P 127.354,11,1 2,85 4,33 64
CZK CZK CZK
13.371,on request 4.144,-
13.371,on request 4.144,-
13.371,on request 4.144,-
dB(A)
EWAQ009ACW1P 116.825,9,1 2,99 4,43 64
EWAQ011ACW1P 128.465,11,1 2,85 4,44 64
EWAQ013ACW1P 136.160,13,3 2,57 4,36 66
CZK CZK CZK
13.371,on request 4.144,-
13.371,on request 4.144,-
13.371,on request 4.144,-
CZK kW
CZK kW
CZK kW
3
EWYQ-A
EWYQ-A Air cooled heat pump inverter Wide operation range - ambient temperature in heating down to -15°C.
Unit size (1 phase) Price Cooling capacity EER Heating capacity COP Sound power level Options OP10
evaporator heater tape
Unit size (1 phase) Price Cooling capacity EER ESEER Heating capacity COP Sound power level Options OP10 SOPHP EKRP1HBA
evaporator heater tape high ESP pump (up to 90 kPa) digital I/0 PCB
Unit size (3 phase) Price Cooling capacity EER ESEER Heating capacity COP Sound power level Options OP10 SOPHP EKRP1HBA
4
evaporator heater tape high ESP pump (up to 90 kPa) digital I/0 PCB
dB(A)
EWYQ005ADVP 93.336,5,2 2,75 5,65 2,87 62
EWYQ006ADVP 100.795,6 2,55 6,35 2,83 62
EWYQ007ADVP 107.670,7,1 2,41 7,75 2,74 63
CZK
12.082,-
12.082,-
12.082,-
dB(A)
EWYQ009ACV3P 128.905,8,6 3,05 4,31 9,9 3,3 64
EWYQ010ACV3P 135.692,9,6 2,93 4,3 11,4 3,29 64
EWYQ011ACV3P 143.824,11,1 2,85 4,33 12,9 3,27 64
CZK CZK CZK
13.371,on request 4.144,-
13.371,on request 4.144,-
13.371,on request 4.144,-
dB(A)
EWYQ009ACW1P 133.935,9,1 2,99 4,43 10,9 3,28 64
EWYQ011ACW1P 145.373,11,1 2,85 4,44 12,4 3,27 64
EWYQ013ACW1P 153.710,13,3 2,57 4,36 13,9 3,25 66
CZK CZK CZK
13.371,on request 4.144,-
13.371,on request 4.144,-
13.371,on request 4.144,-
CZK kW kW
CZK kW
kW
CZK kW
kW
EWAQ-BAW, EWYQ-BAW
EWAQ-BAW Air cooled chiller inverter High efficiency with leader-of-class ESEER. No buffer tank required for standard applications.
Unit size Price Cooling capacity (nominal) EWAQ - BAWN / BAWP ESEER EWAQ - BAWN / BAWP Sound power level Options OP10 OPSP OPHP OPZL
Evaporator electric heater One centrifugal pump (low lift) One centrifugal pump (high lift) Low leaving water operation down to -10 °C
dB(A)
EWAQ016BAW 184.661,17,4 / 16,6 4,33 / 4,21 78
EWAQ021BAW 217.461,21,7 / 20,7 4,08 / 4,18 78
EWAQ025BAW 245.245,25,8 / 24,7 3,85 / 4,04 78
EWAQ032BAW 282.946,32,3 / 30,9 3,39 / 3,62 80
EWAQ040BAW 374.337,43,4 / 41,5 4,19 / 4,24 81
EWAQ050BAW 416.996,51,8 / 49,7 3,96 / 4,12 81
EWAQ064BAW 481.514,64,5 / 62,3 3,64 / 3,78 83
CZK CZK CZK
15.681,17.418,25.545,-
15.681,17.418,25.545,-
15.681,17.418,25.545,-
15.681,21.242,25.545,-
18.357,21.242,31.152,-
18.357,21.242,31.152,-
18.357,21.242,31.152,-
CZK
11.603,-
11.603,-
11.603,-
11.603,-
14.150,-
14.150,-
14.150,-
CZK kW
Kit Demand PCB Remote: On/Off, Cool/heat, thermo On/Off EKRUAHT Additional remote user interface BHGP26A1 Digital pressure gauges External adaptor for: DTA104A62 Demand and Low noise control RTD-W Modbus interface EKRP1AHT
CZK
4.158,-
4.158,-
4.158,-
4.158,-
8.316,-
8.316,-
8.316,-
CZK CZK
6.177,14.961,-
6.177,14.961,-
6.177,14.961,-
6.177,14.961,-
6.177,29.922,-
6.177,29.922,-
6.177,29.922,-
CZK
12.527,-
12.527,-
12.527,-
12.527,-
25.054,-
25.054,-
25.054,-
CZK
10.538,-
10.538,-
10.538,-
10.538,-
10.538,-
10.538,-
10.538,-
EWYQ-BAW Air cooled heat pump Inverter Wide operation range - ambient temperature in heating down to -15°C.
Unit size Price Cooling capacity (nominal) EWYQ - BAWN / BAWP ESEER EWYQ - BAWN / BAWP Heating capacity (nominal) EWYQ - BAWN / BAWP COP EWYQ - BAWN / BAWP Sound power level Options OP10 OPSP OPHP OPZL
Evaporator electric heater One centrifugal pump (low lift) One centrifugal pump (high lift) Low leaving water operation down to -10 °C
CZK
EWYQ016BAW 223.420,-
EWYQ021BAW 263.144,-
EWYQ025BAW 296.754,-
EWYQ032BAW 342.386,-
EWYQ040BAW 452.866,-
EWYQ050BAW 504.524,-
EWYQ064BAW 582.625,-
kW
17,4 / 16,6
21,7 / 20,7
25,8 / 24,7
32,3 / 30,9
43,4 / 41,5
51,8 / 49,7
64,5 / 62,3
4,33 / 4,21
4,08 / 4,18
3,85 / 4,04
3,39 / 3,62
4,19 / 4,24
3,96 / 4,12
3,64 / 3,78
kW
16,2 / 17,0
20,3 / 21,3
24,6 / 25,7
30,7 / 32,1
41,6 / 42,5
49,0 / 51,1
61,5 / 63,7
dB(A)
2,93 / 2,97 78
2,86 / 2,86 78
2,76 / 2,75 80
2,90 / 2,89 80
2,90 / 2,89 81
2,78 / 2,76 83
2,97 / 2,94 83
CZK CZK CZK
15.681,17.418,25.545,-
15.681,17.418,25.545,-
15.681,17.418,25.545,-
15.681,21.242,25.545,-
18.357,21.242,31.152,-
18.357,21.242,31.152,-
18.357,21.242,31.152,-
CZK
11.603,-
11.603,-
11.603,-
11.603,-
14.150,-
14.150,-
14.150,-
CZK
4.158,-
4.158,-
4.158,-
4.158,-
8.316,-
8.316,-
8.316,-
CZK CZK
6.177,14.961,-
6.177,14.961,-
6.177,14.961,-
6.177,14.961,-
6.177,29.922,-
6.177,29.922,-
6.177,29.922,-
CZK
12.527,-
12.527,-
12.527,-
12.527,-
25.054,-
25.054,-
25.054,-
CZK
10.538,-
10.538,-
10.538,-
10.538,-
10.538,-
10.538,-
10.538,-
Kit Demand PCB Remote: On/Off, Cool/heat, thermo On/Off EKRUAHT Additional remote user interface BHGP26A1 Digital pressure gauges External adaptor for: DTA104A62 Demand and Low noise control RTD-W Modbus interface EKRP1AHT
Applied Systems Price list 2015-2016
5
SEHVX-AAW, SERHQ-AAW1
SEHVX - AAW Air cooled heat pump inverter - split version
Unit size Indoor unit Outdoor Units Refnet type Indoor unit Price per each Outdoor unit Price per each Refnet Price per each Unit Price per each (indoor + outdoor(s) + refnet) Cooling Capacity (nominal) Cooling Capacity (maximum) EER Heating Capacity (nominal) Heating Capacity (maximum) COP Sound power level (outdoor unit / each) Indoor unit connection (liquid / gas) Standard Options Standard Hydraulic package One centrifugal pump
CZK CZK CZK kW dB(A) kW kW dB(A)
64 1× SEHVX64AAW 2× SERHQ032AAW1 KHRQ22M75T8 149.893,259.433,6.769,675.528,62,3 (1) 74,3 (1) 2,27 (1) 63,7 (2)(3) 75,7 (2)(3) 3,77 (2) / 2,94 (3) 80 dB(A) 15,9 / 31,8
SEHVX32AAW
SEHVX40AAW
SEHVX64AAW
including as standard
including as standard
including as standard
SEHVX20AAW
SEHVX32AAW
SEHVX40AAW
SEHVX64AAW
CZK
4.158,-
4.158,-
8.316,-
8.316,-
CZK
12.527,-
12.527,-
25.054,-
25.054,-
CZK CZK
10.538,28.562,-
10.538,28.562,-
10.538,28.562,-
10.538,28.562,-
(1) Cooling: Ta 35°C - LWE 7°C (DT=5°C), data according EN 14511: 2011 (2) Heating Ta DB/WB 7/6°C - LWC35°C (DT = 5°C), data according EN 14511: 2011
6
40 1× SEHVX40AAW 2× SERHQ020AAW1 KHRQ22M64T8 147.211,184.151,5.492,521.005,41,5 (1) 49,5 (1) 2,69 (1) 42,5 (2)(3) 50,5 (2)(3) 3,54 (2) / 2,89 (3) 78 dB(A) 15,9 / 31,8
SEHVX20AAW
Notes:
(3) Heating Ta DB/WB 7/6°C - LWC45°C
32 1× SEHVX32AAW 1× SERHQ032AAW1 140.384,259.433,399.817,30,9 (1) 36,9 (1) 2,29 (1) 32,2 (2)(3) 38,1 (2)(3) 3,68 (2) / 2,89 (3) 80 dB(A) 12,7 / 25,4
including as standard
CZK
Kit Demand PCB Remote: EKRP1AHT On/Off, Cool/heat, thermo On/Off External adaptor for: DTA104A62 Demand and Low noise control RTD-W Modbus interface EKCC*-W Cascade Control
20 1× SEHVX20AAW 1× SERHQ020AAW1 125.633,184.151,309.784,20,7 (1) 24,7 (1) 2,73 (1) 21,3 (2)(3) 25,3 (2)(3) 3,48 (2) / 2,86 (3) 78 dB(A) 12,7 / 25,4
EWWP-KBW1N
EWWP-KBW1N Water cooled chiller
Unit size Price Cooling capacity EER Heat rejection capacity Sound power level
kW dB(A)
EWWP014KBW1N 105.352,12,9 3,44 16,7 64
EWWP022KBW1N 145.694,21,4 3,49 27,5 64
EWWP028KBW1N 167.708,27,8 3,54 35,6 64
EWWP035KBW1N 187.758,32,3 3,54 41,5 71
Options OPZH OPZL
glycol application to -5 °C LWE glycol application to -10 °C LWE
CZK CZK
7.314,7.314,-
7.314,7.314,-
7.314,7.314,-
7.314,7.314,-
Kit EKLS1 EKLS2 EKAC10C EKRUMCA EHMC10A10 EHMC10A80 EHMC15A10 EHMC15A80
low noise kit 5 HP low noise kit 8/10/12 HP BMS address card remote user interface hydraulic module hydraulic module – pump size up hydraulic module hydraulic module – pump size up
CZK CZK CZK CZK CZK CZK CZK CZK
6.356,– 4.445,6.513,69.527,71.415,– –
– 6.356,4.445,6.513,69.527,71.415,– –
– 6.356,4.445,6.513,69.527,71.415,73.933,75.883,-
– 6.356,4.445,6.513,– – 73.933,75.883,-
Unit size Price Cooling capacity EER Heat rejection capacity Sound power level
CZK kW
kW dB(A)
EWWP045KBW1N 234.425,42,8 3,51 55,0 67
EWWP055KBW1N 277.970,55,7 3,48 71,7 67
EWWP065KBW1N 308.205,64,7 3,55 83 74
CZK kW
Options OPZH OPZL
glycol application to -5 °C LWE glycol application to -10 °C LWE
CZK CZK
7.314,7.314,-
7.314,7.314,-
7.314,7.314,-
Kit EKLS2 EKAC10C EKRUMCA EHMC15A10 EHMC15A80 EHMC30A10 EHMC30A80
low noise kit 8/10/12 HP (2 pcs.) BMS address card remote user interface hydraulic module hydraulic module – pump size up hydraulic module hydraulic module – pump size up
CZK CZK CZK CZK CZK CZK CZK
12.712,4.445,6.513,73.933,75.883,78.729,81.249,-
12.712,4.445,6.513,– – 78.729,81.249,-
12.712,4.445,6.513,– – 78.729,81.249,-
Note: E23KAC10C is needed for direct BMS connection via Modbus EKAC10C is needed to install EKRUMCA
Applied Systems Price list 2015-2016
7
EWWP-KAW1M
EWWP-KAW1M Water cooled chiller
Capacity index
Control box Price Cooling capacity Sound power level
CZK kW dB(A)
090 EWWP045KAW1M EWWP045KAW1M ECB2MUW 432.090,85,7 71
Options OPZH OPZL
CZK CZK
14.628,14.628,-
14.628,14.628,-
14.628,14.628,-
14.628,14.628,-
130
155 EWWP045KAW1M EWWP055KAW1M EWWP055KAW1M ECB3MUW 703.829,154 73
165 EWWP055KAW1M EWWP055KAW1M EWWP055KAW1M ECB3MUW 751.597,167 73
21.942,21.942,-
Basic model
glycol application to -5°C LWE glycol application to -10°C LWE
Capacity index
100 EWWP045KAW1M EWWP055KAW1M ECB2MUW 479.858,98,6 71
110 EWWP055KAW1M EWWP055KAW1M ECB2MUW 527.626,112 71
120 EWWP055KAW1M EWWP065KAW1M ECB2MUW 558.789,121 75
Control box Price Cooling capacity Sound power level
CZK kW dB(A)
ECB2MUW 589.952,130 77
145 EWWP045KAW1M EWWP045KAW1M EWWP055KAW1M ECB3MUW 656.061,141 73
Options OPZH OPZL
CZK CZK
14.628,14.628,-
21.942,21.942,-
21.942,21.942,-
Control box Price Cooling capacity Sound power level
CZK kW dB(A)
175 EWWP055KAW1M EWWP055KAW1M EWWP065KAW1M ECB3MUW 782.760,176 76
185 EWWP055KAW1M EWWP065KAW1M EWWP065KAW1M ECB3MUW 813.923,185 78
195 EWWP065KAW1M EWWP065KAW1M EWWP065KAW1M ECB3MUW 845.086,194 79
Options OPZH OPZL
CZK CZK
21.942,21.942,-
21.942,21.942,-
21.942,21.942,-
EWWP065KAW1M EWWP065KAW1M
Basic model
glycol application to -5°C LWE glycol application to -10°C LWE
Capacity index Basic model
8
glycol application to -5°C LWE glycol application to -10°C LWE
EWLP-KBW1N
EWLP-KBW1N Condenserless chiller
Unit size Price Cooling capacity EER Sound power level
dB(A)
EWLP012KBW1N 98.322,12,1 2,88 64
EWLP020KBW1N 125.103,20 3,03 64
EWLP026KBW1N 144.004,26,8 3,15 64
EWLP030KBW1N 161.182,31,2 3,09 71
CZK kW
Options OPZH OPZL
glycol application to -5°C LWE glycol application to -10°C LWE
CZK CZK
7.314,7.314,-
7.314,7.314,-
7.314,7.314,-
7.314,7.314,-
Kit EKLS1 EKLS2 EKAC10C EKRUMCA EHMC10A10 EHMC10A80 EHMC15A10 EHMC15A80
low noise kit 5 HP low noise kit 8/10/12 HP BMS address card remote user interface hydraulic module hydraulic module – pump size up hydraulic module hydraulic module – pump size up
CZK CZK CZK CZK CZK CZK CZK CZK
6.356,– 4.445,6.513,69.527,71.415,– –
– 6.356,4.445,6.513,69.527,71.415,– –
– 6.356,4.445,6.513,69.527,71.415,73.933,75.883,-
– 6.356,4.445,6.513,– – 73.933,75.883,-
Unit size Price Cooling capacity EER Sound power level
dB(A)
EWLP040KBW1N 201.261,40 2,99 67
EWLP055KBW1N 238.632,53,7 3,02 67
EWLP065KBW1N 264.613,62,4 3,07 74
CZK kW
Options OPZH OPZL
glycol application to -5°C LWE glycol application to -10°C LWE
CZK CZK
7.314,7.314,-
7.314,7.314,-
7.314,7.314,-
Kit EKLS2 EKAC10C EKRUMCA EHMC15A10 EHMC15A80 EHMC30A10 EHMC30A80
low noise kit 8/10/12 HP (2 pcs.) BMS address card remote user interface hydraulic module hydraulic module – pump size up hydraulic module hydraulic module – pump size up
CZK CZK CZK CZK CZK CZK CZK
12.712,4.445,6.513,73.933,75.883,78.729,81.249,-
12.712,4.445,6.513,– – 78.729,81.249,-
12.712,4.445,6.513,– – 78.729,81.249,-
Note: EKAC10C is needed for direct BMS connection via Modbus EKAC10C is needed to install EKRUMCA
Applied Systems Price list 2015-2016
9
Outdoor units
ERQ Inverter heat pump condensing units ERQ-A High efficiency inverter heat pump outdoor units for connection to DX heat exchangers in Air Handling Units (AHU) or to CYQ Air Curtains Type for 1~ 230V power supply Capacity index Nominal cooling capacity Nominal heating capacity Price Type for 3N~ 400V power supply Capacity index Nominal cooling capacity Nominal heating capacity Price
kW kW CZK
ERQ100AV1 100 11,2 12,5 98.145,-
ERQ125AV1 125 14,0 16,0 122.643,-
ERQ140AV1 140 15,5 18,0 137.396,-
kW kW CZK
ERQ125AW1 125 14,0 16,0 106.868,-
ERQ200AW1 200 22,4 25,0 170.431,-
ERQ250AW1 250 28,0 31,5 198.733,-
Notes: - When using for connection to CYQ Air Curtains, select an ERQ outdoor unit with an equal or higher capacity index than the capacity index of the Air Curtain - Specified capacity values are for evaporation temperature = 6 °C (cooling) / condensing temperature = 46 °C (heating), evaporator superheat = 5K,condenser sub-cool = 3K, on-coil temperature = 27 °CDB / 19 °CWB (cooling) / = 20 °CDB (heating) Control box Control type
EKEQDCB Daikin control
Control options
Price
CZK
EKEQFCBA Free (External) control • (X-Control): 0~10V direct capacity control (5V = maintain Room temperature control [via Remote Controller capacity, >5V colder air wanted, <5V warmer air wanted) (accessory) or via External room temperature sensor • (Y-Control): Fixed evaporation / condensation temperature control (accessory)] Return air temperature control (via a supplied thermistor) • (W-Control): 0~10V linear capacity control (0V = 0% capacity, 10V = 100% capacity 20.096,22.388,-
Notes: - A control box is a necessary component of the system for AHU applications; it is not necessary for connection to CYQ Air Curtains - A wired remote controller (Standard or Basic) is required for the EKEQDCB control box; for the EKEQFCBA box, it is optional (required for commissioning and servicing only) - Switching between cooling/heating operation with the EKEQFCBA box must be done from the external control system, or via the optional KRC19-26 Cool/Heat selector Allowed heat exchanger capacity [kW]
Expansion valve kit
Minimum
Combinable units
Maximum
ERQ100-
ERQ125-
ERQ140-
• • • •
• • • • •
• • • •
EKEXV63
6,3
7,8
EKEXV80
7,9
9,9
EKEXV100
10,0
12,3
EKEXV125
12,4
15,4
EKEXV140
15,5
17,6
EKEXV200
17,7
24,6
EKEXV250
24,7
30,8
ERQ200-
ERQ250-
Price CZK 4.720,5.016,-
• • • • •
5.195,-
• • • •
5.492,5.669,6.174,6.560,-
Notes: - An expansion valve kit is a necessary component of the system for AHU applications; it is not necessary for connection to CYQ Air Curtains, - The expansion valve kit needs to be selected based on the nominal design of the AHU heat exchanger, - The AHU heat exchanger needs to be designed for 40bar pressures, with an internal (refrigerant) volume between 0,3 and 8,3 l (not counting headers and distributors) - Specified capacity values are for evaporation temperature = 6 °C (cooling) / condensing temperature = 46 °C (heating), evaporator superheat = 5K, condenser sub-cool = 3K, on-coil temperature = 27 °CDB / 19 °CWB (cooling) / = 20 °CDB (heating)
Unit-specific Accessories BRC1D52
Basic wired remote controller with weekly timer
BRC1E52B
Standard wired remote controller with full-text interface and back-light
KRP4A51
Adaptor for external monitoring/control
RTD-20
Adaptor for external monitoring/control with 0-10VDC linear capacity control
KRCS01-1
External room temperature sensor
KRC19-26
Mechanical cool/heat selector
KJB111A
Fixing box for cool/heat selector
EKEQDCB
EKEQFCBA
Price CZK
• • • • • • •
• •
3.176,4.177,5.106,12.063,2.432,-
• •
1.662,771,-
Notes: - A wired remote controller (Standard or Basic) is required for the EKEQDCB control box; for the EKEQFCBA box, it is optional (required for commissioning and servicing only) - Switching between cooling/heating operation with the EKEQFCBA box must be done from the external control system, or via the optional KRC19-26 Cool/Heat selector
10
HYDRONIC KIT, ROOFTOP
HYDRONIC KIT
Buffer tanks EKBT EKBT500N EKBTC10N EKBT500C EKBTC10C
200 l buffer tank with casing 500 l buffer tank 1000 l buffer tank 500 l buffer tank with casing 1000 l buffer tank with casing
CZK CZK CZK CZK CZK
44.433,55.856,77.442,121.364,161.809,-
Hydraulic modules EHMC10A10 hydraulic module EHMC10A80 hydraulic module – high ESP EHMC15A10 hydraulic module EHMC15A80 hydraulic module – high ESP EHMC30A10 hydraulic module EHMC30A80 hydraulic module – high ESP
CZK CZK CZK CZK CZK CZK
69.527,71.415,73.933,75.883,78.729,81.249,-
UATYQ-CY1 Rooftop heat pump Convertible return and supply air: fan can be mounted in two directions
Unit size Price Cooling capacity EER Heating capacity COP Sound power level Options DEC101A51 DEC102A51 DTA103A51 ECONO250AY1 ECONO350AY1 ECONO450AY1 ECONO550AY1 ECONO600AY1 ECONO700AY1
dB(A)
UATYQ250CY1 180.411,27,34 3,36 24,91 3,40 82
UATYQ350CY1 261.849,35,58 3,30 34,79 3,21 83
UATYQ450CY1 338.587,44,72 3,43 41,79 3,25 83
UATYQ550CY1 402.868,55,69 3,33 53,93 3,47 87
UATYQ600CY1 417.804,66,82 3,4 61,69 3,32 90
UATYQ700CY1 419.328,72,6 3,36 69,61 3,25 90
CZK CZK CZK CZK CZK CZK CZK CZK CZK
27.578,30.426,17.365,42.779,– – – – –
27.578,30.426,17.365,– 44.951,– – – –
27.578,30.426,17.365,– – 47.199,– – –
27.578,30.426,17.365,– – – 49.522,– –
27.578,30.426,17.365,– – – – 51.994,–
27.578,30.426,17.365,– – – – – 54.616,-
CZK kW kW
UATYP-AY1 Rooftop heat pump Belt driven fan enables air volume and static pressure to be adjusted as required.
Unit size Price Cooling capacity EER Heating capacity COP Sound pressure level at 1m
Applied Systems Price list 2015-2016
CZK kW kW dB(A)
UATYP850AY1B 494.859,78,60 2,18 87,80 2,73 74
UATYPC10AY1 614.668,101,10 2,34 102,30 2,45 80
UATYPC12AY1 704.682,109,60 2,27 126,30 2,7 80
11
FWE-C, Low ESP duct fan coil
FWE-C Fan coil, ACCESSORIES 4-speed fan motor, available static pressure up to 50Pa
Low ESP duct unit FWE-C FWE**CT-, 2 pipe unit, standard, without valves FWE**CTV, 2 pipe unit, with 3-ways 230V on/off valve, factory mounted FWE**CTT, 2 pipe unit, with 2-ways 230V on/off valve, factory mounted Cooling capacity (Total at Super High Speed) Heating capacity (2-pipe at Super High Speed) FWE**CF-, 4 pipe unit, standard, without valves FWE**CFV, 4 pipe unit, with 3-ways 230V on/off valves, factory mounted FWE**CFT, 4 pipe unit, with 2-ways 230V on/off valves, factory mounted Cooling capacity (Total at Super High Speed) Heating capacity (4-pipe at Super High Speed) (1)
02
03
04
06
07
08
10
CZK
6.471,-
7.337,-
7.938,-
10.340,-
11.139,-
13.075,-
15.742,-
CZK
11.085,-
11.947,-
12.610,-
15.001,-
15.797,-
17.655,-
20.310,-
CZK
9.093,-
9.956,-
10.553,-
13.008,-
13.739,-
15.664,-
18.319,-
kW kW
2,17 2,79
3,22 4,28
4,34 5,61
6,06 7,66
6,83 9,26
7,84 10,50
9,96 13,00
CZK
7.537,-
8.538,-
9.272,-
11.940,-
12.741,-
14.943,-
17.610,-
CZK
15.730,-
16.726,-
17.457,-
20.111,-
20.907,-
23.098,-
25.753,-
CZK
12.743,-
13.739,-
14.469,-
17.124,-
17.921,-
20.111,-
22.766,-
kW kW
2,10 2,30
3,16 3,53
3,98 4,56
6,05 6,17
6,76 7,60
7,79 8,52
9,91 10,40
02
03
04
06 EK2MV3B10C5 2.631,EK2MV2B10C5 2.209,EK4MV3B10C5 4.990,EK4MV2B10C5 4.330,-
07
08
10
02
03
04
06 FWEC1A 2.638,FWEC2A 4.137,FWEC3A 5.636,FWFCKA 451,FWTSKA 239,FWHSKA 629,EPIMSB6 3.599,-
07
08
10
Accessories for FWE-C 2 pipes 3-ways on/off 230V valve kit 2 pipes 2-ways on/off 230V valve kit 4 pipes 3-ways on/off 230V valve kit 4 pipes 2-ways on/off 230V valve kit
CZK CZK CZK CZK
Controller for FWE-C Controller electronic Standard version, (see note 2)
CZK
Controller electronic Advanced version
CZK
Controller electronic Advanced Plus version
CZK
Wall mounting kit (spacing collar) for FWEC*A
CZK
Temperature sensor kit for FWEC*A
CZK
Relative humidity sensor kit for FWEC2A and FWEC3A
CZK
Master / Slave interface
CZK
Notes: (1) Rating conditions: air 20°C DB, entering water 50°C, leaving water 40°C (2) FWEC1A can operate with 3 speeds of fan only, if it also manages 2 valves on 4-pipes unit
12
FWB-B, Medium ESP duct fan coil
FWB-B Fan coil, Accessories Low sound power levels and electrical absorption thanks to plastic impeller and improved electric motor.
Medium ESP duct unit FWB-B FWB**BTN, 2 pipe unit, standard, without valves FWB**BTV, 2 pipe unit, with 3-ways 230V on/off valve, factory mounted FWB**BTNE, 2 pipe unit, without valves and electric heater, factory mounted FWB**BTVE, 2 pipe unit, with 3-ways 230V on/off valve and electric heater, factory mounted Cooling capacity (Total at High Speed) Heating capacity (2-pipe at High Speed) Heating capacity (4-pipe at High Speed)
Accessories for FWB-B Additional single row heat exchanger 3-way valve add. h/e 2-way valve add. h/e Fan stop thermostat
02
03
04
05
06
07
08
09
10
CZK
12.724,-
13.602,-
14.421,-
17.404,-
18.018,-
19.745,-
23.809,-
25.184,-
26.793,-
CZK
16.877,-
17.697,-
18.516,-
21.500,-
22.112,-
23.809,-
28.169,-
29.455,-
31.152,-
CZK
20.533,-
21.441,-
22.259,-
26.121,-
26.734,-
28.373,-
33.052,-
34.428,-
36.065,-
CZK
24.628,-
25.506,-
26.325,-
30.215,-
30.830,-
32.439,-
37.410,-
38.698,-
40.424,-
kW kW kW
2,61 5,47 3,14
3,14 6,01 3,14
3,49 6,47 3,14
5,08 10,31 5,99
5,45 11,39 5,99
6,47 12,28 5,99
7,57 15,05 12,80
8,67 16,85 12,80
10,34 18,78 12,80
02
03 EAH04A6 4.947,-
04
05
06 EAH07A6 5.547,-
07
08
09 EAH10A6 7.314,E2MV310A6 5.277,E2MV210A6 2.879,-
10
07
08
09
10
CZK
CZK
CZK
Controller electronic Advanced version
CZK
Controller electronic Advanced Plus version
CZK
Wall mounting kit (spacing collar) for FWEC*A
CZK
Temperature sensor kit for FWEC*A
CZK
Relative humidity sensor kit for FWEC2A and FWEC3A
CZK
Applied Systems Price list 2015-2016
YFSTA6 510,-
CZK
Controller for FWB-B Controller electronic Standard version
Master / Slave interface
E2MV307A6 5.277,E2MV207A6 2.727,-
CZK
02
CZK
03
04
05
06 FWEC1A 2.638,FWEC2A 4.137,FWEC3A 5.636,FWFCKA 451,FWTSKA 239,FWHSKA 629,EPIMSB6 3.599,-
13
FWP - A, Medium ESP duct fan coil with DC fan motor
FWP-A Fan coil, Accessories Low sound level and up to 50% energy saving thanks to the BLDC motor technology
Medium ESP duct unit with DC fan motor FWP-A FWP**ATN, 2 pipe unit, standard, without valves FWP**ATV, 2 pipe unit, with 3-ways 230V on/off valve, factory mounted FWP**ATNE, 2 pipe unit, without valves and electric heater, factory mounted FWP**ATVE, 2 pipe unit, with 3-ways 230V on/off valve and electric heater, factory mounted Cooling capacity (Total at High Speed) Heating capacity (2-pipe at High Speed) Heating capacity (4-pipe at High Speed)
Accessories for FWP-A Additional single row heat exchanger 3-way valve add. h/e 2-way valve add. h/e
02
03
04
05
06
07
CZK
17.722,-
18.451,-
19.182,-
22.501,-
22.766,-
24.292,-
CZK
21.638,-
22.434,-
23.164,-
26.483,-
26.748,-
28.275,-
CZK
25.288,-
26.085,-
26.814,-
30.930,-
31.195,-
32.722,-
CZK
29.270,-
30.067,-
30.731,-
34.912,-
35.177,-
36.705,-
kW kW kW
2,61 5,47 3,14
3,14 6,01 3,14
3,49 6,47 3,14
5,08 10,31 5,99
5,45 11,39 5,99
6,47 12,28 5,99
02
03 EAH04A6 4.947,-
04
05
06 EAH07A6 5.547,-
07
05
06
07
CZK
CZK
Controller for FWP-A Controller electronic Advanced Plus version
CZK
Wall mounting kit (spacing collar) for FWEC*A
CZK
Temperature sensor kit for FWEC*A
CZK
Relative humidity sensor kit for FWEC2A and FWEC3A
CZK
14
E2MV307A6 5.277,E2MV207A6 2.727,-
CZK
02
03
04 FWEC3A 5.636,FWFCKA 451,FWTSKA 239,FWHSKA 629,-
FWD - A, High ESP flexi type fan coil
FWD - A Fan coil, ACCESSORIES Straight duct connector is mounted to discharge side
2-pipe unit FWD**AT Price Cooling capacity (Total at High Speed) Heating capacity (2-pipe at High Speed)
CZK kW kW
04 15.298,3,90 4,05
06 20.212,6,20 7,71
08 23.605,7,80 9,43
10 26.267,8,82 10,79
12 32.643,11,90 14,45
16 41.916,16,40 19,81
18 46.070,18,30 21,92
4-pipe unit FWD**AF Price Cooling capacity (Total at High Speed) Heating capacity (4-pipe at High Speed)
CZK kW kW
04 17.959,3,90 4,49
06 23.458,6,20 6,62
08 27.407,7,80 9,21
10 30.420,8,82 9,21
12 38.289,11,90 15,86
16 48.497,16,40 21,15
18 53.206,18,30 21,15
12 EDEHS12A6 15.064,EDEHB12A6 15.064,ED2MV12A6 5.324,2 x ED2MV12A6 10.648,-
16
Accessories for FWD Electric heater low capacity
CZK
Electric heater high capacity
CZK
2-pipe 3-way valve 4-pipe 3-way valve Vertical drainpan Horizontal drainpan Fan stop thermostat Fresh air intake
CZK CZK CZK CZK CZK CZK
Controller for FWD Controller electronic Standard version Controller electronic Advanced version Controller electronic Advanced Plus version
04 06 08 10 EDEH04A6 EDEHS06A6 EDEHS10A6 7.839,14.742,14.742,EDEH04A6 EDEHB06A6 EDEHB10A6 7.839,14.742,14.742,ED2MV04A6 ED2MV10A6 5.558,5.850,ED4MV04A6 ED4MV10A6 10.647,11.320,EDDPV10A6 322,EDDPH10A6 468,YFSTA6 510,EDMFA04A6 EDMFA06A6 EDMFA10A6 26.707,27.290,27.817,04
06
08
12
FWEC1A CZK
2.638,FWEC2A
CZK
4.137,FWEC3A
CZK
Wall mounting kit (spacing collar) for FWEC*A
CZK
Temperature sensor kit for FWEC*A
CZK
Relative humidity sensor kit for FWEC2A and FWEC3A
CZK
5.636,-
CZK CZK
EDMFA18A6 29.893,16 FWEC1A EPIB6 requested 2.638,FWEC2A EPIB6 requested 4.137,FWEC3A EPIB6 requested 5.636,-
18
FWFCKA 451,FWTSKA 239,FWHSKA 629,EPIMSB6 3.599,-
Master / Slave interface Power interface
10
EDMFA12A6 29.484,-
18 EDEHS18A6 16.935,EDEHB18A6 16.935,ED2MV18A6 6.143,2 x ED2MV18A6 12.286,EDDPV18A6 498,EDDPH18A6 643,-
–
EPIB6 4.287,-
Note: For FWD size 12, 16 or 18 EPIB6 needs to be used for each FWD unit to connect to FWEC*A controllers. If FWD size 12, 16 or 18 are used in Master/Slave application by using EPIMSB6 still EPIB6 needs to be used for each FWD to connect to EPIMSB6.
Applied Systems Price list 2015-2016
15
FWF-C, FWF-B, FWC-B, Cassette fan coils
FWF-C Fan coil Infrared remote control as standard with decoration panel kit.
FWF-C cassette unit FWF**CT, 2 pipe unit, incl. condensate pump, without valves Cooling capacity (Total at High Speed) Heating capacity (2-pipe at High Speed)
02
03
04
CZK
13.953,-
15.708,-
15.913,-
kW kW
2,49 3,52
4,10 4,69
4,54 5,28
Note: Decoration panel is mandatory, it is included with other accessories in table on page 17.
FWF-B Fan coil Possibility to shut 1 or 2 flaps for easy installations in corners.
FWF-B cassette unit FWF**BT, 2 pipe unit, incl. condensate pump, without valves Cooling capacity (Total at Super High Speed) Heating capacity (2-pipe at Super High Speed) FWF**BF, 4 pipe unit, incl. condensate pump, without valves Cooling capacity (Total at Super High Speed) Heating capacity (4-pipe at Super High Speed)
02
03
04
05
CZK
19.338,-
21.166,-
22.756,-
23.986,-
kW kW
2,00 2,90
3,20 4,00
4,20 5,40
5,20 6,70
CZK
21.527,-
23.386,-
24.554,-
25.784,-
kW kW
2,00 3,80
2,70 3,80
3,50 4,90
4,50 6,10
06
07
08
09
CZK
27.962,-
28.812,-
30.186,-
31.298,-
kW kW
5,80 8,00
6,80 8,90
7,70 10,60
8,70 12,10
CZK
29.923,-
30.860,-
31.795,-
32.877,-
kW kW
5,80 7,50
6,60 8,40
7,60 9,70
8,70 11,00
Note: Decoration panel is mandatory, it is included with other accessories in table on page 18.
FWC-B Fan coil 360° air discharge ensures uniform air flow and temperature distribution.
FWC-B cassette unit FWC**BT, 2 pipe unit, incl. condensate pump, without valves Cooling capacity (Total at High Speed) Heating capacity (2-pipe at High Speed) FWC**BF, 4 pipe unit, incl. condensate pump, without valves Cooling capacity (Total at High Speed) Heating capacity (4-pipe at High Speed)
Note: Decoration panel is mandatory, it is included with other accessories in table on page 18.
16
FWG-A cassette fan coil, FWT-C Wall mounted fan coil, Accessories for FWT-C, FWF-C, FWG-A,
FWG - A Cassette fan coils with DC fan motor Low sound level and up to 70% energy saving thanks to the BLDC motor technology infrared remote control is standard with decoration panel kit. FWG - A cassette unit FWG**AT 2 pipe unit , incl. condensate pump, without valves Cooling Capacity (Total at High Speed) Heating Capacity (2 pipe at High Speed) FWG**AF 4 pipe unit , incl. condensate pump, without valves Cooling Capacity (Total at High Speed) Heating Capacity (4 pipe at High Speed)
05
08
11
CZK
27.893,-
30.663,-
32.397,-
kW kW
5.90 7.10
8.80 11.20
11.75 13.70
CZK
30.523,-
33.405,-
35.027,-
kW kW
4.40 7.65
7.20 11.20
9.00 15.65
Note: Decoration panel is mandatory, it is include with other accessories in below table Accessories for FWG - A Decoration Panel / FWG AT 2 pipes include GS02 wireless controller
CZK
Decoration Panel / FWG AF 4 pipes include GS02 wireless controller
CZK
DCP900BTA 4.476,DCP900BFA 4.476,BRC51A61 2.742,Type GS02 Decoration panel already included VKFWGA012T3V 3.301,VKFWGA014T3V 6.659,-
Wired controller CZK Wireless controller Decoration panel already include
CZK
Valve kit 3-ways ON/OFF 230 V 2 pipe version
CZK
Valve kit 3-ways ON/OFF 230 V 4 pipe version
CZK
VKFWGA022T3V 3.581,VKFWGA024T3V 6.938,-
FWT-C Fan coil Flexibility via interchangeable water connection side.
FWT-C wall mounted unit FWT**CT, 2 pipe unit, without valves Cooling capacity (Total at High Speed) Heating capacity (2-pipe at High Speed)
02
03
04
05
06
CZK
8.775,-
9.799,-
9.945,-
13.544,-
13.806,-
kW kW
2,34 3,02
2,78 3,75
3,22 4,10
4,54 6,01
5,28 6,74
FWT-C + FWF-C Accessories Type Decoration panel 2-pipe Incl. wireless controller
CZK
FWF-CT DCP600TC 4.822,-
CZK Simplified wired remote control CZK Simplified wired remote control CZK Wireless control CZK CZK
Applied Systems Price list 2015-2016
– MERCA 3.802,SRC-COA 1.930,SRC-HPA 1.930,WRC-HPC 761,-
Standard wired remote control
2-pipe 3-way valve
FWT-CT
MCKCW2T3VN 3.511,-
–
17
Accessories for FWC-B, FWF-B
FWC-B, FWF-B Accessories Options Decoration Panel Round Flow Standard Decoration Panel 4-way blow Sealing member of air discharge outlet Long-life filter Panel spacer Fresh air intake kit
CZK CZK CZK CZK CZK CZK
FWC-B BYCQ140C 7.541,-
FWF-B -
CE.KDDQ55C140 15.733,-
BYFQ60B3 4.955,KDBH44BA60 4.106,KAFQ441BA60 on request KDBQ44B60 13.893,KDDQ44XA60 4.661,-
BRC7F532F (11) 5.076,BRC7F533F (11) 3.593,-
BRC7E530 (11) 5.100,BRC7E531 (11) 8.401,-
KDBHQ55C140 3.088,KAFP551K160 2.939,-
Control Systems Remote control Infrared H/P Remote control Infrared C/O Remote Control Wired Central remote control Electrical box with earth terminal (3 blocks) Unified on/off control Electrical box with earth terminal (2 blocks) Shedule timer Wiring adapter for electrical appendices 1 Wiring adapter for electrical appendices 2 Installation box for adapter PCB Remote Sensor Intelligent touch controller Electrical installation box Optional PCB for MOD-bus connection 2-way valve - On/Off 3-way valve - On/Off Valve control PCB Remote “On/Off ” and “forced off ” kit
CZK CZK
BRC315D (1) 3.267,DCS302C51 (2) 49.425,KJB311A 2.286,DCS301B51 (5) 20.809,KJB212A 2.197,DST301B51 (5)(8) 26.003,KRP2A52 (4)(8) 10.092,KRP4A53 (4)(8) 5.106,-
CZK CZK CZK CZK CZK CZK CZK CZK CZK CZK
KRP1H98 (9) 1.485,KRCS01-4 2.433,DCS601C51 (3)(7) 54.882,KJB411A 3.948,EKFCMBCB (4)(8) 2.998,EKMV2C09B (4)(6)(10) 2.488,EKMV3C09B (4)(6)(10) 2.819,EKRP1C11 2.288,-
CZK CZK CZK CZK CZK CZK CZK
EKRORO (12) 743,-
-
Notes: 1. Optional, electrical installation box with earth terminal KJB212A is required, if controller wires need to be installed in the wall. 2. Requires electrical installation box with earth terminal KJB311A. 3. Requires electrical installation box KJB411A. 4. Requires installation box KRP1H98 for FWC-B and KRP1BA101 for FWF-B. 5. Requires electrical installation box with earth terminal KJB212A, if built in the wall. 6. Requires valve control PCB EKRP1C11. 7. I-touch: • Not allowed to use the i-touch for an installation with both fan coils and VRV units. • Can not be used in combination with fan coil units, that use MOD bus communication. • No Airnet or telephone connection possible. 8. Only 1 of these 4 options can be installed on 1 indoor unit. 9. FWC -B: Max. 1 KRP1H98 box can be mounted on the unit. Max. 2 PCB’s can be mounted in 1 KRP1H98 box. FWF-B: Max. 2 KRP1BA101 boxes can be mounted on the unit. Max. 1 PCB can be mounted in 1 KRP1BA101 box.
18
KRP1BA101 (9) 1.969,KRCS01-1 2.432,-
10. FWC-B - 2-pipe unit: 1 x valve kit + 1 x installation box for PCB KRP1H98 + 1 x valve control PCB EKRP1C11 FWC-B - 4-pipe unit: 2 x valve kit + 1 x installation box for PCB KRP1H98 + 1 x valve control PCB EKRP1C11 FWF-B - 2-pipe unit: 1 x valve kit + 1 x installation box for PCB KRP1BA101 + 1 x valve control PCB EKRP1C11. FWF-B - 4-pipe unit: 2 x valve kit + 1 x installation box for PCB KRP1BA101 + 1 x valve control PCB EKRP1C11. 11. It is possible to change the operation mode, but this will not have an impact on the water temperature. (No feed back to water source) It is not possible to select the “auto air flow” setting. Dry operation can be selected with this remote control, but this function is not available on the FWC-B / FWF-B model. 12. This option is needed to create T1 T2 wire. All options are supplied as kit.
FWV - D, Floor standing fan coil
FWV - D Fan coil
Low Wall unit FWV FWV**DTN, 2 pipe unit, standard, without valve FWV**DTV, 2 pipe unit, with 3-way on/off 230V valve, factory mounted FWV**DTD, 2 pipe unit, with simplified 3-way on/off 230V valve, factory mounted Cooling capacity (Total) Heating capacity (2-pipe at High Speed) FWV**DFN, 4 pipe unit, standard, without valves FWV**DFV, 4 pipe unit, with 3-way on/off 230V valves, factory mounted FWV**DFD, 4 pipe unit, with simplified 3-way on/off 230V valves, factory mounted Cooling capacity (Total) Heating capacity (4-pipe at High Speed)
01
15
02
25
03
35
04
06
08
10
CZK
8.512,-
8.911,-
9.390,-
10.050,-
10.355,-
11.323,-
11.905,-
12.870,-
17.082,-
19.393,-
CZK
14.479,-
14.874,-
15.385,-
16.013,-
16.322,-
17.353,-
18.018,-
18.984,-
23.664,-
25.974,-
CZK
11.283,-
11.616,-
12.080,-
12.743,-
13.008,-
13.939,-
14.736,-
15.664,-
19.845,-
22.036,-
kW kW
1,54 2,14
1,74 2,20
1,96 2,57
2,42 3,20
2,93 3,81
3,51 4,78
4,33 5,10
4,77 5,95
6,71 7,83
8,02 10,03
CZK
9.857,-
10.385,-
10.823,-
11.591,-
11.964,-
12.931,-
13.865,-
14.976,-
19.597,-
21.850,-
CZK
20.622,-
21.105,-
21.558,-
22.311,-
22.728,-
23.651,-
24.628,-
25.711,-
30.888,-
33.199,-
CZK
15.531,-
15.996,-
16.461,-
17.191,-
17.589,-
18.519,-
19.712,-
20.774,-
25.488,-
27.744,-
kW kW
1,46 1,90
1,69 2,02
1,79 2,01
2,38 2,92
2,87 3,08
3,46 4,80
4,26 5,05
4,67 5,30
6,64 7,91
7,88 8,35
01
15
02
25
03 35 on request on request on request on request on request on request on request on request
04
06
08
10
-
on r.
03 35 on request on request on request
04
08
10
Factory mounted options 3-way on/off 24V valve 3-way proportional on/off valves 2-way on/off 230V valve 2-way on/off 24V valves 2-way proportional on/off valve 4-rows coil (for 2 pipe unit only) 6-speeds fan motor Electric heater (for 2 pipe unit only)
CZK CZK CZK CZK CZK CZK CZK CZK
Factory mounted options FWEC1A Standard version FWEC2A Advanced version FWEC3A Advanced Plus version
CZK CZK CZK
-
01
15
02
25
06
Notes: Accessories as kits are included on page 22. Additional single row h/e (4-row coil) can not be used in combination with electric heater. Independent power supply is necessary for 24 V valve. FWEC1/2/3A are not suitable to control 24 V valve. Controller FWEC3A is necessary for proportional valve. Cooling capacity is related to High Speed, standard unit.
Applied Systems Price list 2015-2016
19
FWL - D, Flexi type fan coil
FWL - D Fan coil
Flexible unit FWL FWL**DTN, 2 pipe unit, standard, without valve FWL**DTV, 2 pipe unit, with 3-way on/off 230V valve, factory mounted FWL**DTD, 2 pipe unit, with simplified 3-way on/off 230V valve, factory mounted Cooling capacity (Total) Heating capacity (2-pipe at High Speed) FWL**DFN, 4 pipe unit, standard, without valves FWL**DFV, 4 pipe unit, with 3-way on/off 230V valves, factory mounted FWL**DFD, 4 pipe unit, with simplified 3-way on/off 230V valves, factory mounted Cooling capacity (Total) Heating (4-pipe at High Speed)
01
15
02
25
03
35
04
06
08
10
CZK
8.923,-
9.380,-
10.003,-
10.452,-
11.086,-
11.926,-
12.577,-
13.544,-
18.223,-
20.622,-
CZK
14.772,-
15.276,-
15.796,-
16.281,-
16.935,-
17.889,-
18.633,-
19.597,-
24.775,-
27.144,-
CZK
11.616,-
12.080,-
12.610,-
13.076,-
13.739,-
14.536,-
15.331,-
16.261,-
20.907,-
23.230,-
kW kW
1,54 2,14
1,74 2,20
1,96 2,57
2,42 3,20
2,93 3,81
3,51 4,78
4,33 5,10
4,77 5,95
6,71 7,83
8,02 10,03
CZK
10.472,-
10.921,-
11.291,-
12.127,-
12.577,-
13.936,-
14.683,-
15.650,-
20.826,-
23.049,-
CZK
21.031,-
21.440,-
21.850,-
22.713,-
23.137,-
24.455,-
25.244,-
26.179,-
31.911,-
34.164,-
CZK
15.996,-
16.461,-
16.792,-
17.655,-
18.120,-
19.382,-
20.377,-
21.305,-
26.615,-
28.806,-
kW kW
1,46 1,90
1,69 2,02
1,79 2,01
2,38 2,92
2,87 3,08
3,46 4,80
4,26 5,05
4,67 5,30
6,64 7,91
7,88 8,35
01
15
02
25
03 35 on request on request on request on request on request on request on request on request
04
06
08
10
-
on r.
03 35 on request on request on request
04
08
10
Factory mounted options 3-way on/off 24V valve 3-way proportional on/off valves 2-way on/off 230V valve 2-way on/off 24V valves 2-way proportional on/off valve 4-rows coil (for 2 pipe unit only) 6-speeds fan motor Electric heater (for 2 pipe unit only)
CZK CZK CZK CZK CZK CZK CZK CZK
Factory mounted options FWEC1A Standard version FWEC2A Advanced version FWEC3A Advanced Plus version
CZK CZK CZK
-
01
15
02
Notes: Accessories as kits are included on page 22. Additional single row h/e (4-row coil) can not be used in combination with electric heater. Independent power supply is necessary for 24 V valve. FWEC1/2/3A are not suitable to control 24 V valve. Controller FWEC3A is necessary for proportional valve. Cooling capacity is related to High Speed, standard unit.
20
25
06
FWM - D, Flexi concealed fan coil
FWM - D Fan coil
Flexible concealed unit FWM FWM**DTN, 2 pipe unit, standard, without valve FWM**DTV, 2 pipe unit, with 3-way on/off 230V valve, factory mounted FWM**DTD, 2 pipe unit, with simplified 3-way on/off 230V valve, factory mounted Cooling capacity (Total) Heating capacity (2-pipe at High Speed) FWM**DFN, 4 pipe unit, standard, without valves FWM**DFV, 4 pipe unit, with 3-way on/off 230V valves, factory mounted FWM**DFD, 4 pipe unit, with simplified 3-way on/off 230V valves, factory mounted Cooling capacity (Total) Heating capacity (4-pipe at High Speed)
Factory mounted options 3-way on/off 24V valve 3-way proportional on/off valves 2-way on/off 230V valve 2-way on/off 24V valves 2-way proportional on/off valve 4-rows coil (for 2 pipe unit only) 6-speeds fan motor Electric heater (for 2 pipe unit only)
01
15
02
25
03
35
04
06
08
10
CZK
7.217,-
7.783,-
7.962,-
8.648,-
8.797,-
9.543,-
9.931,-
10.826,-
14.285,-
16.223,-
CZK
13.180,-
13.718,-
13.956,-
14.611,-
14.763,-
15.656,-
16.014,-
16.999,-
20.934,-
22.814,-
CZK
10.546,-
11.112,-
11.292,-
11.977,-
12.126,-
12.871,-
13.538,-
14.432,-
18.031,-
20.037,-
kW kW
1,54 2,14
1,74 2,20
1,96 2,57
2,42 3,20
2,93 3,81
3,51 4,78
4,33 5,10
4,77 5,95
6,71 7,83
8,02 10,03
CZK
8.678,-
9.095,-
9.305,-
9.841,-
10.468,-
11.421,-
11.988,-
12.823,-
16.789,-
18.787,-
CZK
19.414,-
19.681,-
20.039,-
20.726,-
21.231,-
21.918,-
22.754,-
23.589,-
28.091,-
30.090,-
CZK
15.198,-
15.615,-
15.825,-
16.360,-
16.987,-
17.942,-
18.925,-
19.690,-
24.003,-
26.069,-
kW kW
1,46 1,90
1,69 2,02
1,79 2,01
2,38 2,92
2,87 3,08
3,46 4,80
4,26 5,05
4,67 5,30
6,64 7,91
7,88 8,35
01
15
02
25
04
06
08
10
-
on r.
CZK CZK CZK CZK CZK CZK CZK CZK
-
03 35 on request on request on request on request on request on request on request on request
Notes: Accessories as kits are included on page 22. Additional single row h/e (4-row coil) can not be used in combination with electric heater. Independent power supply is necessary for 24 V valve. FWEC1/2/3A are not suitable to control 24 V valve. Controller FWEC3A is necessary for proportional valve. Cooling capacity is related to High Speed, standard unit.
Applied Systems Price list 2015-2016
21
Accessories for FWV - FWL - FWM
FWV – FWL – FWM Accessories Accessories as a kit for FWV/FWL/FWM Additional heat exchanger Electric heater 2-pipe 3-ways 230V on/off valve kit 4-pipe 3-ways 230V on/off valve kit 2-ways 230V on/off valve kit cooling h/e 2-ways 230V on/off valve kit additional h/e 2-pipe simplified 3-ways 230V on/off valve kit 4-pipe simplified 3-ways 230V on/off valve kit 2-pipe 3-ways 24V on/off valve kit 4-pipe 3-ways 24V on/off valve kit 2-pipe 3-ways proportional valve kit 4-pipe 3-ways proportional valve kit 2-ways 24V on/off valve kit cooling h/e 2-ways 24V on/off valve kit additional h/e 2-ways proportional valve kit cooling h/e 2-ways proportional valve kit additional h/e Fan stop thermostat Air intake & discharge grille Supporting feet Supporting feet & grille Fresh air intake Rear panel Plenum box with circular connections (only for FWM-D) Vertical auxiliary drainpan Horizontal auxiliary drainpan
Controller as a kit for FWV/FWL/FWM ECFWMB6 Controller electromechanical, Built in Wired remote controller, FWEC1A Standard version Wired remote controller, FWEC2A Advanced version Wired remote controller, FWEC3A Advanced Plus version On board mounting kit, for FWEC*A, FWECKA remote airprobe incl. Wall mounting kit (spacing collar), for FWFCKA FWEC*A FWTSKA Temperature sensor kit , for FWEC*A Relative humidity sensor kit , FWHSKA for FWEC2A and FWEC3A EPIMSB6 Master / Slave interface
22
1
CZK CZK CZK CZK CZK CZK CZK CZK CZK CZK CZK CZK CZK CZK CZK CZK CZK CZK CZK CZK CZK CZK CZK CZK CZK
15 2 25 3 35 ESRH02A6 ESRH03A6 1.649,1.979,EEH01A6 EEH02A6 EEH03A6 7.435,7.435,7.974,E2MV03A6 5.187,E4MV03A6 9.711,E2MV2B07A6 2.727,E2MV2B07A6 2.727,E2MVD03A6 3.459,E4MVD03A6 6.353,E2M2V03A6 5.929,E4M2V03A6 10.588,E2MPV03A6 9.316,E4MPV03A6 17.152,E2M2V207A6 2.542,E2M2V207A6 2.542,E2MPV207A6 6.493,E2MPV207A6 6.493,YFSTA6 510,EAIDF02A6 EAIDF03A6 4.797,5.905,ESFV06A6 510,ESFVG02A6 ESFVG03A6 839,1.020,EFA02A6 EFA03A6 2.099,2.129,ERPV02A6 ERPV03A6 898,1.230,EPCC02A6 EPCC03A6 2.612,2.894,EDPVB6 143,EDPHB6 143,-
CZK
all sizes 1.049,-
CZK
2.638,-
CZK
4.137,-
CZK
5.636,-
CZK
451,-
CZK
451,-
CZK
239,-
CZK
629,-
CZK
3.599,-
4 6 ESRH06A6 2.188,EEH06A6 8.305,E2MV06A6 5.547,E4MV06A6 10.120,-
8 10 ESRH10A6 2.909,EEH10A6 8.635,E2MV10A6 5.997,E4MV10A6 10.589,E2MV2B10A6 2.879,-
E2MVD06A6 3.529,E4MVD06A6 6.493,E2M2V06A6 5.929,E4M2V06A6 10.588,E2MPV06A6 9.176,E4MPV06A6 17.222,-
E2MVD10A6 3.529,E4MVD10A6 6.564,E2M2V10A6 6.282,E4M2V10A6 11.152,E2MPV10A6 9.458,E4MPV10A6 17.434,E2M2V210A6 2.542,-
E2MPV210A6 6.493,-
EAIDF06A6 7.376,-
ESFVG06A6 1.169,EFA06A6 2.369,ERPV06A6 1.379,EPCC06A6 3.600,-
EAIDF10A6 8.725,ESFV10A6 629,ESFVG10A6 1.619,EFA10A6 2.698,ERPV10A6 1.769,EPCC10A6 5.012,-
FWZ - A, Floor standing fan coil with DC fan motor
FWZ - A Fan coil Low sound level and up to 70% energy saving thanks to the BLDC motor technology
Low Wall unit with DC fan motor FWZ FWZ**ATN, 2 pipe unit, standard, without valve FWZ**ATV, 2 pipe unit, with 3-way on/off 230V valve, factory mounted FWZ**ATD, 2 pipe unit, with simplified 3-way on/off 230V valve, factory mounted Cooling capacity (Total) Heating capacity (2-pipe at High Speed) FWZ**AFN, 4 pipe unit, standard, without valves FWZ**AFV, 4 pipe unit, with 3-way on/off 230V valves, factory mounted FWZ**AFD, 4 pipe unit, with simplified 3-way on/off 230V valves, factory mounted Cooling capacity (Total) Heating capacity (4-pipe at High Speed)
02
03
06
08
CZK
13.739,-
14.536,-
16.792,-
20.974,-
CZK
19.381,-
20.178,-
22.633,-
27.280,-
CZK
16.660,-
17.457,-
19.846,-
24.226,-
kW kW
2,64 3,47
4,96 6,40
6,32 7,51
10,08 11,18
CZK
14.934,-
15.863,-
18.850,-
23.098,-
CZK
25.155,-
26.085,-
29.071,-
33.916,-
CZK
20.774,-
21.704,-
24.957,-
29.536,-
kW kW
2,43 2,46
4,96 4,19
6,32 6,45
10,08 10,06
02
03
06
08
06
08
Factory mounted options 3-way on/off 24V valve 2-way on/off 230V valve 2-way on/off 24V valves 4-rows coil (for 2 pipe unit only) Electric heater (for 2 pipe unit only)
CZK CZK CZK CZK CZK
Factory mounted options FWEC3A Advanced Plus version
CZK
on request on request on request on request on request 02
03 on request
Notes: Accessories as kits are included on page 26. Additional single row h/e (4-row coil) can not be used in combination with electric heater. Independent power supply is necessary for 24 V valve. FWEC3A are not suitable to control 24 V valve. Controller FWEC3A is necessary to control DC fan motor. Cooling capacity is related to High Speed, standard unit.
Applied Systems Price list 2015-2016
23
FWR - A, Flexi type fan coil with DC fan motor
FWR - A Fan coil Low sound level and up to 70% energy saving thanks to the BLDC motor technology
FLEXI type unit with DC fan motor FWR FWR**ATN, 2 pipe unit, standard, without valve FWR**ATV, 2 pipe unit, with 3-way on/off 230V valve, factory mounted FWR**ATD, 2 pipe unit, with simplified 3-way on/off 230V valve, factory mounted Cooling capacity (Total) Heating capacity (2-pipe at High Speed) FWR**AFN, 4 pipe unit, standard, without valves FWR**AFV, 4 pipe unit, with 3-way on/off 230V valves, factory mounted FWR**AFD, 4 pipe unit, with simplified 3-way on/off 230V valves, factory mounted Cooling capacity (Total) Heating capacity (4-pipe at High Speed)
02
03
06
08
CZK
14.337,-
15.531,-
17.921,-
22.899,-
CZK
19.979,-
21.173,-
23.762,-
29.204,-
CZK
17.257,-
18.451,-
20.974,-
26.085,-
kW kW
2,64 3,47
4,96 6,40
6,32 7,51
10,08 11,18
CZK
15.664,-
16.925,-
19.846,-
25.222,-
CZK
25.886,-
27.147,-
30.133,-
36.041,-
CZK
21.505,-
22.766,-
26.019,-
31.660,-
kW kW
2,43 2,46
4,96 4,19
6,32 6,45
10,08 10,06
02
03
06
08
06
08
Factory mounted options 3-way on/off 24V valve 2-way on/off 230V valve 2-way on/off 24V valves 4-rows coil (for 2 pipe unit only) Electric heater (for 2 pipe unit only)
CZK CZK CZK CZK CZK
Factory mounted options FWEC3A Advanced Plus version
CZK
on request on request on request on request on request 02
Notes: Accessories as kits are included on page 26. Additional single row h/e (4-row coil) can not be used in combination with electric heater. Independent power supply is necessary for 24 V valve. FWEC1/2/3A are not suitable to control 24 V valve. Controller FWEC3A is necessary to control DC fan motor. Cooling capacity is related to High Speed, standard unit.
24
03 on request
FWS - A, Flexi type fan coil with DC fan motor
FWS - A Fan coil Low sound level and up to 70% energy saving thanks to the BLDC motor technology
FLEXI type unit with DC fan motor FWS FWS**ATN, 2 pipe unit, standard, without valve FWS**ATV, 2 pipe unit, with 3-way on/off 230V valve, factory mounted FWS**ATD, 2 pipe unit, with simplified 3-way on/off 230V valve, factory mounted Cooling capacity (Total) Heating capacity (2-pipe at High Speed) FWS**AFN, 4 pipe unit, standard, without valves FWS**AFV, 4 pipe unit, with 3-way on/off 230V valves, factory mounted FWS**AFD, 4 pipe unit, with simplified 3-way on/off 230V valves, factory mounted Cooling capacity (Total) Heating capacity (4-pipe at High Speed)
02
03
06
08
CZK
12.279,-
13.142,-
15.067,-
18.784,-
CZK
17.987,-
18.784,-
20.907,-
25.089,-
CZK
15.200,-
16.062,-
18.186,-
22.036,-
kW kW
2,64 3,47
4,96 6,40
6,32 7,51
10,08 11,18
CZK
13.540,-
14.735,-
16.925,-
21.107,-
CZK
23.828,-
24.957,-
27.147,-
31.926,-
CZK
19.381,-
20.576,-
23.031,-
27.479,-
kW kW
2,43 2,46
4,96 4,19
6,32 6,45
10,08 10,06
02
03
06
08
06
08
Factory mounted options 3-way on/off 24V valve 2-way on/off 230V valve 2-way on/off 24V valves 4-rows coil (for 2 pipe unit only) Electric heater (for 2 pipe unit only)
CZK CZK CZK CZK CZK
Factory mounted options FWEC3A Advanced Plus version
CZK
on request on request on request on request on request 02
03 on request
Notes: Accessories as kits are included on page 26. Additional single row h/e (4-row coil) can not be used in combination with electric heater. Independent power supply is necessary for 24 V valve. FWEC3A are not suitable to control 24 V valve. Controller FWEC3A is necessary to control DC fan motor. Cooling capacity is related to High Speed, standard unit.
Applied Systems Price list 2015-2016
25
Accessories for FWZ - FWR - FWS
FWZ - FWR - FWS Accessories Accessories as a kit for FWZ/FWR/FWS Additional heat exchanger Electric heater 2-pipe 3-ways 230V on/off valve kit 4-pipe 3-ways 230V on/off valve kit 2-ways 230V on/off valve kit cooling h/e 2-ways 230V on/off valve kit additional h/e 2-pipe simplified 3-ways 230V on/off valve kit 4-pipe simplified 3-ways 230V on/off valve kit 2-pipe 3-ways 24V on/off valve kit 4-pipe 3-ways 24V on/off valve kit 2-ways 24V on/off valve kit cooling h/e 2-ways 24V on/off valve kit additional h/e Air intake & discharge grille Supporting feet Supporting feet & grille Fresh air intake Rear panel Plenum box with circular connections (only for FWS-A) Vertical auxiliary drainpan Horizontal auxiliary drainpan
Controller as a kit for FWZ / FWR / FWS Wired remote controller, FWEC3A Advanced Plus version On board mounting kit, for FWEC*A, FWECKA remote airprobe incl. Wall mounting kit (spacing collar), for FWFCKA FWEC*A Temperature sensor kit, FWTSKA for FWEC*A Relative humidity sensor kit , FWHSKA for FWEC2A and FWEC3A
26
CZK CZK
02 ESRH02A6 1.649,EEH02A6 7.435,-
CZK CZK CZK CZK CZK CZK CZK CZK CZK EAIDF02A6 4.797,-
CZK CZK CZK CZK CZK CZK CZK
06 ESRH06A6 2.188,EEH06A6 8.305,E2MV06A6 5.547,E4MV06A6 10.120,-
E2MV03A6 5.187,E4MV03A6 9.711,-
CZK
CZK
03 ESRH03A6 1.979,EEH03A6 7.974,-
ESFVG02A6 839,EFA02A6 2.099,ERPV02A6 898,EPCC02A6 2.612,-
E2MV2B07A6 2.727,E2MV2B07A6 2.727,E2MVD03A6 E2MVD06A6 3.459,3.529,E4MVD03A6 E4MVD06A6 6.353,6.493,E2M2V03A6 E2M2V06A6 5.929,5.929,E4M2V03A6 E4M2V06A6 10.588,10.588,E2M2V207A6 2.542,E2M2V207A6 2.542,EAIDF03A6 EAIDF06A6 5.905,7.376,ESFV06A6 510,ESFVG03A6 ESFVG06A6 1.020,1.169,EFA03A6 EFA06A6 2.129,2.369,ERPV03A6 ERPV06A6 1.230,1.379,EPCC03A6 EPCC06A6 2.894,3.600,EDPVB6 143,EDPHB6 143,all sizes
CZK
5.636,-
CZK
451,-
CZK
451,-
CZK
239,-
CZK
629,-
08 ESRH10A6 2.909,EEH10A6 8.635,E2MV10A6 5.997,E4MV10A6 10.589,E2MV2B10A6 2.879,-
E2MVD10A6 3.529,E4MVD10A6 6.564,E2M2V10A6 6.282,E4M2V10A6 11.152,E2M2V210A6 2.542,-
EAIDF10A6 8.725,ESFV10A6 629,ESFVG10A6 1.619,EFA10A6 2.698,ERPV10A6 1.769,EPCC10A6 5.012,-
Air Handling Units - AHU
D-AHU Modular Series D-AHU Modular specification: Panel type: э Internal Skin Material: Aluzinc® э External Skin finishing: Aluzinc® or Pre-Painted э Insulation material: Mineral Wool or Polyurethane э Panel Type: SP45 Construction Structure: э Frame: Anodized Aluminum э Frame Type: Internal Rounded Main Components & Calculation input: э Heat Wheel: Sensible type э Fans (Standard Pressure): EC Fan IE4 Mot. э Unit Installation: Indoor (without roof ) э Filters Efficiency: G4 / G7 Main Module Configuration: э Plug & Play factory mounted Controls
Main module nominal Performances Size Airflow Temp efficiency winter ESP nominal Current nominal Power input nominal SFPv Electrical supply Lenght Depth Height overall Weight Sound level - Lp*
m3/h % Pa A kW kW/m3/s V-ph-Hz mm mm mm kg dB(A)
1 1200 81.3 200 2.66 0.62 1.87 230-1-50 1700 720 1320 325 40
2 1700 81.1 200 3.9 0.89 1.89 230-1-50 1700 820 1320 350 42
3 2700 81.4 200 6.3 1.5 1.99 230-1-50 1800 990 1540 475 42
4 4100 81.6 200 2.98 1.98 1.74 400-3+N-50 1920 1200 1740 575 45
5 5500 82.6 200 4 2.68 1.75 400-3+N-50 2080 1400 1740 750 46
6 6100 81.2 200 4.74 2.96 1.75 400-3+N-50 2280 1400 1920 790 44
7 7000 82.7 200 4.76 3.3 1.7 400-3+N-50 2400 1600 1920 950 43
8 9100 81.4 200 5.54 3.76 1.49 400-3+N-50 2450 1940 2180 1330 43
9 11500 81.5 200 8.72 5.48 1.72 400-3+N-50 2280 1940 2460 1410 45
10 15000 83.2 200 10.2 7.04 1.69 400-3+N-50 2400 2300 2570 1750 45
* Sound pressure level radiated from unit at 1 meter and according to ISO 3744 (supply outlet ducted) Size Main Module Size Mode Cooling Coil Cooling+Heating Coil Dx HP
CZK
1 350.850,-
2 363.386,-
3 408.449,-
4 448.508,-
5 488.567,-
6 520.495,-
7 576.240,-
8 671.526,-
9 770.878,-
10 863.812,-
1
2
3
4
5
6
7
8
9
10
Coil's Row 6
CZK
55.307,-
60.728,-
71.390,-
85.201,-
96.064,-
115.376,-
99.950,-
130.283,-
140.787,-
163.308,-
6+2
CZK
78.843,-
84.943,-
97.239,-
116.551,-
129.167,-
150.353,-
136.622,-
171.279,-
168.908,-
233.781,-
4
CZK
69.456,-
71.828,-
78.943,-
117.827,-
123.248,-
132.317,-
-
-
-
-
Size Three way mixing box
CZK
1 29.397,-
2 29.915,-
3 32.107,-
4 36.412,-
5 38.704,-
6 39.820,-
7 45.998,-
8 52.356,-
9 57.020,-
10 61.923,-
Size Outdoor Kit (Roof)
CZK
1 7.036,-
2 7.713,-
3 9.407,-
4 11.958,-
5 15.346,-
6 16.104,-
7 17.798,-
8 21.684,-
9 23.039,-
10 25.849,-
1
2
3
4
5
6
7
8
9
10
CZK
3.827,-
3.827,-
6.438,-
7.633,-
10.264,-
10.264,-
11.440,-
18.296,-
18.296,-
24.494,-
CZK
38.804,-
39.900,-
46.757,-
54.210,-
59.730,-
65.311,-
76.153,-
89.884,-
105.371,-
111.908,-
1
2
3
4
5
6
7
8
9
10
33.722,-
38.286,-
48.450,-
64.035,-
73.024,-
78.524,-
93.951,-
106.726,-
127.493,-
174.668,-
1
2
3
4
5
6
7
8
9
10
Size M6 Filter (to replace G4) Additional Filtration Module F9 front withdrawal Size Sorption Type Heat Wheel (to replace sensible type on main module) Size Bacnet Module (for ITM Daikin)
Applied Systems Price list 2015-2016
CZK
CZK
7.633,-
27
Air cooled and condensing units
Products overview
EWAQ~E-
R-410A
1
EWAQ~F-
R-410A
2
EWAQ~GZ
R-410A
1-2
EWAD~E-
R-134a
1
EWAD~D-
R-134a
2
EWAD~TZ
R-134a
1-2
EWAD~C-
R-134a
2-3
EWAD~CZ
R-134a
2-3
EWAD~CF
R-134a
2
EWYQ~ADVP
R-410A
1
EWYQ~ACV3/ACW1
R-410A
1
EWYQ~BA*
R-410A
1
R-410A
1
EWYQ~F-
R-410A
2
EWYQ~GZ
R-410A
1-2
EWYD~BZ
R-134a
2-3
R-134a
1
High
Extra low
1
Reduced
R-410A
Low
Standard
1
Sound version
High ambient
R-410A
Standard
EWAQ~BA*
Single pass shell and tube
Plate heat exchanger
1
Brazed plate
R-410A
Screw
EWAQ~ACV3/ACW1
Scroll
Swing
1
Free cooling
R-410A
Inverter
EWAQ~ADVP
Premium
Efficiency version
Refrigerant circuit(s)
Water heat exchanger
Refrigerant type
Compressor
Cooling only
EWAQ~G
NEW
Heat pump
SEHVX-AAW SERHQ-AAW1
NEW
Condensing unit ERAD~E-
28
Air cooled and condensing units
Cooling capacity (kW) Heating capacity (kW)
0
17.5
200
500
1,000
2,000
5.3~7.2 8.6~17.0 16.6~64.5 75~160 kW 172~334 165~672 196~395 98~411 177~620 170~710 696~1,795 602~1,555 617~2,002 0
17.5
200
500
1,000
2,000
500
1,000
2,000
5.3~7.2 5.6~8.2 8.6~17.0 9.9~14.8 16.6~64.5 16.2~63.7 20.7~74.3 21.3~63.7 158~624 173~674 188~380 182~362 247~580 271~618 0
17.5
200 116~488
Applied Systems Price list 2015-2016
29
Water cooled and condenserless units
Products overview High
Efficiency version
Standard
Single pass shell and tube
Plate heat exchanger
Brazed plate
Water heat exchanger Centrifugal
Screw
1-2-4-6
Scroll
Refrigerant circuit(s)
R-407C
Inverter
Refrigerant type
Compressor
Water cooled Scroll and Screw chillers EWWP~KBW1N
EWWQ-G
NEW
R-410A
1
EWWQ-L
NEW
R-410A
2
EWWD~J-
R-134a
1-2
EWWD~G-
R-134a
1-2
EWWD~I-
R-134a
1-2-3
EWWD~H-
R-134a
1
Flooded
EWWQ~B-
R-410A
1-2
R-407C
1-2
Condenserless chillers EWLP~KBW1N
EWLQ-G
NEW
R-410A
1
EWLQ - L
NEW
R-410A
2
EWLD~J-
R-134a
1-2
EWLD~G-
R-134a
1-2
EWLD~I-
R-134a
1-2-3
EWWD~FZ
R-134a
1
DWSC DWDC
R-134a
6,000 RT CENTRIFUGAL
R-134a
Water cooled centrifugal chillers
optional
Flooded
Large Chillers options and accessories summary э Depending on the type and size of chiller a wide range of options and accessories is available. E.g.
э Brine (glycol) application э Star delta compressor starter э Thermal relays for compressors э Thermal relays for fans э Under/over voltage controller э Phase monitor device э Condenser coils with special anti corrosion treatment 30
э Flow switch for evaporator (kit for field installation) э Victaulic connections э Rubber type ant vibration mounts э Evaporator heater э Main switch э Suction and discharge stop valves on compressors э Dual set point possibility
э Set point reset and demand limit possibility э General fault contact э Single pump э Twin pump э Total heat recovery э Partial heat recovery э Low ambient application э Power factor 0.9 correction device
Water cooled and condenserless units
Cooling capacity (kW) Heating capacity (kW) 0
17.5
200
500
1,000
2,000 21800
1,000
2,000 21800
1,000
2,000 21800
12.9~194 16.7~249 93~415 110~510 184~722 225~885 120~568 142~681 165~602 209~743 332~1,503 424~1,951 368~1,212 454~1,488 379~2,156 0
17.5
200
500
12.1~62.4 93~415 184~722 110~529 160~524 315~1,433 0
17.5
200
500 113~1,054 300~4,500
600~9,000 [ 2 x 10,900 ]
Daikin Europe N.V. participates in the Eurovent Certification programme for Air conditioners (AC), Liquid Chilling Packages (LCP), Air handling units (AHU) and Fan coil units (FCU), Check ongoing validity of certificate online: www.eurovent-certification.com or using: www.certiflash.com
э A/V meter э Coil guards э Soft starter э Low noise version э Refrigerant Gauges э Coil guards э Cu/Cu condenser coils э High ESP fans э Cu/Ni heat exchanger Applied Systems Price list 2015-2016
э Dual pressure relieves safety valves э Different address card э Different bus communication gateways (LonTalk, Bacnet, Modbus,…) э Chiller Sequencing Panel э Different Modems (fixed and GSM) э Plant Watch PRO monitoring system э Remote user interface
21,800
Air cooled: Eurovent certified up to 600kW Water cooled: Eurovent certified up to 1500kW Nominal cooling capacities are based on Eurovent conditions: Evaporator: 12°C/7°C — Ambient: 35°C Nominal heating capacities are based on Eurovent conditions: Ambient: 7°CDB/6°CWB — Condenser: 40°C/45°C
For the exact availability of the chiller which fits best your application please get in contact with your Daikin sales responsible.
31
Total solution products
AIR COOLER
COOLING TOWER
1-162 kW
70-9.200 kW
On request we can offer you the most suitable air cooler for your application based on a brine/water solution.
On request we can offer you the most suitable cooling tower for your application. For correct selection we need following info: э Heat rejection capacity (kW) or chiller type and working conditions э Liquid inlet and outlet temperature э Liquid type э Maximum/Minimum ambient temperature э Maximum sound level э Space restrictions
AIR HANDLING UNIT 3
500-140.000 m /h
On request we can offer you the most suitable air handling unit for your application. э Air handling units for filtering, heating, cooling, humidifying, and air drying э Air handling units with heat recovery э Air handling units for outdoor installation э Air handling units in hygienic execution for hospital and clean room э Air handling units with indirect gas fired heating э Air handling units for swimming pool applications э Air handling units with higher air volumes manufactured on request э Air handling units with thermal uncoupled frame
COMPRESSOR
Inspection/repair/overhaul To extend the lifetime of your compressor, Daikin offers a compressor overhaul service as preventive maintenance. In case of broken compressor, Daikin can offer an inspection to determine whether the compressor is repairable or not. Based on the findings the broken parts will be replaced and the compressor will be restored into operational condition. Inspection Inspection fee/compressor*
on request
Repair
DRY COOLER & CONDENSER
3-2.400 kW
Repair cost/compressor*
After inspection, on quotation base
Overhaul Overhaul cost/compressor*
on request
Remarks
On request we can offer you the most suitable dry cooler and condenser for your application. For correct selection we need following info: э Heat rejection capacity (kW) or chiller type and working conditions э Liquid inlet and outlet temperature (dry cooler) э Liquid type (dry cooler) э Condensing temperature (condenser) э Refrigerant type and number of circuits (condenser) э Maximum/Minimum ambient temperature э Maximum sound level э Space restrictions
32
The above is only valid for DAIKIN semi-hermetic compressors * Excluding transport cost and other site related costs
Measuring conditions
MENTIONED CAPACITIES, EFFICIENCY RATIOS, SOUND POWER LEVELS, DIMENSIONS Weights are indicative and valid under the following conditions: Chillers Cooling Heating Heat recovery Condenserless units Cooling Cooling Water cooled units Heating
7 °C / 12 °C water 40 °C / 45 °C water 7 °C / 12 °C water 7 °C / 12 °C water 7 °C / 12 °C evaporator water 7 °C / 12 °C evaporator water
40°C / 45°C heat recovery 45 °C condensing temp / 5 K subcooling 30 °C / 35 °C condenser water 40 °C / 45 °C condenser water
Cooling: Heating:
indoor temperature: 27 °C db / 19 °C wb indoor temperature: 20 °C db
outdoor temperature: 35 °C outdoor temperature: 7 °C db / 6 °C wb
Cooling: Heating:
evaporation temperature: 6 °C condensing temperature: 46 °C evaporator superheat: 5K condenser sub-cool: 3K 7,5 m equivalent refrigerant piping 0 m level difference
outdoor temperature: 35 °C outdoor temperature: 7 °C
Air cooled units
35 °C ambient temp 7 °C ambient temp 35 °C ambient temp
Rooftops
Condensing units
General:
on-coil temperature: 27 °CDB / 19 °CWB on-coil temperature: 20 °CDB
Fan coil units Cooling: Heating:
Applied Systems Price list 2015-2016
Room temperature DB/WB: 27 °C/19 °C Entering/Leaving water temperature: 7 °C/12 °C Room temperature: 20 °C Entering water temperature: 50 °C (2-pipe,water flow rate same as for the cooling) / 70 °C (4-pipe, water temperature leaving 60°C)
33
Notes
34
Všeobecné obchodní podmínky I. OBECNÁ USTANOVENÍ 1. Všechna práva a povinnosti ze smluv, v nichž má společnost DAIKIN AIRCONDITIONING CENTRAL EUROPE – CZECH REPUBLIC spol. s r.o., se sídlem Praha 8, Pobřežní 3, PSČ 186 00, IČ: 480 39 497, zapsaná v obchodním rejstříku vedeném Městským soudem v Praze, oddílu C, vložce 15503 (dále jen „DAIKIN“) postavení prodávajícího (dodavatele), a druhá smluvní strana postavení kupujícího (objednatele) (dále jen „zákazník“), jejichž předmětem je prodej (dodání) jakéhokoliv zboží (dále souhrnně jen „zboží“) DAIKINem zákazníkovi, které nejsou odchylně upraveny příslušnou smlouvou, se řídí těmito všeobecnými obchodními podmínkami. 2. Pro dodávky a plnění DAIKIN jsou rozhodující výhradně níže uvedené všeobecné obchodní podmínky DAIKIN. Potvrzení zákazníka s odkazem na jeho obchodní nebo nákupní podmínky jsou aplikovatelné pouze v rozsahu, v jakém jsou shodné s těmito všeobecnými obchodními podmínkami. Odchylné doplňky a změny vyžadují ke své právní účinnosti výslovný souhlas DAIKIN a písemnou formu. 3. Tyto Všeobecné obchodní podmínky je možné si stáhnout na domovské stránce www.daikin.cz, jmenovitě na odkazu (Všeobecné obchodní podmínky) „VOP“. 4. K iniciování procesu uzavření smlouvy na dodávku zboží mezi DAIKINem a zákazníkem může dojít jedním z následujících způsobů: i. písemnou (dopisem, faxem nebo e-mailem) nabídkou DAIKINu na dodání zboží doručenou zákazníkovi; a/nebo ii. písemnou (dopisem, faxem nebo e-mailem) objednávkou zboží zákazníka doručenou DAIKINu. 5. Zákazník uzavřením smlouvy s DAIKINem výslovně přijímá veškerá ustanovení těchto všeobecných obchodních podmínek. Pro vyloučení pochybností se vylučuje uplatnění ustanovení § 1799 a 1800 zákona č. 89/2012 Sb., občanského zákoníku, ve znění pozdějších předpisů (dále jen „občanský zákoník“). Veškerá ujednání v rámci konkrétní smlouvy odpovídají obchodním zvyklostem a zásadě poctivého obchodního styku. II. NABÍDKA 1. Není- li v nabídce DAIKIN výslovně uvedeno jinak, nabídky DAIKIN jsou otevřené, orientační a nezávazné. Není-li v nabídce DAIKIN výslovně uvedeno jinak, údaje o mírách, hmotnostech, technických datech, množství a dodacích lhůtách jsou pouze orientační. 2. Ústní a telefonické dohody a ujednání musí být DAIKINem a zákazníkem písemně (dopisem, faxem nebo e-mailem) potvrzeny. III. OBJEDNÁVKY 1. Zákazník je povinen objednávat u DAIKINu zboží písemně (dopisem, faxem nebo e-mailem). 2. Ústní a telefonické dohody a ujednání musí být DAIKINem a zákazníkem písemně (dopisem, faxem nebo e-mailem) potvrzeny. IV. ZMĚNA PŘEDMĚTU PLNĚNÍ 1. Zrušení celé DAIKINem již akceptované objednávky nebo její části zákazníkem, příp. změna DAIKINem již akceptované objednávky zákazníkem jsou přípustné pouze s předchozím písemným souhlasem DAIKINu. V případě zrušení celé DAIKINem již akceptované objednávky nebo její části zákazníkem, příp. při změně DAIKINem již akceptované objednávky zákazníkem je DAIKIN vedle již poskytnutých plnění a vzniklých nákladů oprávněn účtovat zákazníkovi stornopoplatek ve výši 20% sjednané kupní ceny (ceny díla) zakázky včetně DPH, nejméně však 7 000 Kč. Pro specifické produktové skupiny zboží (např. „multiple scroll and screw chiller“) se aplikují zvláštní podmínky na zrušení DAIKINem již akceptované objednávky nebo její části zákazníkem, příp. změnu DAIKINem již akceptované objednávky zákazníkem, které jsou dostupné na www.daikin.cz, (v sekci „VOP“). 2. Pravidla uvedená v čl. IV odst. 1 těchto Všeobecných obchodních podmínek se plně uplatní i na případy, kdy smlouva na dodávku zboží byla mezi DAIKINem a zákazníkem uzavřena na základě nabídky DAIKINu ve smyslu čl. I odst. 4 písm. i a čl. II těchto Všeobecných obchodních podmínek. 3. V případě, že bude proti zákazníkovi zahájeno insolvenční řízení a/nebo zákazník vstoupí do likvidace, je DAIKIN oprávněn od smlouvy odstoupit a/nebo pozastavit plnění veškerých svých závazků ze smlouvy, a to až do doby, než zákazník řádně splní veškeré své povinnosti ze smlouvy pro něj vyplývající, a to aniž by DAIKIN byl povinen nahradit zákazníkovi případně vzniklou újmu. V. CENY A PLATEBNÍ PODMÍNKY 1. Kupní cena zboží (cena díla) (dále jen „cena“) se sjednává ve výši: i. v případě, že je smlouva na dodávku zboží mezi DAIKINem a zákazníkem uzavírána na základě nabídky DAIKINu ve smyslu čl. I odst. 4 písm. i a čl. II těchto Všeobecných obchodních podmínek, ve výši uvedené v takové nabídce DAIKINu; ii. v případě, že je smlouva na dodávku zboží mezi DAIKINem a zákazníkem uzavírána na základě objednávky zákazníka ve smyslu čl. I odst. 4 písm. ii a čl. III těchto Všeobecných obchodních podmínek, dle ceníků a “Dohody o vzájemné spolupráci“ s DAIKINem platných ke dni objednání zboží zákazníkem. Ceníky DAIKIN se zpravidla aktualizují jednou ročně. Změny cen DAIKINem však zůstávají vyhrazeny i v průběhu roku. DAIKIN je tedy oprávněn jednostranně měnit ceníky zboží a zavazuje se seznámit kupujícího s platnými ceníky (dopisem, emailem, faxem či publikací nového ceníku na domovské internetové stránce DAIKINu www.daikin.cz). Zákazník cenu zboží dle nového ceníku akceptuje svou objednávkou učiněnou za platnosti a účinnosti nového ceníku, který byl DAIKINem zákazníkovi oznámen a/nebo zpřístupněn (tj. např. tím, že zákazník objedná u DAIKINu zboží poté, co bude nový platný ceník poslán zákazníkovi anebo publikován na domovské internetové stránce DAIKINu ve smyslu výše uvedeného). 2. Ceny se rozumí netto bez jakýchkoli daní, poplatků nebo odvodů v uvedené měně včetně balného, není-li uvedeno jinak, na předem ve smlouvě dohodnuté místo určení. DAIKIN nepřijímá zpět jakékoliv obaly a balicí materiál. 3. Není- li v konkrétní smlouvě výslovně sjednáno jinak, je zákazník povinen zaplatit DAIKINu cenu zboží na základě DAIKINem vystavené faktury. 4. DAIKIN si vyhrazuje právo na částečná vyúčtování. 5. K reklamacím faktur, doručeným DAIKINu později než 2 týdny po obdržení faktury, se nepřihlíží. Není-li uvedeno v konkrétním případě jinak, činí splatnost faktur 30 dní od data vystavení faktury, přičemž dnem platby je den připsání příslušné fakturované platby beze srážek na účet DAIKINu. V případě prodlení zákazníka s úhradou ceny je zákazník povinen uhradit DAIKINu smluvní pokutu ve výši 0,05% denně z dlužné částky za každý i započatý den prodlení. Tím není dotčeno právo DAIKINu na náhradu škody v plném rozsahu. Dále je DAIKIN v případě prodlení zákazníka oprávněn požadovat po zákazníkovi náhradu veškerých nákladů spojených s vymáháním pohledávky, zejména výlohy na upomínky a inkasní náklady a zákazník je povinen tyto na výzvu DAIKINu nejpozději do pěti (5) dnů v plné výši uhradit. 6. V případě sjednání splátek na úhradu ceny se DAIKIN a zákazník ve smyslu § 1931 občanského zákoníku dohodli, že nesplní-li zákazník některou splátku, má DAIKIN právo na vyrovnání celé pohledávky. Toto právo může DAIKIN uplatnit nejpozději do splatnosti nejblíže příští splátky. 7. DAIKIN je oprávněn podmínit expedici zboží platbou předem, a to v jakékoliv výši až do 100% ceny. 8. Zákazník není oprávněn bez předchozího písemného souhlasu DAIKIN zadržovat platby a/nebo jednostranně započítat jakékoliv své pohledávky za DAIKINem na cenu zboží či jakoukoliv jinou pohledávku DAIKINu za zákazníkem. VI. DODACÍ LHŮTA 1. Není-li výslovně uvedeno jinak, dodací lhůty uvedené v nabídce jsou pouze orientační a nezávazné, DAIKIN však usiluje o dodržení uvedených lhůt. Prodlení s dodáním zboží oproti nabídce proto nemají za následek např. nároky na náhradu škody, resp. újmy, ani neopravňují k odstoupení smlouvy. Totéž platí, jestliže dodací lhůty nebyly dodrženy v důsledku vyšší moci, stávky nebo jiných událostí, které DAIKIN nemůže ovlivnit. 2. Požadavky zákazníka na smluvní pokuty či jiné penále jsou vyloučeny. 3. Dílčí dodávky DAIKINem zákazníkovi jsou přípustné. Při dílčí (částečné) dodávce nenáleží zákazníkovi náhrada nákladů částečnou dodávkou způsobených. 4. Je-li zákazník v prodlení s jakoukoliv splatnou platbou vůči DAIKINu, je DAIKIN oprávněn zadržet a pozastavit dodávky zboží zákazníkovi až do okamžiku úhrady všech splatných závazků zákazníka vůči DAIKINu, aniž by byl povinen nahradit zákazníkovi případně vzniklou újmu. V takovém případě není DAIKIN v prodlení s plněním svého závazku k dodání zboží. VII. PŘEVZETÍ DODÁVKY, PŘECHOD NEBEZPEČÍ ŠKODY NA ZBOŽÍ, PRODLENÍ S PŘEVZETÍM 1. Dodávky zboží se provádějí, není-li sjednáno něco jiného, podle dodací doložky CIP dle Incoterms 2010 na předem dohodnuté místo určení. 2. Dodávky zboží podle dodací doložky CIP dle čl. VII odst. 1 těchto Všeobecných obchodních podmínek pokrývají pouze minimální přepravní náklady. Zvláštní pojištění pro přepravu zboží se uzavírá pouze po zvláštní písemné dohodě a na náklady zákazníka. 3. Zákazník je povinen zkontrolovat bez zbytečného odkladu zboží, zda nedošlo ke škodám při přepravě a zapsat případná poškození obalu nebo zboží přímo do přepravního listu a DAIKINu tyto bez zbytečného odkladu, nejpozději však do následujícího pracovního dne, písemně oznámit. Případné škody vzniklé při přepravě, které nebyly zjevné při předání zboží, je zákazník povinen reklamovat u DAIKIN okamžitě, nejpozději však do 3 dnů po předání zboží zákazníkovi, v opačném případě nemá zákazník nárok na jakékoliv plnění ze strany DAIKIN. Není- li v konkrétním případě sjednáno DAIKINem se zákazníkem písemně jinak, pak v případě, že bude doprava (přeprava) zboží realizována na žádost zákazníka prostřednictvím dopravce zjednaného zákazníkem, podpis dodacího listu zboží přepravcem se pro účely převzetí zboží a splnění smlouvy ze strany DAIKIN považuje za podpis zákazníka. 4. Zákazník souhlasí, že v případě, že bude zboží DAIKINem přepravováno k zákazníkovi externím přepravcem zjednaným DAIKINem (zejména, ale nikoliv pouze, GEBRÜDER WEISS spol. s r.o.), bude se potvrzení přepravního listu tohoto přepravce ze strany zákazníka považovat za potvrzení převzetí zboží uvedeného na dodacím listu DAIKINu, na nějž přepravní list přepravce odkazuje, ze strany zákazníka, když tento dodací list DAIKINu doručí DAIKIN zákazníkovi vždy před dodáním zboží písemně a/nebo faxem a/nebo emailem. Číslo dodacího listu DAIKINu je uvedeno na přepravních listech přepravce GEBRÜDER WEISS spol. s r.o. 5. Dostane-li se zákazník do prodlení s převzetím zboží, je DAIKIN s výhradou ostatních práv oprávněn se zákazníkem objednaným zbožím nakládat dle vlastního uvážení (tj. např. prodat jej třetí osobě). V takovém případě počíná doručením písemného požadavku zákazníka na dodávku původně zákazníkem objednaného zboží běžet nová dodací lhůta v délce sjednané v původní smlouvě. 6. DAIKIN je v případě prodlení zákazníka s převzetím zboží rovněž oprávněn bez dalšího upozornění uskladnit zákazníkem objednané zboží ve svém skladu či na jiném místě na náklady zákazníka.
7.
DAIKIN je oprávněn účtovat zákazníkovi náklady vzniklé prodlením s převzetím zboží, zejména, ale nikoliv pouze, náklady na skladování (skladné 250,-Kč / 1 paleta zboží/1 týden), marné jízdy a dopravné dle tarifů k přepravě zboží použitého přepravce.
VIII. VÝHRADA VLASTNICTVÍ 1. Dodané zboží zůstává vlastnictvím DAIKINu až do úplného zaplacení ceny zboží zákazníkem. 2. Zákazník je povinen písemně upozornit každou třetí osobu, která by chtěla nakládat a/nebo nakládá se zbožím (a to jak v právním, tak i faktickém smyslu), k němuž má DAIKIN výhradu vlastnictví, že toto zboží je ve vlastnictví DAIKINu a zabránit třetí osobě v nakládání s takovým zbožím. 3. Zákazník není rovněž oprávněn se zbožím s výhradou vlastnictví DAIKIN nakládat jiným způsobem neslučitelným s výhradou vlastnictví DAIKIN (např.: zajišťovací převod vlastnického práva, zastavení zboží). 4. O zabavení nebo jiných omezeních zboží s výhradou vlastnictví DAIKINu je zákazník povinen DAIKIN bez zytečného odkladu, nejpozději však do následujícího pracovního dne, písemně vyrozumět. Jakékoliv související náklady hradí zákazník. 5. Uplatnění § 2133 občanského zákoníku se vylučuje. IX. ZÁRUKA A ODPOVĚDNOST A. Za vady příp. absenci garantovaných vlastností odpovídá DAIKIN s vyloučením dalších nároků, není-li v konkrétním případě se zákazníkem písemně dohodnuto jinak, takto: 1. Záruční doba činí – není-li dále uvedeno jinak - 36 měsíců ode dne dodání zboží. 2. Záruka je poskytována a zákazník má nárok na záruční plnění pouze za předpokladu, že zboží dodané DAIKINem zákazníkovi je instalováno a zároveň uvedeno do provozu přímo společností DAIKIN či osobou vyškolenou a písemně pověřenou k provádění těchto činností společností DAIKIN, a to v souladu s návodem DAIKIN, a zároveň je bez výjimky dodržován pravidelný servis a údržba zboží v souladu se servisními pokyny společnosti DAIKIN. U chladicích jednotek se spirálovými kompresory typu EWAQ-E/EWAQ-F a se šroubovými kompresory je, není-li dohodnuto jinak, zákazníkovi poskytována záruka v délce 12 měsíců, a to pouze v případě, když uvedení do provozu provádí společnost DAIKIN sama – v opačném případě není poskytována zákazníkovi žádná záruka. U produktů označených „J&E Hall International for Daikin“ je zákazníkovi poskytována záruka v délce 18 měsíců. U produktů označených „Rotex“ činí zákazníkovi poskytovaná záruka obecně 24 měsíců, avšak s následující výjimkami: na produkty Rotex HPSU je zákazníkovi poskytnuta materiálová záruka 24 měsíců od data uvedení do provozu, maximálně však 27 měsíců od data fakturace s tím, že v případě pravidelné údržby a servisu dle pokynů DAIKINu dostupných na domovské internetové stránce www.daikin.cz se poskytuje zákazníkovi prodloužená záruka 60 měsíců od uvedení do provozu, maximálně však 63 měsíců od data fakturace. Pravidla záruky uvedená v předchozí větě za dvojtečkou se aplikují rovněž na produkty označené jako Daikin Altherma, avšak u produktů označených jako Daikin Altherma Flex pouze tehdy, pokud toto zařízení uvede do provozu DAIKIN sama. Materiálovou zárukou se pro účely těchto Všeobecných obchodních podmínek rozumí: Dodávka originálních dílů Daikin přesně specifikovaných dle technických parametrů zařízení a spol. DAIKIN odsouhlasených. 3. V případě vad zboží, na něž se vztahuje záruka, se DAIKIN zavazuje, že vadné zboží příp. vadné díly podle volby DAIKIN vymění nebo opraví. Nároky na záruční plnění nad rámec těchto Všeobecných obchodních podmínek nebo jakékoli jiné nároky ze záruky neexistují. Pracovní doba, doba strávená na cestě nebo jiné náklady se nenahrazují. 4. Záruka a/nebo odpovědnost DAIKINu jsou vyloučeny, jestliže zákazník písemně neoznámí zjevné vady zboží do 3 pracovních dnů po dodání zboží, ostatní vady bez zbytečného odkladu po zjištění. 5. Záruka a/nebo odpovědnost DAIKIN je navíc k případům uvedeným v odst. 2. a 4. vyloučena zejména v případě vad zboží, které vznikly nevhodným nebo neodborným užíváním nebo zacházením se zbožím, nedodržováním provozních podmínek nebo servisních směrnic, nadměrným namáháním nebo nevhodnými provozními prostředky nebo nevhodnými výměnnými látkami. 6. K provedení veškerých nutných záručních zásahů musí být DAIKINu ze strany zákazníka poskytnut potřebný čas a součinnost. DAIKIN se zavazuje vyvinout veškeré úsilí, aby započal s odstraňováním vady zboží, za níž odpovídá, v co nejkratším termínu. Při dalším používání vadného zboží se záruka a/nebo odpovědnost DAIKINu vztahuje pouze na původní vadu. Náklady na odstranění vad zboží, provedené bez písemného předchozího souhlasu DAIKIN třetí osobou, se nenahrazují. Odpovědnost za následky takových odstraňování vad je ze strany DAIKINu vyloučena. 7. Záruční doba pro náhradní díly činí 6 měsíců od dodání. 8. Při odstranění vady nezačíná běžet záruční doba pro vyměněné nebo opravené díly znovu. 9. V případě, že je zákazník v prodlení s úhradou ceny zboží, není DAIKIN povinen odstranit zákazníkem uplatněné vady zboží, za něž DAIKIN odpovídá, a to až do okamžiku, dokud zákazník nesplní své platební závazky vůči DAIKINu. Zákazník není oprávněn, ani při oprávněných reklamacích, z tohoto důvodu pozastavit platbu ceny zboží či jiné splatné platby vůči DAIKINu. 10. Při dodání a montáži cizích výrobků se záruka omezuje na postoupení nároků na záruční plnění, které má DAIKIN vůči dodavatelům cizího výrobku. Další nároky zákazníka na záruční plnění, zejména na snížení ceny, jsou vyloučeny. 11. V případě vyřešení uplatněné reklamace (ať již z titulu vad zboží při předání či z titulu vad zboží, za něž DAIKIN odpovídá ze záruky) výměnou zboží či jeho části vyměněné zboží či jeho část přechází do vlastnictví DAIKIN, a to na základě výlučného uvážení a rozhodnutí DAIKINu. 12. Jakékoliv reklamace či nároky z titulu vad krytých zárukou je zákazník povinen uplatnit u DAIKINu písemně. B. Na náhradu újmy se uplatní obecné právní předpisy s tím, že právo zákazníka na náhradu újmy, resp. výše náhrady újmy ze strany DAIKINu se omezuje maximální částkou rovnající se kupní ceně zboží, s jehož dodáním DAIKINem zákazníkovi předmětná újma souvisí (v důsledku jehož dodání DAIKINem zákazníkovi újma vznikla). Omezení uvedené v předchozí větě se nevztahuje na právo zákazníka na náhradu újmy způsobené DAIKINem v případech uvedených v ustanovení § 2898 občanského zákoníku. X. VRÁCENÍ ZBOŽÍ 1. Zákazník je oprávněn zboží vrátit a/nebo vyměnit pouze na základě předchozího písemného souhlasu DAIKINu, přičemž i v případě, že se DAIKIN dle svého výlučného uvážení rozhodne vratku zboží akceptovat, akceptuje vrácení zboží pouze v min. hodnotě 2 500 Kč bez DPH a max. hodnotě 1 250 000 Kč bez DPH za předpokladu, že toto zboží není poškozeno, nebylo použito, je zabaleno v originálních obalech a je v takových podmínkách umožňujících jeho další prodej. Zejména vrácení již nainstalovaného zboží (včetně chillerů) a speciálně vyrobených produktů (zboží) včetně náhradních dílů nebude v žádném případě ze strany ze strany DAIKINu akceptováno. 2. V případě, že si zákazník přeje vznést návrh na vrácení a/nebo výměnu zboží ve smyslu čl. X odst. 1 těchto Všeobecných obchodních podmínek, je povinen vyplnit formulář „Požadavek na vrácení zboží“, dostupný na www.daikin.cz a doručit jej (faxem nebo mailem) do DAIKINu na jím určenou adresu nejpozději do 10 dnů od dodání zboží. 3. Zákazník je v případě, že DAIKIN souhlasil s vrácením a/nebo výměnou zboží ve smyslu čl. X odst. 1 těchto Všeobecných obchodních podmínek, povinen doručit zboží na své nebezpečí a náklady do místa určeného DAIKINem. 4. V každém případě vrácení a/nebo výměny zboží bude zákazníkovi dobropisováno maximálně 80% ceny bez DPH, za níž DAIKIN toto zboží prodal zákazníkovi. Všechny standardní vratky budou předmětem poplatků za přeskladnění / administrativních poplatků ve výši 20% z ceny dotčeného zboží bez DPH. 5. Všechny vratky zboží DAIKIN prověří. Jestliže zboží není vráceno v souladu s těmito Všeobecnými obchodními podmínkami (viz. čl. X odst. 1 - 4 těchto Všeobecných obchodních podmínek), je DAIKIN oprávněn bez dalšího odmítnout vratku zboží a vrátit zboží zpět zákazníkovi na náklady a nebezpečí zákazníka. Alternativně k uvedenému v předchozí větě je DAIKIN oprávněn účtovat zákazníkovi vyšší náklady na přeskladnění zboží / admininstrativní poplatky než je 20% z ceny dotčeného zboží bez DPH uvedených v čl. X odst. 4 těchto Všeobecných obchodních podmínek. 6. Jakýkoliv DAIKINem vystavený dobropis, resp. pohledávka zákazníka za DAIKINem z takto vystaveného dobropisu, bude vždy započtena oproti pohledávkám DAIKINu za zákazníkem, které vzniknou z budoucích dodávek zboží DAIKINem zákazníkovi, a tedy žádná jiná forma úhrady pohledávky zákazníka za DAIKINem z vystaveného dobropisu není přípustná, nestanoví-li DAIKIN v konkrétním případě jinak. XI. SOUDNÍ PŘÍSLUŠNOST, ROZHODNÉ PRÁVO 1. Veškeré spory, které vzniknou mezi DAIKINem a zákazníkem budou řešeny obecným soudem s místní příslušností dle sídla DAIKIN. 2. Veškeré smluvní vztahy jakož i veškeré spory vzniklé v souvislosti s těmito smluvními vztahy se řídí českým právem s vyloučením jeho kolizních norem. Úmluva OSN o smlouvách o mezinárodní koupi zboží se nepoužije. 3. Práva a povinnosti DAIKINu a zákazníka, která nejsou výslovně upraveny příslušnou smlouvou či těmito Všeobecnými obchodními podmínkami, se řídí občanským zákoníkem a ostatními právními předpisy v mezích jejich působnosti. XII. SALVÁTORSKÁ KLAUZULE 1. V případě neplatnosti nebo neúčinnosti jednotlivých ustanovení těchto Všeobecných obchodních podmínek nebo smlouvy, uzavřené mezi DAIKINem a zákazníkem, zůstává platnost a účinnost zbývajících ustanovení nedotčena. Neplatná či neúčinná ustanovení budou nahrazena takovými přípustnými ustanoveními, která jsou sjednané vůli stran nejblíže. XIII. OSTATNÍ 1. Zákazník je oprávněn postoupit jakékoliv pohledávky za DAIKINem na třetí osobu pouze s předchozím písemným souhlasem DAIKINu. 2. DAIKIN je oprávněn kdykoliv postoupit smlouvu na dodávku zboží se zákazníkem nebo všechna či pouze některá svá práva a povinnosti z této smlouvy na jiný subjekt, s čímž zákazník uzavřením předmětné smlouvy s DAIKINem souhlasí. 3. Informace poskytnuté DAIKINem zákazníkovi v souvislosti se smlouvou a objednávkami se považují za důvěrné. 4. Zákazník se zavazuje, že neporuší obchodní tajemství DAIKINu, o kterém se dozví v souvislosti s obchodním vztahem. Zároveň se zavazuje, že zajistí dodržování obchodního tajemství DAIKINu i obchodními partnery zákazníka. 5. Veškerá práva DAIKINu plynoucí z uzavřených smluv se promlčují v promlčecí lhůtě v trvání 10 let ode dne, kdy právo mohlo být uplatněno poprvé. 6. Zákazník na sebe ve smyslu ustanovení § 1765 odst. 2 občanského zákoníku přebírá nebezpečí změny okolností. 7. Tyto Všeobecné obchodní podmínky nabývají platnosti a účinnosti dnem 1. ledna 2014, ruší bez dalšího Všeobecné obchodní podmínky DAIKIN ze dne 1. 4. 2013, a jejich platnost a účinnost není časově omezená. DAIKIN AIRCONDITIONING CENTRAL EUROPE – CZECH REPUBLIC spol. s r.o.
Obchodní podmínky společnosti Daikin jsou k dispozici také na internetu na webových stránkách www.daikin.cz.
DAIKIN AIRCONDITIONING CENTRAL EUROPE - CZECH REPUBLIC SPOL. S R. O.
Pobřežní 3, 186 00 Praha 8, Česká republika Tel.: +420 221 715 700, Fax: +420 221 715 701, Email:
[email protected], Web: www.daikin.cz Applied Systems Price list 2015-2016
35
Fact: R-22 has been banned in Europe* If your equipment is more than 15 years old, it probably still uses R-22 refrigerant. After 31st December 2014 repairs to R-22 systems will be prohibited, possibly resulting in unexpected downtime. Keep your business running at all times with Daikin replacement technology.
Controller box upgrade
- Softstarter - Inverter
Compressor upgrade
* EU directive: Regulation (EC) No.2037/2000
DAIKIN AIRCONDITIONING CENTRAL EUROPE – CZECH REPUBLIC spol. s r.o. budova IBC – Pobřežní 3, CZ – 186 00 Praha 8 · Tel.: +420 221 715 700, Fax: +420 221 715 701 · e-mail:
[email protected] · www.daikin.cz Daikin products are distributed by:
The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V. / Daikin Central Europe HandelsGmbH. Daikin Europe N.V. / Daikin Central Europe HandelsGmbH have compiled the content of this publication to the best of their knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. / Daikin Central Europe HandelsGmbH explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this publication. All content is copyrighted by Daikin Europe N.V. DACE Applied Systems Pricelist 2015-2016 Vyhrazujeme si právo na tiskové chyby a změny modelů.