Microflex Advance ANI4OUT Microflex Advance ANI4OUT
Deskripsi Umum Shure Antarmuka Jaringan Audio mengkonversi 4 saluran audio digital Dante™ menjadi sinyal analog diskrit. Hubungkan ke perangkat pemrosesan dengan koneksi analog (pembatal gema, antarmuka VOIP/telepon, unit DSP, misalnya) untuk mengintegrasikan sepenuhnya audio jaringan dan peralatan analog dalam satu sistem. Tersedia dalam versi XLR dan konektor blok, masing-masing kotak menggunakan kabel jaringan tunggal untuk menerima audio dan daya melalui Power over Ethernet (PoE).
Model Variations ANI4OUT-XLR: Four XLR outputs (balanced audio) ANI4OUT-BLOCK: Four 3-pin block connector outputs (balanced audio)
Perangkat keras Model Konektor Blok
OUTPUT sig/clip
1
3
PoE power
1 2
network
3
network audio
4
2
4
encryption reset
sig/clip 1
power
2
network
3
network audio
4
encryption
Panel Depan Model XLR
©2013 Shure Incorporated
1/20
Microflex Advance ANI4OUT Microflex Advance ANI4OUT
Shure Incorporated
OUTPUT PoE
reset
Panel Belakang
Panel Depan ① Indikator Tingkat Output (Sinyal/Pemotongan) LED dua warna menunjukkan tingkat sinyal audio untuk setiap saluran. Sesuaikan tingkat di aplikasi web untuk menghindari pemotongan. Hijau: Ada sinyal audio Merah: Pemotongan sinyal audio ② Output Audio Output audio seimbang analog terhubung ke perangkat analog. Atur tingkat output di aplikasi web Untuk menyesuaikan dengan sensitivitas input perangkat analog. Penetapan pin XLR: 1
Pelindung
2
+
3
-
Penetapan pin blok konektor: Lihat label panel depan ③ Sekrup Arde Casis Memberikan sambungan opsional untuk kabel pelindung mikrofon ke arde casis ④ Indikator LED Daya: Ada Power over Ethernet (PoE) Catatan: Catatan: Gunakan injektor PoE jika sakelar jaringan Anda tidak menyediakan PoE. Jaringan: Koneksi jaringan aktif Audio Jaringan: Ada audio Dante™ di jaringan Enkripsi: Saat ini tidak didukung ⑤ Port Jaringan Dante Terhubung ke sakelar jaringan untuk menerima audio Dante™ audio, Power over Ethernet (PoE), dan data dari perangkat lunak kontrol. ⑥ Tombol Atur Ulang Mengatur ulang pengaturan perangkat kembali ke default pabrik Catatan:kata sandi dan informasi pengguna tidak dihapus ketika perangkat diatur ulang.
2/20
2016/08/16
Microflex Advance ANI4OUT Microflex Advance ANI4OUT
Shure Incorporated
Instalasi dan Pemasangan di Rak Dua solusi pemasangan tersedia untuk menginstal Antamuka Jaringan Audio: Baki Rak CRT1 19" (aksesori opsional): Mendukung hingga 3 perangkat, dapat dipasang di rak atau di bawah meja Baki Pemasangan Satu Unit (aksesori yang disertakan): Mendukung satu perangkat untuk dipasang di bawah meja
Mengamankan Perangkat Gunakan sekrup yang disertakan dari kit perangkat keras pemasangan untuk mengamankan Antarmuka Jaringan Audio. Antarmuka Jaringan Audio dapat dipasang menghadap ke salah satu arah. Masukkan sekrup dari bagian bawah di lubang yang sesuai, berdasarkan diagram berikut:
Luruskan lubang seperti ditunjukkan untuk mengamankan satu perangkat di baki pemasangan satu perangkat Perangkat 1
Perangkat 2
Perangkat 3
Luruskan lubang seperti ditunjukkan untuk mengamankan hingga tiga perangkat di baki rak 19".
Konfigurasi Partisi Rak Kombinasi hingga 3 Antarmuka Jaringan Audio dapat dipasang di satu ruang rak 19 inci. Partisi rak yang dapat disesuaikan mendukung pemasangan di rak peralatan standar atau di bawah meja.
Pemasangan Rak Standar 19" 1. Luruskan partisi dengan lubang pemasangan yang mengarah ke depan. 2. Pasang dua sekrup yang menahan partisi ke baki seperti ditunjukkan.
Pemasangan Di Bawah Meja 1. Luruskan partisi dengan lubang pemasangan yang mengarah ke atas. 2. Pasang dua sekrup yang menahan partisi ke baki seperti ditunjukkan.
Memasang Di Bawah Meja 1. Tahan baki di lokasi yang diinginkan di bawah meja 2. Gunakan pensil untuk menandai lokasi lubang pemasangan di meja. 3. Bor 4 lubang untuk sekrup. Diameter lubang di baki adalah 7,1 mm. 4. Pasang komponen ke baki 5. Pasang dengan 4 sekrup untuk mengamankan baki di bawah meja
Power Over Ethernet (PoE) Perangkat ini membutuhkan PoE untuk beroperasi. Perangkat ini kompatibel dengan sumber PoE Kelas 0 dan Kelas 3. Power over Ethernet disampaikan melalui salah satu cara berikut: •
Sakelar jaringan yang menyediakan PoE
•
Perangkat penginjeksi PoE
Reset The reset button is located inside a small hole in the front panel. Use a paperclip or other small tool to press the button. 2016/08/16
3/20
Microflex Advance ANI4OUT Microflex Advance ANI4OUT
Shure Incorporated
There are two reset functions: Network reset (press button for 4-8 seconds) Resets all Shure control and audio network IP settings to factory defaults Full factory reset (press button for longer than 8 seconds) Restores all network and web application settings to the factory defaults.
4/20
2016/08/16
Microflex Advance ANI4OUT Microflex Advance ANI4OUT
Shure Incorporated
Koneksi dan Aliran Sinyal Perangkat audio Dante
Sakelar Jaringan
OUTPUT sig/clip
1
3 power
1 2
network
3
network audio
4
2
4
encryption
PoE reset
Prosesor Audio Output ke server (VOIP atau telepon)
Input: Audio Digital Dante™ Satu kabel jaringan menyalurkan 4 saluran audio dan Power over Ethernet (PoE). Gunakan Pengontrol Dante™ untuk merutekan saluran audio dari jaringan ke antarmuka jaringan.
Output: Analog (4 XLR atau Konektor Blok) Masing-masing output mengirimkan saluran audio diskrit untuk menghubungkan ke perangkat analog.
Setting up the Audio Network Shure networked conferencing systems are comprised of Microflex Advance microphones and network interfaces, which operate entirely on a Dante™ network. Additional hardware, including network switches, computers, loudspeakers, and audio processors are described in the hardware component index. Shure components shown in this diagram: Microflex Advance Microphones The MXA910 and MXA310 are equipped with Dante outputs, and connect directly to a network switch. Audio Network Interfaces The interfaces are used to connect analog devices such as loudspeakers and analog microphones to the network. ANI4IN: Converts 4 analog signals (separate XLR and block connector models available) into Dante™ digital audio signals. ANI4OUT: Converts 4 channels of Dante™ audio from the network into analog signals.
2016/08/16
5/20
Microflex Advance ANI4OUT Microflex Advance ANI4OUT
Shure Incorporated
This diagram shows the entire signal path through a networked conference system. Signals from the near end and far end are exchanged through an audio processor connected to a phone system, or through a computer connected to the internet. Analog microphones connect to the network through the Shure ANI4IN, while loudspeakers connect through the Shure ANI4OUT.
6/20
2016/08/16
Microflex Advance ANI4OUT Microflex Advance ANI4OUT
Shure Incorporated
This diagram shows Microflex Advance components in context, with two rooms communicating through video codecs.
Controlling Hardware and Audio Over the Network Audio and hardware settings are managed through a computer connected to the same network.
2016/08/16
7/20
Microflex Advance ANI4OUT Microflex Advance ANI4OUT
Shure Incorporated
Shure Hardware and Audio Each Microflex Advance component has a web application which provides mixing and configuration tools to optimize sound quality.
Expanded Control for Analog Devices Analog devices that are connected to the network through a Shure network interface (ANI4IN/ANI4OUT) benefit from additional remote control: Volume levels, equalization, and signal routing are managed through the web application. For example, adjusting loudspeaker volume or muting a wired microphone, which would normally be done from the hardware, can now be controlled remotely over the network.
Dante™ Signal Routing Signal routing between devices is managed through Dante Controller software, provided by Audinate™ .
Rangkuman Antarmuka Jaringan Audio Menyediakan rangkuman saluran untuk menggabungkan sinyal Dante™ dari jaringan, dan mengirimkannya melalui satu output analog. Hal ini memungkinkan untuk mengirimkan semua saluran ke perangkat dengan jumlah saluran input analog yang terbatas. Fungsionalitas Mixer tidak berubah; saluran audio hanya dikrimkan sebagai satu sinyal gabungan. Untuk mengaktifkan, pilih salah satu opsi rangkuman di bilah alat di bagian atas mixer pada tab saluran.
1 2 3
1 2
1+2
2 3
3+4
4
3+4
4
1
1 2
1
1 +2 1+2+3+4
2
3
3
3
4
4
4
Using the Software Instalasi Perangkat Lunak dan Device Discovery Aplikasi Shure Web Device Discovery digunakan untuk mengakses aplikasi web untuk perangkat Shure. Aplikasi web terbuka di browser web untuk memberikan pengelolaan perangkat komprehensif. Setiap komputer yang terhubung lewat jaringan ke perangkat dapat mengakses GUI dengan aplikasi ini. Browser yang Kompatibel: •
Chrome
•
Safari
•
Firefox
•
Internet Explorer
1. Instal aplikasi device discovery Shure, yang tersedia di www.shure.com 2. Klik dua kali komponen untuk membuka antarmuka.
Mengakses Aplikasi Web Aplikasi Shure Web Server Discovery menemukan semua perangkat Shure pada jaringan yang menyoroti GUI web-dasar. Ikuti langkah-langkah ini untuk menginstal perangkat lunak dan mengakses aplikasi web:
① Instal aplikasi Shure Discovery Unduh dan instal aplikasi Shure Discovery dari www.shure.com. Ini secara otomatis menginstal alat temuan perangkat Bonjour yang diperlukan pada komputer. 8/20
2016/08/16
Microflex Advance ANI4OUT Microflex Advance ANI4OUT
Shure Incorporated
② Menyambungkan jaringan Pastikan komputer dan perangkat keras berada di jaringan yang sama.
③ Buka aplikasi Discovery Apl ini menampilkan semua perangkat Shure yang menonjolkan GUI.
④ Mengidentifikasi perangkat keras Klik dua kali perangkat untuk membuka GUI di peramban web.
⑤ Menandai aplikasi web perangkat (direkomendasikan) Tandai halaman nama DNS perangkat untuk mengakses GUI tanpa apl Shure Discovery.
Mengakses Aplikasi Web tanpa Aplikasi Discovery Jika aplikasi Discovery tidak diinstal, aplikasi web dapat diakses dengan mengetik nama DNS di browser internet. Nama DNS diturunkan dari model unit, bersama-sama dengan tiga bita terakhir (enam digit) alamat MAC, dan berakhir dalam .local. Contoh Format: Jika alamat MAC sebuah unit adalah 00:0E:DD:AA:BB:CC, maka tautan dituliskan sebagai berikut: ANI4IN: http://ANI4IN-aabbcc.local ANI4OUT: http://ANI4OUT-aabbcc.local
Pembaruan Firmware Firmware adalah perangkat lunak yang dipasang di setiap komponen yang mengontrol fungsionalitas. Secara berkala, versi baru firmware dikembangkan untuk memberikan beragam fitur dan penyempurnaan tambahan. Untuk memanfaatkan peningkatan desain, versi baru firmware dapat diunduh dan diinstal menggunakan Shure Update Utility. Perangkat lunak tersedia untuk diunduh dari http://www.shure.com. ®
Penting: Apabila komponen Microflex Advance™ terhubung melalui Antarmuka Jaringan Audio Shure MXW, firmwarenya harus diperbarui pada satu demi satu perangkat sebelum memperbarui firmware Antarmuka Jaringan Audio MXW. Mencoba memperbarui semua perangkat sekaligus akan menyebabkan antarmuka dinyalakan ulang setelah firmwarenya diperbarui, dan sambungan ke komponen jaringan lain akan hilang. Lakukan langkah-langkah berikut untuk memperbarui firmware: HATI-HATI! Pastikan perangkat memiliki koneksi jaringan yang stabil selama pembaruan. Jangan matikan perangkat hingga pembaruan selesai. 1. Sambungkan perangkat dan komputer ke jaringan yang sama (diatur ke subnet yang sama). 2. Unduh aplikasi Shure Update Utility lalu instal. 3. Buka aplikasi. 4. Klik tombol Check For Updates... untuk melihat versi firmware baru yang tersedia untuk diunduh. 5. Pilih firmware yang diinginkan lalu tekan Downloaduntuk mengunduhnya ke Firmware Library. 6. Dari tab Update Devices, pilih firmware baru lalu tekan Send Updates... untuk memulai pembaruan firmware, yang menggantikan firmware yang ada pada perangkat.
Persyaratan Rilis Firmware ®
Perangkat Microflex Advance™ membentuk jaringan dengan beberapa protokol komunikasi yang bekerja sama untuk memastikan pengoperasian dengan ® baik. Penerapan terbaik yang direkomendasikan adalah semua perangkat Microflex Advance™ dari rilis yang identik. Untuk melihat versi firmware tiap perangkat pada jaringan, buka komponen antarmuka pengguna, lalu cari di bawah Settings>About. Format untuk firmware perangkat Shure adalah MAYOR.MINOR.PATCH. (Contoh 1.6.2 yang artinya 1 adalah level firmware Mayor, 6 adalah level firmware Minor, dan 2 adalah level firmware Patch.) Setidaknya, perangkat yang beroperasi di subnet yang sama harus memiliki nomor rilis MAYOR dan MINOR yang identik. •
Perangkat dengan rilis MAYOR berbeda tidak kompatibel.
•
Perbedaan pada tingkat rilis firmware PATCH dapat menimbulkan inkonsistensi yang tidak diinginkan.
Parametric Equalizer Maximize audio quality by adjusting the frequency response with the parametric equalizer. Common equalizer applications: •
Improve speech clarity
•
Reduce noise from HVAC systems or video projectors
•
Reduce room irregularities
•
Adjust frequency response for reinforcement systems
2016/08/16
9/20
Microflex Advance ANI4OUT Microflex Advance ANI4OUT
Shure Incorporated
Setting Filter Parameters Adjust filter settings by manipulating the icons in the frequency response graph, or by entering numeric values. Disable a filter using the check-box next to the filter. Filter Type Only the first and last band have selectable filter types. Parametric: Attenuates or boosts the signal within a customizable frequency range Low Cut: Rolls off the audio signal below the selected frequency Low Shelf: Attenuates or boosts the audio signal below the selected frequency High Cut: Rolls off the audio signal above the selected frequency High Shelf: Attenuates or boosts the audio signal above the selected frequency Frequency Select the center frequency of the filter to cut/boost Gain Adjusts the level for a specific filter (+/- 30 dB) Q Width Adjusts the range of frequencies affected by the filter. As this value increases, the bandwidth becomes thinner.
10/20
2016/08/16
Microflex Advance ANI4OUT Microflex Advance ANI4OUT
Shure Incorporated
Equalizer Applications Conferencing room acoustics vary based on room size, shape, and construction materials. Use the guidelines in following table.
2016/08/16
EQ Application
Suggested Settings
Treble boost for improved speech intelligibility
Add a high shelf filter to boost frequencies greater than 1 kHz by 3-6 dB
HVAC noise reduction
Add a low cut filter to attenuate frequencies below 200 Hz 11/20
Microflex Advance ANI4OUT Microflex Advance ANI4OUT
Shure Incorporated
EQ Application
Suggested Settings Identify the specific frequency range that "excites" the room: Set a narrow 1. Q value
Reduce flutter echoes and sibilance
Increase the gain to between +10 2. and +15 dB, and then experiment with frequencies between 1 kHz and 6 kHz to pinpoint the range of flutter echoes or sibilance Reduce the gain at the identified 3. frequency (start between -3 and -6 dB) to minimize the unwanted room sound Identify the specific frequency range that "excites" the room: Set a narrow 1. Q value
Reduce hollow, resonant room sound
Increase the gain to between +10 2. and +15 dB, and then experiment with frequencies between 300 Hz and 900 Hz to pinpoint the resonant frequency Reduce the gain at the identified 3. frequency (start between -3 and -6 dB) to minimize the unwanted room sound
Catatan Kejadian Catatan harian kejadian memberikan rincian perhitungan kegiatan sejak perangkat dinyalakan. Catatan mengumpulkan hingga 1.000 masukan kegiatan dan memberinya cap waktu relatif terhadap siklus daya terakhir. Untuk memecahkan masalah audio atau perangkat keras, simpan catatan menggunakan tombol ekspor. Lihat file catatan untuk mengetahui detail ketika memecahkan masalah atau berkonsultasi dengan Dukungan Sistem Shure. Untuk melihat catatan kejadian: 1. Buka menu Bantuan 2. Pilih Lihat Catatan Kejadian Tingkat Keparahan Informasi Tindakan atau kejadian telah berhasil diselesaikan Peringatan Tindakan tidak bisa diselesaikan, namun fungsionalitas keseluruhan stabil Kesalahan Terjadi masalah yang dapat menghambat fungsionalitas. Tip: Gunakan filter untuk mempersempit hasil.
Adjusting Input levels 1. Check the source level before it reaches the Network Interface: ⁃ ⁃
Verify that the networked microphones or other Dante™ sources are operating at nominal output levels. Levels for Microflex Advance™ microphones are adjustable through their web application.
2. Adjust the digital gain in the Network Interface web application:
•
Line level (0 dB)
•
Aux level (-27 dB)
•
Microphone level (-45 dB)
LED Signal and Clipping Indicators Each analog output channel has a corresponding LED:
⁃
Use the faders or manually enter a gain value.
⁃
The digital gain adjusts the level of the signal before it reaches the analog circuitry.
Green: Audio signal present Red: Audio signal is clipping and should be attenuated.
⁃
Set these levels as high as possible without reaching the peak level (0 dB) on the meter.
Note: the meters in the web application are not affected by the Penguatan Analog (dB) setting.
Adjusting Output Levels
Pre- and Post-Fader Metering
Access the analog output levels through the web application, by selecting an output level from the Penguatan Analog (dB) pull-down menu. Match the output level from the Network Interface to the input sensitivity on the analog device:
There are two modes for monitoring so that both the input and output signals can be monitored separately. When set to pre-fader, the meter displays the signal level from the source on the Dante network. If signals are too low or clipping, adjust them at the source. When set to post-fader, the meter is affected by the digital gain. It is not affected by the output analog gain setting.
12/20
2016/08/16
Microflex Advance ANI4OUT Microflex Advance ANI4OUT
Shure Incorporated
ANI4OUT Command Strings This document can also be found at: http://shure.custhelp.com/app/answers/detail/a_id/6060 The device is connected via Ethernet to a control system, such as AMX, Crestron or Extron. Connection: Ethernet (TCP/IP; select “Client” in the AMX/Crestron program) Port: 2202
Conventions The device has 4 types of strings: GET Finds the status of a parameter. After the AMX/Crestron sends a GET command, the ANI4OUT responds with a REPORT string SET Changes the status of a parameter. After the AMX/Crestron sends a SET command, the ANI4OUT will respond with a REPORT string to indicate the new value of the parameter. REP When the ANI4OUT receives a GET or SET command, it will reply with a REPORT command to indicate the status of the parameter. REPORT is also sent by the ANI4OUT when a parameter is changed on the ANI4OUT or through the GUI. SAMPLE Used for metering audio levels. All messages sent and received are ASCII. Note that the level indicators and gain indicators are also in ASCII Most parameters will send a REPORT command when they change. Thus, it is not necessary to constantly query parameters. The ANI4OUT will send a REPORT command when any of these parameters change. The character “x” in all of the following strings represents the channel of the ANI4OUT and can be ASCII numbers 0 through 4 as in the following table 0
All channels
1 through 4
Individual channels
Command Strings (Common) Get All Where x is ASCII channel number: 0 through 4. Use this command on first power on to update the status of all parameters.
Command String: < GET x ALL > ANI4OUT Response:
The ANI4OUT responds with individual Report strings for all parameters.
< REP ... > Get Channel Name Command String:
Where x is ASCII channel number: 0 through 4.
< GET x CHAN_NAME ANI4OUT Response: < REP x CHAN_NAME {yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy} >
Where yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy is 31 characters of the user name.The ANI4OUT always responds with a 31 character name.
Get Device ID Command String:
The Device ID command does not contain the x channel character, as it is for the entire ANI4OUT.
< GET DEVICE_ID > ANI4OUT Response: < REP DEVICE_ID {yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy} >
Where yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy is 31 characters of the device ID. The ANI4OUT always responds with a 31 character device ID.
Get Preset Command String: < GET PRESET > ANI4OUT Response: < REP PRESET nn > 2016/08/16
Where nn is the preset number 01-10.
13/20
Microflex Advance ANI4OUT Microflex Advance ANI4OUT
Shure Incorporated
Set Preset Command String:
Where nn is the preset number 1-10. (Leading zero is optional when using the SET command).
< SET PRESET nn > ANI4OUT Response:
Where nn is the preset number 01-10.
< REP PRESET nn > Get Preset Name Command String: < GET PRESET1 >
Send one of these commands to the ANI4OUT
< GET PRESET2 > < GET PRESET3 > etc ANI4OUT Response: < REP PRESET1 {yyyyyyyyyyyyyyyyyyyyyyyyy} > < REP PRESET2 {yyyyyyyyyyyyyyyyyyyyyyyyy} > < REP PRESET3 {yyyyyyyyyyyyyyyyyyyyyyyyy} >
Whereyyyyyyyyyyyyyyyyyyyyyyyyy is 25 characters of the device ID. The ANI4OUT always responds with a 25 character device ID
etc Get Audio Gain Command String: < GET x AUDIO_GAIN_HI_RES > ANI4OUT Response: < REP x AUDIO_GAIN_HI_RES yyyy >
Where x is ASCII channel number: 1 through 4. Where yyyy takes on the ASCII values of 0000 to 1400. yyyy is in steps of one-tenth of a dB.
Set Audio Gain Command String: < SET x AUDIO_GAIN_HI_RES yyyy > ANI4OUT Response: < REP x AUDIO_GAIN_HI_RES yyyy >
Where yyyy takes on the ASCII values of 0000 to 1400. yyyy is in steps of one-tenth of a dB. Where yyyy takes on the ASCII values of 0000 to 1400.
Increase Audio Gain by n dB Command String: < SET x AUDIO_GAIN_HI_RES INC nn > ANI4OUT Response: < REP x AUDIO_GAIN_HI_RES yyyy >
Where nn is the amount in one-tenth of a dB to increase the gain. nn can be single digit ( n ), double digit ( nn ), triple digit ( nnn ). Where yyyy takes on the ASCII values of 0000 to 1400.
Decrease Audio Gain by n dB Command String: < SET x AUDIO_GAIN_HI_RES DEC nn > ANI4OUT Response: < REP x AUDIO_GAIN_HI_RES yyyy >
Where nn is the amount in one-tenth of a dB to decrease the gain. nn can be single digit ( n ), double digit ( nn ), triple digit ( nnn ). Where yyyy takes on the ASCII values of 0000 to 1280.
Get Channel Audio Mute Command String: < GET x AUDIO_MUTE >
Where x is ASCII channel number: 0 through 4.
ANI4OUT Response: < REP x AUDIO_MUTE ON >
The ANI4OUT will respond with one of these strings.
< REP x AUDIO_MUTE OFF > Mute Channel Audio Command String: < SET x AUDIO_MUTE ON >
14/20
2016/08/16
Microflex Advance ANI4OUT Microflex Advance ANI4OUT
Shure Incorporated
ANI4OUT Response: < REP x AUDIO_MUTE ON > Unmute Channel Audio Command String: < SET x AUDIO_MUTE OFF > ANI4OUT Response: < REP x AUDIO_MUTE OFF > Toggle Channel Audio Mute Command String: < SET x AUDIO_MUTE TOGGLE > ANI4OUT Response: < REP x AUDIO_MUTE ON >
The ANI4OUT will respond with one of these strings.
< REP x AUDIO_MUTE OFF > Get Analog Gain Command String: < GET x AUDIO_OUT_LVL_SWITCH >
Where x is ASCII channel number: 0 through 4.
ANI4OUT Response: < REP x AUDIO_OUT_LVL_SWITCH LINE_LVL > < REP x AUDIO_OUT_LVL_SWITCH AUX_LVL >
The ANI4OUT will respond with one of these strings.
< REP x AUDIO_OUT_LVL_SWITCH MIC_LVL > Set Analog Gain Command String: < SET x AUDIO_OUT_LVL_SWITCH LINE_LVL > < SET x AUDIO_OUT_LVL_SWITCH AUX_LVL >
Where x is ASCII channel number: 0 through 4. Send one of these commands to the ANI4OUT.
< SET x AUDIO_OUT_LVL_SWITCH MIC_LVL > ANI4OUT Response: < REP x AUDIO_OUT_LVL_SWITCH LINE_LVL > < REP x AUDIO_OUT_LVL_SWITCH AUX_LVL >
The ANI4OUT will respond with one of these strings.
< REP x AUDIO_OUT_LVL_SWITCH MIC_LVL > Get Sig/Clip LED Command String: < GET x LED_COLOR_SIG_CLIP >
Where x is ASCII channel number: 0 through 4. It is not necessary to continually send this command. The ANI4OUT will send a REPORT message whenever the status changes.
ANI4OUT Response: < REP x LED_COLOR_SIGL_CLIP OFF > < REP x LED_COLOR_SIG_CLIP GREEN > < REP x LED_COLOR_SIG_CLIP AMBER >
The ANI4OUT will respond with one of these strings. This matches the sig/clip LEDs on the front of the ANI4OUT.
< REP x LED_COLOR_SIG_CLIP RED > Flash Lights on ANI4OUT Command String: Send one of these commands to the ANI4OUT. The flash automatically turns off after 30 seconds.
< SET FLASH ON > < SET FLASH OFF > ANI4OUT Response:
The ANI4OUT will respond with one of these strings.
< REP FLASH ON > < REP FLASH OFF > Turn Metering On
2016/08/16
15/20
Microflex Advance ANI4OUT Microflex Advance ANI4OUT
Shure Incorporated
Where sssss is the metering speed in milliseconds. Setting sssss=0 turns metering off. Minimum setting is 100 milliseconds. Metering is off by default.
Command String: < SET METER_RATE sssss >
Where aaa, bbb, etc is the value of the audio level received and is 000-060.
ANI4OUT Response:
aaa = output 1
< REP METER_RATE sssss >
bbb = output 2
< SAMPLE aaa bbb ccc ddd >
ccc = output 3 ddd = output 4
Stop Metering Command String:
A value of 00000 is also acceptable.
< SET METER_RATE 0 > ANI4OUT Response: < REP METER_RATE 00000 > Get LED Brightness Command String: < GET LED_BRIGHTNESS >
Where n can take on the following values: 0 = LED disabled
ANI4OUT Response:
1 = LED dim
< REP LED_BRIGHTNESS n >
2 = LED default Set LED Brightness Where n can take on the following values: Command String: < SET LED_BRIGHTNESS n >
0 = LED disabled 1 = LED dim 2 = LED default
ANI4OUT Response: < REP LED_BRIGHTNESS n >
Dante & Networking Jaringan Audio Digital Audio digital Dantetm dilakukan di atas Ethernet standar dan dioperasikan menggunakan Protokol Internet standar. Dante memberikan latensi yang rendah, sinkronisasi jam yang ketat, dan Kualitas Layanan (Quality-of-Service/QoS) yang tinggi untuk memberikan pengiriman audio yang tepercaya ke berbagai perangkat Dante. Audio Dante dapat berdampingan di jaringan yang sama sebagai data IT dan data kontrol, atau dapat diatur untuk menggunakan jaringan yang ditetapkan.
Rekomendasi Sakelar untuk Jaringan Dante Selain persyaratan jaringan dasar, jaringan audio Dante harus menggunakan sakelar jaringan Gigabit atau router dengan fitur sebagai berikut: •
Port gigabit
•
Quality of Service (QoS) (Kualitas Servis) dengan 4 antrian
•
Diffserv (DSCP) QoS, dengan prioritas ketat
•
Dianjurkan: Sakelar dikelola untuk memberikanrincian informasi tentang pengoperasian setiap tautan jaringan (kecepatan port, kesalahan penghitung, bandwidth digunakan)
QoS (Quality of Service) Settings QoS settings assign priorities to specific data packets on the network, ensuring reliable audio delivery on larger networks with heavy traffic. This feature is available on most managed network switches. Although not required, assigning QoS settings is recommended. Note: Coordinate changes with the network administrator to avoid disrupting service. To assign QoS values, open the switch interface and use the following table to assign Dante™ -associated queue values. 16/20
2016/08/16
Microflex Advance ANI4OUT Microflex Advance ANI4OUT
Shure Incorporated
•
Assign the highest possible value (shown as 4 in this example) for time-critical PTP events
•
Use descending priority values for each remaining packet. ®
Table provided courtesy of Audinate Priority
Usage
DSCP Label
Hex
Decimal
Binary
High (4)
Time-critical PTP events
CS7
0x38
56
111000
Medium (3)
Audio, PTP
EF
0x2E
46
101110
Low (2)
(reserved)
CS1
0x08
8
001000
None (1)
Other traffic
BestEffort
0x00
0
000000
Note: Switch management may vary by manufacturer and switch type. Consult the manufacturer's product guide for specific configuration details. For more information on Dante requirements and networking, visit www.audinate.com.
Networking Terminology PTP (Precision Time Protocol): Used to synchronize clocks on the network DSCP (Differentiated Services Code Point): Standardized identification method for data used in layer 3 QoS prioritization
Aliran Transmisi Dante Untuk setiap perangkat, dibatasi 2 aliran transmisi dan 2 aliran terima. Satu aliran terdiri dari satu transmisi unicast atau multicast, dan mendukung hingga 4 saluran audio. •
Aliran unicast adalah koneksi titik-ke-titik antara 2 perangkat, mendukung hingga 4 saluran per aliran. Untuk mengirim 8 saluran audio antara dua perangkat, diperlukan 2 aliran unicast.
•
Aliran multicast adalah transmisi satu-ke-banyak, yang mendukung pengiriman hingga 4 saluran ke beberapa perangkat penerima di seluruh jaringan. Untuk mengirim 8 saluran dari satu perangkat ke semua perangkat lain di jaringan, diperlukan 2 aliran multicast.
Informasi Penting Produk Peralatan ini ditujukan untuk digunakan dalam aplikasi audio profesional. Catatan: Perangkat ini tidak dimaksudkan untuk disambungkan langsung ke jaringan internet umum.
yang mana dapat dimatikan dengan memutar alat off dan on, pengguna dianjurkan untuk mencoba membetulkan gangguan melalui satu atau lebih langkah-langkah berikut: •
Reposisi atau pindahkan antena penerimaan.
•
Tingkatkan pemisahan antara peralatan dengan receiver.
•
Hubungkan peralatan ke stopkontak pada sirkuit yang berbeda dari mana receiver terhubung.
Perubahan atau modifikasi yang tidak disetujui oleh Perusahaan Shure dapat membatalkan hak Anda untuk mengoperasikan peralatan ini.
•
Konsultasikan dengan penjual atau teknisi radio/TV berpengalaman untuk bantuan.
Label Kepatuhan Industry Canada ICES-003: CAN ICES-3 (B)/NMB-3(B)
Pernyataan Kesesuaian CE bisa diperoleh di: www.shure.com/europe/compliance
Penyesuaian EMC ke Lingkungan E2: Komersial dan Industri Ringan. Pengujian berdasarkan pada penggunaan jenis kabel yang disediakan dan dianjurkan. Penggunaan selain jenis kabel yang berpelindung dapat menurunkan performa EMC.
Resmi berdasarkan ketentuan verifikasi FCC Bagian 15B. Silahkan ikuti skema daur ulang di daerah Anda untuk limbah baterai, kemasan dan elektronik.
Informasi bagi pengguna Peralatan ini telah diuji dan dibuat sesuai batas alat digital Kelas B, sesuai dengan bagian 15 dari Peraturan FCC. Batasan ini di design untuk memberikan perlindungan yang layak terhadap gangguan berbahaya dalam pemasangan dilingkungan tempat tinggal. Peralatan ini menghasilkan, menggunakan dan dapat memancarkan energi frekuensi radio dan, jika tidak dipasang dan digunakan sesuai petunjuk, dapat menyebabkan gangguan yang merugikan komunikasi radio. Bagaimanapun, tidak ada jaminan bahwa gangguan tidak akan terjadi dalam instalasi tertentu. Jika peralatan ini tidak menyebabkan gangguan berbahaya pada penerimaan radio atau televisi,
2016/08/16
Perwakilan Eropa Resmi: Shure Europe GmbH Markas Besar Eropa, Timur Tengah & Afrika Bagian: Persetujuan EMEA Jakob-Dieffenbacher-Str. 12 75031 Eppingen, Germany Telepon: 49-7262-92 49 0 Faks: 49-7262-92 49 11 4 Email:
[email protected] Produk ini memenuhi Persyaratan Utama terhadap semua petunjuk Eropa terkait dan memenuhi syarat untuk penandaan CE. "EU Declaration of Conformity" (Pernyataan Kesesuaian UE) dapat diperoleh dari Shure Incorporated atau sebagian perwakilannya di Eropa. Untuk informasi kontak silahkan kunjungi www.shure.com
17/20
Microflex Advance ANI4OUT Microflex Advance ANI4OUT
Shure Incorporated
Spesifikasi Input (1) RJ45
Output-Output ANI4OUT-XLR
(4) Konektor XLR
ANI4OUT-BLOCK
(4) konektor blok 3-pin
Konfigurasi Impedansi Seimbang
Polaritas Tanpa membalikkan, input ke output
Persyaratan-Persyaratan Daya Power Over Ethernet (PoE), Kelas 0
Pemakaian Daya 10W, maksimum
Berat 663 g (1,5 lbs)
Dimensi HxWxD
4 x 14 x 12,8 cm (1,6 x 5,5 x 5,0 in.)
aplikasi kontrol berbasis Briowser HTML5
Jarak Suhu Kerja −6,7°C (20°F) dengan 40°C (104°F)
Kisaran Suhu Penyimpanan −29°C (-20°F) dengan 74°C (165°F)
Audio Respon Frekuensi 20 dengan 20,000 Hz
Input (Audio Digital Dante) Jumlah Saluran
4
Nilai Sampling
48 kHz
Kedalaman Bit
24
Latensi Does not include Dante latency
0,71 ms
Rentang Dinamik (Dante ke Analog) 20 Hz sampai 20 kHz, Bobot, khas
18/20
2016/08/16
Microflex Advance ANI4OUT Microflex Advance ANI4OUT
Shure Incorporated
117dB
Total Distorsi Selaras @ 1 kHz, -20 dBFS Output, 0dB penguatan analog
<0,05%
Output Tingkat Jepitan Line
+20 dBV
Aux
+0 dBV
Mikrofon
-26 dBV
Tingkat Output Analog
Dapat Dipilih
Line
0dB
Aux
- 20dB
Mikrofon
-46dB
Impedansi Output 150 Ω
Built-in Pemrosesan Sinyal Digital Per Saluran
Equalizer (Parametrik 4-band ), Senyap, Balik Polaritas, Penguatan (140dB jarak)
Sistem
XXXXERROR: [[ Audio Summing ]] DOES NOT EXISTXXXX
Jaringan Persyaratan Kabel Cat 5e atau lebih tinggi (kabel berpelindung direkomendasikan)
IP Ports and Protocols Port
TCP/UDP
Protocol
Description
Factory Default
21
tcp
FTP
Required for firmware updates (otherwise closed)
Closed
22
tcp
SSH
Not supported
Closed
23
tcp
Telnet
Standard console interface
Closed
68
udp
DHCP
Dynamic Host Configuration Protocol
Open
80*
tcp
HTTP
Required to launch embedded web server
Open
427
tcp/udp
SLP†
Required for inter-device communication
Open
443
tcp
HTTPS
Not supported
Closed
161
tcp
SNMP
Not supported
Closed
162
tcp
SNMP
Not supported
Closed
2202
tcp
ASCII
Required for 3rd party control strings
Open
5353
udp
mDNS†
Required for device discovery
Open
5568
udp
SDT†
Required for inter-device communication
Open
8023
tcp
Telnet
Debug console interface
Password
8180*
tcp
HTML
Required for aplikasi web
Open
8427
udp
Multcast SLP†
Required for inter-device communication
Open
64000
tcp
Telnet
Required for Shure firmware update
Open
2016/08/16
19/20
Microflex Advance ANI4OUT Microflex Advance ANI4OUT
Port
TCP/UDP
Protocol
Shure Incorporated
Description
162
udp
SNMP
Used by Dante
[319-320]*
udp
PTP†
Dante clocking
4321, 14336-14600
udp
Dante
Dante audio
[4440, 4444, 4455]*
udp
Dante
Dante audio routing
5353
udp
mDNS†
Used by Dante
[8700-8706, 8800]*
udp
Dante
Dante Control and Monitoring
8751
udp
Dante
Dante Controller
16000-65536
udp
Dante
Used by Dante
01
Aksesoris Bagian Pengganti Hardware kit (XLR model)
90A29254
Hardware kit (block connector model)
90A29252
Mounting Bracket (1/3 rack unit)
53A27742
19" rack tray
CRT1
0
*These ports must be open on the PC or control system to access the device through a firewall.
1
†These protocols require multicast. Ensure multicast has been correctly configured for your network. Shure Incorporated 5800 West Touhy Avenue Niles, IL 60714-4608 USA Phone: +1-847-600-2000 Email:
[email protected]