Příloha č. 4 k č. j.: MV-126289-9/VZ-2014
Technická specifikace veřejné zakázky
Modernizace komunikační optické páteře Ministerstva vnitra v Praze Obsah 1 Technické řešení ......................................................................................................................................................... 1 1.1 Cíle ........................................................................................................................................................................... 1 1.2 Popis výchozího stavu ..................................................................................................................................... 2
1.3 Požadované řešení............................................................................................................................................ 2
2 Funkční specifikace ................................................................................................................................................... 3 2.1 MPLS PE směrovače ......................................................................................................................................... 3 2.1.1 Požadavky na MPLS směrovač .............................................................................................................. 4
2.2 Měřící souprava pro měření fyzických parametrů optických kabelů a parametrů 1G a 10G ethernetu ..................................................................................................................................................... 6
3 Požadované počty komponent infrastruktury ............................................................................................... 8
4 Rámcová specifikace komponent a služeb....................................................................................................... 9 4.1. HW/SW požadavky na předmět plnění ................................................................................................... 9 4.1.1.HW/SW požadavky na Páteřní MPLS směrovač ............................................................................ 9
4.1.2.Požadavky na Měřící soupravu .......................................................................................................... 13
4.2. Služba instalace............................................................................................................................................... 14
4.3. Služba školení .................................................................................................................................................. 14
5 Místa plnění ............................................................................................................................................................... 14 6 Další podmínky plnění .......................................................................................................................................... 17
1 Technické řešení 1.1 Cíle Cílem je doplnit modernizovanou komunikační infrastrukturu MV v Praze MPLS směrovači a pomocnou technologií. Komunikační infrastruktura musí být konvergovaná, vysoce spolehlivá a s perspektivou využitelnosti minimálně 10 let.
Modernizace musí zajistit vysoce kapacitní transportní síť mezi uzlovými objekty Ministerstva vnitra, Policejního prezídia a Policie na území hl.m. Prahy. Modernizace musí splnit níže uvedené dílčí cíle: •
1
Zvýšení datové propustnosti sítě pro jednotlivé objekty MV a PČR.
• • • • • •
Zvýšení spolehlivosti a dostupnosti komunikační infrastruktury v rámci objektů MV a PČR. Zajištění podpory nejmodernějších komunikačních technologií.
Zefektivnění činností uživatelů zkrácením odezvy jednotlivých aplikací. Zjednodušení správy a monitoringu komunikační infrastruktury.
Rychlejší detekce a odstraňování případných poruch.
Zabezpečení plnění Pokynu vlády ČR č.727 ze dne 8.6.2009 o podpoře protokolu IPv6.
1.2 Popis výchozího stavu
Topologie komunikační infrastruktury MV a PČR Uzly Olšanská, Wintrova, Centrotex, Kongresová, Bartolomějská, Strojnická a Letná tvoří novou větev pražské optické sítě ITS MV. Uzly budou v rámci jiné akce osazeny DWDM multiplexory a propojeny optickými propoji v kruhové topologii.
Uzly jsou připojeny do MPLS páteřní sítě, a to nezálohovaně (většinou jedním páteřním směrovačem), což zvyšuje riziko výpadku komunikační podpory jak z hlediska uživatelů dislokovaných v daném objektu, tak i na rozhraní styku s veřejností z hlediska přístupu k centrálním informačním systémům.
1.3 Požadované řešení
V objektech uvedených v kapitole Místa plnění (Olšanská, Wintrova, Centrotex, Kongresová, Bartolomějská, Strojnická, Letná) se požaduje osazení a zprovoznění vždy dvojice páteřních směrovačů MPLS PE. Schéma zapojení směrovačů v pražské páteřní síti
Páteřní síť Praha MV a PČR
Olšanská
Centrotex
Kongresov á
Bartolomějská
Strojnická Wintrov a
Páteřní směrov ače objektu
Páteřní směrov ače objektu DWDM páteřní okruh Praha
2
Letná
2 Funkční specifikace 2.1 MPLS PE směrovače V rámci zvýšení spolehlivosti a dostupnosti páteřní IP/MPLS infrastruktury je požadováno vybavit uzly uvedené v kapitole Místa plnění dvěma MPLS PE směrovači. Zdvojení PE směrovačů bude znamenat významné posílení spolehlivosti páteřní části IP/MPLS infrastruktury, obě zařízení v jednom uzlu připojené ze dvou nezávislých směrů budou plně zálohovat svoji funkci. Z důvodu dosažení maximální kompatibility a minimalizování nároků na správu, konfigurace a monitoring sítě je požadováno, aby směrovače bylo možné integrovat pod stávající systém dohledu HP NNM.
Kruhová topologie páteřní sítě umožňuje nastavení služeb mezi libovolnými uzly kruhu. Služby požadované zprovoznit na MPLS PE směrovačích při výstavbě jsou následující: 1.
Praha Olšanská – Praha Centrotex
2.
Praha Centrotex – Praha Kongresová
3.
Praha Kongresová – Praha Bartolomějská
4.
Praha Bartolomějská – Praha Strojnická
5.
Praha Strojnická – Praha Letná
6.
Praha Letná - Wintrova
7.
Praha Olšanská - Wintrova
► 1x ethernet 10Gbps
► 12x ethernet 1Gbps ► 1x ethernet 10Gbps
► 12x ethernet 1Gbps ► 1x ethernet 10Gbps
► 12x ethernet 1Gbps ► 1x ethernet 10Gbps
► 12x ethernet 1Gbps ► 1x ethernet 10Gbps
► 12x ethernet 1Gbps ► 1x ethernet 10Gbps
► 12x ethernet 1Gbps ► 1x ethernet 10Gbps
► 12x ethernet 1Gbps
3
Blokové schéma zapojení páteřních směrovačů v pražské páteřní síti
2.1.1 Požadavky na MPLS směrovač Směrovače musí mít modulární architekturu s možností přidávat moduly rozhraní dle budoucí potřeby. Směrovače musí zajistit plnou podporu IP adresace a směrovacích protokolů pro IPv4 a IPv6 s minimálními požadavky na směrovací protokoly OSPFv2/v3, BGPv4 a Multiprotocol BGP.
Směrovač musí plně podporovat řízení kvality služeb (QoS – Quality of Service) s možností definice frontování, klasifikace provozu, markování provozu (DSCP-Differentiated Services Code Point, COS-Class of Service) s možností omezení a vyčlenění šířky pásma provozu v jednotlivých kategoriích a definici prioritní fronty pro provoz IP telefonie. Směrovače musí mít plnou podporu IPv6 služeb jako jsou DNS (Domain Name System), Telnet/SSH (Secure Shell), DHCP (Dynamic Host Configuration Protocol), Multicast a QoS. Směrovače musí podporovat technologii DualStack (IPv4 a IPv6).Směrovač musí být vysoce škálovatelný a podporovat rozhraní 1GE, 10GE a 40GE.
Směrovač musí zajistit základní bezpečnostní funkce. Základem je ochrana směrovače proti DoS (Denial of Service) útokům tzv. CPP (Control Plane Policing), která umožňuje konfiguraci QoS pro jednotlivé typy provozu, chrání ho před nadměrným zatížením a tím možného narušení funkce směrovače.
Směrovače musí mít možnost vyhrazených portů pro management a to jak po Ethernetu, tak rozhraní sériové komunikace (RS-232) na každé řídící logice zvlášť. Jde o použití vyhrazených Ethernetových portů pro management směrovačů mimo provozní sít, tzv. OOB (Out of Band) Management. 4
Souhrn požadovaných technických parametrů IP/MPLS vrstvy Neblokující architektura přepínacího/směrovacího subsystému (wire speed) min. 100 Gbps Distribuovaná architektura směrovaní (oddělený Control Plane a Data Plane)
Směrovače musí provádět směrování IPv4 i IPv6 v hardware a to jak směrových tak více směrových vysílání. Shaping, Policing bez snížení propustnosti směrovače Podpora rozhraní: o
o
o
1GE
10GE
40 GE
Replikace více směrových paketů v hardware
Plná podpora MPLS (VPLS [BGP, LDP], L2VPN [LDP, RSVP], L3VPN, Inter AS VPN)
Podpora monitorování IP (IPv4 a IPv6) datových toků formou exportu provozních informací o přenesených datech v pseudoreálném čase minimálně: zdrojová/cílová IP, zdrojový/cílový TCP/UDP port/protokol - NetFlow/IPFix nebo ekvivalent. Kontrola zdrojové IPv4, IPv6 adresy na fyzických i logických L3 rozhraních podle aktuální směrovací tabulky (antispoofingová kontrola ekvivalentní funkci uRPF (Unicast Reverse Path Forwarding)
Podpora bezstavových filtrů na rozhraních v hardware bez vlivu na výkon směrování, přepínaní
Vyhodnocení podle L2/L3/L4 parametrů aplikovatelná na úrovni L2/L3 fyzického i logického rozhraní Podpora Jumbo Frame s payloadem (obsahem) minimálně 9 Kilobyte
Podpora Ethernet 802.3ah OAM (minimálně Neighbor Discovery, Link Monitoring, Remote Fault Indication) Podpora Ethernet 802.1ag CFM
Možnost výměny komponent (hot-swap) bez ovlivnění funkce zařízení
Hardwarová podpora zajištění kvality služby (QoS) podle L2/L3/L4 atributů umožňující implementaci QoS podle modelu rozlišovaných služeb (DiffServ dle RFC 2474, 2475, 2597, 2598, 2697, 3270): o o
Klasifikace a re klasifikace rámců/paketů na vstupu i výstupu (IEEE 802.1p, IP DSCP, IP Precedence, EXP MPLS) Omezování provozu (policing) na vstupu i výstupu (kompatibilita s RFC 2697 a/nebo RFC 2698), alespoň 8 výstupních front (jedna s absolutní prioritou) na každém rozhraní, konfigurovatelné mechanismy preventivní ochrany proti zahlcení
Podpora MPLS
MPLS Forwarding
MPLS Load Balancing MPLS Fast Reroute
MPLS Traffic Engineering 5
VPLS
Měření vstupního a výstupního optického výkonu tzv. Tx and Rx optical power monitoring (DOM) na optických portech
2.2 Měřící souprava pro měření fyzických parametrů optických kabelů a parametrů 1G a 10G ethernetu V souladu s požadavkem vysoké spolehlivosti páteřní sítě požadujeme v objektech Olšanská a Wintrova dodat měřící soupravu na měření optických kabelů a parametrů 1G a 10G ethernetu. Základní požadované parametry :
1. Měření fyzických parametrů optických kabelů a. Vlnové délky: SM 1310 nm, 1550 nm, 1625 nm; MM 850 nm b. Dynamický rozsah: 37dB (1310nm), 35 dB (1550nm) c. Mrtvé zóny: 0,9m (EDZ), 4m (ADZ) d. Počet bodů: 256 000 e. Konektor: SC/APC f. Předřadné vlákno 1000m g. Možnost vyhodnocení a následného zobrazení OTDR průběhu pomocí ikon přehledně zobrazujících a popisujících jednotlivé detekované události h. Možnost přepínání mezi OTDR průběhem a zobrazením trasy pomocí ikon 2. Testování parametrů 1G a 10G ethernetu a. VLAN, Q-in-Q, možnost zapouzdření až 8 VLAN b. VPLS/MPLS, MPLS-TP c. IPv4/IPv6 d. L4 TCP dle RFC6349 do rychlosti 1000Mbps / 1GE (detekce MTU, zpoždění round-trip, test Walk-the-Window, TCP propustnost, až 64 relací současně) e. RFC2544 (symetricky/asymetricky, propustnost, ztráta rámců, zpoždění, back– to-back test, paketový jitter) f. Y.1564 (CIR, EIR, MIR, CBS, zpoždění, ztrátovost rámců FLR) g. Filtrování provozu dle MAC zdrojové nebo cílové adresy, VLAN ID, VLAN priority, IP zdrojové nebo cílové adresy, masky podsítě h. VoIP na 10/100/1000 Mbps a 10GE rozhraní, protokoly SIP a H.323 i. IPTV na 10/100/1000 Mbps a 10GE rozhraní, detekce až 512 SPTS nebo 32 MPTS a analýza až 16 SPTP nebo 1 MPTS; měření ztrátovosti rámců, paketový a PCR jitter 3. Testování a monitorování vzdálených lokalit pomocí vzdáleného smyčkovacího zařízení na 1G ethernetu pro všechny lokality (14 zařízení) a. Podpora IPv4/IPv6, VLAN b. Vzdálené řízení přes IP
Požadované vlastnosti měřící soupravy :
6
1. Fyzické vlastnosti: a. Kompaktní přenosný přístroj b. Barevná dotyková obrazovka min. 7“ c. Musí obsahovat USB a RJ45 Ethernet pro přenos reportů a nastavení d. Provoz na baterie min. 4 hodiny
2.
3.
7
Testovací rozhraní pro ethernet: a. 10/100/1000 Mbps elektrické RJ45 (dva porty) b. 100 Mbps optické 850nm (dva porty) c. 1 Gigabit optické 850nm, 1310nm, 1550nm, 1625nm (dva porty) d. 10 GE LAN (jeden port)
Souprava musí obsahovat modul pro inspekci optických konektorů : a. Digitální mikroskop, zvětšení 200/400x b. Pass/Fail analýza dle IEC 61300-3-35 c. Možnost připojení pomocí USB k přístroji, PC nebo zařízení Android d. Adaptéry panelové konektory SC/PC, LC/PC, patchcordy 1,25mm a 2,5mm
PRAHA 6 Bubenečská 20
PRAHA 7 Strojnická
PRAHA 3 Olšanská 4
PRAHA 7 - Letná
1
Páteřní MPLS směrovač
2
2
2
2
2
2
2
3
Technologický stojan 19“
1
0
0
0
0
0
0
2
Měřící souprava UPS
Monitoring stojanu Montážní materiál
8
PRAHA 4 Kongresová
Popis
Požadovaný počet
PRAHA 4 Centrotex
Kategorie
PRAHA 1 Bartolomějská 4
3 Požadované počty komponent infrastruktury
0 1 1 1
0 1 2 1
0 0 1 1
0 2 1 1
0 2 1 1
1 1 4 1
1 4 2 1
4 Rámcová specifikace komponent a služeb 4.1. HW/SW požadavky na předmět plnění 4.1.1. HW/SW požadavky na Páteřní MPLS směrovač Č.
Požadavek Hardware
1 2 3 4 5 6 7 8 9
10 11
Neblokující architektura přepínacího/směrovacího subsystému (wire speed) min.100 Gbps Velikost maximálně 2RU
Minimálně 4 porty 10GE (SFP+/XFP/X2) Minimálně 12 portů 1GE SFP
Možnost rozšířit počet 10 GE portů až na 8 např. formou doplnění modulu
Možnost výměny napájecích zdrojů za provozu (hot-swap) bez ovlivnění funkce zařízení jako celku Redundantní AC (230V) napájení (zařízení musí být schopno plné funkce při poruše jednoho napájecího zdroje). Možnost výměny ventilátorů za provozu (hot-swap) bez ovlivnění funkce zařízení jako celku (N+1) Podpora výměných DWDM modulů (dosah až 80km)
Podpora laditelných 10 GE DWDM modulů s 50 GHz rozestupem signálů s podporou OTN/FEC Možnost logického spojení 2 směrovačů do jedné logické konfigurace Management
12
management LAN port (out-of-band management)
14
Management protokoly
13 15 16 17 18 19 20
console port
auxiliery port SSH v1 a v2
SNMP všechny verze Telnet
TFTP (Bootstrap) HTTP
HTTPS
Monitoring
21
syslog
23
Radius
25
NTP
22 24
26 27
9
sFlow nebo NetFlow/IPFIX AAA Služby TACACS+
Síťové služby Ethernet služby Minimálně 500k MAC adres na systém Multi Chassis LAG
28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70
10
IEEE 802.1Q IPv4 IPv6
Minimálně IPv4 2 mil. route ve FIB Minimálně IPv6 1 mil. route ve FIB L2VPN L3VPN
IPoDWDM
RFC 768 UDP RFC 791 IP
RFC 792 ICMP RFC 793 TCP
RFC 826 ARP
RFC 894 IP over Ethernet RFC 903 RARP
IPv6 v HW - bez impactu
Equal Cost Multi-Path (ECMP) Support
RFC 1256 IPv4 ICMP Router Discovery (IRDP)
RFC 1519 Classless Interdomain Routing (CIDR) CSPF: Constrained Shortest Path First BGP: Multi-path support
BGP: MD5 Authentication BGP: Multihop ebgp BGP: Peer groups
BGP: Route Dampening BGP: Next hop tracking BGP: VRF Max prefix
BGP: Route Reflection
BGP: Multi-protocol (MP-BGP)
BGP: Multi-AS L3 VPN - option All BGP: Confederation
BGP: Incremental Update
BGP: BGP Route Summarisation BGP: MTU path discovery
BGP: Multiprotocol extensions to transport IPv6 information via Network Layer Reachability Information (NLRI) packets BGP: 4-byte ASN Number BGP: Flowspec
IS-IS: Route Summarisation
IS-IS: Multi-topology (IPv4 and IPv6 in a single instance) IS-IS: IPv6
IS-IS: MD5 Authentication
IS-IS: TE Support (RFC 3784) IS-IS: Overload
71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99
IS-IS: Sync LDP-IGP IS-IS: FRR
IS-IS: Forwarding Adjacency IS-IS: Auto route
VRRP: Fast Advertisement VRRP: Delay/Holdover VRRP: Timers
VRRP: Authentication
VRRP: Priority and Pre-empt VRRP: VPN Support
RSVP: Authentication
RSVP: MD5 Authentication
RSVP: Call Admission Control (CAC) OSPF V2 (IPV4) OSPF V3 (IPv6) OSPF: FRR
OSPF: MD5 Authentication OSPF: Sham Links LFA
Multicast features Static RP IPv6
IPv4/IPv6 Dual Stack
IP Multicast – IGMP V2 and V3
IP Multicast – IGMP Access Lists
IP Multicast – IGMP Group Limiting (with a quota) IP Multicast – IGMP Snooping IP Multicast – PIM Snooping
IP Multicast – IGMP v2 to v3 SSM mapping Statically mapping v2 reports to SSM multicast source/groups IP Multicast – PIM Version 2 (SM, DM, SDM)
100 IP Multicast – Multicast Source Discovery Protocol (MSDP) 101 IP Multicast – PIMv2 Source Specific Multicast (SSM)
102 IP Multicast – PIMv2 Source Specific Multicast (SSM) Mapping 103 IP Multicast – Multicast Routing over SVI 104 IP Multicast – PIMv2 for mVPNv4 105 MPLS
106 LDP / RSVP signalizace
107 RSVP-TE (FRR, Link/node protection) 108 L2VPN
109 VPLS LDP based
110 VPLS BGP based
111 L3VPN (RFC 2547, 4364)
112 Mcast in L3VPN – draft Rossen
11
113 Auto route 114 MPLS-TE FRR (MPLS local restoration/local protection) 115 Path protection 116 Link protection
117 Node protection 118 BFD Trigger FRR 119 RSVP-TE 120 Directed LDP
121 MPLS-TE – OSPF-TE (RFC 3630) 122 MPLS-TE – Other IGP-TE Extensions
123 MPLS-TE – Explicit Routing (ER) 124 MPLS-TE – Constraint Based Routing (CBR)
125 MPLS-TE – Dynamic Routing 126 MPLS-TE – FRR failover time for link protection
127 MPLS-TE – FRR failover time for node protection 128 MPLS-TE – FRR failover time for path protection
129 MPLS-TE – FRR facility backup or limited to one-to-one backup 130 MPLS-TE – FRR Make-before-Break (MBB) functionality 131 MPLS-TE: Counters ACL+Security
132 Secure interface login and password
133 Ingress and Egress ACLs: allow and deny, Port ACLs, VLAN ACLs, Routed ACLs 134 Static ARP support
135 Control Plane denial-of-service (DoS) protection 136 Prideleni uzivatele k roli 137 Traffic Storm Control
138 Control Plane Policing
Quality of service (QoS)
139 Layer 3 QoS
140 Ingresspolicing: 2rate3color - Egresspolicer,policermarkdownaction 141 Egressshaping:per-queue,per-port
142 Podpora HQoS na všech osmi 10 GE portech 143 HQoS minimálně 8 front per VLAN
144 Strict priority queuing (LLQ), WRED, Weighted Tail Drop 145 802.1p remarking
146 Congestion avoidance capabilities: WRED 147 Trust IEEE 802.1p/DSCP (ingress) Enviroment
148 EN 55022 Class A (2006)+ A1 2007 European Radiated Emissions
12
4.1.2. Požadavky na Měřící soupravu Č. 1 2 3 4 5 6 7 8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
13
Požadavek
Měření fyzických parametrů optických kabelů Vlnové délky: SM 1310 nm, 1550 nm, 1625 nm; MM 850 nm Dynamický rozsah: 37dB (1310nm), 35 dB (1550nm) Mrtvé zóny: 0,9m (EDZ), 4m (ADZ) Počet bodů: 256 000 Konektor: SC/APC Předřadné vlákno 1000m Možnost vyhodnocení a následného zobrazení OTDR průběhu pomocí ikon přehledně zobrazujících a popisujících jednotlivé detekované události Možnost přepínání mezi OTDR průběhem a zobrazením trasy pomocí ikon Testování parametrů 1G a 10G ethernetu VLAN, Q-in-Q, možnost zapouzdření až 8 VLAN VPLS/MPLS, MPLS-TP IPv4/IPv6 L4 TCP dle RFC6349 do rychlosti 1000Mbps / 1GE (detekce MTU, zpoždění round-trip, test Walk-theWindow, TCP propustnost, až 64 relací současně) RFC2544 (symetricky/asymetricky, propustnost, ztráta rámců, zpoždění, back–to-back test, paketový jitter) Y.1564 (CIR, EIR, MIR, CBS, zpoždění, ztrátovost rámců FLR) Filtrování provozu dle MAC zdrojové nebo cílové adresy, VLAN ID, VLAN priority, IP zdrojové nebo cílové adresy, masky podsítě VoIP na 10/100/1000 Mbps a 10GE rozhraní, protokoly SIP a H.323 IPTV na 10/100/1000 Mbps a 10GE rozhraní, detekce až 512 SPTS nebo 32 MPTS a analýza až 16 SPTP nebo 1 MPTS; měření ztrátovosti rámců, paketový a PCR jitter Fyzické vlastnosti: Kompaktní přenosný přístroj Barevná dotyková obrazovka min. 7“ Obsahuje USB a RJ45 Ethernet pro přenos reportů a nastavení Provoz na baterie min. 4 hodiny Testovací rozhraní pro ethernet: 10/100/1000 Mbps elektrické RJ45 (dva porty) 100 Mbps optické 850nm (dva porty) 1 Gigabit optické 850nm, 1310nm, 1550nm, 1625nm (dva porty) 10 GE LAN (jeden port) Modul pro inspekci optických konektorů : Digitální mikroskop, zvětšení 200/400x Pass/Fail analýza dle IEC 61300-3-35 Možnost připojení pomocí USB k přístroji, PC nebo zařízení Android Adaptéry panelové konektory SC/PC, LC/PC, patchcordy 1,25mm a 2,5 Vzdálené smyčkovací zařízení pro testování a monitorování vzdálených lokalit na 1G ethernetu Testování a monitorování vzdálených lokalit pomocí vzdáleného smyčkovacího zařízení na 1G ethernetu současně pro všechny MPLS směrovače (14 smyček) Podpora IPv4/IPv6, VLAN Vzdálené řízení přes IP
4.2. Služba instalace č. 1 2
3 4
Požadavek Zhotovitel dopraví dodávku v rámci míst plnění na místo určené Objednatelem. Veškeré náklady související s dopravou a instalací jdou na vrub Zhotovitele. Montáž – kompletace a smontování dodávky včetně namontování do racku a zapojení, a to odborným způsobem je součástí dodávky. Za součást instalace je považována také konfigurace a zprovoznění dodávky v plném rozsahu včetně připojení a součinnost při konfiguraci sítě (zejména připojení k SW pro management a monitoring). Dále pak otestování požadovaných funkcionalit. Objednatel se zavazuje zajistit plnou součinnost kvalifikovaných pracovníků provozního oddělení při instalaci dodávky a přístup do lokalit určených pro instalaci. Technici Zhotovitele splňují veškeré podmínky dané výrobcem dodávaného zařízení pro jeho instalaci a oživení.
4.3. Služba školení č. 1
2 3
Požadavek Součástí dodávky je i zajištění školení ICT specialistů na dodávanou technologii, které proběhne v prostorách Zhotovitele. Konkrétní termíny a místo školení bude určené Zhotovitelem. Školení proběhne v českém nebo slovenském jazyce.Školení poskytne účastníkům komplexní informace v takovém rozsahu, aby tito pracovníci dokázali samostatně a dlouhodobě provozovat dodané řešení. Školitel pověřený Zhotovitelem bude disponovat certifikací výrobce dodávané technologie, resp. výrobců všech technologií, ze kterých bude složena dodávka (pokud výrobci takové certifikace vystavují) a bude mít praxi v oboru minimálně 5 let. Základní školení – 1 termín pro maximálně 8 lidí se zaměřením na seznámení s produktem, jeho instalací, konfigurací a uvedením do provozu určené pro konfiguraci, provoz a údržbu sítě.
5 Místa plnění Místy plnění jsou objekty zadavatele: 1. Olšanská 4, Praha 3 - objekt MV
2. Kongresová 1666/2, Praha 4 – objekt KŘ Policie hl.m. Praha 3. Nad Štolou 3, Letná, Praha 7 – objekt MV
4. Centrotex – nám. Hrdinů 1634/3, Praha 4 – objekt MV 5. Strojnická 27, Praha 7 – objekt PP ČR
6. Bubenečská 20, Praha 6 – objekt PP ČR (též „Wintrova“)
7. Bartolomějská 7, Praha 1 – objekt KŘ Policie hl.m. Praha Požadavek na další vybavení jednotlivých míst plnění:
Olšanská
14
Technologii se požaduje instalovat do volného prostoru ve čtyřech stávajících stojanech. Dva stojany mají rozměry 42U, 80x80 cm a dva stojany 42U, 80x100 cm . Do každého stojanu je požadováno dále dodat a nainstalovat: monitoring stojanu (teplota, vlhkost, otevření dveří), 2x boční třmen pro vedení kabelů, 2x horizontální kabelová instalační lišta, 2x napájecí panel se zásuvkami min. 12x UTE, 6x C13. Do tří stojanů je požadováno dodat ventilační jednotku (min. 2x ventilátor) řízenou termostatem, v posledním stojanu je stávající. Stojany včetně vybavení je požadováno uzemnit. Pro napájení technologie se požaduje dodat 1x UPS 80 kW včetně instalace a zprovoznění. Dodávaná zařízení je požadováno připojit vždy na
č. 1
dvě větve napájení. Jedna větev bude přivedena z dodané UPS, druhá větev bude přivedena ze střídače stávajícího napaječe. Kabelová vzdálenost je cca 15 m.
Požadované parametry UPS: Požadavek
Výstupní výkon min. 80 kW s možností rozšíření na min. 120 kW
2
Vstupní jmenovité napětí 3x 400V/230 V AC,
3
Stabilita vstupního napětí ±20%
4
Vstupní kmitočet 40-70 Hz
5
Korekce vstupního účiníku
6
Výstupní napětí 230 V AC
7
Stabilita výstupního napětí statická < ± 1 %, dynamická < ± 4 %
8
Zkreslení výstupního napětí při zatížení lineárním < ± 3 %, nelineárním < ± 5 %
9
Nastavení regulace výstupního napětí
10
Výstupní kmitočet 50 Hz
11
Tolerance výstupního kmitočtu < ± 4 % (±2 Hz)
12
Možnost asymetrického zatížení fází
13
Modulární konstrukce
14
Zálohování v režimu n+1
15
Doba zálohování pro uvedený výstupní výkon min. 5 minut
16
Výměna modulů elektroniky za provozu
17
Typ baterií bezúdržbový
18
Teplotní regulace nabíjení baterií
19
Test baterií automatický a periodický (nastavitelný) a manuální z ovládacího panelu
20
Výměna baterií za chodu (hot swap)
21
Komunikační modul/karta pro SNMP a HTTP management
22
Modul pro monitorování prostředí (teplota, vlhkost, otevření/zavření stojanu)
23
Elektronický bypass
24
Výstup na rozvodnice (z jednotky bude napájena řada stojanů)
Kongresová
Technologii se požaduje instalovat do volného prostoru ve stávajícím stojanu o rozměrech 42U, 80x100 cm. Do stojanu je požadováno dále dodat a nainstalovat: monitoring stojanu (teplota, vlhkost, otevření dveří), 2x boční třmen pro vedení kabelů, 2x horizontální kabelová instalační lišta. Stojan včetně vybavení je požadováno uzemnit. Dodávaná zařízení budou napájena ze stávajících napájecích panelů ve stojanu.
Letná
15
Technologii se požaduje instalovat do volného prostoru ve stávající stojanu. Stávající zařízení v tomto stojanu je požadováno přeuspořádat. Stojan má rozměry 42U, 60x60 cm. Do stojanu je požadováno dále dodat a nainstalovat: monitoring stojanu (teplota, vlhkost, otevření dveří), 2x horizontální kabelová instalační lišta, 2x napájecí panel se zásuvkami min 6x UTE. Pro napájení technologie se požaduje dodat 2x UPS 2200 W včetně instalace a zprovoznění. Požadované parametry UPS: montáž do 19“ stojanu, SNMP/HTTP
management, automatický bypass, min. počet zásuvek 6x C13. Do stojanu je požadováno přivést dvě větve silového rozvodu jištěné 16A jističi. Jističe je požadováno instalovat do podružného rozvaděče v sousední místnosti, kabelová vzdálenost je cca 18 m. Do tohoto podružného rozvaděče je požadováno dovést silové napájení od silového rozvaděče na chodbě, kabelová vzdálenost je cca 30 m. Silové rozvody je požadováno přivést do dodávaných napájecích panelů, odkud budou napájeny UPS. Dodávaná zařízení je požadováno připojit na napájení na UPS, a to redundantní zdroje vždy na rozdílnou UPS.
Centrotex
Technologii se požaduje instalovat do volného prostoru ve dvou stávajících stojanech. Stojany mají rozměry 42U, 80x80 cm. Do každého stojanu je požadováno dále dodat a nainstalovat: monitoring stojanu (teplota, vlhkost, otevření dveří), ventilační jednotku (min. 2x ventilátor) řízenou termostatem, boční třmen pro vedení kabelů, horizontální kabelovou instalační lištu. Stojany včetně vybavení je požadováno uzemnit. Pro napájení technologie se požaduje dodat 1x UPS 2200 W včetně instalace a zprovoznění. Požadované parametry UPS: montáž do 19“ stojanu, SNMP/HTTP management, automatický bypass, min. počet zásuvek. 6x C13. UPS bude napájena ze stávajícího napájecího panelu ve stojanu. Jako druhý zdroj napájení se použije stávající zálohovaný zásuvkový panel umístěný v jednom ze stojanů. Přívody napájení k zařízením mezi oběma sousedícími stojany se požaduje vést pod zdvojenou podlahou. Dodávaná zařízení je požadováno připojit na napájení na UPS, a to redundantní zdroje vždy na rozdílnou UPS.
Strojnická
Technologii se požaduje instalovat do volného prostoru ve stávající stojanu. Stojan má rozměry 42U, 60x120 cm. Do stojanu je požadováno dále dodat a nainstalovat: monitoring stojanu (teplota, vlhkost, otevření dveří), ventilační jednotku (min. 2x ventilátor) řízenou termostatem, 2x boční třmen pro vedení kabelů, 2x horizontální kabelová instalační lišta, 2x napájecí panel se zásuvkami min. 6x UTE. Stojan včetně vybavení je požadováno uzemnit. Pro napájení technologie se požaduje dodat 2x UPS 2200 W včetně instalace a zprovoznění. Požadované parametry UPS: montáž do 19“ stojanu, SNMP/HTTP management, automatický bypass, min. počet zásuvek 6x C13. Ke každé UPS je požadováno přivést jinou větev silového rozvodu jištěnou 16A jističem. Jističe je požadováno instalovat do podružného rozvaděče v místnosti, kabely budou ke stojanu vedeny po stávajících podstropních roštech, kabelová vzdálenost je do 25 m.
Bubenečská
Technologii se požaduje instalovat do volného prostoru ve dvou stávajících stojanech. Stojany mají rozměry 42U, 80x100 cm. Do každého stojanu je požadováno dále dodat a nainstalovat: monitoring stojanu (teplota, vlhkost, otevření dveří), ventilační jednotku (min. 2x ventilátor) řízenou termostatem, 2x boční třmen pro vedení kabelů, 2x horizontální kabelová instalační lišta, 1x napájecí panel se zásuvkami min 6x UTE. Stojany včetně vybavení je požadováno uzemnit. Pro napájení technologie se požaduje dodat do každého stojanu 2x UPS 3000 W včetně instalace a zprovoznění. Požadované parametry UPS: montáž do 19“ stojanu, SNMP/HTTP management, automatický bypass, min. počet zásuvek 10x C13. Pro napájení zařízení je požadováno zabezpečit do každého stojanu dvě větve silového rozvodu. Jedna větev bude přivedena ze stávající napájecí lišty ve stojanu a přivedena do UPS. Druhou větev je požadováno dovést z podružného rozvaděče umístěného na chodbě, kde je požadováno dodat jistič 16A. Kabelová vzdálenost je cca 20m. Tato větev bude přivedena do dodávaného napájecího panelu a odtud bude připojena UPS. Dodávaná zařízení je požadováno připojit na napájení na UPS, a to redundantní zdroje vždy na rozdílnou UPS.
16
Bartolomějská
Pro instalaci technologie je požadováno dodat a namontovat stojan 19“ velikosti 42U, šířka 800 mm, hloubka 1 000 mm o zatížitelnosti min 1000 kg s touto výstrojí: - Přední dveře perforované, míra perforace min 60%; uzamykatelné, výklopná klika s bezpečnostní vyměnitelnou vložkou, univerzální klíč, tříbodové zamykání, - Zadní dveře tahokov, míra perforace cca 80%, vertikálně dělené, výklopná klika s vyměnitelnou bezpečnostní vložkou, univerzální klíč, tříbodové zamykání, - 2 bočnice celoplechové, univerzální klíč, - Horní kryt, podstavec, - 2x napájecí panel (PDU), zásuvky min. 12x UTE, 6x C13, jištění 16A, 1U, montáž 19“, - 2x boční třmen pro vedení kabelů, 2x horizontální kabelové instalační lišty, - Monitoring stojanu (teplota, vlhkost, otevření dveří), - Ventilační jednotka řízená termostatem, min. 2x ventilátor, instalovaná do horního rámu, - Souprava pro uzemnění stojanu a zemnící lišta Pro napájení technologie se požaduje dodat 1x UPS 2200 W včetně instalace a zprovoznění. Požadované parametry UPS: montáž do 19“ stojanu, SNMP/HTTP management, automatický bypass, min. počet zásuvek 6x C13. UPS bude napájena z dodávaného napájecího panelu. Na panel bude napájení přivedeno z podružného rozvodu místnosti, který je požadováno doplnit jističem 16A. Na druhý napájecí panel je požadováno přivést napájení ze střídače stávajícího napaječe. Kabelové vzdálenosti jsou cca 10 m. Dodávaná zařízení je požadováno připojit na napájení na UPS, a to redundantní zdroje vždy na rozdílnou UPS.
6 Další podmínky plnění Součástí plnění je zpracování zjednodušeného realizačního technologického projektu, instalace, zprovoznění a zpracování dokumentace skutečného provedení. Projektová dokumentace a dokumentace skutečného provedení musí být zpracována v českém jazyce. Technická dokumentace, odkazy na technickou a doporučenou dokumentaci výrobce mohou být v českém nebo anglickém jazyce. Zadavatel požaduje vyhotovení projektové dokumentace v následujícím rozsahu:
a) Zjednodušený realizační technologický projekt - obsahuje souhrnnou technickou zprávu (základní údaje, zajištění dodávek a prací, popis instalované technologie, umístění instalované technologie, řešení silnoproudého napájení a uzemnění, slaboproudé napojení, dohled, chlazení a případnou podmiňující výstavbu či úpravy), specifikaci zařízení a výkaz výměr. Nutnou součástí projektu je výkresová část obsahující situační plán, blokové schéma, obsazení racku/ů, obsazení subracků a kabelový plán. Tato projektová dokumentace se zpracovává před instalací.
b) Dokumentace skutečného provedení – upravený realizační projekt, v němž jsou zohledněny veškeré změny, které nastaly při instalaci a popisující skutečný stav předávaného díla.
Dílo bude předáno zadavateli na základě úspěšně provedených přejímacích testů, jímž uchazeč prokáže, že dílo odpovídá technickým specifikacím v zadávací dokumentaci, plní požadované funkcionality a je schopné provozu. Návrh testů předloží uchazeč jako součást nabídky. 17
Záruka na dodané dílo se požaduje v délce 3 let, kdy uchazeč je povinen bezplatně opravit dodané komponenty během následujícího pracovního dne po nahlášení závady. Rovněž je povinen garantovat, že po dobu záruky bude zajištěn přístup k aktualizacím dodaného SW.
18