Project: Saturn Duiven Projectnr: 130583
INHOUD
1 PROJECTGEGEVENS
3
1.1
INLEIDING
3
1.2
PROJECTBESCHRIJVING
3
1.3
GEGEVENS DERDEN
3
1.4
CONSTRUCTIEVE OPBOUW
4
1.5
STABILITEIT
5
1.6
AANVULLENDE GEGEVENS
6
2 BELASTINGEN
7
2.1
CONSTRUCTIEVE ONDERDELEN
7
2.2
SAMENVATTING CONSTRUCTIEVE ONDERDELEN
2.3
GROND + GRONDWATER
12
2.4
OPGELEGDE VERVORMINGEN
12
2.5
OPSLAG VAN GOEDEREN EN MATERIALEN
12
2.6
MACHINES
12
2.7
WINDBELASTING
13
2.8
SNEEUW-/ EN REGENWATERBELASTING
13
2.9
BIJZONDERE BELASTINGEN
13
3 ALGEMENE UITGANGSPUNTEN
11
14
3.1
VAN TOEPASSING ZIJNDE VOORSCHRIFTEN
14
3.2
MATERIALEN
14
3.3
DUURZAAMHEID
14
4 STABILITEIT
15
5 BEREKENING DAKVLOER
18
6 BEREKENING THQ-LIGGERS DAK
27
7 BEREKENING VERDIEPINGSVLOER
42
8 BEREKENING THQ-LIGGERS VERD. VLOER
51
9 BEREKENING HELLINGBAAN
69
10 BELASTINGAFDRACHT FUNDERING
75
BIJLAGEN TECHNOSOFT UITVOER
100-248
Inhoud
V001 - 2 van 248
Project: Saturn Duiven Projectnr: 130583
1
PROJECTGEGEVENS
1.1
INLEIDING In opdracht van Bouwontwikkeling Jongen BV is Aveco de Bondt als hoofdconstructeur betrokken bij het project Saturn te Duiven. In dit eerste rapport worden de uitgangpunten met betrekking tot dit project behandeld. In de verschillende hoofdstukken komen projectomschrijving, aangehouden belastingen, algemene uitgangspunten en randvoorwaarden aan bod. Dit rapport dient als basis voor gewichtsberekening, stabiliteitberekening, wapeningberekeningen en andere noodzakelijke berekeningen. Op basis van deze berekeningen zullen de tekeningen vervaardigd worden. Verder geldt deze berekening ook als uitgangspunt voor door derden te vervaardigen berekeningen van onderdelen en detailberekeningen.
1.2
PROJECTBESCHRIJVING Het winkelpand bestaat uit 2 bouwlagen waarbij het dak wordt gebruikt als parkeerdek. Het parkeerdek is toegankelijk via een hellingbaan welke binnen de bouwmuren van het pand valt. Het gedeelte naast en onder de hellingbaan wordt gebruikt als magazijn en kantoor, het overige gedeelte wordt gebruikt als winkel. Als vloeren is gekozen voor kanaalplaatvloeren met druklaag welke dragen op THQ-Liggers. De belastingafdracht naar de fundering gaat verder via stalen kolommen.
1.3
GEGEVENS DERDEN - Dit document is gebaseerd op de DO-model van de architekt van de datum 17 april 2013. - Grondonderzoek en funderingsadvies volgens rapport 02P00323337-adv-01 d.d. 17-04-2013 van InpijnBlokpoel. - Het peil (bovenzijde afgewerke vloer van de begane grond) is aangenomen op 10,3 m + NAP. Opmerking Uit de sonderingen blijkt dat de draagkrachtige laag een groot verloop in hoogte heeft, om de definitieve paalpuntniveaus te kunnen vaststellen dient er aanvullend onderzoek plaats te vinden. Dit aanvullend ondezoek kan ook invloed hebben op het paaldraagvermogen. In dit rapport wordt uitgegaan van een draagvermogen van 900 kN voor de palen Ø600 en van 270 kN voor de palen van Ø400.
Projectgegevens
V001 - 3 van 248
Project: Saturn Duiven Projectnr: 130583
1.4
CONSTRUCTIEVE OPBOUW ALGEMEEN Als vloeren is gekozen voor kanaalplaatvloeren met druklaag welke dragen op THQ-Liggers. De belastingafdracht naar de fundering gaat verder via stalen kolommen. Het gebouw wordt gefundeerd op funderingsbalken op avegaarpalen. De wanden rondom de liften, str. 2-3/C-D en 6-7/G-H, worden opgebouwd uit kalkzandsteen met een dikte van 214 mm. Alle overige scheidingswanden worden metal studwanden. DILATATIES Het gebouw wordt niet gedilateerd. DAK Het dak wordt hier gebruikt als parkeerdek en zal worden opgebouwd uit kanaalplaten met een dikte van 260 mm welke worden voorzien van een druklaag 50/70 mm. De vloeren dragen af op THQ-liggers welke op stalen kolommen liggen. VERDIEPINGEN De constructieopbouw van de verdiepingen is vergelijkbaar als de dakvloer en bestaat ook uit kanaalplaatvloeren d=260 mm met drukklaag 50/70mm dragend op THQ-liggers. BEGANE GROND Voor de begane grond wordt gekozen voor een onderheide in het werk gestorte vloer op avegaarpalen met een diamater van 400 mm. KELDER Het gebouw bevat geen kelder. FUNDERING De gevels worden gefundereerd op funderingsbalken met daaronder avegaarpalen Ø600 mm, ter plaatse van de stalen kolommen in het gebouw komen 3-paalspoeren met daaronder palen Ø600. Ter plaatse van de liften kommen liftputten, in het werk gestort beton, welke dragen op avegaarpalen Ø400 mm.
Projectgegevens
V001 - 4 van 248
Project: Saturn Duiven Projectnr: 130583
1.5
STABILITEIT De stabiliteit van een gebouw is gewaarborgd indien de windbelasting als horizontale belasting, in combinatie met scheefstand en 2e orde effect, opgenomen kan worden, zie hoofdstuk 4 voor de berekening van de stabiliteit. Dit project is een geschoorde constructie waarbij de vloeren als schijven worden uitgevoerd en de belasting via de windbokken in de gevels naar de fundering brengen.
Om schijfwerking te krijgen dienen de kanaalplaten te worden voorzien van een druklaag en dient er koppelwapening te worden opgenomen. Aan de randen wordt deze koppelwapening verbonden aan de staalconstructie. De koppelwapening in het vloerveld zorgt ervoor de het daadwerkenlijk 1 schijf wordt. De dak- en vloerliggers op de stramien 1, 7, A en H brengen de belasting over naar de windbokken en werken tevens als trekband. De windbokken zitten in de gevels en hebben elk een grootte van ca. 10 x 10 m. De windbokken worden geplaatst op de volgend plaatsen: - op stramien 1, tussen stramien B en D. - op stramien 7, tussen stramien E en F. - op stramien A tussen stramien 1 en 3 en tussen stramien 5 en 7. - op stramien H, tussen stramien 3 en 4.
Projectgegevens
V001 - 5 van 248
Project: Saturn Duiven Projectnr: 130583
1.6
AANVULLENDE GEGEVENS GEBOUWCLASSIFICATIE Gebouwtype: Winkels Gevolgklasse: CC2 Ontwerplevensduur: 50 jaar Gegevens windbelasting: Windgebied III, onbebouwd
BRANDWERENDHEID
(NEN-EN 1990 art. 5.1.4)
Bij dit ontwerp is een brandwerendheid vereist van 60 minuten. Reductie bij geringe aanwezige vuurbelasting is wel mogelijk door het toepassen van een sprinklerinstallatie. Hierdoor blijft een netto eis van 30 minuten over. Bouwconstructie bij brand De brandwerendheidseis geldt voor de bouwconstructie (hoofddraagconstructie volgens de NEN6702). Een gedetailleerde uitleg staat in Bouwen met staal 189 (2006) "Hoofddraagconstructie bij brand in NEN6702 nu duidelijk omschreven" van A.F. Hamerlinck en N.P.M. Scholten. De THO-liggers zijn berekend op een brandwerendheid van 30 minuten. De staalconstructie boven de hellingbaan en onder het parkeerdek dienen brandwerend geschilderd te worden en dienen hiermee een brandwerendheid van 60 minuten te halen. De staalconstructie op het parkeerdek behoort niet tot de bouwconstructie en heeft hierdoor geen brandwerendheidseis. Het overige staal, de kolommen en HEliggers dienen brandwerend geschilderd te worden en dienen een brandwerendheid van 30 minuten te halen. Als alternatie voor het schilderden mag de staalconstructie ook brandwerend worden bekleed. De kanaalplaten inclusief druklaag voldoen aan de brandwerendheideisen.
Bescherming constructie Met het oog op inbraak worden aanvullende maatregelen genomen zoals: - borstwering van beton aan de binnenzijde van de dichte gevel; - aanrijdbeveiligingen buiten het gebouw bij de vliesgevels.
OVERIGE AANDACHTSPUNTEN - Door derden aan te leveren onderdelen worden (steekproefsgewijs) gecontroleerd op constructieve uitgangspunten. Uitgangspunt is dat de volledige verantwoordelijkheid voor de detailberekening bij derden berust. - Steigers en andere onderdelen ten behoeve van de bouw worden in dit rapport niet behandeld. De coördinatie van deze tijdelijke onderdelen ligt bij de aannemer. - Palen dienen afgewapend te worden op een mogelijke misstand van 50mm. Paalafwijkingen meer dan deze 50mm dienen overlegd te worden zodat eventuele voorzieningen aangegeven kunnen worden. - De statische berekening heeft uitsluitend betrekking op de constructie in de eindfase, tenzij anders vermeld.
Projectgegevens
V001 - 6 van 248
Project: Saturn Duiven Projectnr: 130583
2
BELASTINGEN
2.1
CONSTRUCTIEVE ONDERDELEN
Dak parkeren
Blijvende belasting Kanaalplaatvloer d=260 Eigen gewicht
3,80
= 3,80
Druklaag 50/70
0,06
* 25,00 = 1,50
Afwerklaag (asfalt)
0,05
* 25,00 = 1,25
Lichtbeton
0,05
* 10,00 = 0,50
Isolatie en dakbedekking
0,03
= 0,03
Plafond, leidingen, etc.
0,50
= 0,50
Sprinkler
0,12
= 0,12 7,70 kN/m
Totaal blijvende belasting
2
Opgelegde belasting
Roostervloer Techniek
F-garage voertuig<25kN
2,00 kN/m
Reductiefactor
1,00
2
Blijvende belasting Roostervloer Eigen gewicht
0,50
= 0,50
Hekwerk & staal
0,50
= 0,50
Totaal blijvende belasting
1,00 kN/m
2
3,00 kN/m
2
Opgelegde belasting E-industrie Momentaanfactor
Hellingbaan
Ψ0
= 1,00
Ψ1
= 0,90
Ψ2 = 0,80
Blijvende belasting Kanaalplaatvloer d=260 Eigen gewicht
3,80
= 3,80
Druklaag 50/70
0,06
* 25,00 = 1,50
Afwerklaag (asfalt)
0,04
* 25,00 = 1,00
Plafond, leidingen, etc.
0,50
Totaal blijvende belasting
= 0,50 6,80 kN/m
2
2,00 kN/m
2
Opgelegde belasting F-garage voertuig<25kN Momentaanfactor
Ψ0
Belastingen
= 0,70
Ψ1
= 0,70
Ψ2 = 0,60
V001 - 7 van 248
Project: Saturn Duiven Projectnr: 130583
Luifel
Blijvende belasting Staalplaat Eigen gewicht
0,12
= 0,12
Bitumen
0,15
= 0,15
Plafond, leidingen, etc.
0,10
= 0,10
Totaal blijvende belasting
0,37 kN/m
2
0,56 kN/m
2
Opgelegde belasting Sneeuw Momentaanfactor
Verd. vloer magazijn
Ψ0
= 0,00
Ψ1
= 0,20
Ψ2 = 0,00
Blijvende belasting Kanaalplaatvloer d=260 Eigen gewicht
3,80
Druklaag 50/70
0,06
= 3,80
* 25,00 = 1,50
Plafond, leidingen, etc.
0,13
= 0,13
Sprinkler
0,12
= 0,12
Totaal blijvende belasting
5,55 kN/m
2
5,00 kN/m
2
Opgelegde belasting E-opslag winkel Momentaanfactor
Verd. vloer winkel
Ψ0
= 1,00
Ψ1
= 0,90
Ψ2 = 0,80
Blijvende belasting Kanaalplaatvloer d=260 Eigen gewicht
3,80
Druklaag 50/70
0,06
= 3,80
* 25,00 = 1,50
Plafond, leidingen, etc.
0,53
= 0,53
Sprinkler
0,12
= 0,12
Totaal blijvende belasting
5,95 kN/m
2
5,00 kN/m
2
Opgelegde belasting D-winkelruimten warenhuis Momentaanfactor
Ψ0
Belastingen
= 0,40
Ψ1
= 0,70
Ψ2 = 0,60
V001 - 8 van 248
Project: Saturn Duiven Projectnr: 130583
Verd. vloer kantoor
Blijvende belasting Kanaalplaatvloer d=260 Eigen gewicht
3,80
Druklaag 50/70
0,06
= 3,80
* 25,00 = 1,50
Plafond, leidingen, etc.
0,13
= 0,13
Sprinkler
0,12
= 0,12
Totaal blijvende belasting
5,55 kN/m
2
5,00 kN/m
2
Opgelegde belasting B-kantoor Momentaanfactor
Bgg vloer magazijn
Ψ0
= 0,50
Ψ1
= 0,50
Ψ2 = 0,30
Blijvende belasting In het werk gestorte vloer Eigen gewicht
0,20
* 25,00 = 5,00 kN/m
2
5,00 kN/m
2
Opgelegde belasting E-opslag winkel Momentaanfactor
Bgg vloer winkel
Ψ0
= 1,00
Ψ1
= 0,90
Ψ2 = 0,80
Blijvende belasting In het werk gestorte vloer
Opgelegde belasting D-winkelruimten warenhuis Momentaanfactor
Bgg vloer laden/lossen
5,00 kN/m Ψ0
= 0,40
Ψ1
= 0,70
2
Ψ2 = 0,60
Blijvende belasting In het werk gestorte vloer 0,20
Eigen gewicht
* 25,00 = 5,00 kN/m
2
10,00 kN/m
2
Opgelegde belasting E-opslag winkel
Belastingen
V001 - 9 van 248
Project: Saturn Duiven Projectnr: 130583
Trafovloer
Blijvende belasting In het werk gestorte vloer Eigen gewicht
0,25
* 25,00 = 6,25 kN/m
2
5,00 kN/m Ψ2 = 0,60
2
Opgelegde belasting D-winkelruimten warenhuis Ψ0
Momentaanfactor Bostwering dak
= 0,40
Ψ1
= 0,70
Blijvende belasting Eigen gewicht
0,25
= 0,25
staalconstructie (balusters)
0,50
= 0,50
afdekrand
0,25
= 0,25
totaal permanent
Stalen gevel
1,00 kN/m
Blijvende belasting Stalen gevel (binnendoos+buitendoos) Eigen gewicht isolatie reclame
0,25 0,15
= 0,25 = 0,15
0,50
= 0,50
2
0,90 kN/m
2
0,40
= 0,40 kN/m
2
0,72
0,72 kN/m
2
= 0,20
Ψ2 = 0,00
totaal permanent
Pui Eigen gewicht
Windbelasting
Opgelegde belasting Windbelasting Momentaanfactor
Fundering
1,00 Ψ0
* 25,00 = 25,00 kN/m
2
0,15
* 25,00 = 3,75 kN/m
2
0,21
* 20,00 = 4,28 kN/m
2
Blijvende belasting Eigen gewicht
Glazen lift
1,00
Blijvende belasting Eigen gewicht
Kalkzandsteen d=214
Ψ1
Blijvende belasting Eigen gewicht
Bostwering d=150 mm
= 0,00
*
Blijvende belasting Glazen lift Eigen gewicht
1,00
Belastingen
= 1,00 kN/m
2
V001 - 10 van 248
Project: Saturn Duiven Projectnr: 130583
Staal trap
Blijvende belasting Stalen trap Eigen gewicht
1,00
= 1,00 kN/m
2
4,00 kN/m
2
Opgelegde belasting D-winkelruimten ontsluiting Momentaanfactor
Ψ0
Reductiefactor
= 0,40
Ψ1
= 0,70
Ψ2 = 0,60 1,00
Belastingen
V001 - 11 van 248
Project: Saturn Duiven Projectnr: 130583
2.2
SAMENVATTING CONSTRUCTIEVE ONDERDELEN
Omschrijving
PB [kN/m²] [kN/m]
VB [kN/m²]
y0
y1
y2
RED (*)
y0*RED
y1*RED
y2*RED
Dak parkeren
7,70
2,00
0,70
0,70
0,60
1,00
0,70
0,70
0,60
Roostervloer Techniek
1,00
3,00
1,00
0,90
0,80
1,00
1,00
0,90
0,80
Hellingbaan
6,80
2,00
0,70
0,70
0,60
1,00
0,70
0,70
0,60
Luifel
0,37
0,56
0,00
0,20
0,00
1,00
0,00
0,20
0,00
Verd. vloer magazijn
5,55
5,00
1,00
0,90
0,80
1,00
1,00
0,90
0,80
Verd. vloer winkel
5,95
5,00
0,40
0,70
0,60
1,00
0,40
0,70
0,60
Verd. vloer kantoor
5,55
5,00
0,50
0,50
0,30
1,00
0,50
0,50
0,30
Bgg vloer magazijn
5,00
5,00
1,00
0,90
0,80
1,00
1,00
0,90
0,80
Bgg vloer winkel
5,00
5,00
0,40
0,70
0,60
1,00
0,40
0,70
0,60
Bgg vloer laden/lossen
5,00
10,00
1,00
0,90
0,80
1,00
1,00
0,90
0,80
Trafovloer
6,25
5,00
0,40
0,70
0,60
1,00
0,40
0,70
0,60
Bostwering dak
1,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
Stalen gevel
0,90
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
Pui
0,40
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
Windbelasting
0,00
0,72
0,00
0,20
0,00
1,00
0,00
0,20
0,00
25,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
Bostwering d=150 mm
3,75
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
Kalkzandsteen d=214
4,28
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
Glazen lift
1,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
0,00
Staal trap
1,00
4,00
0,40
0,70
0,60
1,00
0,40
0,70
0,60
Fundering
(*) Reductiefactor afhankelijk van ontwerplevensduur
Belastingen.
V001 - 12 van 248
Project: Saturn Duiven Projectnr: 130583
2.3
GROND + GRONDWATER
(NEN-EN 1990 art 4.1.1/4.1.6)
Dit gebouw wordt niet voorzien van een kelder en wordt mede om deze reden niet belast door grond of grondwater.
ZETTINGEN VAN DE GROND In het funderingsadvies is gerekend met negatieve kleef t.g.v. zettingen van de grond ter bepaling van het draagvermogen van de palen. Deze zettinggen geven geen extra belasting op de constructie.
2.4
OPGELEGDE VERVORMINGEN
(NEN-EN 1990 art 4.1.1)
De belastingen uit opgelegde vervormingen worden beschouwd als permanente belastingen. >> Begane grondvloer wordt afgewapend op krimpvervorming. >> Temperatuurverschillen (parkeergarages)
2.5
OPSLAG VAN GOEDEREN EN MATERIALEN
(NEN-EN 1991-1-1 art 6.3)
Buiten de belastingen zoals behandeld in §2.1, hoeft bij dit ontwerp géén rekening gehouden te worden met extra belastingen t.g.v. opslag van goederen en materialen.
2.5
TRILLINGEN DOOR LOPEN, DANSEN EN-/OF SPRINGEN
(NEN-EN 1991-1-1 art. A1.4.4 NB)
Voor vloeren waar veel over gelopen wordt mag de eigenfrequentie niet lager zijn dan 3 Hz. Aan deze eis hoeft niet te worden voldaan als de representatieve waarden van de permanente en momentane belastingen tezamen tenminste 5,0 kN/m2 bedragen. In het geval dat een vloer wordt ondersteund door liggers, geldt dit voor een belasting van tenminste 150 kN per ligger. Alle vloeren in dit gebouw voldoen aan bovengestelde voorwaarden, waardoor trillingen buitenbeschouwing kunnen blijven. 2.6
MACHINES
(NEN-EN 1991-3)
BOUWKRAANBELASTINGEN
De belastingen t.g.v. de bouwkraan moeten opgegeven worden door de aannemer. De consequenties voor de fundering worden niet automatisch verwerkt in de constructieberekeningen. Van de fundering van de bouwkraan kan desgewenst een aparte berekening gemaakt worden. OVERIGE MACHINES Bij dit ontwerp hoeft géén rekening gehouden te worden met belastingen uit overige machines
Belastingen..
V001 - 13 van 248
Project: Saturn Duiven Projectnr: 130583
2.7
WINDBELASTING
(NEN-EN 1991-1-4)
Windgebied
3
Hoogte
12 m
Terreincategorie
I
Diepte
55 m
Lengte
50 m
Benodigde waarden worden per onderdeel bepaald volgens de NEN-EN 1991-1-4. De berekende windbelasting komt terug in de stabiliteitberekening.
2.8
SNEEUW-/ EN REGENWATERBELASTING
(NEN-EN 1991-1-3)
Sneeuw- en regenwater zijn niet maatgevend, vanwege de hogere dakbelasting door het parkeren.
2.9
BIJZONDERE BELASTINGEN AARDBEVINGEN
(NEN-EN 1998-1)
Gezien de locatie in Nederland hoeft géén rekening gehouden te worden met aardbevingen GASEXPLOSIE
(NEN-EN 1991-1-7 art 5)
De verhouding van de CV-ruimte en de ontlastopeningen in de gevel (pui + ramen) geeft de mate van explosiedruk weer. Bij dit project zijn er 2 plaatsen waar de CV's geplaatst worden, de eerste ruimnte is onder de hellingbaan tussen stramien 1-2/D-E en de tweede ruimte is op de verdieping tussen stramien 6-7/A-B. Bij beide ruimten dient een plofluik in de gevel te worden opgenomen.
AANRIJDBELASTING
(NEN-EN 1991-1-7 art 4.3.1)
In parkeergarages en bij een binnenterrein (parkeerplaats) moet voor de hoofddraagconstructie gerekend worden op een botskracht Fdx = 100 kN op een hoogte van 0,5 m boven het rijvlak (tabel 4.1 uit de nationale bijlage van NEN-EN 1991-7). Op de begane grond worden in de dichte gevels een betonnen borstwering met een hoogte van 1 m opgenomen welke de botsbelasting, in geval van een ramkraak, dient op te vangen. Ter plaatse van de entreezone (glazenpui) en de laad- en loszone worden door derden voorzieningen (paaltjes) buiten de constructie geplaatst als bescherming tegen de botsbelasting, in geval van een ramkraak. Aangezien de construcie op het parkeerdek geen deel uit maakt van de hoofddraagconstructie zou hier geen botsbelasting gerekend hoeven te worden. Als hier geen voorziening wordt opgenomen kan theoretisch een auto zo naar beneden rijden, dit is geen veilige situatie waardoor besloten is hier wel een aanrijdbeveiliging aan te brengen maar de botsbelasting te reduceren tot 50% (geen ramkraak).
Belastingen..
V001 - 14 van 248
Project: Saturn Duiven Projectnr: 130583
3
ALGEMENE UITGANGSPUNTEN
3.1
VAN TOEPASSING ZIJNDE VOORSCHRIFTEN EN 1990
Grondslagen van het constructief ontwerp
EN 1991
Belastingen op constructies
EN 1992
Ontwerp en berekening van betonconstructies
EN 1993
Ontwerp en berekening van staalconstructies
EN 1994
Ontwerp en berekening van staal-betonconstructies
EN 1995
Ontwerp en berekening van houtconstructies
EN 1996
Ontwerp en berekening van constructies van metselwerk
EN 1997
Geotechnisch ontwerp
Indien andere normen, voorschriften of richtlijnen van toepassing zijn, wordt hier bij het betreffende onderdeel naar verwezen.
3.2
MATERIALEN Tenzij anders vermeld worden de volgende materiaalkwaliteiten toegepast:
3.3
Beton i.h.w. gestort:
C20/25
Beton prefab:
C55/67
Betonstaal:
B500
Constructiestaal (standaard walsprofielen):
S235
Constructiestaal (gewalste buisprofielen):
S275
Bouten:
8.8
Ankers:
4.6
Constructiehout gezaagd:
C18
Constructiehout gelamineerd: Kalkzandsteen lijmwerk: fk =
GL24h
Kalkzandsteen metselwerk: fk = met mortel M7,5 =
5,0 N/mm²
Baksteen: fk (metselwerk) =
4,4 N/mm²
Voegmortel:
K.50
6,6 N/mm²
DUURZAAMHEID MILIEUKLASSEN BETONCONSTRUCTIES Fundering
XC2
Binnenconstructie
XC1
Parkeerkeldervloer
XC4-XD3-XF2
Buitenconstructie
XC4
Buitenconstructie in aanraking met dooizouten + cloriden
XC4-XD3-XF2
CONSERVERING STAALCONSTRUCTIE Staal buiten: thermisch verzinkt Staal in spouw: thermisch verzinkt Staal binnen: verfsysteem
Uitgangspunten
V001 - 15 van 248
Project: Saturn Duiven Projectnr: 130583
4
STABILITEIT
4.1
ALGEMENE GEGEVENS
Extreme stuwdruk qp Bouwwerkfactor CsCd Gebrek aan correlatie, Ccor
0,715 kN/m² 0,85 0,85
Cpe zone D (druk) Cpe zone E (zuiging) Cpe (wrijving)
0,80 0,50 0,04
Dakopstand verdiepinghoogte
4.2
AANPENDELENDE BELASTING
Dakvloer
verd. [n]
Dak parkeren
Hoogte Diepte Lengte
Oppervlak ²
[m ]
1*(
Grep
11,5 0 53,0 zie 2.10 55,0 art. 7.2.2 (3) 1,5 5,0
m m
Qrep
²
[kN/m ] [kN/m²]
55,0 * 53,0 )*( 7,7 + 2,0 )=
Perm.
Var (M)
[kN]
[kN]
22446 +
4081
+
1749
22446 +
5830
Restant veranderlijke belasting maatgevend niveau Totaal representatief Fd Rekenwaarden Momentane combinatie (yo) Verdiepingvloer
verd. [n]
Oppervlak ²
[m ]
zd
[kN]
[m]
26526,5
1,8
Grep
Qrep
²
[kN/m ] [kN/m²]
Perm.
Var (M)
[kN]
[kN]
Hellingbaan
1*(
53,0 *
6,5 )*( 6,8 + 2,0 )=
2343 +
482
Verd. vloer magazijn
1*(
53,0 *
8,5 )*( 5,6 + 5,0 )=
2500 +
2253
Verd. vloer winkel
1*(
53,0 * 40,0 )*( 6,0 + 5,0 )=
12614 +
4240
+
6567
Restant veranderlijke belasting maatgevend niveau Totaal representatief
17457 + 13542 Fd
Rekenwaarden Momentane combinatie (yo)
zd
[kN]
[m]
24431,7
1,8
(NEN-EN-1993-1-1 art. 5.3.2)
Initiële scheefstand
Φ = Φ0*αh*αm = met
1/200*0,67*0,79 = Φ0 = 1/200 αh = 0,67 αm = 0,79
1 / 379 Fx,1 = Fy,1 = 69,9 kN Fx,2 = Fy,2 = 64,4 kN
stabiliteit
V001 - 16 van 248
Project: Saturn Duiven Projectnr: 130583
4.3
OVERZICHT WINDBELASTING 55 m
Wind in x-richting
53 m
5,0 m
m
WV,y
1,5
WV,y
5,0 m
WV,x
Wind in y-richting
WV,x
Fx,1
Fy,1
1,50 m 5,00 m
Fx,2
n = aantal windbokken n in x-richting = 2
5,00 m
Belasting Fx,1 (per WV)
n in y-richting = 2
Ccor Oppervlak CsCd 1/n 1/2 * 55,0 * 4,0 * 0,85 * 0,85 *
1,30 * 0,715 =
73,9
kN
53,0 * 4,0 * 0,85 * 0,85 *
0,04 * 0,715 =
4,4
kN
Wrijving dak
1/2 * 55,0 * 53,0 * 0,85 * 0,85 *
0,04 * 0,715 =
30,1
kN
Scheefstand
1/2 * 69,9
=
35,0
kN
=
143,3 kN
Druk/zuiging Wrijving gevel
Belasting Fx,2 (per WV)
Fy,2
WV,x
Druk/zuiging
cpe
qp
Frep
1/2 * 55,0 * 5,0 * 0,85 * 0,85 *
1,30 * 0,715 =
92,3
kN
53,0 * 5,0 * 0,85 * 0,85 *
0,04 * 0,715 =
5,5
kN
Wrijving dak
1/2 * 55,0 * 53,0 * 0,85 * 0,85 *
0,04 * 0,715 =
30,1
kN
Scheefstand
1/2 * 64,4
=
32,2
kN
=
160,1 kN
Wrijving gevel
Fx,1
Gevel stramien H
N1
windbok over 2 stramienen
N1
5,0 m
Fx,2 N2
NEd,1 =
152 kN
strip 100x10
NEd,2 =
322 kN
strip 150x12
R1 = R2 = 223 kN
N2
5,0 m Gevel stramien A
5,0 m R1
5,0 m
In deze gevel zijn 2 windbokken over 2 stramien aanwezig, de kracht is de helft van stramien H.
R2
NEd,1 =
76 kN
NEd,2 =
161 kN
strip 80x8 strip 100x10
R1 = R2 = 112 kN
stabiliteit
V001 - 17 van 248
Project: Saturn Duiven Projectnr: 130583
Belasting Fy,1 (per WV)
Ccor Oppervlak CsCd 1/n 1/2 * 53,0 * 4,0 * 0,85 * 0,85 *
1,30 * 0,715 =
71,2
kN
55,0 * 4,0 * 0,85 * 0,85 *
0,04 * 0,715 =
4,5
kN
Wrijving dak
1/2 * 53,0 * 55,0 * 0,85 * 0,85 *
0,04 * 0,715 =
30,1
kN
Scheefstand
1/2 * 69,9
=
35,0
kN
=
140,8 kN
Druk/zuiging Wrijving gevel
Belasting Fy,2 (per WV)
Druk/zuiging
cpe
qp
Frep
1/2 * 53,0 * 5,0 * 0,85 * 0,85 *
1,30 * 0,715 =
89,0
kN
55,0 * 5,0 * 0,85 * 0,85 *
0,04 * 0,715 =
5,7
kN
Wrijving dak
1/2 * 53,0 * 55,0 * 0,85 * 0,85 *
0,04 * 0,715 =
30,1
kN
Scheefstand
1/2 * 64,4
=
32,2
kN
=
157,0 kN
Wrijving gevel
Fy,1 N1
N1
N2
N2
5,0 m
5,0 m
5,0 m
N,Ed1 =
149 kN
strip 100x8
NEd,2 =
316 kN
strip 120x12
Fy,2 R1 = R2 = 219 kN 5,0 m aantal stramienen R1 4.4
2
R2
SCHIJFWERKING
Zoals beschreven in §1.5 dienen de vloeren te werken als schijven om de belasting naar de windbokken te krijgen. De windbokken dienen bij voorkeur op plaatsen te zitten waar ze direct op de vloeren aansluiten voor een zo efficient mogelijke inleiding van de krachten.
stabiliteit
V001 - 18 van 248
berekening dak
V001 - 19 van 248
berekening dak
V001 - 20 van 248
berekening dak
V001 - 21 van 248
berekening dak
V001 - 22 van 248
berekening dak
V001 - 23 van 248
berekening dak
V001 - 25 van 248
Project: Saturn Duiven Projectnr: 130583
5.10
MIDDEN KOLOMMEN
Belasting F1
verd.
Perm.
Var (M)
[kN/m ] [kN/m²]
[kN]
[kN]
1,0 )*( 648 + 184 )=
648,0 +
128,8
+
55,2
[m ]
1*(
Qrep
²
²
[n] dakligger str. 4-6
Grep
Oppervlak
Restant veranderlijke belasting maatgevend niveau Totaal representatief
648,0 + 184,0
Kolom met puntlast en moment
NEN-EN 1993-1-1 §6.3.2
Schema
5,00 m Grep + Qrep = rekenwaarde
Gegevens: Hoogte =
F M
h
Puntlast = Boven Moment My = Onder Moment My =
648 +
Boven Moment Mz = Onder Moment Mz = Profiel:
184 = 1068 kN
0+
0=
0 kNm
0+
0=
0 kNm
0+
0=
0 kNm
0+
0=
0 kNm
HE240A
Sterke as
Doorsn.klasse 1 cY = 0,87 (knikkromme b)
M
Uiterste grenstoestand
NRk =
LET OP RICHTING MOMENT
cZ
= 0,60
(knikkromme c)
Staalkwaliteit S 235 kyy = 0,736 kzy = 0,442
cLT
= 0,83
(kipkromme a)
kyz
=
0,771
kzz
=
1,284
A * fy =
7680 * 235.E-3 =
1805 kN
My;Rk = Wy;pl * fy =
744,6.E3 * 235.E-6 = 175 kNm
Mz;Rk = Wz;pl * fy =
351,7.E3 * 235.E-6 = 83 kNm
(6.61) UC1 = NEd / cyNRk / gM1 + kyy My;Ed / cLTMy;Rk / gM1 + kyz Mz;Ed / Mz;Rk / gM1 =
0,68
(6.62) UC2 = NEd / czNRk / gM1 + kzy My;Ed / cLTMy;Rk / gM1 + kzz Mz;Ed / Mz;Rk / gM1 =
0,98
berekening dak
V001 - 26 van 248
Project: Saturn Duiven Projectnr: 130583
5.11
KOLOMMEN STRAMIEN 2
Belasting F1
verd.
Perm.
Var (M)
[kN]
[kN]
[kN/m ] [kN/m²]
[m ]
1*(
Qrep
²
²
[n] dakligger str. 2
Grep
Oppervlak
1,0 )*( 604 + 162 )=
604 +
113
+
49
604 +
162
Restant veranderlijke belasting maatgevend niveau Totaal representatief Kolom met puntlast en moment
NEN-EN 1993-1-1 §6.3.2
Schema
5,00 m Grep + Qrep = rekenwaarde
Gegevens: Hoogte =
F M
h
Puntlast = Boven Moment My = Onder Moment My =
604
+
162 =
0
+
0=
0 kNm
0
+
0=
0 kNm
Boven Moment Mz = Onder Moment Mz =
0
+
0=
0 kNm
0
+
0=
0 kNm
Profiel:
HE240A
Uiterste grenstoestand
NRk =
LET OP RICHTING MOMENT
Sterke as
Doorsn.klasse 1 cY = 0,87 (knikkromme b)
M
986 kN
cZ
= 0,60
(knikkromme c)
Staalkwaliteit S 235 kyy = 0,726 kzy = 0,000
cLT
= 0,83
(kipkromme a)
kyz
=
0,739
kzz
=
1,231
A * fy =
7680 * 235.E-3 =
1805 kN
My;Rk = Wy;pl * fy =
744,6.E3 * 235.E-6 = 175 kNm
Mz;Rk = Wz;pl * fy =
351,7.E3 * 235.E-6 = 83 kNm
(6.61) UC1 = NEd / cyNRk / gM1 + kyy My;Ed / cLTMy;Rk / gM1 + kyz Mz;Ed / Mz;Rk / gM1 =
0,63
(6.62) UC2 = NEd / czNRk / gM1 + kzy My;Ed / cLTMy;Rk / gM1 + kzz Mz;Ed / Mz;Rk / gM1 =
0,90
berekening dak
V001 - 27 van 248
vloer 2 vloer 1
THQ-liggers DAK
V001 - 28 van 248
4
1
2
3 SFB-ligger 3
1
THQ-liggers DAK
2 THQ-ligger
V001 - 29 van 248
Project: Saturn Duiven Projectnr: 130583
Optredende belasting
rep
per meter balk
mom
rekenw.
wringing ey [mm]
[kN/m] [kN/m] [kN/m]
eigen gewicht ligger 2
1,4
1,4
0
e.g.
7,70 kN/m x
3,50
m
27,0
27,0
226
vloer 2
e.g.
2 7,70 kN/m x
4,00
m
30,8
30,8
-226
vloer 1
v.b.
3,50
m
7,0
4,2
7,0
226
vloer 2
v.b.
4,00
m
0,0
0,0
0,0
-226
66,1
11
vloer 1
2 2,00 kN/m x 2 0,00 kN/m x
66,1 Md (brand)
Momenten en dwarskrachten Steunpuntsmoment
(volgt uit technosoft-berekening)
Veldmoment MTd =
Wringend moment Dwarskracht t.p.v. steunpunt Dimensies hoedligger bovenplaat
d
h
zo
mm
mm
mm
300
20
275
Mrep
402 kNm
441 kNm
229 kNm
256 kNm
3,1 kNm
Vd =
293 kN
Bepaling doorsnedeklasse e (tabel 5.2 eurocode 3) 0,81
Klasse
lijfplaat links
6
274
15
b/t flens
7,9
2
lijfplaat rechts
6
274
15
b/t inwendige flens
20,0
1
550
15
0
b/t lijf
43,3
1
onderplaat
Doorsnedeklasse profiel
2
verschil bovenkant bovenplaat en bovenkant lijfplaat = 6 mm nuttige hoogte ligger = 280 mm = hoogte ligger zonder onderflens opleglengte vloer = 109 mm Profielgrootheden
oppervlak doorsnede zy elastisch onder =
³ 18 x10 mm²
130 mm 6
boven =
290 x10 mm
Iy
³ 2242 x10 mm³
elastisch
Wy;el
plastisch
Wy;pl
³ 2145 x10 mm³
plastisch incl red. dwarskracht
Wy;pl
³ 2048 x10 mm³
WTy
³ 2480 x10 mm³
Toetsing
165 mm
4
onder =
Moment elastisch (zonder reductie dwarskracht)
boven =
³ 1755 x10 mm³
229 N/mm²
u.c. = 0,94
62 N/mm²
u.c. = 0,25
Dwarskracht + wringing 89,1 + 1,3 = 90,4 N/mm² Combinatie moment + dwarskracht √(sx² + sy² - sxsy + 3tx² + 3ty²) ≤ fy;d
u.c. = 0,64 u.c. = 0,84
Moment plastisch (met reductie dwarskracht + wringing)
196 N/mm²
u.c. = 0,80
Buiging ligger + onderflens (plastisch)
212 N/mm²
u.c. = 0,86
Moment onderflens t.g.v. oplegging vloer
THQ-liggers DAK
V001 - 30 van 248
vloer 2 vloer 1
THQ-liggers DAK
V001 - 31 van 248
4
1
2
3 SFB-ligger 3
1
THQ-liggers DAK
2 THQ-ligger
V001 - 32 van 248
Project: Saturn Duiven Projectnr: 130583
Optredende belasting
rep
per meter balk
mom
rekenw.
wringing ey [mm]
[kN/m] [kN/m] [kN/m]
eigen gewicht ligger 2
1,7
1,7
0
e.g.
7,70 kN/m x
4,10
m
31,6
31,6
226
vloer 2
e.g.
2 7,70 kN/m x
3,40
m
26,2
26,2
-226
vloer 1
v.b.
4,10
m
8,2
4,9
8,2
226
vloer 2
v.b.
3,40
m
0,0
0,0
0,0
-226
67,7
45
vloer 1
2 2,00 kN/m x 2 0,00 kN/m x
67,7 Md (brand)
Momenten en dwarskrachten Steunpuntsmoment
(volgt uit technosoft-berekening)
Veldmoment Wringend moment
Dimensies hoedligger bovenplaat
d
h
zo
mm
mm
mm
300
25
275
575 kNm
631 kNm
391 kNm
435 kNm
MTd =
16,4 kNm
Vd =
362 kN
Dwarskracht t.p.v. steunpunt
Mrep
Bepaling doorsnedeklasse e (tabel 5.2 eurocode 3) 0,81
Klasse
lijfplaat links
6
274
20
b/t flens
6,0
1
lijfplaat rechts
6
274
20
b/t inwendige flens
15,0
1
550
20
0
b/t lijf
42,5
1
onderplaat
Doorsnedeklasse profiel
1
verschil bovenkant bovenplaat en bovenkant lijfplaat = 6 mm nuttige hoogte ligger = 280 mm = hoogte ligger zonder onderflens opleglengte vloer = 109 mm Profielgrootheden
oppervlak doorsnede zy elastisch onder =
³ 22 x10 mm²
128 mm 6
boven =
368 x10 mm
Iy
³ 2882 x10 mm³
elastisch
Wy;el
plastisch
Wy;pl
³ 2693 x10 mm³
plastisch incl red. dwarskracht
Wy;pl
³ 2554 x10 mm³
WTy
³ 3070 x10 mm³
Toetsing
172 mm
4
onder =
Moment elastisch (zonder reductie dwarskracht)
boven =
³ 2136 x10 mm³
269 N/mm²
u.c. = 0,93
41 N/mm²
u.c. = 0,14
Dwarskracht + wringing 110,1 + 5,3 = 115,4 N/mm² Combinatie moment + dwarskracht √(sx² + sy² - sxsy + 3tx² + 3ty²) ≤ fy;d
u.c. = 0,69 u.c. = 0,87
Moment plastisch (met reductie dwarskracht + wringing)
225 N/mm²
u.c. = 0,78
Buiging ligger + onderflens (plastisch)
239 N/mm²
u.c. = 0,82
Moment onderflens t.g.v. oplegging vloer
THQ-liggers DAK
V001 - 33 van 248
vloer 2 vloer 1
THQ-liggers DAK
V001 - 34 van 248
vloer 2 vloer 1
THQ-liggers DAK
V001 - 35 van 248
4
1
2
3 SFB-ligger 3
1
THQ-liggers DAK
2 THQ-ligger
V001 - 37 van 248
Project: Saturn Duiven Projectnr: 130583
Md (brand)
Momenten en dwarskrachten (volgt uit technosoft-berekening)
Steunpuntsmoment
458 kNm
510 kNm
Veldmoment
260 kNm
292 kNm
Wringend moment
MTd =
-16,7 kNm
Vd =
337 kN
Dwarskracht t.p.v. steunpunt Dimensies hoedligger bovenplaat lijfplaat links lijfplaat rechts onderplaat
Mrep
d
h
zo
mm
mm
mm
300
20
275
b/t flens
7,9
2
6
274
15
b/t inwendige flens
20,0
1
6
274
15
b/t lijf
43,3
550
15
0
Doorsnedeklasse profiel
Bepaling doorsnedeklasse e (tabel 5.2 eurocode 3) 0,81
Klasse
1 2
verschil bovenkant bovenplaat en bovenkant lijfplaat = 6 mm nuttige hoogte ligger = 280 mm = hoogte ligger zonder onderflens opleglengte vloer = 109 mm Profielgrootheden
oppervlak doorsnede zy elastisch onder =
³ 18 x10 mm²
130 mm 6
boven =
290 x10 mm
Iy
³ 2242 x10 mm³
elastisch
Wy;el
plastisch
Wy;pl
³ 2145 x10 mm³
plastisch incl red. dwarskracht
Wy;pl
³ 1974 x10 mm³
WTy
³ 2480 x10 mm³
Toetsing
165 mm
4
onder =
Moment elastisch (zonder reductie dwarskracht)
boven =
³ 1755 x10 mm³
261 N/mm²
u.c. = 1,07
89 N/mm²
u.c. = 0,36
Dwarskracht + wringing 102,5 + 6,7 = 109,2 N/mm² Combinatie moment + dwarskracht √(sx² + sy² - sxsy + 3tx² + 3ty²) ≤ fy;d
u.c. = 0,94
Moment plastisch (met reductie dwarskracht + wringing)
232 N/mm²
u.c. = 0,95
Buiging ligger + onderflens (plastisch)
265 N/mm²
u.c. = 1,08
Moment onderflens t.g.v. oplegging vloer
THQ-liggers DAK
u.c. = 0,77
V001 - 38 van 248
Project: Saturn Duiven Projectnr: 130583
6.8
DAKLIGGERS STR. 4-5 - VOLBELAST vloer 2 vloer 1
Staalkwaliteit S355 6.10(a) 1,2 PB + 1,5 VB y0 = 0,7 y1 = 0,7 y2 = 0,6 6.10(b) 1,35 PB + 1,5 Ψ1 VB (extreem met schaakbordbelasting, momentaan zonder schaakbordbelasting) Toetsing: extreem Optredende belasting
rep
per meter balk 2
7,70 kN/m x
e.g.
vloer 2
e.g.
vloer 1
v.b.
vloer 2
v.b.
rekenw.
2
7,70 kN/m x 2 2,00 kN/m x 2 2,00 kN/m x
1,7
2,3
0
5,00
m
38,5
52,0
-122
5,00
m
38,5
52,0
122
5,00
m
10,0
7,0
10,5
-122
5,00
m
10,0
7,0
10,5
122
127,3
0
98,7 Md
Momenten en dwarskrachten (volgt uit technosoft-berekening)
738,0 kNm
578,0 kNm
Veldmoment
423,0 kNm
329,0 kNm
MTd =
Dwarskracht t.p.v. steunpunt
bovenplaat
Mrep
Steunpuntsmoment Wringend moment
Dimensies hoedligger
wringing ey [mm]
[kN/m] [kN/m] [kN/m]
eigen gewicht ligger vloer 1
mom
d
h
onderzijde
mm
mm
mm
300
25
275
0,0 kNm
Vd =
536 kN
Bepaling doorsnedeklasse e (tabel 5.2 eurocode 3) 0,81
Klasse
lijfplaat links
6
274
20
b/t flens
6,0
1
lijfplaat rechts
6
274
20
b/t inwendige flens
15,0
1
550
20
0
b/t lijf
42,5
onderplaat
1
Doorsnedeklasse profiel
1
verschil bovenkant bovenplaat en bovenkant lijfplaat = 6 mm nuttige hoogte ligger = 280 mm = hoogte ligger zonder onderflens opleglengte vloer = 99 mm Profielgrootheden
³ 22 x10 mm²
oppervlak doorsnede elastisch
zy
onder =
128 mm
boven =
172 mm
6 4 368 x10 mm
Iy
³ 2882 x10 mm³
elastisch
Wy;el
plastisch
Wy;pl
³ 2693 x10 mm³
plastisch incl red. dwarskracht
Wy;pl
³ 2551 x10 mm³
WTy
³ 3070 x10 mm³
onder =
THQ-liggers DAK
boven =
³ 2136 x10 mm³
V001 - 39 van 248
THQ-liggers DAK
V001 - 40 van 248
vloer 2 vloer 1
THQ-liggers DAK
V001 - 41 van 248
Project: Saturn Duiven Projectnr: 130583
Toetsing
Veldmoment elastisch (zonder reductie dwarskracht)
194 N/mm²
u.c. = 0,55
Steunpuntsmoment elastisch (zonder reductie dwarskracht)
339 N/mm²
u.c. = 0,96
69 N/mm²
u.c. = 0,19
Moment onderflens t.g.v. oplegging vloer
Dwarskracht + wringing 160,9 + 0,0 = 160,9 N/mm² Combinatie st.pnt.moment + dwarskracht √(sx² + sy² - sxsy + 3tx² + 3ty²) ≤ fy;d
u.c. = 0,78 u.c. = 0,88
Bovenmoment plastisch (met reductie dwarskracht + wringing)
284 N/mm²
u.c. = 0,80
Buiging ligger (bovenmoment) + onderflens (plastisch)
299 N/mm²
u.c. = 0,84
Buiging ligger (ondermoment) + onderflens (plastisch)
171 N/mm²
u.c. = 0,48
Doorbuiging Ueind =
27,60
0,003 L
Ubij =
18,80
0,002 L
Met een onderflens met een dikte van 20 mm is brand niet maatgevenend.
THQ-liggers DAK
V001 - 42 van 248
berekening verd
V001 - 43 van 248
berekening verd
V001 - 44 van 248
berekening verd
V001 - 45 van 248
berekening verd
V001 - 46 van 248
berekening verd
V001 - 47 van 248
berekening verd
V001 - 48 van 248
berekening verd
V001 - 49 van 248
berekening verd
V001 - 51 van 248
vloer 2 vloer 1
THQ-liggers VERD
V001 - 52 van 248
3
1
2 IFB-ligger
4
1
2
3 SFB-ligger 3
1
THQ-liggers VERD
2 THQ-ligger
V001 - 53 van 248
THQ-liggers VERD
V001 - 54 van 248
vloer 2 vloer 1
THQ-liggers VERD
V001 - 55 van 248
3
1
2 IFB-ligger
4
1
2
3 SFB-ligger 3
1
THQ-liggers VERD
2 THQ-ligger
V001 - 57 van 248
THQ-liggers VERD
V001 - 58 van 248
Project: Saturn Duiven Projectnr: 130583
Toetsing
Moment elastisch (zonder reductie dwarskracht)
214 N/mm²
u.c. = 0,88
Moment onderflens t.g.v. oplegging vloer
8.5
68 N/mm²
u.c. = 0,28
Dwarskracht + wringing 58,7 + 16,8 = 75,5 N/mm² Combinatie moment + dwarskracht √(sx² + sy² - sxsy + 3tx² + 3ty²) ≤ fy;d
u.c. = 0,53 u.c. = 0,78
Moment plastisch (met reductie dwarskracht + wringing)
189 N/mm²
u.c. = 0,77
Buiging ligger + onderflens (plastisch)
223 N/mm²
u.c. = 0,91
VLOERLIGGER STR. 3 - VOL BELAST vloer 2 vloer 1
Staalkwaliteit S355 6.10(a) 1,2 PB + 1,5 VB y0 = 1 y1 = 0,9 y2 = 0,8 6.10(b) 1,35 PB + 1,5 Ψ1 VB (extreem met schaakbordbelasting, momentaan zonder schaakbordbelasting) Toetsing: extreem Optredende belasting
rep
per meter balk 2
5,55 kN/m x
e.g.
vloer 2
e.g.
vloer 1
v.b.
vloer 2
v.b.
rekenw.
2
5,95 kN/m x 2 5,00 kN/m x 2 5,00 kN/m x
1,8
2,5
0
4,00
m
22,2
30,0
-122
5,00
m
29,8
40,2
122
4,00
m
20,0
18,0
27,0
-122
5,00
m
25,0
22,5
33,8
122
133,4
15
98,8 Md
Momenten en dwarskrachten Steunpuntsmoment
(volgt uit technosoft-berekening)
Veldmoment Dwarskracht t.p.v. steunpunt d
h
onderzijde
mm
mm
mm
608,0 kNm
546,0 kNm
379,0 kNm
9,4 kNm
Vd =
610 kN
300
30
270
Bepaling doorsnedeklasse e (tabel 5.2 eurocode 3) 0,81
lijfplaat links
6
274
20
b/t flens
lijfplaat rechts
6
274
20
550
20
0
bovenplaat
onderplaat
Mrep
869,0 kNm MTd =
Wringend moment
Dimensies hoedligger
wringing ey [mm]
[kN/m] [kN/m] [kN/m]
eigen gewicht ligger vloer 1
mom
Klasse
6,0
1
b/t inwendige flens
15,0
1
b/t lijf
41,7
Doorsnedeklasse profiel
1 1
voldoet verschil bovenkant bovenplaat en bovenkant lijfplaat = 6 mm nuttige hoogte ligger = 280 mm = hoogte ligger zonder onderflens opleglengte vloer = 99 mm
THQ-liggers VERD
V001 - 59 van 248
vloer 2 vloer 1
THQ-liggers VERD
V001 - 60 van 248
3
1
2 IFB-ligger
4
1
2
3 SFB-ligger 3
1
THQ-liggers VERD
2 THQ-ligger
V001 - 62 van 248
THQ-liggers VERD
V001 - 63 van 248
vloer 2 vloer 1
THQ-liggers VERD
V001 - 64 van 248
vloer 2 vloer 1
THQ-liggers VERD
V001 - 65 van 248
3
1
2 IFB-ligger
4
1
2
3 SFB-ligger 3
1
THQ-liggers VERD
2 THQ-ligger
V001 - 67 van 248
THQ-liggers VERD
V001 - 68 van 248
Project: Saturn Duiven Projectnr: 130583
Toetsing
Moment elastisch (zonder reductie dwarskracht) Moment onderflens t.g.v. oplegging vloer
225 N/mm²
u.c. = 0,78
59 N/mm²
u.c. = 0,20
Dwarskracht + wringing 118,6 + 0,0 = 118,6 N/mm² Combinatie moment + dwarskracht √(sx² + sy² - sxsy + 3tx² + 3ty²) ≤ fy;d
u.c. = 0,71 u.c. = 0,70
Moment plastisch (met reductie dwarskracht + wringing)
195 N/mm²
u.c. = 0,67
Buiging ligger + onderflens (plastisch)
207 N/mm²
u.c. = 0,71
THQ-liggers VERD
V001 - 69 van 248
Hellingbaan
V001 - 70 van 248
Hellingbaan
V001 - 71 van 248
Hellingbaan
V001 - 72 van 248
Hellingbaan
V001 - 73 van 248
Hellingbaan
V001 - 75 van 248
Project: Saturn Duiven Projectnr: 130583
10
BELASTINGAFDRACHT FUNDERING
Berekening funderingsbalken volgens technosoft pagina 224 - 248. 10.1
STRAMIEN 1
Belastingen q1 Lengte last:
17,90 m
Afstand tot referentie:
0,00 m aantal verd. [n]
Verhoging verandelijke belasting i.v.m.
0%
belastingschikking (enkel op maatgevende verdieping) Hoogte/Breedte links
Permanent
rechts
[m]
Grep
Qrep
²
links ²
[kN/m ] [kN/m ]
[m]
Veranderlijk (Mom)
rechts
¹
¹
[kN/m ] [kN/m ]
links ¹
[kN/m ]
rechts [kN/m¹]
Bostwering d=150 mm
1*(
0,5 ) (
3,0 )*( 3,8 + 0,0 )=
1,9
11,3
0,0
0,0
Pui
1*(
1,0 ) (
1,0 )*( 0,4 + 0,0 )=
0,4
0,4
0,0
0,0
0,0
0,0
0,0
0,0
Restant veranderlijke belasting maatgevend niveau
+
Totaal representatief
2,3
11,7
q2 Lengte last:
32,40 m
Verhoging verandelijke belasting i.v.m.
Afstand tot referentie:
17,90 m
belastingschikking (enkel op maatgevende verdieping)
aantal verd. [n] Bostwering d=150 mm
Hoogte/Breedte links
1*(
Bgg vloer magazijn
1*(
Grep
Qrep
²
links ²
[kN/m ] [kN/m ]
[m]
1*(
Pui
Permanent
rechts
[m]
0% Veranderlijk (Mom)
rechts
¹
¹
links
rechts
[kN/m ]
[kN/m¹]
5,6
0,0
0,0
[kN/m ] [kN/m ]
¹
1,5 ) (
1,5 )*( 3,8 + 0,0 )=
5,6
12,0 ) (
1,0 )*( 0,4 + 0,0 )=
4,8
0,4
0,0
0,0
4,7 )*( 5,0 + 5,0 )=
8,8
11,6
8,8
11,6
0,0
0,0
8,8
11,6
0,5 *
3,5 ) ( 0,5 *
Restant veranderlijke belasting maatgevend niveau
+
Totaal representatief
19,2
17,7
q3 Lengte last:
4,70 m
Verhoging verandelijke belasting i.v.m.
Afstand tot referentie:
50,30 m
belastingschikking (enkel op maatgevende verdieping)
aantal verd. [n] Pui
1*(
Bgg vloer magazijn
1*(
Hoogte/Breedte links
[m] 15,5 ) (
0,4 *
Permanent
rechts
[m]
4,7 ) ( 0,4 *
0%
Grep
Qrep
²
links ²
Veranderlijk (Mom)
rechts
¹
¹
15,5 )*( 0,4 + 0,0 )=
6,2
4,7 )*( 5,0 + 5,0 )=
[kN/m ] [kN/m ]
Restant veranderlijke belasting maatgevend niveau Totaal representatief
belastingafdracht fundering
links
rechts
[kN/m ]
[kN/m¹]
6,2
0,0
0,0
9,3
9,3
9,3
9,3
0,0
0,0
15,5
15,5
9,3
9,3
[kN/m ] [kN/m ]
+
¹
V001 - 76 van 248
Project: Saturn Duiven Projectnr: 130583
F1 verd. [n] Hellingbaan
Oppervlak ²
[m ]
1*(
Grep
Qrep
[kN/m²] [kN/m²] 1,0 )*( 38
+
13 )=
Perm.
Var (M)
[kN]
[kN]
38,0 +
9,1
+
3,9
38,0 +
13,0
Restant veranderlijke belasting maatgevend niveau Totaal representatief F2 verd. [n]
Oppervlak ²
[m ]
Grep
Qrep
²
[kN/m ] [kN/m²]
Perm.
Var (M)
[kN]
[kN]
Dak parkeren
1*(
1,0 )*( 127 +
32 )=
127,0 +
22,7
Verd. vloer kantoor
1*(
1,0 )*( 108 +
81 )=
108,0 +
40,5
Hellingbaan
1*(
1,0 )*( 119 +
37 )=
119,0 +
25,8
dakligger str H
1*(
1,0 )*( 18,0 + 3,0 )=
18,0 +
2,1
vloerligger str H
1*(
1,0 )*( 22,0 + 7,0 )=
22,0 +
7,0
+
51,6
Restant veranderlijke belasting maatgevend niveau Totaal representatief
394,0 + 149,7
F3 verd. [n]
Oppervlak ²
[m ]
Grep
Qrep
²
²
[kN/m ] [kN/m ]
Perm.
Var (M)
[kN]
[kN]
Dak parkeren
1*(
1,0 )*( 134 +
40 )=
134,0 +
28,0
Verd. vloer kantoor
1*(
1,0 )*( 108 +
98 )=
108,0 +
49,0
Hellingbaan
1*(
1,0 )*( 116 +
39 )=
116,0 +
27,3
+
61,0
Restant veranderlijke belasting maatgevend niveau Totaal representatief
358,0 + 165,3
F4 verd. [n]
Oppervlak ²
[m ]
Grep
Qrep
²
²
[kN/m ] [kN/m ]
Perm.
Var (M)
[kN]
[kN]
Dak parkeren
1*(
1,0 )*( 132 +
40 )=
132,0 +
28,0
Verd. vloer kantoor
1*(
1,0 )*( 130 + 101 )=
130,0 +
50,5
Hellingbaan
1*(
1,0 )*( 108 +
108,0 +
28,7
+
62,8
41 )=
Restant veranderlijke belasting maatgevend niveau Totaal representatief
370,0 + 170,0
F5 verd. [n]
Oppervlak ²
[m ]
Grep
Qrep
²
[kN/m ] [kN/m²]
Perm.
Var (M)
[kN]
[kN]
Dak parkeren
1*(
1,0 )*( 145 +
42 )=
145,0 +
29,4
Verd. vloer kantoor
1*(
1,0 )*( 45
+
37 )=
45,0 +
18,5
Hellingbaan
1*(
1,0 )*( 131 +
46 )=
131,0 +
32,2
+
32,3
Restant veranderlijke belasting maatgevend niveau Totaal representatief
321,0 + 112,4
belastingafdracht fundering
V001 - 77 van 248
Project: Saturn Duiven Projectnr: 130583
F6 verd. [n]
Oppervlak ²
[m ]
Grep
Qrep
[kN/m²] [kN/m²]
Perm.
Var (M)
[kN]
[kN]
Dak parkeren
1*(
1,0 )*( 156 +
44 )=
156,0 +
30,8
Hellingbaan
1*(
1,0 )*( 127 +
42 )=
127,0 +
29,4
+
25,8
283,0 +
86,0
Restant veranderlijke belasting maatgevend niveau Totaal representatief F7 verd. [n]
Oppervlak ²
[m ]
Grep
Qrep
²
²
[kN/m ] [kN/m ]
Perm.
Var (M)
[kN]
[kN] 31,5
Dak parkeren
1*(
1,0 )*( 158 +
45 )=
158,0 +
Hellingbaan
1*(
1,0 )*( 134 +
44 )=
134,0 +
30,8
+
26,7
292,0 +
89,0
Restant veranderlijke belasting maatgevend niveau Totaal representatief F8 verd. [n]
Oppervlak ²
[m ]
Grep
Qrep
²
²
[kN/m ] [kN/m ]
Perm.
Var (M)
[kN]
[kN]
Dak parkeren
1*(
1,0 )*( 163 +
47 )=
163,0 +
32,9
Hellingbaan
1*(
1,0 )*( 137 +
46 )=
137,0 +
32,2
+
27,9
300,0 +
93,0
Restant veranderlijke belasting maatgevend niveau Totaal representatief F9 verd. [n]
Oppervlak ²
[m ]
Grep
Qrep
²
[kN/m ] [kN/m²]
Perm.
Var (M)
[kN]
[kN]
Dak parkeren
1*(
1,0 )*( 175 +
48 )=
175,0 +
33,6
Hellingbaan
1*(
1,0 )*( 148 +
48 )=
148,0 +
33,6
Restant veranderlijke belasting maatgevend niveau
+
28,8
323,0 +
96,0
WINDBELASTING ±
223,4
Totaal representatief
F10 verd. [n]
Oppervlak ²
[m ]
Grep
Qrep
²
[kN/m ] [kN/m²]
Perm.
Var (M)
[kN]
[kN]
Dak parkeren
1*(
1,0 )*( 165 +
46 )=
165,0 +
32,2
Hellingbaan
1*(
1,0 )*( 140 +
46 )=
140,0 +
32,2
+
27,6
305,0 +
92,0
Restant veranderlijke belasting maatgevend niveau Totaal representatief
belastingafdracht fundering
V001 - 78 van 248
Project: Saturn Duiven Projectnr: 130583
F11 verd. [n]
Oppervlak ²
[m ]
Grep
Qrep
[kN/m²] [kN/m²]
Perm.
Var (M)
[kN]
[kN]
Dak parkeren
1*(
1,0 )*( 88
+
31 )=
88,0 +
21,7
Hellingbaan
1*(
1,0 )*( 75
+
31 )=
75,0 +
21,7
+
18,6
Restant veranderlijke belasting maatgevend niveau Totaal representatief
163,0 +
62,0
WINDBELASTING ±
223,4
F12 verd. [n]
Oppervlak ²
[m ]
Grep
Qrep
²
²
[kN/m ] [kN/m ]
Perm.
Var (M)
[kN]
[kN] 14,7
Dak parkeren
1*(
1,0 )*( 77
+
21 )=
77,0 +
Hellingbaan
1*(
1,0 )*( 62
+
21 )=
62,0 +
14,7
+
12,6
139,0 +
42,0
Restant veranderlijke belasting maatgevend niveau Totaal representatief F13 verd. [n]
Oppervlak ²
[m ]
Grep
Qrep
²
²
[kN/m ] [kN/m ]
Perm.
Var (M)
[kN]
[kN]
Dak parkeren
1*(
1,0 )*( 14
+
3
)=
14,0 +
2,1
Hellingbaan
1*(
1,0 )*( 10
+
3
)=
10,0 +
2,1
dakligger str. A
1*(
1,0 )*( 11,0 + 4,0 )=
11,0 +
2,8
hellingbaan str. A
1*(
1,0 )*( 7,0 + 4,0 )=
7,0 +
4,0
+
2,1
42,0 +
13,1
Restant veranderlijke belasting maatgevend niveau Totaal representatief
belastingafdracht fundering
V001 - 79 van 248
Project: Saturn Duiven Projectnr: 130583
10.2
STRAMIEN 2
Belastingen q1 Lengte last:
16,50 m
Verhoging verandelijke belasting i.v.m.
Afstand tot referentie:
0,00 m
belastingschikking (enkel op maatgevende verdieping)
aantal verd. [n] Pui
1*(
Bgg vloer magazijn
1*(
Hoogte/Breedte links
[m] 12,0 ) (
0,5 *
Permanent
rechts
[m]
4,0 ) ( 0,5 *
0%
Grep
Qrep
²
links ²
[kN/m ] [kN/m ]
¹
¹
4,8
4,0 )*( 5,0 + 5,0 )=
10,0 14,8
4,8
0,0
0,0
10,0
10,0
10,0
0,0
0,0
10,0
10,0
14,8
¹
rechts [kN/m¹]
+
Totaal representatief
links [kN/m ]
[kN/m ] [kN/m ]
12,0 )*( 0,4 + 0,0 )=
Restant veranderlijke belasting maatgevend niveau
Veranderlijk (Mom)
rechts
F1 Afstand tot referentie:
2,00 m
Verhoging verandelijke belasting i.v.m.
verd.
Oppervlak
belastingschikking(enkel op maatgevende verdieping) Grep Qrep Perm. Var (M)
[n]
[m²]
[kN/m²] [kN/m²]
0%
[kN]
[kN]
Dak parkeren
1*(
1,0 )*( 65
+
22 )=
65,0 +
15,4
Verd. vloer kantoor
1*(
1,0 )*( 48
+
56 )=
48,0 +
28,0
Hellingbaan
1*(
1,0 )*( 32
+
47 )=
32,0 +
32,9
dakligger str. H
1*(
1,0 )*( 37,0 + 7,0 )=
37,0 +
4,9
vloerligger str. H
1*(
1,0 )*( 55,0 + 19,0 )=
55,0 +
19,0
+
42,1
Restant veranderlijke belasting maatgevend niveau Totaal representatief
237,0 + 142,3
F2 Afstand tot referentie:
5,10 m
Verhoging verandelijke belasting i.v.m.
verd.
Oppervlak
belastingschikking(enkel op maatgevende verdieping) Grep Qrep Perm. Var (M)
[n]
[m²]
[kN/m²] [kN/m²]
[kN]
[kN]
Dak parkeren
1*(
1,0 )*( 253 +
69 )=
253,0 +
48,3
Verd. vloer kantoor
1*(
1,0 )*( 185 + 173 )=
185,0 +
86,5
Hellingbaan
1*(
1,0 )*( 233 +
233,0 +
39,9
57 )=
Restant veranderlijke belasting maatgevend niveau Totaal representatief
0%
+ 107,2 671,0 + 281,9
belastingafdracht fundering
V001 - 80 van 248
Project: Saturn Duiven Projectnr: 130583
F3 Afstand tot referentie:
9,60 m
Verhoging verandelijke belasting i.v.m.
verd.
Oppervlak
belastingschikking(enkel op maatgevende verdieping) Grep Qrep Perm. Var (M)
[n]
[m²]
[kN/m²] [kN/m²]
[kN]
[kN]
Dak parkeren
1*(
1,0 )*( 283 +
78 )=
283,0 +
54,6
Verd. vloer kantoor
1*(
1,0 )*( 205 + 192 )=
205,0 +
96,0
Hellingbaan
1*(
1,0 )*( 266 +
266,0 +
44,1
63 )=
Restant veranderlijke belasting maatgevend niveau
0%
+ 119,4
Totaal representatief
754,0 + 314,1
F4 Afstand tot referentie:
14,10 m
Verhoging verandelijke belasting i.v.m.
verd.
Oppervlak
belastingschikking(enkel op maatgevende verdieping) Grep Qrep Perm. Var (M)
[n]
[m²]
[kN/m²] [kN/m²]
[kN]
[kN]
Dak parkeren
1*(
1,0 )*( 245 +
76 )=
245,0 +
53,2
Verd. vloer kantoor
1*(
1,0 )*( 187 + 187 )=
187,0 +
93,5
Hellingbaan
1*(
1,0 )*( 107 +
107,0 +
41,3
59 )=
Restant veranderlijke belasting maatgevend niveau
0%
+ 116,3
Totaal representatief
539,0 + 304,3
F5 Afstand tot referentie:
18,00 m
Verhoging verandelijke belasting i.v.m.
verd.
Oppervlak
belastingschikking(enkel op maatgevende verdieping) Grep Qrep Perm. Var (M)
[n]
[m²]
[kN/m²] [kN/m²]
[kN]
[kN]
Dak parkeren
1*(
1,0 )*( 260 +
81 )=
260,0 +
56,7
Verd. vloer kantoor
1*(
1,0 )*( 141 + 146 )=
141,0 +
73,0
Hellingbaan
1*(
1,0 )*( 162 +
162,0 +
44,1
+
97,3
63 )=
Restant veranderlijke belasting maatgevend niveau Totaal representatief
0%
563,0 + 271,1
F6 - poer Afstand tot referentie:
23,15 m
Verhoging verandelijke belasting i.v.m.
verd.
Oppervlak
belastingschikking(enkel op maatgevende verdieping) Grep Qrep Perm. Var (M)
[n]
[m²]
[kN/m²] [kN/m²]
[kN]
[kN]
Dak parkeren
1*(
1,0 )*( 361 +
93 )=
361,0 +
65,1
Verd. vloer kantoor
1*(
1,0 )*( 145 + 125 )=
145,0 +
62,5
Hellingbaan
1*(
1,0 )*( 257 +
257,0 +
58,8
+
90,4
84 )=
Restant veranderlijke belasting maatgevend niveau Totaal representatief
0%
763,0 + 276,8
belastingafdracht fundering
V001 - 81 van 248
Project: Saturn Duiven Projectnr: 130583
F7 - poer Afstand tot referentie:
28,30 m
Verhoging verandelijke belasting i.v.m.
verd.
Oppervlak
belastingschikking(enkel op maatgevende verdieping) Grep Qrep Perm. Var (M)
[n]
[m²]
[kN/m²] [kN/m²]
[kN]
[kN]
Dak parkeren
1*(
1,0 )*( 320 +
90 )=
320,0 +
63,0
Verd. vloer kantoor
1*(
1,0 )*( 128 + 117 )=
128,0 +
58,5
Hellingbaan
1*(
1,0 )*( 335 +
335,0 +
67,2
+
87,3
96 )=
Restant veranderlijke belasting maatgevend niveau Totaal representatief
0%
783,0 + 276,0
F8 - poer Afstand tot referentie:
36,80 m
Verhoging verandelijke belasting i.v.m.
verd.
Oppervlak
belastingschikking(enkel op maatgevende verdieping) Grep Qrep Perm. Var (M)
[n]
[m²]
[kN/m²] [kN/m²]
[kN]
[kN]
Dak parkeren
1*(
1,0 )*( 604 + 162 )=
604,0 +
113,4
Verd. vloer kantoor
1*(
1,0 )*( 222 + 184 )=
222,0 +
92,0
Hellingbaan
1*(
1,0 )*( 332 +
332,0 +
27,3
39 )=
Restant veranderlijke belasting maatgevend niveau
0%
+ 140,6
Totaal representatief
1158,0 + 373,3
F9 - poer verd. [n]
Oppervlak ²
[m ]
Grep
Qrep
Perm.
Var (M)
[kN/m ] [kN/m²]
[kN]
[kN]
²
Dak parkeren
1*(
1,0 )*( 514 + 143 )=
514,0 +
100,1
Verd. vloer kantoor
1*(
1,0 )*( 71
69 )=
71,0 +
34,5
Hellingbaan
1*(
1,0 )*( 129 + 115 )=
129,0 +
80,5
+
77,4
+
Restant veranderlijke belasting maatgevend niveau Totaal representatief
714,0 + 292,5
F10 - poer verd. [n] Dak parkeren
Oppervlak ²
[m ]
1*(
Grep
Qrep
Perm.
Var (M)
[kN/m ] [kN/m ]
[kN]
[kN]
1,0 )*( 218 + 119 )=
218,0 +
83,3
+
35,7
²
²
Restant veranderlijke belasting maatgevend niveau Totaal representatief
218,0 + 119,0
F11 - poer verd. [n] Dak parkeren
Oppervlak ²
[m ]
1*(
Grep
Qrep
²
²
[kN/m ] [kN/m ] 1,0 )*( 47
+
53 )=
Restant veranderlijke belasting maatgevend niveau Totaal representatief
belastingafdracht fundering
Perm.
Var (M)
[kN]
[kN]
47,0 +
37,1
+
15,9
47,0 +
53,0
V001 - 82 van 248
Project: Saturn Duiven Projectnr: 130583
10.3
STRAMIEN 7
Belastingen q1 Lengte last:
10,25 m
Verhoging verandelijke belasting i.v.m.
Afstand tot referentie:
0,00 m
belastingschikking (enkel op maatgevende verdieping)
aantal verd. [n] Bostwering d=150 mm
Hoogte/Breedte links
1*(
Bgg vloer winkel
1*(
Qrep
²
links ²
[kN/m ] [kN/m ]
[m]
1*(
Pui
Permanent Grep
rechts
[m]
0% Veranderlijk (Mom)
rechts
¹
¹
5,6
links
rechts
[kN/m ]
[kN/m¹]
5,6
0,0
0,0
[kN/m ] [kN/m ]
¹
1,5 ) (
1,5 )*( 3,8 + 0,0 )=
15,5 ) (
15,5 )*( 0,4 + 0,0 )=
6,2
6,2
0,0
0,0
4,2 )*( 5,0 + 5,0 )=
10,4
10,4
4,2
4,2
6,2
6,2
22,2
22,2
10,4
10,4
0,5 *
4,2 ) ( 0,5 *
Restant veranderlijke belasting maatgevend niveau
+
Totaal representatief q2 Lengte last:
42,75 m
Verhoging verandelijke belasting i.v.m.
Afstand tot referentie:
10,25 m
belastingschikking (enkel op maatgevende verdieping)
aantal verd. [n] Bostwering d=150 mm
Hoogte/Breedte links
1*(
Pui
1*(
Verd. vloer winkel
1*(
0,5 *
Permanent Grep
rechts
[m]
0%
[m]
Qrep
²
links ²
[kN/m ] [kN/m ]
Veranderlijk (Mom)
rechts
¹
¹
5,6
links
rechts
[kN/m ]
[kN/m¹]
5,6
0,0
0,0
[kN/m ] [kN/m ]
¹
1,5 ) (
1,5 )*( 3,8 + 0,0 )=
12,0 ) (
12,0 )*( 0,4 + 0,0 )=
4,8
4,8
0,0
0,0
4,2 )*( 6,0 + 5,0 )=
12,4
12,4
4,2
4,2
6,2
6,2
10,4
10,4
4,2 ) ( 0,5 *
Restant veranderlijke belasting maatgevend niveau
+
Totaal representatief
22,8
22,8
F1 Afstand tot referentie:
0,920 m
Verhoging verandelijke belasting i.v.m.
verd.
Oppervlak
belastingschikking(enkel op maatgevende verdieping) Grep Qrep Perm. Var (M)
[n]
[m²]
[kN/m²] [kN/m²]
[kN]
0%
[kN]
Dak parkeren
1*(
1,0 )*( 117 +
31 )=
117,0 +
21,7
Verd. vloer winkel
1*(
1,0 )*( 100 +
78 )=
100,0 +
31,2
dakligger str. H
1*(
1,0 )*(
1
)=
3,0 +
0,7
vloerligger str. H
1*(
1,0 )*( 5,0 + 3,0 )=
5,0 +
1,2
+
56,1
3
+
Restant veranderlijke belasting maatgevend niveau Totaal representatief
225,0 + 110,9
belastingafdracht fundering
V001 - 83 van 248
Project: Saturn Duiven Projectnr: 130583
F2 Afstand tot referentie:
5,585 m
Verhoging verandelijke belasting i.v.m.
verd.
Oppervlak
belastingschikking(enkel op maatgevende verdieping) Grep Qrep Perm. Var (M)
[n]
[m²]
[kN/m²] [kN/m²]
[kN]
[kN]
Dak parkeren
1*(
1,0 )*( 211 +
56 )=
211,0 +
39,2
Verd. vloer winkel
1*(
1,0 )*( 181 + 141 )=
181,0 +
56,4
Restant veranderlijke belasting maatgevend niveau
0%
+ 101,4
Totaal representatief
392,0 + 197,0
F3 Afstand tot referentie:
10,250 m
Verhoging verandelijke belasting i.v.m.
verd.
Oppervlak
belastingschikking(enkel op maatgevende verdieping) Grep Qrep Perm. Var (M)
[n]
[m²]
[kN/m²] [kN/m²]
[kN]
[kN]
Dak parkeren
1*(
1,0 )*( 177 +
52 )=
177,0 +
36,4
Verd. vloer winkel
1*(
1,0 )*( 152 + 130 )=
152,0 +
52,0
+
93,6
Restant veranderlijke belasting maatgevend niveau Totaal representatief
0%
329,0 + 182,0
F4 Afstand tot referentie:
14,500 m
Verhoging verandelijke belasting i.v.m.
verd.
Oppervlak
belastingschikking(enkel op maatgevende verdieping) Grep Qrep Perm. Var (M)
[n]
[m²]
[kN/m²] [kN/m²]
[kN]
[kN]
Dak parkeren
1*(
1,0 )*( 169 +
50 )=
169,0 +
35,0
Verd. vloer winkel
1*(
1,0 )*( 145 + 126 )=
145,0 +
50,4
+
90,6
Restant veranderlijke belasting maatgevend niveau Totaal representatief
0%
314,0 + 176,0 WINDBELASTING ± 219,3
F5 Afstand tot referentie:
18,500 m
Verhoging verandelijke belasting i.v.m.
verd.
Oppervlak
belastingschikking(enkel op maatgevende verdieping) Grep Qrep Perm. Var (M)
[n]
[m²]
[kN/m²] [kN/m²]
[kN]
[kN]
Dak parkeren
1*(
1,0 )*( 154 +
49 )=
154,0 +
34,3
Verd. vloer winkel
1*(
1,0 )*( 132 + 122 )=
132,0 +
48,8
+
87,9
Restant veranderlijke belasting maatgevend niveau Totaal representatief
0%
286,0 + 171,0
belastingafdracht fundering
V001 - 84 van 248
Project: Saturn Duiven Projectnr: 130583
F6 Afstand tot referentie:
22,500 m
Verhoging verandelijke belasting i.v.m.
verd.
Oppervlak
belastingschikking(enkel op maatgevende verdieping) Grep Qrep Perm. Var (M)
[n]
[m²]
[kN/m²] [kN/m²]
[kN]
[kN] 38,5
Dak parkeren
1*(
1,0 )*( 187 +
55 )=
187,0 +
Verd. vloer winkel
1*(
1,0 )*( 161 + 137 )=
161,0 +
54,8
+
98,7
Restant veranderlijke belasting maatgevend niveau Totaal representatief
0%
348,0 + 192,0 WINDBELASTING ± 219,3
F7 Afstand tot referentie:
27,583 m
Verhoging verandelijke belasting i.v.m.
verd.
Oppervlak
belastingschikking(enkel op maatgevende verdieping) Grep Qrep Perm. Var (M)
[n]
[m²]
[kN/m²] [kN/m²]
[kN]
[kN]
Dak parkeren
1*(
1,0 )*( 212 +
59 )=
212,0 +
41,3
Verd. vloer winkel
1*(
1,0 )*( 182 + 148 )=
182,0 +
59,2
Restant veranderlijke belasting maatgevend niveau
0%
+ 106,5
Totaal representatief
394,0 + 207,0
F8 Afstand tot referentie:
32,666 m
Verhoging verandelijke belasting i.v.m.
verd.
Oppervlak
belastingschikking(enkel op maatgevende verdieping) Grep Qrep Perm. Var (M)
[n]
[m²]
[kN/m²] [kN/m²]
[kN]
[kN]
Dak parkeren
1*(
1,0 )*( 205 +
59 )=
205,0 +
41,3
Verd. vloer winkel
1*(
1,0 )*( 176 + 149 )=
176,0 +
59,6
Restant veranderlijke belasting maatgevend niveau
0%
+ 107,1
Totaal representatief
381,0 + 208,0
F9 Afstand tot referentie:
37,750 m
Verhoging verandelijke belasting i.v.m.
verd.
Oppervlak
belastingschikking(enkel op maatgevende verdieping) Grep Qrep Perm. Var (M)
[n]
[m²]
[kN/m²] [kN/m²]
[kN]
[kN]
Dak parkeren
1*(
1,0 )*( 209 +
60 )=
209,0 +
42,0
Verd. vloer winkel
1*(
1,0 )*( 180 + 151 )=
180,0 +
60,4
Restant veranderlijke belasting maatgevend niveau Totaal representatief
0%
+ 108,6 389,0 + 211,0
belastingafdracht fundering
V001 - 85 van 248
Project: Saturn Duiven Projectnr: 130583
F10 Afstand tot referentie:
42,834 m
Verhoging verandelijke belasting i.v.m.
verd.
Oppervlak
belastingschikking(enkel op maatgevende verdieping) Grep Qrep Perm. Var (M)
[n]
[m²]
[kN/m²] [kN/m²]
0%
[kN]
[kN]
Dak parkeren
1*(
1,0 )*( 199 +
59 )=
199,0 +
41,3
Verd. vloer winkel
1*(
1,0 )*( 171 + 148 )=
171,0 +
59,2
Restant veranderlijke belasting maatgevend niveau
+ 106,5
Totaal representatief
370,0 + 207,0
F11 Afstand tot referentie:
47,917 m
Verhoging verandelijke belasting i.v.m.
verd.
Oppervlak
belastingschikking(enkel op maatgevende verdieping) Grep Qrep Perm. Var (M)
[n]
[m²]
[kN/m²] [kN/m²]
0%
[kN]
[kN]
Dak parkeren
1*(
1,0 )*( 235 +
62 )=
235,0 +
43,4
Verd. vloer winkel
1*(
1,0 )*( 202 + 155 )=
202,0 +
62,0
Restant veranderlijke belasting maatgevend niveau
+ 111,6
Totaal representatief
437,0 + 217,0
F12 Afstand tot referentie:
53,000 m
Verhoging verandelijke belasting i.v.m.
verd.
Oppervlak
belastingschikking(enkel op maatgevende verdieping) Grep Qrep Perm. Var (M)
[n]
[m²]
[kN/m²] [kN/m²]
[kN]
0%
[kN]
Dak parkeren
1*(
1,0 )*( 82
+
23 )=
82,0 +
16,1
Verd. vloer winkel
1*(
1,0 )*( 70
+
57 )=
70,0 +
22,8
dakligger str. A
1*(
1,0 )*( 11,0 + 2,0 )=
11,0 +
1,4
vloerligger str. A
1*(
1,0 )*( 15,0 + 6,0 )=
15,0 +
2,4
+
41,1
178,0 +
83,8
Restant veranderlijke belasting maatgevend niveau Totaal representatief
belastingafdracht fundering
V001 - 86 van 248
Project: Saturn Duiven Projectnr: 130583
10.4
STRAMIEN A
Belastingen q1 Lengte last:
4,50 m
Verhoging verandelijke belasting i.v.m.
Afstand tot referentie:
0,00 m
belastingschikking (enkel op maatgevende verdieping)
aantal verd. [n] Pui
1*(
Bgg vloer magazijn
1*(
Hoogte/Breedte links
Permanent
rechts
[m] 15,5 ) (
Grep
Qrep
²
links ²
[kN/m ] [kN/m ]
[m]
0,5 *
0%
3,3 ) ( 0,5 *
¹
¹
6,2
6,2
8,1
8,1
[kN/m ] [kN/m ]
15,5 )*( 0,4 + 0,0 )= 3,3 )*( 5,0 + 5,0 )=
Restant veranderlijke belasting maatgevend niveau
Veranderlijk (Mom)
rechts
+
Totaal representatief
14,3
14,3
links ¹
rechts
[kN/m ]
[kN/m¹]
0,0
0,0
8,1
8,1
0,0
0,0
8,1
8,1
q2 Lengte last:
40,50 m
Verhoging verandelijke belasting i.v.m.
Afstand tot referentie:
4,50 m
belastingschikking (enkel op maatgevende verdieping)
aantal verd. [n]
Hoogte/Breedte links
Permanent
rechts
[m]
0%
Grep
Qrep
[kN/m²] [kN/m²]
[m]
links
Veranderlijk (Mom)
rechts
links
rechts
[kN/m¹] [kN/m¹]
[kN/m¹]
[kN/m¹]
Bostwering d=150 mm
1*(
1,5 ) (
1,5 )*( 3,8 + 0,0 )=
5,6
5,6
0,0
0,0
Pui
1*(
12,0 ) (
12,0 )*( 0,4 + 0,0 )=
4,8
4,8
0,0
0,0
Verd. vloer winkel
1*(
13,4
13,4
0,5 *
4,5 ) ( 0,5 *
4,5 )*( 6,0 + 5,0 )=
Restant veranderlijke belasting maatgevend niveau
+
Totaal representatief
23,8
23,8
4,5
4,5
6,7
6,7
11,3
11,3
q3 Lengte last:
10,00 m
Verhoging verandelijke belasting i.v.m.
Afstand tot referentie:
45,00 m
belastingschikking (enkel op maatgevende verdieping)
aantal verd. [n]
Hoogte/Breedte links
Permanent
rechts
[m]
[m]
0%
Grep
Qrep
[kN/m²] [kN/m²]
links
Veranderlijk (Mom)
rechts
links
rechts
[kN/m¹] [kN/m¹]
[kN/m¹]
[kN/m¹]
Bostwering d=150 mm
1*(
1,5 ) (
1,5 )*( 3,8 + 0,0 )=
5,6
5,6
0,0
0,0
Pui
1*(
12,0 ) (
12,0 )*( 0,4 + 0,0 )=
4,8
4,8
0,0
0,0
Verd. vloer winkel
1*(
9,7
9,7
0,5 *
3,3 ) ( 0,5 *
3,3 )*( 6,0 + 5,0 )=
Restant veranderlijke belasting maatgevend niveau Totaal representatief
+ 20,1
belastingafdracht fundering
20,1
3,3
3,3
4,9
4,9
8,1
8,1
V001 - 87 van 248
Project: Saturn Duiven Projectnr: 130583
F1 Afstand tot referentie:
4,500 m
Verhoging verandelijke belasting i.v.m.
verd.
Oppervlak
belastingschikking(enkel op maatgevende verdieping) Grep Qrep Perm. Var (M)
[n]
[m²]
[kN/m²] [kN/m²]
0%
[kN]
[kN] 18,9
Dak parkeren
1*(
1,0 )*( 97
+
27 )=
97,0 +
Hellingbaan
1*(
1,0 )*( 88
+
)=
88,0 +
0,0
+
8,1
185,0 +
27,0
Restant veranderlijke belasting maatgevend niveau Totaal representatief F2 Afstand tot referentie:
9,750 m
Verhoging verandelijke belasting i.v.m.
verd.
Oppervlak
belastingschikking(enkel op maatgevende verdieping) Grep Qrep Perm. Var (M)
[n]
[m²]
[kN/m²] [kN/m²]
[kN]
[kN]
Dak parkeren
1*(
1,0 )*( 193 +
51 )=
193,0 +
35,7
Hellingbaan
1*(
1,0 )*( 155 + 141 )=
155,0 +
98,7
+
57,6
Restant veranderlijke belasting maatgevend niveau Totaal representatief
0%
348,0 + 192,0
F3 Afstand tot referentie:
15,000 m
Verhoging verandelijke belasting i.v.m.
verd.
Oppervlak
belastingschikking(enkel op maatgevende verdieping) Grep Qrep Perm. Var (M)
[n]
[m²]
[kN/m²] [kN/m²]
[kN]
[kN]
Dak parkeren
1*(
1,0 )*( 163 +
58 )=
163,0 +
40,6
Hellingbaan
1*(
1,0 )*( 156 + 130 )=
156,0 +
91,0
+
56,4
Restant veranderlijke belasting maatgevend niveau Totaal representatief
0%
319,0 + 188,0 WINDBELASTING ± 223,4
F4 Afstand tot referentie:
20,000 m
Verhoging verandelijke belasting i.v.m.
verd.
Oppervlak
belastingschikking(enkel op maatgevende verdieping) Grep Qrep Perm. Var (M)
[n]
[m²]
[kN/m²] [kN/m²] +
[kN]
[kN]
Dak parkeren
1*(
1,0 )*( 34
79 )=
33,5 +
55,3
Hellingbaan
1*(
1,0 )*( 156 + 126 )=
156,0 +
88,2
+
61,5
Restant veranderlijke belasting maatgevend niveau Totaal representatief
0%
189,5 + 205,0
belastingafdracht fundering
V001 - 88 van 248
Project: Saturn Duiven Projectnr: 130583
F5 Afstand tot referentie:
25,000 m
Verhoging verandelijke belasting i.v.m.
verd.
Oppervlak
belastingschikking(enkel op maatgevende verdieping) Grep Qrep Perm. Var (M)
[n]
[m²]
[kN/m²] [kN/m²] +
0%
[kN]
[kN] 19,6
Dak parkeren
1*(
1,0 )*( 48
28 )=
47,8 +
Hellingbaan
1*(
1,0 )*( 154 + 122 )=
154,0 +
85,4
+
45,0
Restant veranderlijke belasting maatgevend niveau Totaal representatief
201,8 + 150,0 WINDBELASTING ± 223,4
F6 Afstand tot referentie:
30,000 m
Verhoging verandelijke belasting i.v.m.
verd.
Oppervlak
belastingschikking(enkel op maatgevende verdieping) Grep Qrep Perm. Var (M)
[n]
[m²]
[kN/m²] [kN/m²]
[kN]
0%
[kN]
Dak parkeren
1*(
1,0 )*( 32
+
6
)=
32,0 +
4,2
Verd. vloer winkel
1*(
1,0 )*( 17
+
6
)=
17,0 +
2,4
)*( 45,0 + 2,0 )=
0,0 +
0,0
Hellingbaan
*(
Restant veranderlijke belasting maatgevend niveau Totaal representatief
+
5,4
49,0 +
12,0
F7 Afstand tot referentie:
35,000 m
Verhoging verandelijke belasting i.v.m.
verd.
Oppervlak
[n]
[m²]
0%
belastingschikking(enkel op maatgevende verdieping) Grep Qrep Perm. Var (M) [kN/m²] [kN/m²]
[kN]
[kN]
Dak parkeren
1*(
1,0 )*( 27
+
6
)=
27,0 +
Verd. vloer winkel
1*(
1,0 )*( 47
+
16 )=
47,0 +
6,4
+
11,4
74,0 +
22,0
Restant veranderlijke belasting maatgevend niveau Totaal representatief
4,2
F8 Afstand tot referentie:
40,000 m
Verhoging verandelijke belasting i.v.m.
verd.
Oppervlak
[n]
[m²]
0%
belastingschikking(enkel op maatgevende verdieping) Grep Qrep Perm. Var (M) [kN/m²] [kN/m²]
[kN]
[kN]
Dak parkeren
1*(
1,0 )*( 29
+
6
)=
29,0 +
Verd. vloer winkel
1*(
1,0 )*( 37
+
15 )=
37,0 +
6,0
+
10,8
66,0 +
21,0
Restant veranderlijke belasting maatgevend niveau Totaal representatief
belastingafdracht fundering
4,2
V001 - 89 van 248
Project: Saturn Duiven Projectnr: 130583
F9 Afstand tot referentie:
45,000 m
Verhoging verandelijke belasting i.v.m.
verd.
Oppervlak
belastingschikking(enkel op maatgevende verdieping) Grep Qrep Perm. Var (M)
[n]
[m²]
[kN/m²] [kN/m²]
[kN]
0%
[kN]
Dak parkeren
1*(
1,0 )*( 27
+
6
)=
27,0 +
Verd. vloer winkel
1*(
1,0 )*( 38
+
15 )=
38,0 +
6,0
+
10,8
65,0 +
21,0
Restant veranderlijke belasting maatgevend niveau Totaal representatief
4,2
F10 Afstand tot referentie:
50,000 m
Verhoging verandelijke belasting i.v.m.
verd.
Oppervlak
belastingschikking(enkel op maatgevende verdieping) Grep Qrep Perm. Var (M)
[n]
[m²]
[kN/m²] [kN/m²]
[kN]
0%
[kN]
Dak parkeren
1*(
1,0 )*( 32
+
6
)=
32,0 +
4,2
Verd. vloer winkel
1*(
1,0 )*( 44
+
15 )=
44,0 +
6,0
+
10,8
76,0 +
21,0
Restant veranderlijke belasting maatgevend niveau Totaal representatief
belastingafdracht fundering
V001 - 90 van 248
Project: Saturn Duiven Projectnr: 130583
10.5
STRAMIEN H
Belastingen q1 Lengte last:
18,00 m
Verhoging verandelijke belasting i.v.m.
Afstand tot referentie:
0,00 m
belastingschikking (enkel op maatgevende verdieping)
aantal verd. [n] Pui
Hoogte/Breedte links
1*(
Bostwering d=150 mm
1*(
Bgg vloer magazijn
1*(
Permanent
rechts
[m]
0%
Grep
Qrep
²
links ²
[kN/m ] [kN/m ]
[m]
Veranderlijk (Mom)
rechts
¹
¹
[kN/m ] [kN/m ]
links ¹
rechts
[kN/m ]
[kN/m¹]
12,0 ) (
12,0 )*( 0,4 + 0,0 )=
4,8
4,8
0,0
0,0
1,5 ) (
1,5 )*( 3,8 + 0,0 )=
5,6
5,6
0,0
0,0
3,3 ) ( 0,5 *
3,3 )*( 5,0 + 5,0 )=
8,1
8,1
8,1
8,1
0,0
0,0
18,6
18,6
8,1
8,1
0,5 *
Restant veranderlijke belasting maatgevend niveau
+
Totaal representatief q2 Lengte last:
31,00 m
Verhoging verandelijke belasting i.v.m.
Afstand tot referentie:
18,00 m
belastingschikking (enkel op maatgevende verdieping)
aantal verd. [n] Bostwering d=150 mm
Hoogte/Breedte links
1*(
Pui
1*(
Verd. vloer winkel
1*(
0,5 *
Permanent
rechts
[m]
0%
[m]
Grep
Qrep
²
links ²
[kN/m ] [kN/m ]
Veranderlijk (Mom)
rechts
¹
¹
5,6
links
rechts
[kN/m ]
[kN/m¹]
5,6
0,0
0,0
[kN/m ] [kN/m ]
¹
1,5 ) (
1,5 )*( 3,8 + 0,0 )=
12,0 ) (
12,0 )*( 0,4 + 0,0 )=
4,8
4,8
0,0
0,0
4,5 )*( 6,0 + 5,0 )=
13,4
13,4
4,5
4,5
6,7
6,7
11,3
11,3
4,5 ) ( 0,5 *
Restant veranderlijke belasting maatgevend niveau
+
Totaal representatief
23,8
23,8
F1 Afstand tot referentie:
4,000 m
Verhoging verandelijke belasting i.v.m.
verd.
Oppervlak
belastingschikking(enkel op maatgevende verdieping) Grep Qrep Perm. Var (M)
[n]
[m²]
[kN/m²] [kN/m²]
[kN]
0%
[kN]
Dakligger str. H
1*(
1,0 )*( 18
+
5
)=
18 +
3
Vloerligger str. H
1*(
1,0 )*( 20
+
12 )=
20 +
5
Restant veranderlijke belasting maatgevend niveau Totaal representatief
belastingafdracht fundering
+
9
39 +
17
V001 - 91 van 248
Project: Saturn Duiven Projectnr: 130583
F2 Afstand tot referentie:
8,000 m
Verhoging verandelijke belasting i.v.m.
verd.
Oppervlak
belastingschikking(enkel op maatgevende verdieping) Grep Qrep Perm. Var (M)
[n]
[m²]
[kN/m²] [kN/m²]
[kN] )=
0%
[kN]
Dakligger str. H
1*(
1,0 )*( 27
+
6
27 +
Vloerligger str. H
1*(
1,0 )*( 37
+
14 )=
37 +
6
Dakligger str. 3
1*(
1,0 )*( 175 +
54 )=
175 +
38
Vloerligger str. 3
1*(
1,0 )*( 133 + 135 )=
133 +
54
+
97
371 +
198
WINDBELASTING ±
223
Restant veranderlijke belasting maatgevend niveau Totaal representatief
4
F3 Afstand tot referentie:
13,000 m
Verhoging verandelijke belasting i.v.m.
verd.
Oppervlak
[n]
[m²]
0%
belastingschikking(enkel op maatgevende verdieping) Grep Qrep Perm. Var (M) [kN/m²] [kN/m²]
[kN]
[kN]
Dakligger str. H
1*(
1,0 )*( 28
+
6
)=
28 +
Vloerligger str. H
1*(
1,0 )*( 45
+
15 )=
45 +
6
+
11
73 +
21
Restant veranderlijke belasting maatgevend niveau Totaal representatief
4
F4 Afstand tot referentie:
18,000 m
Verhoging verandelijke belasting i.v.m.
verd.
Oppervlak
belastingschikking(enkel op maatgevende verdieping) Grep Qrep Perm. Var (M)
[n]
[m²]
[kN/m²] [kN/m²]
[kN]
0%
[kN]
Dakligger str. H
1*(
1,0 )*( 31
+
6
)=
31 +
4
Vloerligger str. H
1*(
1,0 )*( 33
+
12 )=
33 +
5
Dakligger str. 4
1*(
1,0 )*( 194 +
60 )=
194 +
42
Vloerligger str. 4
1*(
1,0 )*( 152 + 151 )=
152 +
60
+
109
409 +
220
WINDBELASTING ±
223
Restant veranderlijke belasting maatgevend niveau Totaal representatief F5 Afstand tot referentie:
24,550 m
Verhoging verandelijke belasting i.v.m.
verd.
Oppervlak
[n]
[m²]
0%
belastingschikking(enkel op maatgevende verdieping) Grep Qrep Perm. Var (M) [kN/m²] [kN/m²]
[kN]
[kN]
Dakligger str. H
1*(
1,0 )*( 29
+
6
)=
29 +
Vloerligger str. H
1*(
1,0 )*( 49
+
16 )=
49 +
6
+
11
78 +
22
Restant veranderlijke belasting maatgevend niveau Totaal representatief
belastingafdracht fundering
4
V001 - 92 van 248
Project: Saturn Duiven Projectnr: 130583
F6 Afstand tot referentie:
29,000 m
Verhoging verandelijke belasting i.v.m.
verd.
Oppervlak
belastingschikking(enkel op maatgevende verdieping) Grep Qrep Perm. Var (M)
[n]
[m²]
[kN/m²] [kN/m²]
Dakligger str. H
1*(
1,0 )*( 26
+
Dakligger str. H
1*(
0,5 )*( 29
Vloerligger str. H
1*(
1,0 )*( 39
Vloerligger str. H
1*(
0,5 )*( 40
Dakligger str. 5
1*(
Vloerligger str. 5
1*(
[kN]
0%
[kN]
6
)=
26 +
4
+
6
)=
15 +
2
+
15 )=
39 +
6
+
15 )=
20 +
3
1,0 )*( 194 +
60 )=
194 +
42
1,0 )*( 152 + 151 )=
152 +
60
Restant veranderlijke belasting maatgevend niveau Totaal representatief
+
99
445 +
216
F7 Afstand tot referentie:
39,000 m
Verhoging verandelijke belasting i.v.m.
verd.
Oppervlak
[n]
[m²]
0%
belastingschikking(enkel op maatgevende verdieping) Grep Qrep Perm. Var (M) [kN/m²] [kN/m²]
[kN]
[kN]
Dakligger str. H
1*(
0,5 )*( 29
+
6
)=
15 +
2
Dakligger str. H
1*(
1,0 )*( 26
+
5
)=
26 +
4
Vloerligger str. H
1*(
0,5 )*( 40
+
15 )=
20 +
3
Vloerligger str. H
1*(
1,0 )*( 36,3 + 13,2 )=
36 +
5
Dakligger str. 6
1*(
1,0 )*( 194 +
60 )=
194 +
42
Vloerligger str. 6
1*(
1,0 )*( 152 + 151 )=
152 +
60
+
99
443 +
215
Restant veranderlijke belasting maatgevend niveau Totaal representatief F8 Afstand tot referentie:
42,400 m
Verhoging verandelijke belasting i.v.m.
verd.
Oppervlak
belastingschikking(enkel op maatgevende verdieping) Grep Qrep Perm. Var (M)
[n]
[m²]
[kN/m²] [kN/m²]
[kN]
0%
[kN]
Dakligger str. H
1*(
1,0 )*(
7
+
2
)=
7+
1
Vloerligger str. H
1*(
1,0 )*(
9
+
4
)=
9+
2
+
3
16 +
6
Restant veranderlijke belasting maatgevend niveau Totaal representatief
belastingafdracht fundering
V001 - 93 van 248
Project: Saturn Duiven Projectnr: 130583
10.6
LIFT (STR 2-3/C-D)
Belastingen F1 Afstand tot referentie:
42,400 m
Verhoging verandelijke belasting i.v.m.
verd.
Oppervlak
belastingschikking(enkel op maatgevende verdieping) Grep Qrep Perm. Var (M)
[n]
[m²]
Kalkzandsteen d=214
1*(
Dak parkeren
1*(
Verd. vloer winkel
1*(
Trafovloer
1*(
[kN/m²] [kN/m²]
25,3 * 12,0 )*(
6,8 *
7
+
2
[kN] 2034 +
0
3,9 )*( 7,7 + 2,0 )=
30 +
5
3,9 )*( 6,0 + 5,0 )=
23 +
8
3,9 )*( 6,3 + 5,0 )=
166 +
53
Totaal representatief Fd Fundamentele combinatie 4.1
[kN]
)=
Restant veranderlijke belasting maatgevend niveau
Rekenwaarden
0%
+
91
2253 +
158
zd
[kN]
[m]
3141,1
0,0
4 palen Ø600
( 785 kN )
LIFT (STR 6-7/E-F)
Belastingen F1 Afstand tot referentie:
42,400 m
Verhoging verandelijke belasting i.v.m.
verd.
Oppervlak
belastingschikking(enkel op maatgevende verdieping) Grep Qrep Perm. Var (M)
[n]
[m²]
[kN/m²] [kN/m²]
[kN]
0%
[kN]
Dak parkeren
1*(
0,5 *
4,3 *
8,0 )*( 7,7 + 2,0 )=
132 +
24
Verd. vloer winkel
1*(
0,5 *
4,3 *
8,0 )*( 6,0 + 5,0 )=
102 +
34
Bgg vloer winkel
1*(
0,5 *
4,3 *
8,0 )*( 5,0 + 5,0 )=
86 +
34
Trafovloer
1*(
0,5 *
5,7 *
8,0 )*( 6,3 + 5,0 )=
143 +
46
Staal trap
1*(
2,0 * 36,0 )*( 1,0 + 4,0 )=
72 +
115
Glazen lift
1*(
12,5 * 16,5 )*( 1,0 + 0,0 )=
206 +
0
+
241
742 +
495
Restant veranderlijke belasting maatgevend niveau Totaal representatief Fd Rekenwaarden Fundamentele combinatie
zd
[kN]
[m]
1632,2
0,0
belastingafdracht fundering
6 palen Ø400
( 272 kN )
V001 - 94 van 248
Project: Saturn Duiven Projectnr: 130583
10.7
LIFT (STR 6-7/G-H)
Belastingen F1 Afstand tot referentie:
42,400 m
Verhoging verandelijke belasting i.v.m.
verd.
Oppervlak
belastingschikking(enkel op maatgevende verdieping) Grep Qrep Perm. Var (M)
[n]
[m²]
[kN/m²] [kN/m²]
[kN]
0%
[kN]
Dak parkeren
1*(
0,5 * 5,80 *
0,3 *
5,8 )*( 7,7 + 2,0 )=
43 +
8
Verd. vloer winkel
1*(
0,5 * 5,80 *
0,3 *
5,8 )*( 6,0 + 5,0 )=
33 +
11
Bgg vloer winkel
1*(
0,5 * 5,80 *
0,3 *
5,8 )*( 5,0 + 5,0 )=
28 +
11
Trafovloer
1*(
4,2 *
5,8 )*( 6,3 + 5,0 )=
152 +
49
Kalkzandsteen d=214
1*(
13,2 * 16,5 )*( 4,3 + 0,0 )=
932 +
0
+
90
1189 +
169
Restant veranderlijke belasting maatgevend niveau Totaal representatief Fd Rekenwaarden Fundamentele combinatie
[kN]
[m]
1723,6
0,0
10.8
POEREN (MAATGEVEND 4-6/B EN 4-6/G)
Belasting F1
verd.
Oppervlak
Grep
Qrep
²
²
²
[kN/m ] [kN/m ]
[m ]
[n]
zd 4 palen Ø400
( 431 kN )
Perm.
Var (M)
[kN]
[kN]
dakligger str. 4-6
1*(
1,0 )*( 648 + 184 )=
648 +
129
vloerligger str. 4-6
1*(
1,0 )*( 499 + 462 )=
499 +
185
Bgg vloer winkel
1*(
20,0 )*( 5,0 + 5,0 )=
100 +
40
Fundering
1*(
3,3 )*( 25,0 + 0,0 )=
82 +
0
+
337
1329 +
691
Restant veranderlijke belasting maatgevend niveau Totaal representatief Fd Rekenwaarden Fundamentele combinatie 10.9
PALEN ONDER BGG
Belasting F1
verd. [n]
Bgg vloer winkel
1*(
Oppervlak
[kN]
[m]
2630,9
0,0
Grep
Qrep
²
[kN/m ] [kN/m²]
²
[m ] 1,1 *
zd
3,3 *
4,0 )*( 5,0 + 5,0 )=
Restant veranderlijke belasting maatgevend niveau Totaal representatief Fd Rekenwaarden Fundamentele combinatie
3 palen Ø600
( 877 kN )
Perm.
Var (M)
[kN]
[kN]
73 +
29
+
44
73 +
73
zd
[kN]
[m]
196,0
0,0
belastingafdracht fundering
1 palen Ø400
( 196 kN )
V001 - 95 van 248
Project: Saturn Duiven
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 130583
Projectnr: 110997
1 BIJLAGE V001
DAKLIGGERS (HE-PROFIELEN)
TS/Liggers
Inhoudsopgave 1
DAKLIGGERS (HE-PROFIELEN) ......................................................................................................... 101
2
DAKLIGGERS (THQ)...................................................................................................................... 128
3
VLOERLIGGERS (HE-PROFIELEN) ...................................................................................................... 151
4
VLOERLIGGERS (THQ)................................................................................................................... 175
5
GEVELKOLOMMEN ....................................................................................................................... 195
6
HELLINGBAAN ............................................................................................................................ 203
7
FUNDERINGSBALKEN .................................................................................................................... 224
Project......: Onderdeel....: Constructeur.: Opdrachtgever: Dimensies....: Datum........: Bestand......:
Rel: 5.27c 19 apr 2013 130583 - Saturn Duiven Dakliggers ENN kN/m/rad 05/04/2013 m:\bouw\projecten\130583 saturn duiven\4_berekeningen\ dakliggers.dlw
Betrouwbaarheidsklasse
: 2
Referentieperiode
: 50
Toegepaste normen volgens Eurocode met Nederlandse NB Belastingen Staal
NEN-EN 1990:2002 NEN-EN 1991-1-1:2002 NEN-EN 1993-1-1:2006
C2:2010 C1:2009 C2:2009
NB:2011(nl) NB:2011(nl) NB:2011(nl)
LIGGER:stramien 1 Profiel : HEA220
GEOMETRIE
Ligger:stramien 1
2 4.65 4.65 4.65 5.333 5.333 5.334 5.000 5.000 3.52.85 4.7 53.000 1:HEA220
VELDLENGTEN
V003C - Bijlagen - 100 van 149
Veld 1 2 3 4 5
Vanaf 0.000 2.000 6.650 11.300 15.950
Tot 2.000 6.650 11.300 15.950 21.283
Lengte 2.000 4.650 4.650 4.650 5.333
11 12
45.450 48.300
48.300 53.000
2.850 4.700
Veld 6 7 8 9 10
Vanaf 21.283 26.616 31.950 36.950 41.950
Tot 26.616 31.950 36.950 41.950 45.450
Ligger:stramien 1 Lengte 5.333 5.334 5.000 5.000 3.500
Bijlagen V001 - 101 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
MATERIALEN
BELASTINGCOMBINATIES
Mt Omschrijving E-mechanica[N/mm2] Cement 1 S235 210000
Kruipcoef. S.M. S.M.verh. Pois. 78.5 0.30
PROFIELEN [mm] Prof. 1 2 3 4 5
Omschrijving HEA220 HEA300 HEA260 HEA240 HEA140
Materiaal 1:S235 1:S235 1:S235 1:S235 1:S235
Oppervlak 6.4300e+003 1.1250e+004 8.6800e+003 7.6800e+003 3.1420e+003
Traagheid 5.4100e+007 1.8260e+008 1.0460e+008 7.7630e+007 1.0330e+007
PROFIELEN vervolg [mm] Prof. Vormf. Breedte Hoogte 1 0.00 220 210 2 0.00 300 290 3 0.00 260 250 4 0.00 240 230 5 0.00 140 133
ey 105.0 145.0 125.0 115.0 66.5
BC 1 2 3 4
Type Fund. Fund. Kar. Perm.
Gen. Factor Perm 1.35 Perm 1.20 Perm 1.00 Perm 1.00
BG 2 2 2
Gen. Factor psi0 1.50 Extr 1.50 Extr 1.00
BG Gen. Factor
BG Gen. Factor
GUNSTIGE WERKING PERMANENTE BELASTINGEN
Ligger:stramien 1
BC Velden met gunstige werking 1 1-12 2 1-12
OMHULLENDE VAN DE FUNDAMENTELE COMBINATIES Type
b1
h1
b2
h2
MOMENTEN
Ligger:stramien 1 Fundamentele combinatie
Velden: 1 t/m 6
BELASTINGGEVALLEN B.G. Omschrijving 1 Permanent 2 Veranderlijk
BG 1 1 1 1
Belast/onbelast 2:Permanent EN1991 1:Schaakbord EN1991
VELDBELASTINGEN
0
1
2
0.40 0.50 0.30
89
119
118
104
91
87
e.g. -1.00 0.00
Ligger:stramien 1 B.G:1 Permanent -51
-47.3
-54
-64
-69 q1=28.5
q2=28.5
37.3
q3=37.31.5
MOMENTEN VELDBELASTINGEN Last Ref. 1 2 3
Type 1:q-last 1:q-last 1:q-last
Omschrijving q1 q2 q3
VELDBELASTINGEN
Ligger:stramien 1 B.G:1 Permanent q1/p/m q2 psi Afstand Lengte -28.500 -28.500 0.000 26.300 -28.500 -37.300 26.300 17.700 -37.300 -1.500 44.000 9.000
Ligger:stramien 1 Fundamentele combinatie
Velden: 7 t/m 12
119
123
118
105
Ligger:stramien 1 B.G:2 Veranderlijk
q1=7
q2=7
9.3
39.2
q3=9.3
-13.6 -34.4 -72
VELDBELASTINGEN Last Ref. 1 2 3
Type 1:q-last 1:q-last 1:q-last
43.2
-62
-29.3
-76
Ligger:stramien 1 B.G:2 Veranderlijk Omschrijving q1/p/m q2 psi Afstand Lengte q1 -7.000 -7.000 0.000 26.300 q2 -7.000 -9.300 26.300 17.700 q3 -9.300 0.000 44.000 9.000
Bijlagen V001 - 102 van 248
Bijlagen V001 - 103 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
DWARSKRACHTEN
Ligger:stramien 1 Fundamentele combinatie
OMHULLENDE VAN DE KARAKTERISTIEKE COMBINATIES
Velden: 1 t/m 6
VERPLAATSINGEN 114
110
110
91
127
126
[mm]
0.84
-108
-111
Fmin:122 Fmax:201
126 220
126 218
-123 138 237
-126 150 253
0.78
0.16
0.47
0.16
-4.71
-5.3
-110
Ligger:stramien 1 Karakteristieke combinatie
Velden: 1 t/m 6
-6.0
151 256
-8.6 -10.1 -12.2
DWARSKRACHTEN
Ligger:stramien 1 Fundamentele combinatie
VERPLAATSINGEN
Velden: 7 t/m 12
[mm]
Ligger:stramien 1 Karakteristieke combinatie
Velden: 7 t/m 12 142
138
134
0.85
0.55
0.17
87
0.54
63
-0.35 21.1
-1.84 -4.07
-65 -130
-132
Fmin:151 Fmax:256
-144 168 282
156 266
-61
-7.2
-124 155 267
-10.3 80 152
72 124
-9.9
11.4 21.1
STAALPROFIELEN - ALGEMENE GEGEVENS REACTIES Stp 1 2 3 4 5 6 7 8 9 10 11 12
Fmin 121.59 126.29 125.64 137.66 149.64 150.76 155.98 167.77 154.91 79.83 72.33 11.43
Fmax 200.85 220.37 218.16 237.05 253.13 256.16 265.57 281.89 266.59 152.28 123.99 21.06
Ligger:stramien 1 Fundamentele combinatie Mmin Mmax 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Bijlagen V001 - 104 van 248
Stabiliteit:
Classificatie gehele constructie:
Ligger:stramien 1 Geschoord
MATERIAAL Mat Profielnaam nr. 1 HEA220 2 HEA300 3 HEA260 4 HEA240 5 HEA140 Partiële veiligheidsfactoren: Gamma M;0 : 1.00
Vloeisp. [N/mm2 ] 235 235 235 235 235 Gamma M;1
Productie methode Gewalst Gewalst Gewalst Gewalst Gewalst
Min. drsn. klasse 1 1 1 1 1 :
1.00
Bijlagen V001 - 105 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
KIPSTABILITEIT Staaf 1
Plts. aangr. 1.0*h
2
1.0*h
3
1.0*h
4
1.0*h
5
1.0*h
6
1.0*h
7
1.0*h
8
1.0*h
9
1.0*h
10
1.0*h
11
1.0*h
12
1.0*h
Kipsteunafstanden [m] 0 2.000 0 4.650 0 4.650 0 4.650 0 5.333
Staaf
boven: onder: boven: onder: boven: onder: boven: onder: boven: onder: boven: onder: boven: onder: boven: onder: boven: onder: boven: onder:
5.33 5.33 5.33 5.33 5.00 5.00 5.00 5.00 3.50 3.50
0 5.333 0 5.334 0 5.000 0 5.000 0 3.500
6
Vloer
7
Vloer
8
Vloer
9
Vloer
10
Vloer
boven: onder: boven: onder:
2.85 2.85 4.70 4.70
0 2.850 0 4.700
11
12
TOETSING SPANNINGEN Staaf Mat BC nr. 1 1 2 1 3 1
TOETSING DOORBUIGING
Ligger:stramien 1 l gaffel [m] 4.00 4.00 4.65 4.65 4.65 4.65 4.65 4.65 5.33 5.33
Sit Kl Plaats Norm Artikel 2 2 1 Einde 2 28 1 Staaf 2 10 1 Begin
EN3-1-1 6.2.8 EN3-1-1 6.3.2 EN3-1-1 6.2.8
1 2 3 4 5
Soort Mtg Lengte Overst Zeeg ut o t BC Sit [m] I J [mm] [mm] Vloer ss 2.00 J N 0.0 -12.2 3 2 Eind ss 3 2 Bijk Vloer db 4.65 N N 0.0 -5.3 3 3 Eind db 3 2 Bijk Vloer db 4.65 N N 0.0 -6.0 3 2 Eind db 3 2 Bijk Vloer db 4.65 N N 0.0 -4.7 3 3 Eind db 3 2 Bijk Vloer db 5.33 N N 0.0 -10.1 3 2 Eind db 3 2 Bijk db db db db db db db db db db
5.33
N
N
0.0
-8.6
5.33
N
N
0.0 -10.3
5.00
N
N
0.0
-7.2
5.00
N
N
0.0
-9.9
3.50
N
N
0.0
-1.8
Vloer
db
2.85
N
N
0.0
0.5 -0.4
Vloer
db db db
4.70
N
N
0.0
-4.1
Ligger:stramien 1 u Toelaatbaar [mm] [mm] *l -12.2 ±16.0 2*0.004 -5.7 ±12.0 2*0.003 -5.3 ±18.6 0.004 3.4 ±14.0 0.003 -6.0 ±18.6 0.004 -2.5 ±14.0 0.003 -4.7 ±18.6 0.004 3.1 ±14.0 0.003 -10.1 ±21.3 0.004 -3.7 ±16.0 0.003
3 3 3 3 3 3 3 3 3 3
3 3 2 2 3 3 2 2 3 2
Eind Bijk Eind Bijk Eind Bijk Eind Bijk Eind Bijk
-8.6 -3.8 -10.3 -4.0 -7.2 -3.3 -9.9 -3.2 -1.8 1.7
±21.3 ±16.0 ±21.3 ±16.0 ±20.0 ±15.0 ±20.0 ±15.0 ±14.0 ±10.5
0.004 0.003 0.004 0.003 0.004 0.003 0.004 0.003 0.004 0.003
3 3 3 3 3
3 2 2 3 3
Eind Eind Bijk Eind Bijk
0.5 -0.4 -0.6 -4.1 -1.0
±11.4
0.004
±8.6 ±18.8 ±14.1
0.003 0.004 0.003
Ligger:stramien 1 Hoogste toetsing Opm. U.C. [N/mm 2 ] (6.30) 0.678 159 (6.54) 0.749 176 (6.30) 0.667 157
Formule
TOETSING SPANNINGEN
Ligger:stramien 1 Staaf Mat BC Sit Kl Plaats Norm Artikel Formule Hoogste toetsing Opm. nr. U.C. [N/mm 2 ] 4 1 2 14 1 Einde EN3-1-1 6.2.8 (6.30) 0.777 183 5 1 2 16 1 Einde EN3-1-1 6.2.8 (6.30) 0.880 207 6 7 8 9 10
1 1 1 1 1
2 2 2 2 2
18 18 22 22 24
1 1 1 1 1
Einde Begin Einde Begin Begin
EN3-1-1 EN3-1-1 EN3-1-1 EN3-1-1 EN3-1-1
6.2.8 6.2.8 6.2.8 6.2.8 6.2.8
(6.30) (6.30) (6.30) (6.30) (6.30)
11 1 2 28 1 Einde EN3-1-1 6.2.8 (6.30) 12 1 2 28 1 Begin EN3-1-1 6.2.8 (6.30) Opmerkingen: [ 46] T.b.v. kip is een equivalente Q-last berekend.
0.891 0.891 0.921 0.921 0.786
209 209 216 216 185
46 46 46 46
0.323 0.323
76 76
46 46
Bijlagen V001 - 106 van 248
Bijlagen V001 - 107 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
LIGGER:Tussen str 1-2 OMHULLENDE VAN DE FUNDAMENTELE COMBINATIES
Profiel : HEA300
GEOMETRIE
Ligger:Tussen str 1-2
MOMENTEN
Ligger:Tussen str 1-2 Fundamentele combinatie
292
-38.2
6.400 6.400 12.800 2:HEA300
VELDLENGTEN Veld 1 2
Vanaf 0.000 6.400
-318
Ligger:Tussen str 1-2 Tot 6.400 12.800
Lengte 6.400 6.400
DWARSKRACHTEN
VELDBELASTINGEN
Ligger:Tussen str 1-2 Fundamentele combinatie
259
Ligger:Tussen str 1-2 B.G:1 Permanent 169
34.7 -25.5
35.8
VELDBELASTINGEN Last Ref. 1 2
Type 1:q-last 1:q-last
Omschrijving q1 q2
VELDBELASTINGEN
Ligger:Tussen str 1-2 B.G:1 Permanent q1/p/m q2 psi Afstand Lengte 0.000 -35.800 0.000 12.800 0.000 -34.700 0.000 12.800
Ligger:Tussen str 1-2 B.G:2 Veranderlijk
REACTIES Stp 1 2 3
9
-288 274 457
Fmin:2.3 Fmax:25.5
Fmin 2.32 274.21 142.80
Fmax 25.54 456.68 259.45
143 259
Ligger:Tussen str 1-2 Fundamentele combinatie Mmin Mmax 0.00 0.00 0.00 0.00 0.00 0.00
9.3
VELDBELASTINGEN Last Ref. 1 2
Type 1:q-last 1:q-last
Ligger:Tussen str 1-2 B.G:2 Veranderlijk Omschrijving q1/p/m q2 psi Afstand Lengte q1 0.000 -9.300 0.000 12.800 q2 0.000 -9.000 0.000 12.800
GUNSTIGE WERKING PERMANENTE BELASTINGEN
Ligger:Tussen str 1-2
BC Velden met gunstige werking 1 1,2 2 1,2 Bijlagen V001 - 108 van 248
Bijlagen V001 - 109 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
OMHULLENDE VAN DE KARAKTERISTIEKE COMBINATIES
LIGGER:stramien 7
VERPLAATSINGEN
GEOMETRIE
[mm]
Ligger:Tussen str 1-2 Karakteristieke combinatie
Ligger:stramien 7
5.1
-0.74
.922 4.665 4.665 4.25
-24.1
KIPSTABILITEIT Staaf 1
Plts. aangr. 1.0*h
l gaffel [m] boven: 6.40 onder: 6.40
Staaf 2
Plts. aangr. 1.0*h
l gaffel [m] boven: 6.40 onder: 6.40
Kipsteunafstanden [m] 0 6.400
TOETSING DOORBUIGING
2
Veld 1 2 3 4 5 11
Vanaf 0.000 0.922 5.587 10.252 14.502 42.834
Tot 0.922 5.587 10.252 14.502 18.502 47.917
Lengte 0.922 4.665 4.665 4.250 4.000 5.083
Veld 6 7 8 9 10
Vanaf 18.502 22.502 27.585 32.668 37.751
Tot 22.502 27.585 32.668 37.751 42.834
Ligger:stramien 7 Lengte 4.000 5.083 5.083 5.083 5.083
Tot 53.000
Lengte 5.083
Veld
Vanaf
Tot
Ligger:stramien 7 Lengte
VELDLENGTEN Veld 12
Ligger:Tussen str 1-2 Staaf Mat BC Sit Kl Plaats Norm Artikel Formule Hoogste toetsing Opm. nr. U.C. [N/mm 2 ] 1 2 2 2 1 Staaf EN3-1-1 6.3.2 (6.54) 0.922 217 46 2 2 2 6 1 My-max EN3-1-1 6.2.5 (6.12y) 0.978 230 46 Opmerkingen: [ 46] T.b.v. kip is een equivalente Q-last berekend.
1
5.083 5.083 5.083 5.083 5.083 5.083 53.000 3:HEA260
Ligger:Tussen str 1-2 Kipsteunafstanden [m] 0 6.400
TOETSING SPANNINGEN
Staaf
4
VELDLENGTEN
Ligger:Tussen str 1-2
KIPSTABILITEIT
4
Soort Mtg Lengte Overst Zeeg ut o t BC Sit [m] I J [mm] [mm] Vloer db 6.40 N N 0.0 5.1 3 3 Eind db 3 3 Bijk Vloer db 6.40 N N 0.0 -24.1 3 3 Eind db 3 3 Bijk
Ligger:Tussen str 1-2 u Toelaatbaar [mm] [mm] *l 5.1 ±25.6 0.004 2.3 ±19.2 0.003 -24.1 ±25.6 0.004 -5.6 ±19.2 0.003
Vanaf 47.917
VELDBELASTINGEN
Ligger:stramien 7 B.G:1 Permanent
40
VELDBELASTINGEN Last Ref. 1
Type 1:q-last
Ligger:stramien 7 B.G:1 Permanent q1/p/m q2 psi Afstand Lengte -40.000 -40.000 0.000 53.000
Omschrijving
VELDBELASTINGEN
Ligger:stramien 7 B.G:2 Veranderlijk
10
VELDBELASTINGEN Last Ref. 1
Type 1:q-last
Omschrijving
Ligger:stramien 7 B.G:2 Veranderlijk q1/p/m q2 psi Afstand Lengte -10.000 -10.000 0.000 53.000
GUNSTIGE WERKING PERMANENTE BELASTINGEN
Ligger:stramien 7
BC Velden met gunstige werking 1 1-12 2 1-12 Bijlagen V001 - 110 van 248
Bijlagen V001 - 111 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
OMHULLENDE VAN DE FUNDAMENTELE COMBINATIES
DWARSKRACHTEN
Ligger:stramien 7 Fundamentele combinatie
Velden: 8 t/m 12
MOMENTEN
Ligger:stramien 7 Fundamentele combinatie
Velden: 1 t/m 7
170
167
177
167
132 153
147
125
110
101
87
27.1
-47.0
-55
-60
-66
Fmin:203 Fmax:343
MOMENTEN
Ligger:stramien 7 Fundamentele combinatie
Velden: 8 t/m 12
-161
-171
152
147
-82
-84
140
-73
-88
196 335
200 341
191 328
REACTIES Stp 1 2 3 4 5 6 7 8 9 10 11 12
180 153
-168
-170 -89
-104
Fmin 109.87 202.32 168.22 160.25 145.67 176.26 203.00 196.34 200.14 190.54 225.07 69.36
-198 225 374
69 132
Ligger:stramien 7 Fundamentele combinatie Mmin Mmax 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fmax 186.72 337.92 290.69 278.23 258.23 306.71 342.68 335.25 341.36 327.72 374.34 131.94
-136
OMHULLENDE VAN DE KARAKTERISTIEKE COMBINATIES DWARSKRACHTEN
Ligger:stramien 7 Fundamentele combinatie
VERPLAATSINGEN
Velden: 1 t/m 7
[mm]
Ligger:stramien 7 Karakteristieke combinatie
Velden: 1 t/m 7 176 147
172 140
131
144
4.36
59 0.46
0.15
-3.43 -128 Fmin:110 Fmax:187
-162 202 338
-144 168 291
-138 160 278
-127 146 258
-163 176 307
-6.9
0.12
-2.78
-2.33
0.63
0.09
-1.68 -6.2
203 343
Bijlagen V001 - 112 van 248
Bijlagen V001 - 113 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
VERPLAATSINGEN
[mm]
Ligger:stramien 7 Karakteristieke combinatie
Velden: 8 t/m 12
0.25
0.98
0.22
-4.20 -5.3
-5.5
-6.0
-11.0
KIPSTABILITEIT Staaf 1
Plts. aangr. 1.0*h
2
1.0*h
3
1.0*h
4
1.0*h
5
1.0*h
6
1.0*h
7
1.0*h
8
1.0*h
9
1.0*h
10
1.0*h
11
1.0*h
12
1.0*h
Ligger:stramien 7
boven: onder: boven: onder: boven: onder: boven: onder: boven: onder:
l gaffel [m] 1.84 1.84 4.66 4.66 4.66 4.66 4.25 4.25 4.00 4.00
Kipsteunafstanden [m] 0 0.922 0 4.665 0 4.665 0 4.250 0 4.000
boven: onder: boven: onder: boven: onder: boven: onder: boven: onder:
4.00 4.00 5.08 5.08 5.08 5.08 5.08 5.08 5.08 5.08
0 4.000 0 5.083 0 5.083 0 5.083 0 5.083
boven: onder: boven: onder:
5.08 5.08 5.08 5.08
0 5.083 0 5.083
TOETSING SPANNINGEN 2 2 2 2 2
2 10 10 12 14
1 1 1 1 1
Einde Einde Begin Begin Begin
EN3-1-1 EN3-1-1 EN3-1-1 EN3-1-1 EN3-1-1
6.2.6 6.2.8 6.2.8 6.2.8 6.2.8
(6.17) (6.30) (6.30) (6.30) (6.30)
6 7 8 9 10
2 2 2 2 2
18 20 20 24 24
1 1 1 1 1
Einde Einde Begin Einde Begin
EN3-1-1 EN3-1-1 EN3-1-1 EN3-1-1 EN3-1-1
6.2.8 6.2.8 6.2.8 6.2.8 6.2.8
(6.30) (6.30) (6.30) (6.30) (6.30)
0.576 0.707 0.707 0.702 0.702
135 166 166 165 165
EN3-1-1 6.2.8 EN3-1-1 6.2.8
(6.30) (6.30)
0.831 0.831
195 195
3 3 3 3 3
Sit Kl Plaats Norm Artikel
11 3 2 12 3 2 Opmerkingen: [ 4] Controle [ 8] Controle
28 1 Einde 28 1 Begin
Formule
Ligger:stramien 7 Hoogste toetsing Opm. U.C. [N/mm 2 ] 0.151 20 8,4 0.680 160 0.680 160 0.510 120 0.466 110
Staaf Mat BC nr. 1 3 2 3 3 3 4 3 5 3
gedrukte T-rand houdt geen rekening met 2e-orde-wringing. van de gedrukte rand is toegepast (zonder buiging!).
TOETSING DOORBUIGING Staaf
Soort Mtg Lengte Overst Zeeg [m] I J [mm] Vloer ss 0.92 J N 0.0 ss Vloer db 4.67 N N 0.0 db Vloer db 4.67 N N 0.0 db Vloer db 4.25 N N 0.0 db Vloer db 4.00 N N 0.0 db
ut o t BC Sit [mm] 4.4 3 3 Eind 3 3 Bijk -6.9 3 3 Eind 3 3 Bijk -3.4 3 2 Eind 3 2 Bijk -2.8 3 3 Eind 3 3 Bijk -2.3 3 2 Eind 3 2 Bijk
6
Vloer
7
Vloer
8
Vloer
9
Vloer
10
Vloer
11
Vloer
12
Vloer
1 2 3 4 5
Bijlagen V001 - 114 van 248
db db db db db db db db db db
4.00
N
N
0.0
-1.7
5.08
N
N
0.0
-6.2
5.08
N
N
0.0
-5.3
5.08
N
N
0.0
-5.5
5.08
N
N
0.0
-6.0
db db db db
5.08
N
N
0.0
-4.2
5.08
N
N
0.0 -11.0
Ligger:stramien 7 u Toelaatbaar [mm] [mm] *l 4.4 ±7.4 2*0.004 1.4 ±5.5 2*0.003 -6.9 ±18.7 0.004 -2.1 ±14.0 0.003 -3.4 ±18.7 0.004 -1.6 ±14.0 0.003 -2.8 ±17.0 0.004 -1.2 ±12.8 0.003 -2.3 ±16.0 0.004 -1.0 ±12.0 0.003
3 3 3 3 3 3 3 3 3 3
3 2 2 2 3 3 2 2 3 3
Eind Bijk Eind Bijk Eind Bijk Eind Bijk Eind Bijk
-1.7 1.3 -6.2 -2.2 -5.3 -2.3 -5.5 -2.3 -6.0 -2.4
±16.0 ±12.0 ±20.3 ±15.2 ±20.3 ±15.2 ±20.3 ±15.2 ±20.3 ±15.2
0.004 0.003 0.004 0.003 0.004 0.003 0.004 0.003 0.004 0.003
3 3 3 3
2 3 3 3
Eind Bijk Eind Bijk
-4.2 3.0 -11.0 -3.0
±20.3 ±15.2 ±20.3 ±15.2
0.004 0.003 0.004 0.003
Bijlagen V001 - 115 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
LIGGER:stramien A/1-4 OMHULLENDE VAN DE FUNDAMENTELE COMBINATIES GEOMETRIE
Ligger:stramien A/1-4
MOMENTEN
Ligger:stramien A/1-4 Fundamentele combinatie
142 121 77
70 4.5 5.250 5.250 5.000 5.000 25.000 4:HEA240
-17.2
VELDLENGTEN Veld 1 2 3 4 5
Vanaf 0.000 4.500 9.750 15.000 20.000
-40.6
Ligger:stramien A/1-4 Tot 4.500 9.750 15.000 20.000 25.000
-64
Lengte 4.500 5.250 5.250 5.000 5.000
VELDBELASTINGEN
-68 -92
DWARSKRACHTEN
Ligger:stramien A/1-4 Fundamentele combinatie
147
Ligger:stramien A/1-4 B.G:1 Permanent
152
q1=1.536.2
q2=36.2
83
75
61 q3=4.5 q4=36.2 -15.0
VELDBELASTINGEN Last Ref. 1 2 3 4
Ligger:stramien A/1-4 B.G:1 Permanent Omschrijving q1/p/m q2 psi Afstand Lengte q1 -1.500 -36.200 0.000 9.300 q2 -36.200 -36.200 9.300 7.600 q3 -4.500 -4.500 16.900 7.150 q4 -36.200 -36.200 24.050 0.950
Type 1:q-last 1:q-last 1:q-last 1:q-last
VELDBELASTINGEN
9
VELDBELASTINGEN Last Ref. 1 2 3 4
Type 1:q-last 1:q-last 1:q-last 1:q-last
Ligger:stramien A/1-4 B.G:2 Veranderlijk
q2=9
q3=13.5q4=9
Ligger:stramien A/1-4 B.G:2 Veranderlijk Omschrijving q1/p/m q2 psi Afstand Lengte q1 0.000 -9.000 0.000 9.300 q2 -9.000 -9.000 9.300 7.600 q3 -13.500 -13.500 16.900 7.150 q4 -9.000 -9.000 24.050 0.950
GUNSTIGE WERKING PERMANENTE BELASTINGEN
-84
-96 -131 Fmin:3.7 Fmax:15.0
-162 184 309
89 157
REACTIES Stp 1 2 3 4 5 6
Fmin 3.73 89.45 184.31 157.16 40.24 28.19
Fmax 14.99 156.96 308.98 282.73 159.33 83.26
157 283
40.2 159
28.2 83
Ligger:stramien A/1-4 Fundamentele combinatie Mmin Mmax 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Ligger:stramien A/1-4
BC Velden met gunstige werking 1 1-5 2 1-5 Bijlagen V001 - 116 van 248
Bijlagen V001 - 117 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
OMHULLENDE VAN DE KARAKTERISTIEKE COMBINATIES LIGGER:stramien A/4-7 VERPLAATSINGEN
[mm]
Ligger:stramien A/1-4 Karakteristieke combinatie
GEOMETRIE
Ligger:stramien A/4-7
2.81 1.01
0.44
0.28
-1.08 -3.03
5.000 5.000 5.000 5.000 5.000 5.000 30.000 5:HEA140
-6.2 -7.1 -9.5
KIPSTABILITEIT Staaf 1
Plts. aangr. 1.0*h
2
1.0*h
3
1.0*h
4
1.0*h
5
1.0*h
Ligger:stramien A/1-4
boven: onder: boven: onder: boven: onder: boven: onder: boven: onder:
l gaffel [m] 4.50 4.50 5.25 5.25 5.25 5.25 5.00 5.00 5.00 5.00
Kipsteunafstanden [m] 4.500 4.500 5.250 5.250 5.250 5.250 5.000 5.000 5.000 5.000
TOETSING SPANNINGEN Staaf Mat BC nr. 1 4 2 4 3 4 4 4 5 4 Opmerkingen: [ 46] T.b.v.
Sit Kl Plaats Norm Artikel 2 2 2 2 2
8 10 10 12 14
1 1 1 1 1
Staaf Staaf Staaf Staaf Staaf
EN3-1-1 EN3-1-1 EN3-1-1 EN3-1-1 EN3-1-1
6.3.2 6.3.2 6.3.2 6.3.2 6.3.2
Formule (6.54) (6.54) (6.54) (6.54) (6.54)
1 2 3 4 5
Veld 1 2 3 4 5
Vanaf 0.000 5.000 10.000 15.000 20.000
Tot 5.000 10.000 15.000 20.000 25.000
Lengte 5.000 5.000 5.000 5.000 5.000
Veld 6
VELDBELASTINGEN
Vanaf 25.000
Ligger:stramien A/4-7 Tot Lengte 30.000 5.000
Ligger:stramien A/4-7 B.G:1 Permanent
5.4
Ligger:stramien A/1-4 Hoogste toetsing Opm. U.C. [N/mm 2 ] 0.407 96 46 0.890 209 46 0.904 212 0.740 174 46 0.482 113 46
VELDBELASTINGEN Last Ref. 1
Type 1:q-last
Omschrijving
VELDBELASTINGEN
Ligger:stramien A/4-7 B.G:1 Permanent q1/p/m q2 psi Afstand Lengte -5.400 -5.400 0.000 30.000
Ligger:stramien A/4-7 B.G:2 Veranderlijk
1
kip is een equivalente Q-last berekend.
VELDBELASTINGEN
TOETSING DOORBUIGING Staaf
VELDLENGTEN
Soort Mtg Lengte Overst Zeeg [m] I J [mm] Vloer db 4.50 N N 0.0 db Vloer db 5.25 N N 0.0 db Vloer db 5.25 N N 0.0 db Vloer db 5.00 N N 0.0 db Vloer db 5.00 N N 0.0 db
ut o t BC [mm] -1.1 3 3 -6.2 3 3 -9.5 3 3 -3.0 3 3 -7.1 3 3
Ligger:stramien A/1-4 Sit u Toelaatbaar [mm] [mm] *l 2 Eind -1.1 ±18.0 0.004 3 Bijk 1.4 ±13.5 0.003 3 Eind -6.2 ±21.0 0.004 3 Bijk -2.4 ±15.8 0.003 2 Eind -9.5 ±21.0 0.004 2 Bijk -3.2 ±15.8 0.003 3 Eind -3.0 ±20.0 0.004 3 Bijk -3.7 ±15.0 0.003 2 Eind -7.1 ±20.0 0.004 2 Bijk -4.8 ±15.0 0.003 Bijlagen V001 - 118 van 248
Last Ref. 1
Type 1:q-last
Ligger:stramien A/4-7 B.G:2 Veranderlijk Omschrijving q1/p/m q2 psi Afstand Lengte -1.000 -1.000 0.000 30.000
GUNSTIGE WERKING PERMANENTE BELASTINGEN
Ligger:stramien A/4-7
BC Velden met gunstige werking 1 1-6 2 1-6
Bijlagen V001 - 119 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
OMHULLENDE VAN DE FUNDAMENTELE COMBINATIES
OMHULLENDE VAN DE KARAKTERISTIEKE COMBINATIES
MOMENTEN
VERPLAATSINGEN
Ligger:stramien A/4-7 Fundamentele combinatie
22.4
22.4 19.0
17.2
[mm]
Ligger:stramien A/4-7 Karakteristieke combinatie
0.97
0.97
0.13
17.2
-4.74
-4.74 -6.8
-8.7
-10.5
-8.7
-10.5
-16.9
-16.9
DWARSKRACHTEN
Ligger:stramien A/4-7 Fundamentele combinatie
-13.4
21.7
20.3
16.7
-16.7 -22.4 Fmin:9.6 Fmax:16.7
30.2 47.6
22.4
21.0
-21.0 25.5 41.3
-21.7 27.1 43.5
-13.4
KIPSTABILITEIT Staaf
25.2
-6.8
1
Plts. aangr. 1.0*h
2
1.0*h
3
1.0*h
4
1.0*h
5
1.0*h
6
1.0*h
boven: onder: boven: onder: boven: onder: boven: onder: boven: onder:
Ligger:stramien A/4-7 l gaffel [m] 5.00 5.00 5.00 5.00 5.00 5.00 5.00 5.00 5.00 5.00
Kipsteunafstanden [m] 5.000 5.000 5.000 5.000 5.000 5.000 5.000 5.000 5.000 5.000
-20.3 25.5 41.3
-25.2 30.2 47.6
9.6 16.7
boven: onder:
5.00 5.000 5.00 5.000
TOETSING SPANNINGEN REACTIES Stp 1 2 3 4 5 6 7
Fmin 9.62 30.21 25.53 27.08 25.53 30.21 9.62
Fmax 16.71 47.58 41.29 43.47 41.29 47.58 16.71
Ligger:stramien A/4-7 Fundamentele combinatie Mmin Mmax 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Bijlagen V001 - 120 van 248
Staaf Mat BC nr. 1 5 2 5 3 5 4 5 5 5
2 8 1 Staaf 2 8 1 Staaf 2 12 1 Staaf 2 12 1 Staaf 2 16 1 Staaf
EN3-1-1 EN3-1-1 EN3-1-1 EN3-1-1 EN3-1-1
6.3.2 6.3.2 6.3.2 6.3.2 6.3.2
(6.54) (6.54) (6.54) (6.54) (6.54)
6
2 16 1 Staaf
EN3-1-1 6.3.2
(6.54)
5
Sit Kl Plaats Norm Artikel
Formule
Ligger:stramien A/4-7 Hoogste toetsing Opm. U.C. [N/mm 2 ] 0.648 152 0.639 150 0.547 129 0.547 129 0.639 150 0.648
152
Bijlagen V001 - 121 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
TOETSING DOORBUIGING Staaf 1 2 3 4 5
6
Soort Mtg Lengte Overst Zeeg ut o t BC Sit [m] I J [mm] [mm] Vloer db 5.00 N N 0.0 -13.4 3 2 Eind db 3 2 Bijk Vloer db 5.00 N N 0.0 -4.7 3 3 Eind db 3 3 Bijk Vloer db 5.00 N N 0.0 -6.8 3 2 Eind db 3 2 Bijk Vloer db 5.00 N N 0.0 -6.8 3 3 Eind db 3 3 Bijk Vloer db 5.00 N N 0.0 -4.7 3 2 Eind db 3 2 Bijk Vloer
db db
5.00
N
N
0.0 -13.4
3 3
3 Eind 3 Bijk
Ligger:stramien A/4-7 u Toelaatbaar [mm] [mm] *l -13.4 ±20.0 0.004 -2.8 ±15.0 0.003 -4.7 ±20.0 0.004 -2.1 ±15.0 0.003 -6.8 ±20.0 0.004 -2.3 ±15.0 0.003 -6.8 ±20.0 0.004 -2.3 ±15.0 0.003 -4.7 ±20.0 0.004 -2.1 ±15.0 0.003 -13.4 -2.8
±20.0 ±15.0
0.004 0.003
LIGGER:stramien H GEOMETRIE
Ligger:stramien H
7.000 7.000 1
4
4
5
5
5.550 4.45 41.400 5:HEA140
5
5
3.4
VELDLENGTEN Veld 1 2 3 4 5
Vanaf 0.000 7.000 11.000 15.000 20.000
Tot 7.000 11.000 15.000 20.000 25.000
Lengte 7.000 4.000 4.000 5.000 5.000
Veld 6 7 8 9 10
Vanaf 25.000 30.550 35.000 40.000 45.000
Tot 30.550 35.000 40.000 45.000 48.400
DOORSNEDEN sector 1 2 sector 1 2
Vanaf Tot 0.000 7.000 7.000 48.400 Vanaf Tot 0.000 7.000 7.000 48.400
Lengte Profiel begin z-begin 7.000 1:HEA220 0.000 41.400 5:HEA140 0.000 Lengte Eindcode Bedding Br.[mm] 7.000 1:Vast 41.400 1:Vast
VELDBELASTINGEN
Ligger:stramien H Lengte 5.550 4.450 5.000 5.000 3.400
Ligger:stramien H Profiel eind z-eind 1:HEA220 0.000 5:HEA140 0.000
Ligger:stramien H B.G:1 Permanent
5.4
VELDBELASTINGEN Last Ref. 1
Type 1:q-last
Omschrijving
VELDBELASTINGEN
Ligger:stramien H B.G:1 Permanent q1/p/m q2 psi Afstand Lengte -5.400 -5.400 0.000 48.400 Ligger:stramien H B.G:2 Veranderlijk
1
VELDBELASTINGEN Last Ref. 1
Type 1:q-last
Omschrijving
Ligger:stramien H B.G:2 Veranderlijk q1/p/m q2 psi Afstand Lengte -1.000 -1.000 0.000 48.400
GUNSTIGE WERKING PERMANENTE BELASTINGEN
Ligger:stramien H
BC Velden met gunstige werking 1 1-10 2 1-10 Bijlagen V001 - 122 van 248
Bijlagen V001 - 123 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
OMHULLENDE VAN DE FUNDAMENTELE COMBINATIES
DWARSKRACHTEN
Ligger:stramien H Fundamentele combinatie
Velden: 6 t/m 10
MOMENTEN
Ligger:stramien H Fundamentele combinatie
Velden: 1 t/m 5
23.1
22.1
18.5
20.5 10.4
23.5
21.2
18.0
16.4 8.3
-3.8
-6.8
-9.0
-10.9
-42.7
-20.5
26.6 43.2
Ligger:stramien H Fundamentele combinatie
Velden: 6 t/m 10
19.1
19.4
15.4
-6.3
-6.6
-10.3
-10.8
-14.0
15.3
Stp 1 2 3 4 5 6 7 8 9 10 11
Fmin 16.28 34.41 16.98 24.83 26.34 28.70 26.62 23.78 27.78 24.44 5.30
-18.6
-21.8
23.8 38.9
REACTIES
MOMENTEN
21.2
-20.0
-23.8 Fmin:28.7 Fmax:45.8
27.8 43.9
24.4 39.0
5.3 10.4
Ligger:stramien H Fundamentele combinatie Mmin Mmax 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fmax 27.07 54.50 28.98 40.26 42.27 45.82 43.19 38.95 43.92 39.03 10.44
OMHULLENDE VAN DE KARAKTERISTIEKE COMBINATIES DWARSKRACHTEN
Ligger:stramien H Fundamentele combinatie
Velden: 1 t/m 5
VERPLAATSINGEN
[mm]
Ligger:stramien H Karakteristieke combinatie
Velden: 1 t/m 5 33.4
2.23
19.2
0.42
22.0
21.5
13.6
0.72
0.02
-0.36 -2.75 -5.1 -7.4
-15.4 -21.1 -27.1 Fmin:16.3 Fmax:27.1
34.4 54
-21.0 17.0 29.0
24.8 40.3
-20.8 26.3 42.3
28.7 45.8
Bijlagen V001 - 124 van 248
-14.4
Bijlagen V001 - 125 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
VERPLAATSINGEN
[mm]
Ligger:stramien H Karakteristieke combinatie
TOETSING DOORBUIGING Staaf
Velden: 6 t/m 10
1 1.27
0.35
0.11
2 -2.03
-2.33
4
-6.7
-7.2
3
5
Soort Mtg Lengte Overst Zeeg ut o t BC Sit [m] I J [mm] [mm] Vloer db 7.00 N N 0.0 -14.4 3 2 Eind db 3 2 Bijk Vloer db 4.00 N N 0.0 2.2 3 2 Eind db 3 2 Bijk Vloer db 4.00 N N 0.0 -2.8 3 2 Eind db 3 2 Bijk Vloer db 5.00 N N 0.0 -7.4 3 3 Eind db 3 3 Bijk Vloer db 5.00 N N 0.0 -5.1 3 2 Eind db 3 2 Bijk
Ligger:stramien H u Toelaatbaar [mm] [mm] *l -14.4 ±28.0 0.004 -2.4 ±21.0 0.003 2.2 ±16.0 0.004 0.9 ±12.0 0.003 -2.8 ±16.0 0.004 -1.1 ±12.0 0.003 -7.4 ±20.0 0.004 -2.1 ±15.0 0.003 -5.1 ±20.0 0.004 -2.1 ±15.0 0.003
-12.0
KIPSTABILITEIT Staaf 1
Plts. aangr. 1.0*h
2
1.0*h
3
1.0*h
4
1.0*h
5
1.0*h
6
1.0*h
7
1.0*h
8
1.0*h
9
1.0*h
10
1.0*h
boven: onder: boven: onder: boven: onder: boven: onder: boven: onder: boven: onder: boven: onder: boven: onder: boven: onder: boven: onder:
l gaffel [m] 7.00 7.00 4.00 4.00 4.00 4.00 5.00 5.00 5.00 5.00 5.55 5.55 4.45 4.45 5.00 5.00 5.00 5.00 3.40 3.40
Kipsteunafstanden [m] 0 7.000 0 4.000 0 4.000 0 5.000 0 5.000 0 5.55 0 4.45 0 5.000 0 5.000 0 3.4
Staaf Mat BC nr. 1 1 2 5 3 5 4 5 5 5
2 4 1 My-max 2 8 1 Staaf 2 12 1 Einde 2 14 1 Einde 2 16 1 Einde
EN3-1-1 EN3-1-1 EN3-1-1 EN3-1-1 EN3-1-1
6.2.5 6.3.2 6.2.8 6.2.8 6.2.8
Ligger:stramien H Hoogste toetsing Opm. U.C. [N/mm 2 ] (6.12y) 0.319 75 (6.54) 0.624 147 (6.30) 0.402 94 (6.30) 0.441 104 (6.30) 0.521 122
6 7 8 9 10
2 1 2 2 2
EN3-1-1 EN3-1-1 EN3-1-1 EN3-1-1 EN3-1-1
6.2.8 6.3.2 6.2.8 6.2.8 6.2.8
(6.30) (6.54) (6.30) (6.30) (6.30)
Sit Kl Plaats Norm Artikel
16 21 22 22 24
1 1 1 1 1
Vloer
7
Vloer
8
Vloer
9
Vloer
10
Vloer
Ligger:stramien H
TOETSING SPANNINGEN
5 5 5 5 5
6
Begin Staaf Einde Begin Begin
db db db db db db db db db db
5.55
N
N
0.0 -12.0
4.45
N
N
0.0
-2.3
5.00
N
N
0.0
-7.2
5.00
N
N
0.0
-6.7
3.40
N
N
0.0
-2.0
3 3 3 3 3 3 3 3 3 3
3 3 2 3 3 3 2 2 3 3
Eind Bijk Eind Bijk Eind Bijk Eind Bijk Eind Bijk
-12.0 -3.1 -2.3 2.0 -7.2 -2.1 -6.7 -1.9 -2.0 -0.7
±22.2 ±16.7 ±17.8 ±13.4 ±20.0 ±15.0 ±20.0 ±15.0 ±13.6 ±10.2
0.004 0.003 0.004 0.003 0.004 0.003 0.004 0.003 0.004 0.003
Formule
0.521 0.493 0.475 0.475 0.376
122 116 112 112 88
Bijlagen V001 - 126 van 248
Bijlagen V001 - 127 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
2
PROFIELEN vervolg [mm]
DAKLIGGERS (THQ)
TS/Liggers Project......: Onderdeel....: Constructeur.: Opdrachtgever: Dimensies....: Datum........: Bestand......:
Rel: 5.27c 19 apr 2013 130583 - Saturn Duiven THQ-LIGGERS DAK ENN Bouwontwikkeling Jongen BV kN/m/rad 02/04/2013 m:\bouw\projecten\130583 saturn duiven\4_berekeningen\ dakliggers thq.dlw
Betrouwbaarheidsklasse
: 2
Referentieperiode
: 50
Toegepaste normen volgens Eurocode met Nederlandse NB Belastingen Staal
NEN-EN 1990:2002 NEN-EN 1991-1-1:2002 NEN-EN 1993-1-1:2006
C2:2010 C1:2009 C2:2009
NB:2011(nl) NB:2011(nl) NB:2011(nl)
Prof. Vormf. Breedte Hoogte 1 0.00 100 327 2 0.00 300 300
ey 163.5 150.0
Type
DOORSNEDEN sector 1 2 3 sector 1 2 3
Vanaf 0.000 26.300 44.100 Vanaf 0.000 26.300 44.100
Tot 26.300 44.100 59.800 Tot 26.300 44.100 59.800
Lengte Profiel begin z-begin 26.300 1:STRIP100*327 0.000 17.800 1:STRIP100*327 0.000 15.700 2:HEB300 0.000 Lengte Eindcode Bedding Br.[mm] 26.300 0:Scharnier 17.800 0:Scharnier 15.700 1:Vast
GEOMETRIE
B.G. Omschrijving 1 Permanent 2 Parkeren
Belast/onbelast 2:Permanent EN1991 1:Schaakbord EN1991
q1=57.8
VELDBELASTINGEN Last Ref. 1 2 3 4 5
6.500 10.000 15.700 2:HEB300
Type 1:q-last 1:q-last 1:q-last 1:q-last 8:Puntlast
Omschrijving q1 q2 q3 q2 F1
VELDBELASTINGEN VELDLENGTEN Veld 1 2 3 4 5
Vanaf 0.000 3.100 7.600 12.100 16.000
Tot 3.100 7.600 12.100 16.000 21.150
Lengte 3.100 4.500 4.500 3.900 5.150
Veld 6 7 8 9 10
Vanaf 21.150 26.300 34.800 43.300 49.800
Tot 26.300 34.800 43.300 49.800 59.800
Ligger:STR 2 (VOL) Lengte 5.150 8.500 8.500 6.500 10.000
MATERIALEN Mt Omschrijving E-mechanica[N/mm2] Cement 1 S355 210000 2 S235 210000
Kruipcoef. S.M. S.M.verh. Pois. 78.5 0.30 78.5 0.30
b2
h2
Ligger:STR 2 (VOL) Profiel eind z-eind 1:STRIP100*327 0.000 1:STRIP100*327 0.000 2:HEB300 0.000
Type 1:q-last 1:q-last 1:q-last 1:q-last 8:Puntlast
1
2
e.g. -1.00 0.00
0.70 0.70 0.60
F1=162 q2=34.7
q3=4.5 q2=34.7
Ligger:STR 2 (VOL) B.G:1 Permanent q1/p/m q2 psi Afstand Lengte -57.800 -57.800 0.000 44.100 -34.700 -34.700 44.100 7.600 -4.500 -4.500 51.700 7.200 -34.700 -34.700 58.900 0.900 -162.000 44.100 Ligger:STR 2 (VOL) B.G:2 Parkeren
q1=15
F1=43 q2=9
Omschrijving q1 q2 q3 q2 F1
Ligger:STR 2 (VOL) B.G:2 Parkeren q1/p/m q2 psi Afstand Lengte -15.000 -15.000 0.000 44.100 -9.000 -9.000 44.100 7.600 -13.500 -13.500 51.700 7.200 -9.000 -9.000 58.900 0.900 -43.000 44.100
VELDBELASTINGEN Last Ref. 1 2 3 4 5
0
Ligger:STR 2 (VOL) B.G:1 Permanent
Ligger:STR 2 (VOL)
3.1 4.5 4.5 3.9 5.15 5.15 8.500 8.500 26.300 17.800 1:STRIP100*327
h1
BELASTINGGEVALLEN
VELDBELASTINGEN
LIGGER:STR 2 (VOL)
b1
q3=13.5 q2=9
PROFIELEN [mm] Prof. Omschrijving 1 STRIP100*327 2 HEB300
Materiaal 1:S355 2:S235
Oppervlak Traagheid 3.2700e+004 2.9138e+008 1.4910e+004 2.5170e+008 Bijlagen V001 - 128 van 248
Bijlagen V001 - 129 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
BELASTINGCOMBINATIES BC 1 2 3 4 5
Type Fund. Fund. Kar. Quas. Perm.
BG 1 1 1 1 1
Gen. Factor Perm 1.35 Perm 1.20 Perm 1.00 Extr 1.00 Perm 1.00
BG 2 2 2 2
DWARSKRACHTEN Gen. Factor psi0 1.50 Extr 1.50 Extr 1.00 psi2 1.00
BG Gen. Factor
BG Gen. Factor
509
198
GUNSTIGE WERKING PERMANENTE BELASTINGEN
230
279
216
203
199
Ligger:STR 2 (VOL)
BC Velden met gunstige werking 1 1-10 2 1-10
-112 -216
OMHULLENDE VAN DE FUNDAMENTELE COMBINATIES MOMENTEN
Ligger:STR 2 (VOL) Fundamentele combinatie
Velden: 1 t/m 7
Fmin:49.6250 Fmax:112 414
-194
-233 286 463
-233
239 410
251 436
-306 365 585
-328 310 527
616 985
Ligger:STR 2 (VOL) Fundamentele combinatie
Velden: 1 t/m 7
DWARSKRACHTEN 810
Ligger:STR 2 (VOL) Fundamentele combinatie
Velden: 8 t/m 10 370
287 183
146 -66
-99
-104
219
168
147 -64
137
-124
-204
-220 -555
MOMENTEN
Ligger:STR 2 (VOL) Fundamentele combinatie
-475 493 844
-476 Fmin:616 Fmax:985
227 440
39.6 137
Velden: 8 t/m 10
REACTIES 810
349
Stp 1 2 3 4 5 6 7 8 9 10 11
332
-154
-236
-407
Bijlagen V001 - 130 van 248
Fmin 49.65 249.75 285.72 238.57 250.70 364.55 310.15 616.30 492.91 226.50 39.58
Fmax 111.95 413.98 463.32 410.28 436.16 584.90 526.79 985.01 844.48 439.91 136.55
Ligger:STR 2 (VOL) Fundamentele combinatie Mmin Mmax 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Bijlagen V001 - 131 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
OMHULLENDE VAN DE KARAKTERISTIEKE COMBINATIES
MOMENTEN
Ligger:STR 2 (VOL) Quasi-Blijvende combinatie
Velden: 8 t/m 10
MOMENTEN
Ligger:STR 2 (VOL) Karakteristieke combinatie
Velden: 1 t/m 7
575 631
248
199
223 143
114
131
115
-108 -51
-77
-47.6
-81
-119
-268 -96
-160 -435
MOMENTEN
Ligger:STR 2 (VOL) Karakteristieke combinatie
Velden: 8 t/m 10
631
271
247
-120
-166
-311
OMHULLENDE VAN DE QUASI-BLIJVENDE COMBINATIES MOMENTEN
Ligger:STR 2 (VOL) Quasi-Blijvende combinatie
Velden: 1 t/m 7
575
204 130
104 -44.7
-68
102
-71
-38.7
117
-84
-144 -391
Bijlagen V001 - 132 van 248
Bijlagen V001 - 133 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
LIGGER:STR 3 (VOL)
OMHULLENDE VAN DE FUNDAMENTELE COMBINATIES
Profiel : STRIP100*327
MOMENTEN GEOMETRIE
Ligger:STR 3 (VOL) Fundamentele combinatie
Ligger:STR 3 (VOL) 650
634
647
647 513
6.500
8.000
8.000 8.000 44.000 1:STRIP100*327
8.000
5.500 -217 -363
-374
VELDLENGTEN Veld 1 2 3 4 5
Vanaf 0.000 6.500 14.500 22.500 30.500
Tot 6.500 14.500 22.500 30.500 38.500
Lengte 6.500 8.000 8.000 8.000 8.000
Veld 6
Vanaf 38.500
Tot 44.000
Ligger:STR 3 (VOL) Lengte 5.500
DWARSKRACHTEN 474
-359
-363
-370
Ligger:STR 3 (VOL) Fundamentele combinatie
475
476
470
428 208
VELDBELASTINGEN
Ligger:STR 3 (VOL) B.G:1 Permanent
q1=69.3
q2=69.3
60.4 -293 -381
VELDBELASTINGEN Last Ref. 1 2
Type 1:q-last 1:q-last
Omschrijving q1 q2
Ligger:STR 3 (VOL) B.G:1 Permanent q1/p/m q2 psi Afstand Lengte -69.300 -69.300 0.000 26.300 -69.300 -60.400 26.300 17.700
-474 584 948
Fmin:142 Fmax:293
-477 581 952
REACTIES VELDBELASTINGEN
Ligger:STR 3 (VOL) B.G:2 Parkeren
q1=18
q2=18
VELDBELASTINGEN Last Ref. 1 2
Type 1:q-last 1:q-last
Omschrijving q1 q2
15.7
Ligger:STR 3 (VOL) B.G:2 Parkeren q1/p/m q2 psi Afstand Lengte -18.000 -18.000 0.000 26.300 -18.000 -15.700 26.300 17.700
GUNSTIGE WERKING PERMANENTE BELASTINGEN
Stp 1 2 3 4 5 6 7
Fmin 141.85 584.13 580.56 576.82 571.91 484.46 89.36
Fmax 293.01 948.23 951.52 949.13 935.26 808.22 207.83
-474 577 949
-465 572 935
484 808
89 208
Ligger:STR 3 (VOL) Fundamentele combinatie Mmin Mmax 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Ligger:STR 3 (VOL)
BC Velden met gunstige werking 1 1-6 2 1-6
Bijlagen V001 - 134 van 248
Bijlagen V001 - 135 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
OMHULLENDE VAN DE KARAKTERISTIEKE COMBINATIES
LIGGER:STR 3 (HALF) Profiel : STRIP100*327
MOMENTEN
Ligger:STR 3 (VOL) Karakteristieke combinatie
GEOMETRIE 510
495
508
Ligger:STR 3 (HALF)
506 401
6.500
8.000
-167 -281
-292
-280
-285
8.000 8.000 44.000 1:STRIP100*327
8.000
Lengte 6.500 8.000 8.000 8.000 8.000
Vanaf 38.500
5.500
-279
VELDLENGTEN OMHULLENDE VAN DE QUASI-BLIJVENDE COMBINATIES MOMENTEN
Ligger:STR 3 (VOL) Quasi-Blijvende combinatie
460
449
458
457
363
Veld 1 2 3 4 5
Vanaf 0.000 6.500 14.500 22.500 30.500
Tot 6.500 14.500 22.500 30.500 38.500
Veld 6
VELDBELASTINGEN
q2=69.3
VELDBELASTINGEN -260
-245
-248
-243
-246
Last Ref. 1 2
Type 1:q-last 1:q-last
Omschrijving q1 q2
VELDBELASTINGEN
60.4
Ligger:STR 3 (HALF) B.G:1 Permanent q1/p/m q2 psi Afstand Lengte -69.300 -69.300 0.000 26.300 -69.300 -60.400 26.300 17.700 Ligger:STR 3 (HALF) B.G:2 Parkeren
q1=10
q2=10
VELDBELASTINGEN Last Ref. 1 2
Ligger:STR 3 (HALF) Lengte 5.500
Ligger:STR 3 (HALF) B.G:1 Permanent
q1=69.3
-146
Tot 44.000
Type 1:q-last 1:q-last
Omschrijving q1 q2
Ligger:STR 3 (HALF) B.G:2 Parkeren q1/p/m q2 psi Afstand Lengte -10.000 -10.000 0.000 26.300 -10.000 -10.000 26.300 17.700
GUNSTIGE WERKING PERMANENTE BELASTINGEN
Ligger:STR 3 (HALF)
BC Velden met gunstige werking 1 1-6 2 1-6
Bijlagen V001 - 136 van 248
Bijlagen V001 - 137 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
OMHULLENDE VAN DE FUNDAMENTELE COMBINATIES
OMHULLENDE VAN DE KARAKTERISTIEKE COMBINATIES
MOMENTEN
MOMENTEN
Ligger:STR 3 (HALF) Fundamentele combinatie
592
581
593
589
Ligger:STR 3 (HALF) Karakteristieke combinatie
454
444
455
452
363
473
-188 -311
-333
DWARSKRACHTEN 439
-308
-314
-316
Ligger:STR 3 (HALF) Fundamentele combinatie
436
436
433
-146 -241
-257
-240
-244
-245
OMHULLENDE VAN DE QUASI-BLIJVENDE COMBINATIES MOMENTEN
Ligger:STR 3 (HALF) Quasi-Blijvende combinatie
396 190
426
419
427
423
340
-268 -355 -436 556 874
Fmin:149 Fmax:268
-438 553 874
-435 549 871
-430 547 863
469 751
97 190
-133 -239
REACTIES Stp 1 2 3 4 5 6 7
Fmin 148.76 556.22 552.76 549.49 546.85 469.50 97.05
Fmax 267.73 874.40 874.15 871.46 863.29 751.26 189.91
-222
-223
-219
-226
Ligger:STR 3 (HALF) Fundamentele combinatie Mmin Mmax 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Bijlagen V001 - 138 van 248
Bijlagen V001 - 139 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
LIGGER:STR 4-5 (VOL)
OMHULLENDE VAN DE FUNDAMENTELE COMBINATIES
GEOMETRIE
Ligger:STR 4-5 (VOL)
MOMENTEN
Ligger:STR 4-5 (VOL) Fundamentele combinatie
722
702
6.500
8.000
8.000 8.000 44.000 1:STRIP100*327
8.000
738
716
619
5.500 -272
VELDLENGTEN Veld 1 2 3 4 5
Vanaf 0.000 6.500 14.500 22.500 30.500
-403
-415
Tot 6.500 14.500 22.500 30.500 38.500
Lengte 6.500 8.000 8.000 8.000 8.000
Veld 6
Vanaf 38.500
Tot 44.000
Ligger:STR 4-5 (VOL) Lengte 5.500
DWARSKRACHTEN 525
-401
-412
-423
Ligger:STR 4-5 (VOL) Fundamentele combinatie
526
527
531
512 261
VELDBELASTINGEN
Ligger:STR 4-5 (VOL) B.G:1 Permanent
q1=77
-325
VELDBELASTINGEN Last Ref. 1
Type 1:q-last
Ligger:STR 4-5 (VOL) B.G:1 Permanent Omschrijving q1/p/m q2 psi Afstand Lengte q1 -77.000 -77.000 0.000 44.000
VELDBELASTINGEN
-525 647 1050
Fmin:157 Fmax:325
-529 643 1055
20
VELDBELASTINGEN Type 1:q-last
-536 654 1067
-466 589 978
114 261
Ligger:STR 4-5 (VOL) B.G:2 Parkeren
REACTIES
Last Ref. 1
-524 637 1050
Omschrijving
Ligger:STR 4-5 (VOL) B.G:2 Parkeren q1/p/m q2 psi Afstand Lengte -20.000 -20.000 0.000 44.000
GUNSTIGE WERKING PERMANENTE BELASTINGEN
Stp 1 2 3 4 5 6 7
Fmin 157.00 646.83 643.19 637.29 654.19 589.22 114.32
Fmax 324.66 1050.39 1054.82 1050.39 1067.32 977.85 261.18
Ligger:STR 4-5 (VOL) Fundamentele combinatie Mmin Mmax 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Ligger:STR 4-5 (VOL)
BC Velden met gunstige werking 1 1-6 2 1-6
Bijlagen V001 - 140 van 248
Bijlagen V001 - 141 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
OMHULLENDE VAN DE KARAKTERISTIEKE COMBINATIES
LIGGER:STR 6 (VOL)
MOMENTEN
GEOMETRIE
Ligger:STR 4-5 (VOL) Karakteristieke combinatie
565
548
Ligger:STR 6 (VOL)
578
561
484
6.500
8.000
8.000
8.000 8.000 53.000 1:STRIP100*327
8.000
6.500
-210 -311
-324
-309
-317
-329
VELDLENGTEN
OMHULLENDE VAN DE QUASI-BLIJVENDE COMBINATIES MOMENTEN
Ligger:STR 4-5 (VOL) Quasi-Blijvende combinatie
510
498
522
505
Veld 1 2 3 4 5
Vanaf 0.000 6.500 14.500 22.500 30.500
Tot 6.500 14.500 22.500 30.500 38.500
Lengte 6.500 8.000 8.000 8.000 8.000
Veld 6 7
VELDBELASTINGEN
438
Vanaf 38.500 46.500
Tot 46.500 53.000
Ligger:STR 6 (VOL) Lengte 8.000 6.500
Ligger:STR 6 (VOL) B.G:1 Permanent
q1=77
VELDBELASTINGEN -183 -288
-272
-276
-268
-290
Last Ref. 1
Type 1:q-last
Omschrijving q1
VELDBELASTINGEN
Ligger:STR 6 (VOL) B.G:1 Permanent q1/p/m q2 psi Afstand Lengte -77.000 -77.000 0.000 53.000 Ligger:STR 6 (VOL) B.G:2 Parkeren
20
VELDBELASTINGEN Last Ref. 1
Type 1:q-last
Omschrijving
Ligger:STR 6 (VOL) B.G:2 Parkeren q1/p/m q2 psi Afstand Lengte -20.000 -20.000 0.000 53.000
GUNSTIGE WERKING PERMANENTE BELASTINGEN
Ligger:STR 6 (VOL)
BC Velden met gunstige werking 1 1-7 2 1-7
Bijlagen V001 - 142 van 248
Bijlagen V001 - 143 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
OMHULLENDE VAN DE FUNDAMENTELE COMBINATIES
DWARSKRACHTEN
Ligger:STR 6 (VOL) Fundamentele combinatie
Velden: 7 t/m 7
MOMENTEN
Ligger:STR 6 (VOL) Fundamentele combinatie
Velden: 1 t/m 6
325 725
721
703
725
721
703
-525 Fmin:647 Fmax:1051 -404
-415
-411
MOMENTEN
-413
-404
-411
157 325
REACTIES
Ligger:STR 6 (VOL) Fundamentele combinatie
Velden: 7 t/m 7
703
Stp 1 2 3 4 5 6 7 8
Fmin 156.91 646.93 641.93 638.85 638.85 641.93 646.93 156.91
Fmax 324.62 1050.83 1054.07 1056.38 1056.38 1054.07 1050.83 324.62
Ligger:STR 6 (VOL) Fundamentele combinatie Mmin Mmax 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
OMHULLENDE VAN DE KARAKTERISTIEKE COMBINATIES MOMENTEN
Ligger:STR 6 (VOL) Karakteristieke combinatie
Velden: 1 t/m 6 -415
DWARSKRACHTEN
Ligger:STR 6 (VOL) Fundamentele combinatie
568
565
549
568
565
549
Velden: 1 t/m 6
525
526
528
529
528
525
-324
-312
-316
-318
-316
-312
-325
Fmin:157 Fmax:325
-525 647 1051
-528 642 1054
-529 639 1056
-528 639 1056
-526 642 1054
647 1051
Bijlagen V001 - 144 van 248
Bijlagen V001 - 145 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
MOMENTEN
Ligger:STR 6 (VOL) Karakteristieke combinatie
LIGGER:STR 6 (HALF)
Velden: 7 t/m 7
GEOMETRIE
Ligger:STR 6 (HALF)
549
6.500
8.000
-324
Ligger:STR 6 (VOL) Quasi-Blijvende combinatie
Velden: 1 t/m 6
509
498
510
510
8.000 8.000 53.000 1:STRIP100*327
8.000
VELDLENGTEN
OMHULLENDE VAN DE QUASI-BLIJVENDE COMBINATIES MOMENTEN
8.000
509
Veld 1 2 3 4 5
Vanaf 0.000 6.500 14.500 22.500 30.500
Tot 6.500 14.500 22.500 30.500 38.500
Lengte 6.500 8.000 8.000 8.000 8.000
Veld 6 7
Vanaf 38.500 46.500
Tot 46.500 53.000
6.500
Ligger:STR 6 (HALF) Lengte 8.000 6.500
498
VELDBELASTINGEN
Ligger:STR 6 (HALF) B.G:1 Permanent
q1=77
VELDBELASTINGEN -288
-272
-275
-276
-275
-272
Last Ref. 1
Type 1:q-last
Omschrijving q1
VELDBELASTINGEN MOMENTEN
Ligger:STR 6 (HALF) B.G:1 Permanent q1/p/m q2 psi Afstand Lengte -77.000 -77.000 0.000 53.000 Ligger:STR 6 (HALF) B.G:2 Parkeren
Ligger:STR 6 (VOL) Quasi-Blijvende combinatie
Velden: 7 t/m 7 10
498
VELDBELASTINGEN Last Ref. 1
Type 1:q-last
Omschrijving
Ligger:STR 6 (HALF) B.G:2 Parkeren q1/p/m q2 psi Afstand Lengte -10.000 -10.000 0.000 53.000
GUNSTIGE WERKING PERMANENTE BELASTINGEN
Ligger:STR 6 (HALF)
BC Velden met gunstige werking 1 1-7 2 1-7 -288
Bijlagen V001 - 146 van 248
Bijlagen V001 - 147 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
OMHULLENDE VAN DE FUNDAMENTELE COMBINATIES
DWARSKRACHTEN
Ligger:STR 6 (HALF) Fundamentele combinatie
Velden: 7 t/m 7
MOMENTEN
Ligger:STR 6 (HALF) Fundamentele combinatie
Velden: 1 t/m 6
293 647
636
648
648
647
636
-481 Fmin:612 Fmax:958 -339
-364
-341
MOMENTEN
-341
-342
-339
166 293
REACTIES
Ligger:STR 6 (HALF) Fundamentele combinatie
Velden: 7 t/m 7 636
Stp 1 2 3 4 5 6 7 8
Fmin 165.58 612.15 607.58 605.83 605.83 607.58 612.15 165.58
Fmax 293.00 958.44 956.96 957.80 957.80 956.96 958.44 293.00
Ligger:STR 6 (HALF) Fundamentele combinatie Mmin Mmax 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
OMHULLENDE VAN DE KARAKTERISTIEKE COMBINATIES MOMENTEN
Ligger:STR 6 (HALF) Karakteristieke combinatie
Velden: 1 t/m 6 -364 495
485
DWARSKRACHTEN
496
496
495
485
Ligger:STR 6 (HALF) Fundamentele combinatie
Velden: 1 t/m 6
481
478
479
479
479
477
-279
-262
-264
-265
-264
-262
-293
Fmin:166 Fmax:293
-477 612 958
-479 608 957
-479 606 958
-479 606 958
-478 608 957
612 958
Bijlagen V001 - 148 van 248
Bijlagen V001 - 149 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
MOMENTEN
Ligger:STR 6 (HALF) Karakteristieke combinatie
3
VLOERLIGGERS (HE-PROFIELEN)
Velden: 7 t/m 7
TS/Liggers 485
Constructeur.: Dimensies....: Datum........: Bestand......:
Rel: 5.27c 19 apr 2013 ENN kN/m/rad 05/04/2013 m:\bouw\projecten\130583 saturn duiven\4_berekeningen\ vloerliggers.dlw
Betrouwbaarheidsklasse
: 2
Referentieperiode
: 50
Toegepaste normen volgens Eurocode met Nederlandse NB Belastingen
-279
Staal
NEN-EN 1990:2002 NEN-EN 1991-1-1:2002 NEN-EN 1993-1-1:2006
C2:2010 C1:2009 C2:2009
NB:2011(nl) NB:2011(nl) NB:2011(nl)
OMHULLENDE VAN DE QUASI-BLIJVENDE COMBINATIES LIGGER:stramien 1
MOMENTEN
Ligger:STR 6 (HALF) Quasi-Blijvende combinatie
Velden: 1 t/m 6
GEOMETRIE 467
460
467
467
467
Ligger:stramien 1
460
2.000
-262
-243
-243
-244
-243
4.650
4.650 15.950 1:HEA240
-243
VELDLENGTEN MOMENTEN
4.650
Ligger:STR 6 (HALF) Quasi-Blijvende combinatie
Velden: 7 t/m 7 460
Veld 1 2 3 4
Vanaf 0.000 2.000 6.650 11.300
Ligger:stramien 1 Tot 2.000 6.650 11.300 15.950
Lengte 2.000 4.650 4.650 4.650
MATERIALEN Mt Omschrijving E-mechanica[N/mm2] Cement 1 S235 210000
Kruipcoef. S.M. S.M.verh. Pois. 78.5 0.30
PROFIELEN [mm] Prof. 1 2 3 4 5 6
-262
Bijlagen V001 - 150 van 248
Omschrijving HEA240 HEA260 HEA160 HEA200 HEA360 HEA280
Materiaal 1:S235 1:S235 1:S235 1:S235 1:S235 1:S235
Oppervlak 7.6800e+003 8.6800e+003 3.8800e+003 5.3800e+003 1.4280e+004 9.7300e+003
Traagheid 7.7630e+007 1.0460e+008 1.6730e+007 3.6920e+007 3.3090e+008 1.3670e+008
Bijlagen V001 - 151 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
PROFIELEN vervolg [mm] Prof. Vormf. Breedte Hoogte 1 0.00 240 230 2 0.00 260 250 3 0.00 160 152 4 0.00 200 190 5 0.00 300 350 6 0.00 280 270
ey 115.0 125.0 76.0 95.0 175.0 135.0
OMHULLENDE VAN DE FUNDAMENTELE COMBINATIES Type
b1
h1
b2
h2
MOMENTEN
Ligger:stramien 1 Fundamentele combinatie
137 114
111
BELASTINGGEVALLEN B.G. Omschrijving 1 Permanent 2 Veranderlijk
Belast/onbelast 2:Permanent EN1991 1:Schaakbord EN1991
VELDBELASTINGEN
0
1
2
0.40 0.50 0.30
e.g. -1.00 0.00
Ligger:stramien 1 B.G:1 Permanent
-70
-83
-106
DWARSKRACHTEN
23.9
Ligger:stramien 1 Fundamentele combinatie
148
141
VELDBELASTINGEN Last Ref. 1
Type 1:q-last
111
Ligger:stramien 1 B.G:1 Permanent q1/p/m q2 psi Afstand Lengte -23.900 -23.900 0.000 15.950
Omschrijving
VELDBELASTINGEN
109
Ligger:stramien 1 B.G:2 Veranderlijk
17.5
-135
-140 Fmin:116 Fmax:251
VELDBELASTINGEN Last Ref. 1
Type 1:q-last
Omschrijving
Ligger:stramien 1 B.G:2 Veranderlijk q1/p/m q2 psi Afstand Lengte -17.500 -17.500 0.000 15.950
BELASTINGCOMBINATIES BC 1 2 3 4
Type Fund. Fund. Kar. Perm.
BG 1 1 1 1
Gen. Factor Perm 1.35 Perm 1.20 Perm 1.00 Perm 1.00
BG 2 2 2
Gen. Factor psi0 1.50 Extr 1.50 Extr 1.00
BG Gen. Factor
GUNSTIGE WERKING PERMANENTE BELASTINGEN
BG Gen. Factor
112 277
REACTIES Stp 1 2 3 4
Fmin 115.85 112.37 138.56 33.53
Fmax 251.25 276.64 306.45 108.78
-159 139 306
33.5 109
Ligger:stramien 1 Fundamentele combinatie Mmin Mmax 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Ligger:stramien 1
BC Velden met gunstige werking 1 1-4 2 1-4
Bijlagen V001 - 152 van 248
Bijlagen V001 - 153 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
OMHULLENDE VAN DE KARAKTERISTIEKE COMBINATIES
TOETSING DOORBUIGING Staaf
VERPLAATSINGEN
[mm]
Ligger:stramien 1 Karakteristieke combinatie 1 2
3.67 2.18
2.06
3
0.13
4
Soort Mtg Lengte Overst Zeeg ut o t BC Sit [m] I J [mm] [mm] Vloer ss 2.00 J N 0.0 -13.2 3 2 Eind ss 3 2 Bijk Vloer db 4.65 N N 0.0 -6.7 3 3 Eind db 3 3 Bijk Vloer db 4.65 N N 0.0 -5.2 3 2 Eind db 3 2 Bijk Vloer db 4.65 N N 0.0 -9.5 3 3 Eind db 3 3 Bijk
Ligger:stramien 1 u Toelaatbaar [mm] [mm] *l -13.2 ±16.0 2*0.004 -9.7 ±12.0 2*0.003 -6.7 ±18.6 0.004 -5.0 ±14.0 0.003 -5.2 ±18.6 0.004 -4.0 ±14.0 0.003 -9.5 ±18.6 0.004 -5.0 ±14.0 0.003
-5.2 -6.7 -9.5 -13.2
STAALPROFIELEN - ALGEMENE GEGEVENS Stabiliteit:
Ligger:stramien 1 Geschoord
Classificatie gehele constructie:
MATERIAAL Mat nr. 1 2 3 4 5
Profielnaam
Vloeisp. [N/mm2 ] 235 235 235 235 235
HEA240 HEA260 HEA160 HEA200 HEA360
6 HEA280 Partiële veiligheidsfactoren: Gamma M;0 : 1.00
235
Productie methode Gewalst Gewalst Gewalst Gewalst Gewalst Gewalst
Gamma M;1
1
Plts. aangr. 1.0*h
2
1.0*h
3
1.0*h
4
1.0*h
boven: onder: boven: onder: boven: onder: boven: onder:
Kipsteunafstanden [m] 0 2.000 0 4.650 0 4.650 0 4.650
Sit Kl Plaats Norm Artikel 2 2 1 Einde 2 12 1 Staaf 2 12 1 Einde 2 12 1 Begin
1.00
Ligger:stramien 1 l gaffel [m] 4.00 4.00 4.65 4.65 4.65 4.65 4.65 4.65
TOETSING SPANNINGEN Staaf Mat BC nr. 1 1 2 1 3 1 4 1
1 :
KIPSTABILITEIT Staaf
Min. drsn. klasse 1 1 1 1 1
EN3-1-1 EN3-1-1 EN3-1-1 EN3-1-1
6.2.8 6.3.2 6.2.8 6.2.8
Formule (6.30) (6.54) (6.30) (6.30)
Ligger:stramien 1 Hoogste toetsing Opm. U.C. [N/mm 2 ] 0.637 150 0.696 164 0.785 184 0.785 184
Bijlagen V001 - 154 van 248
Bijlagen V001 - 155 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
LIGGER:stramien 7 OMHULLENDE VAN DE FUNDAMENTELE COMBINATIES GEOMETRIE
Ligger:stramien 7
MOMENTEN
Ligger:stramien 7 Fundamentele combinatie
Velden: 1 t/m 7
202
190
168
150
.924.665 4.665 4.25
4
4
5.083 5.083 5.084 5.084 5.083 5.083 53.000 2:HEA260
Veld 1 2 3 4 5
Vanaf 0.000 0.920 5.585 10.250 14.500
Tot 0.920 5.585 10.250 14.500 18.500
Lengte 0.920 4.665 4.665 4.250 4.000
11 12
42.834 47.917
47.917 53.000
5.083 5.083
Veld 6 7 8 9 10
Vanaf 18.500 22.500 27.583 32.666 37.750
Tot 22.500 27.583 32.666 37.750 42.834
Ligger:stramien 7 Lengte 4.000 5.083 5.083 5.084 5.084
-76
-84
-90
-127
-142
MOMENTEN
Ligger:stramien 7 Fundamentele combinatie
Velden: 8 t/m 12
202
VELDBELASTINGEN
122
33.6
-99
VELDLENGTEN
137
231
203
197
191
Ligger:stramien 7 B.G:1 Permanent
34.3 -122
VELDBELASTINGEN
Ligger:stramien 7 B.G:1 Permanent q1/p/m q2 psi Afstand Lengte -34.300 -34.300 0.000 53.000
Last Ref. Type Omschrijving 1 1:q-last Project......: 130583 - Saturn Duiven Onderdeel....: Dakligger hellingbaan
VELDBELASTINGEN
Type 1:q-last
DWARSKRACHTEN
Omschrijving
Ligger:stramien 7 Fundamentele combinatie
Velden: 1 t/m 7
25
Last Ref. 1
-114
-129
-180
Ligger:stramien 7 B.G:2 Veranderlijk
VELDBELASTINGEN
-125
192
183
172
221
187
73
Ligger:stramien 7 B.G:2 Veranderlijk q1/p/m q2 psi Afstand Lengte -25.000 -25.000 0.000 53.000
GUNSTIGE WERKING PERMANENTE BELASTINGEN
222
Ligger:stramien 7
BC Velden met gunstige werking 1 1-12 2 1-12 Bijlagen V001 - 156 van 248
-164 Fmin:102 Fmax:237
-207 194 429
-186 159 378
-180 151 363
-170 137 342
-211 164 398
195 440
Bijlagen V001 - 157 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
DWARSKRACHTEN
Ligger:stramien 7 Fundamentele combinatie
Velden: 8 t/m 12
VERPLAATSINGEN
[mm]
Ligger:stramien 7 Karakteristieke combinatie
Velden: 8 t/m 12
220
217
227
217
1.45
169
1.46
-8.3
2.89 1.24
0.15
-7.2
-8.6
-9.1 -14.3
-218
-220 Fmin:195 Fmax:440
188 435
192 442
REACTIES Stp 1 2 3 4 5 6 7 8 9 10 11 12
Fmin 102.22 194.32 159.20 151.18 136.74 164.26 195.26 188.22 191.75 182.23 216.51 53.04
-210
-222
Fmax 236.82 429.46 378.25 362.97 342.33 398.26 440.42 434.66 441.95 427.15 474.30 169.37
182 427
-247 217 474
KIPSTABILITEIT
53 169
Staaf
Ligger:stramien 7 Fundamentele combinatie Mmin Mmax 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
OMHULLENDE VAN DE KARAKTERISTIEKE COMBINATIES VERPLAATSINGEN
[mm]
Ligger:stramien 7 Karakteristieke combinatie
1
Plts. aangr. 1.0*h
2
1.0*h
3
1.0*h
4
1.0*h
5
1.0*h
6
1.0*h
7
1.0*h
8
1.0*h
9
1.0*h
10
1.0*h
11
1.0*h
12
1.0*h
Velden: 1 t/m 7
6.0 1.54
-5.5 -9.3
0.89
-4.37
0.75
-3.68
1.76
0.81
Ligger:stramien 7
boven: onder: boven: onder: boven: onder: boven: onder: boven: onder:
l gaffel [m] 1.84 1.84 4.66 4.66 4.66 4.66 4.25 4.25 4.00 4.00
Kipsteunafstanden [m] 0.920 0.920 4.665 4.665 4.665 4.665 4.250 4.250 4.000 4.000
boven: onder: boven: onder: boven: onder: boven: onder: boven: onder:
4.00 4.00 5.08 5.08 5.08 5.08 5.08 5.08 5.08 5.08
4.000 4.000 5.083 5.083 5.083 5.083 5.084 5.084 5.084 5.084
boven: onder: boven: onder:
5.08 5.08 5.08 5.08
5.083 5.083 5.083 5.083
-3.13 -8.9
Bijlagen V001 - 158 van 248
Bijlagen V001 - 159 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
TOETSING SPANNINGEN 2 2 2 2 2
2 10 10 12 14
1 1 1 1 1
Einde Staaf Staaf Staaf Staaf
EN3-1-1 EN3-1-1 EN3-1-1 EN3-1-1 EN3-1-1
6.2.6 6.3.2 6.3.2 6.3.2 6.3.2
(6.17) (6.54) (6.54) (6.54) (6.54)
6 7 8 9 10
2 2 2 2 2
18 20 20 24 24
1 1 1 1 1
Staaf Staaf Staaf Staaf Staaf
EN3-1-1 EN3-1-1 EN3-1-1 EN3-1-1 EN3-1-1
6.3.2 6.3.2 6.3.2 6.3.2 6.3.2
(6.54) (6.54) (6.54) (6.54) (6.54)
0.790 0.996 0.997 1.005 1.002
186 234 234 236 235
EN3-1-1 6.3.2 EN3-1-1 6.3.2
(6.54) (6.54)
1.146 1.136
269 267
2 2 2 2 2
Sit Kl Plaats Norm Artikel
11 2 2 12 2 2 Opmerkingen: [ 4] Controle [ 8] Controle
28 1 Staaf 28 1 Staaf
Formule
Ligger:stramien 7 Hoogste toetsing Opm. U.C. [N/mm 2 ] 0.188 25 8,4 0.921 216 0.927 218 0.718 169 0.651 153
Staaf Mat BC nr. 1 2 2 2 3 2 4 2 5 2
Staaf
Soort Mtg Lengte Overst Zeeg [m] I J [mm] Vloer ss 0.92 J N 0.0 ss Vloer db 4.67 N N 0.0 db Vloer db 4.67 N N 0.0 db Vloer db 4.25 N N 0.0 db Vloer db 4.00 N N 0.0 db
ut o t BC Sit [mm] 6.0 3 3 Eind 3 3 Bijk -9.3 3 3 Eind 3 3 Bijk -5.5 3 2 Eind 3 2 Bijk -4.4 3 3 Eind 3 3 Bijk -3.7 3 2 Eind 3 2 Bijk
6
Vloer
7
Vloer
8
Vloer
9
Vloer
10
Vloer
1 2 3 4 5
11
Vloer
12
Vloer
db db db db db db db db db db db db db db
4.00
N
N
0.0
-3.1
5.08
N
N
0.0
-8.9
5.08
N
N
0.0
-8.3
5.08
N
N
0.0
-8.6
5.08
N
N
0.0
-9.1
5.08
N
N
0.0
-7.2
5.08
N
N
0.0 -14.3
GEOMETRIE
Ligger:stramien A/4'-7
5.400 5.000 5.000 5.000 5.000 25.400 3:HEA160
gedrukte T-rand houdt geen rekening met 2e-orde-wringing. van de gedrukte rand is toegepast (zonder buiging!).
TOETSING DOORBUIGING
LIGGER:stramien A/4'-7
Ligger:stramien 7 u Toelaatbaar [mm] [mm] *l 6.0 ±7.4 2*0.004 3.4 ±5.5 2*0.003 -9.3 ±18.7 0.004 -5.1 ±14.0 0.003 -5.5 ±18.7 0.004 -3.9 ±14.0 0.003 -4.4 ±17.0 0.004 -3.0 ±12.8 0.003 -3.7 ±16.0 0.004 -2.6 ±12.0 0.003
3 3 3 3 3 3 3 3 3 3
3 3 2 2 3 3 2 2 3 3
Eind Bijk Eind Bijk Eind Bijk Eind Bijk Eind Bijk
-3.1 -2.6 -8.9 -5.5 -8.3 -5.7 -8.6 -5.9 -9.1 -6.0
±16.0 ±12.0 ±20.3 ±15.2 ±20.3 ±15.2 ±20.3 ±15.3 ±20.3 ±15.3
0.004 0.003 0.004 0.003 0.004 0.003 0.004 0.003 0.004 0.003
3 3 3 3
2 2 3 3
Eind Bijk Eind Bijk
-7.2 -5.5 -14.3 -7.4
±20.3 ±15.2 ±20.3 ±15.2
0.004 0.003 0.004 0.003
Bijlagen V001 - 160 van 248
VELDLENGTEN Veld 1 2 3 4 5
Vanaf 0.000 5.400 10.400 15.400 20.400
Ligger:stramien A/4'-7 Tot 5.400 10.400 15.400 20.400 25.400
Lengte 5.400 5.000 5.000 5.000 5.000
VELDBELASTINGEN
Ligger:stramien A/4'-7 B.G:1 Permanent
7.5
VELDBELASTINGEN Last Ref. 1
Ligger:stramien A/4'-7 B.G:1 Permanent Omschrijving q1/p/m q2 psi Afstand Lengte -7.500 -7.500 0.000 25.400
Type 1:q-last
VELDBELASTINGEN
Ligger:stramien A/4'-7 B.G:2 Veranderlijk
2.5
VELDBELASTINGEN Last Ref. 1
Type 1:q-last
Ligger:stramien A/4'-7 B.G:2 Veranderlijk Omschrijving q1/p/m q2 psi Afstand Lengte -2.500 -2.500 0.000 25.400
GUNSTIGE WERKING PERMANENTE BELASTINGEN
Ligger:stramien A/4'-7
BC Velden met gunstige werking 1 1-5 2 1-5
Bijlagen V001 - 161 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
OMHULLENDE VAN DE FUNDAMENTELE COMBINATIES
OMHULLENDE VAN DE KARAKTERISTIEKE COMBINATIES
MOMENTEN
VERPLAATSINGEN
Ligger:stramien A/4'-7 Fundamentele combinatie
39.9
[mm]
Ligger:stramien A/4'-7 Karakteristieke combinatie
2.42
35.8
1.51
0.12
29.2
28.2
-4.63
-5.3 -8.3
-14.3
-15.1
-19.2
-13.5
-27.6
-32.4
-18.6
DWARSKRACHTEN
Ligger:stramien A/4'-7 Fundamentele combinatie
KIPSTABILITEIT Staaf
42.8 32.3
-29.1 -36.9 Fmin:14.3 Fmax:29.1
45.2 80
REACTIES Stp 1 2 3 4 5 6
Fmin 14.26 45.22 36.12 37.17 43.12 12.88
-34.3 36.1 67
Fmax 29.15 79.67 66.60 67.85 75.76 26.89
34.8
35.8 26.9
1
Plts. aangr. 1.0*h
2
1.0*h
3
1.0*h
4
1.0*h
5
1.0*h
boven: onder: boven: onder: boven: onder: boven: onder: boven: onder:
l gaffel [m] 5.40 5.40 5.00 5.00 5.00 5.00 5.00 5.00 5.00 5.00
Ligger:stramien A/4'-7 Kipsteunafstanden [m] 0 5.400 0 5.000 0 5.000 0 5.000 0 5.000
-33.1 37.2 68
-40.0 43.1 76
12.9 26.9
Ligger:stramien A/4'-7 Fundamentele combinatie Mmin Mmax 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TOETSING SPANNINGEN Staaf Mat BC nr. 1 3 2 3 3 3 4 3 5 3
2 8 1 Einde 2 8 1 Begin 2 12 1 Einde 2 14 1 Einde 2 14 1 Begin
EN3-1-1 EN3-1-1 EN3-1-1 EN3-1-1 EN3-1-1
Formule
6.2.8 6.2.8 6.2.8 6.2.8 6.2.8
(6.30) (6.30) (6.30) (6.30) (6.30)
Ligger:stramien A/4'-7 Hoogste toetsing Opm. U.C. [N/mm 2 ] 0.692 163 0.692 163 0.507 119 0.621 146 0.621 146
TOETSING DOORBUIGING Staaf 1 2 3
Bijlagen V001 - 162 van 248
Sit Kl Plaats Norm Artikel
Ligger:stramien A/4'-7 Soort Mtg Lengte Overst Zeeg ut o t BC Sit u Toelaatbaar [m] I J [mm] [mm] [mm] [mm] *l Vloer db 5.40 N N 0.0 -18.6 3 2 Eind -18.6 ±21.6 0.004 db 3 2 Bijk -5.7 ±16.2 0.003 Vloer db 5.00 N N 0.0 -4.6 3 3 Eind -4.6 ±20.0 0.004 db 3 2 Bijk 3.8 ±15.0 0.003 Vloer db 5.00 N N 0.0 -8.3 3 2 Eind -8.3 ±20.0 0.004 db 3 2 Bijk -3.7 ±15.0 0.003
4
Vloer
5
Vloer
db db db db
5.00
N
N
0.0
-5.3
5.00
N
N
0.0 -13.5
3 3 3 3
3 2 2 2
Eind Bijk Eind Bijk
-5.3 3.6 -13.5 -4.3
±20.0 ±15.0 ±20.0 ±15.0
0.004 0.003 0.004 0.003
Bijlagen V001 - 163 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
LIGGER:stramien H GUNSTIGE WERKING PERMANENTE BELASTINGEN GEOMETRIE
Ligger:stramien H
Ligger:stramien H
BC Velden met gunstige werking 1 1-10 2 1-10
OMHULLENDE VAN DE FUNDAMENTELE COMBINATIES MOMENTEN
Ligger:stramien H Fundamentele combinatie
Velden: 1 t/m 6 7.000
4
4 5 25.000 4:HEA200
5
5.550 5.45 5 5 3.4 10.000 14.400 3:HEA160
60 43.9
36.5
VELDLENGTEN Veld 1 2 3 4 5
Vanaf 0.000 7.000 11.000 15.000 20.000
Tot 7.000 11.000 15.000 20.000 25.000
Lengte 7.000 4.000 4.000 5.000 5.000
Veld 6 7 8 9 10
Vanaf 25.000 30.550 36.000 41.000 46.000
Tot 30.550 36.000 41.000 46.000 49.400
26.2
Ligger:stramien H Lengte 5.550 5.450 5.000 5.000 3.400
10.9 -4.5 -15.5
-15.7 -27.4
-33.5
-54
DOORSNEDEN sector 1 2 3 sector 1 2 3
Vanaf 0.000 25.000 35.000 Vanaf 0.000 25.000 35.000
Tot 25.000 35.000 49.400 Tot 25.000 35.000 49.400
Lengte Profiel begin z-begin 25.000 4:HEA200 0.000 10.000 3:HEA160 0.000 14.400 3:HEA160 0.000 Lengte Eindcode Bedding Br.[mm] 25.000 0:Scharnier 10.000 0:Scharnier 14.400 1:Vast
VELDBELASTINGEN
Ligger:stramien H Profiel eind z-eind 4:HEA200 0.000 3:HEA160 0.000 3:HEA160 0.000
MOMENTEN
43.9 25.6
Ligger:stramien H B.G:1 Permanent
q1=7.3
-19.3
-18.2
-11.3
q2=7.5
VELDBELASTINGEN Type 1:q-last 1:q-last
31.6
27.9
-17.4
Last Ref. 1 2
Ligger:stramien H Fundamentele combinatie
Velden: 7 t/m 10
Omschrijving q1 q2
VELDBELASTINGEN
Ligger:stramien H B.G:1 Permanent q1/p/m q2 psi Afstand Lengte -7.300 -7.300 0.000 15.000 -7.500 -7.500 15.000 34.400 Ligger:stramien H B.G:2 Veranderlijk
q1=q2=2.5
VELDBELASTINGEN Last Ref. 1
Type 1:q-last
Omschrijving q1=q2
Ligger:stramien H B.G:2 Veranderlijk q1/p/m q2 psi Afstand Lengte -2.500 -2.500 0.000 49.400 Bijlagen V001 - 164 van 248
Bijlagen V001 - 165 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
DWARSKRACHTEN
Ligger:stramien H Fundamentele combinatie
OMHULLENDE VAN DE KARAKTERISTIEKE COMBINATIES
Velden: 1 t/m 6
VERPLAATSINGEN
[mm]
Ligger:stramien H Karakteristieke combinatie
Velden: 1 t/m 6
54 44.3 36.5
32.2
3.14
27.0
0.53
0.12
17.9
-2.07
-2.58 -6.0
-24.5
-29.6
-32.6
-37.4
-40.6 52 95
Fmin:19.5 Fmax:37.4
18.2 42.4
DWARSKRACHTEN
-40.4 44.3 77
34.7 65
31.8 57
48.5 83
Ligger:stramien H Fundamentele combinatie
Velden: 7 t/m 10
-20.0 -23.7
VERPLAATSINGEN
[mm]
Ligger:stramien H Karakteristieke combinatie
Velden: 7 t/m 10 35.7
34.5
33.5
2.11
0.60
0.31
17.2
-2.24 -8.1
-8.2 -33.6
-39.1 Fmin:48.5 Fmax:83
36.9 68
-35.0 38.5 71
REACTIES Stp 1 2 3 4 5 6 7 8 9 10 11
Fmin 19.47 52.46 18.24 34.71 44.34 31.82 48.46 36.86 38.48 34.81 6.35
Fmax 37.44 94.71 42.38 64.81 76.94 56.60 83.36 68.09 70.72 63.36 17.24
-7.6
-29.8 34.8 63
KIPSTABILITEIT
6.4 17.2
Staaf
Ligger:stramien H Fundamentele combinatie Mmin Mmax 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Bijlagen V001 - 166 van 248
1
Plts. aangr. 1.0*h
2
1.0*h
3
1.0*h
4
1.0*h
5
1.0*h
6
1.0*h
7-8
1.0*h
9
1.0*h
10
1.0*h
11
1.0*h
Ligger:stramien H
boven: onder: boven: onder: boven: onder: boven: onder: boven: onder:
l gaffel [m] 7.00 7.00 4.00 4.00 4.00 4.00 5.00 5.00 5.00 5.00
boven: onder: boven: onder: boven: onder: boven: onder: boven: onder:
5.55 5.55 5.45 5.45 5.00 5.00 5.00 5.00 3.40 3.40
Kipsteunafstanden [m] 7.000 7.000 4.000 4.000 4.000 4.000 5.000 5.000 5.000 5.000 5.550 5.550 5.450 5.450 5.000 5.000 5.000 5.000 3.400 3.400
Bijlagen V001 - 167 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
TOETSING SPANNINGEN Staaf Mat BC nr. 1 4 2 4 3 4 4 4 5 4
Sit Kl Plaats Norm Artikel 2 8 1 Staaf 2 8 1 Staaf 2 12 1 Staaf 2 14 1 Staaf 2 14 1 Staaf
6 3 2 18 1 7-8 3 2 18 1 9 3 2 22 1 10 3 2 22 1 11 3 2 24 1 Opmerkingen: [ 60] Waarschuwing:
Staaf Staaf Staaf Staaf Staaf
Formule
EN3-1-1 EN3-1-1 EN3-1-1 EN3-1-1 EN3-1-1
6.3.2 6.3.2 6.3.2 6.3.2 6.3.2
(6.54) (6.54) (6.54) (6.54) (6.54)
EN3-1-1 EN3-1-1 EN3-1-1 EN3-1-1 EN3-1-1
6.3.2 6.3.2 6.3.2 6.3.2 6.3.2
(6.54) (6.54) (6.54) (6.54) (6.54)
Ligger:stramien H Hoogste toetsing Opm. U.C. [N/mm 2 ] 0.792 186 0.622 146 0.270 64 0.407 96 0.405 95
1 2 3 4 5
Soort Mtg Lengte Overst Zeeg ut o t BC Sit [m] I J [mm] [mm] Vloer db 7.00 N N 0.0 -23.7 3 2 Eind db 3 2 Bijk Vloer db 4.00 N N 0.0 3.1 3 2 Eind db 3 2 Bijk Vloer db 4.00 N N 0.0 -2.1 3 2 Eind db 3 2 Bijk Vloer db 5.00 N N 0.0 -2.6 3 3 Eind db 3 2 Bijk Vloer db 5.00 N N 0.0 -6.0 3 2 Eind db 3 2 Bijk
6
Vloer
7-8
Vloer
9
Vloer
10
Vloer
11
Vloer
db db db db db db db db db db
212 209 146 147 109
GEOMETRIE
5.55
N
N
0.0 -20.0
5.45
N
N
0.0
-8.2
5.00
N
N
0.0
-8.1
5.00
N
N
0.0
-7.6
3.40
N
N
0.0
-2.2
3 3 3 3 3 3 3 3 3 3
3 3 2 3 3 2 2 2 3 2
Eind Bijk Eind Bijk Eind Bijk Eind Bijk Eind Bijk
10.000 10.000 5:HEA360
Ligger:stramien H u Toelaatbaar [mm] [mm] *l -23.7 ±28.0 0.004 -6.3 ±21.0 0.003 3.1 ±16.0 0.004 1.2 ±12.0 0.003 -2.1 ±16.0 0.004 -0.9 ±12.0 0.003 -2.6 ±20.0 0.004 1.8 ±15.0 0.003 -6.0 ±20.0 0.004 -1.9 ±15.0 0.003 -20.0 -6.3 -8.2 5.7 -8.1 4.5 -7.6 -3.3 -2.2 1.7
±22.2 ±16.7 ±21.8 ±16.4 ±20.0 ±15.0 ±20.0 ±15.0 ±13.6 ±10.2
Ligger:str. B'/4-5
60
Er is een intern staafscharnier aanwezig!
TOETSING DOORBUIGING Staaf
0.903 0.888 0.622 0.626 0.466
LIGGER:str. B'/4-5
0.004 0.003 0.004 0.003 0.004 0.003 0.004 0.003 0.004 0.003
VELDLENGTEN Veld 1
Vanaf 0.000
Ligger:str. B'/4-5 Tot 10.000
Lengte 10.000
VELDBELASTINGEN
Ligger:str. B'/4-5 B.G:1 Permanent
63 q1=4.5
VELDBELASTINGEN Last Ref. 1 2
Type 1:q-last 8:Puntlast
Omschrijving q1
VELDBELASTINGEN
Ligger:str. B'/4-5 B.G:1 Permanent q1/p/m q2 psi Afstand Lengte -4.500 -4.500 0.000 10.000 -63.000 3.900 Ligger:str. B'/4-5 B.G:2 Veranderlijk
53
VELDBELASTINGEN Last Ref. 1
Type 8:Puntlast
Omschrijving
Ligger:str. B'/4-5 B.G:2 Veranderlijk q1/p/m q2 psi Afstand Lengte -53.000 3.900
GUNSTIGE WERKING PERMANENTE BELASTINGEN
Ligger:str. B'/4-5
BC Velden met gunstige werking 1 1 2 1
Bijlagen V001 - 168 van 248
Bijlagen V001 - 169 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
OMHULLENDE VAN DE FUNDAMENTELE COMBINATIES
OMHULLENDE VAN DE KARAKTERISTIEKE COMBINATIES
MOMENTEN
VERPLAATSINGEN
Ligger:str. B'/4-5 Fundamentele combinatie
[mm]
Ligger:str. B'/4-5 Karakteristieke combinatie
-449
DWARSKRACHTEN
-43.1
Ligger:str. B'/4-5 Fundamentele combinatie
KIPSTABILITEIT Staaf
94
1
Plts. aangr. 1.0*h
l gaffel [m] boven: 10.00 onder: 10.00
Ligger:str. B'/4-5 Kipsteunafstanden [m] 0 10.000
TOETSING SPANNINGEN
Ligger:str. B'/4-5 Staaf Mat BC Sit Kl Plaats Norm Artikel Formule Hoogste toetsing Opm. nr. U.C. [N/mm 2 ] 1 5 2 2 1 My-max EN3-1-1 6.2.8 (6.30) 0.915 215 46 Opmerkingen: [ 46] T.b.v. kip is een equivalente Q-last berekend.
TOETSING DOORBUIGING
-128 Fmin:60 Fmax:128
47.4 94
Staaf 1
REACTIES Stp 1 2
Fmin 59.88 47.41
Fmax 128.34 94.21
Ligger:str. B'/4-5 Fundamentele combinatie Mmin Mmax 0.00 0.00 0.00 0.00
Bijlagen V001 - 170 van 248
Soort Mtg Lengte Overst Zeeg ut o t BC Sit [m] I J [mm] [mm] Vloer db 10.00 N N 20.0 -43.1 3 1 Eind db 3 1 Bijk
Ligger:str. B'/4-5 u Toelaatbaar [mm] [mm] *l -23.1 ±40.0 0.004 -14.9 ±30.0 0.003
Bijlagen V001 - 171 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
LIGGER:str. A-B/4-5
OMHULLENDE VAN DE FUNDAMENTELE COMBINATIES
Profiel : HEA280
MOMENTEN GEOMETRIE
Ligger:str. A-B/4-5 Fundamentele combinatie
Ligger:str. A-B/4-5
6.100 6.100 6
-224
VELDLENGTEN Veld 1
Vanaf 0.000
Ligger:str. A-B/4-5 Tot 6.100
DWARSKRACHTEN
Ligger:str. A-B/4-5 Fundamentele combinatie
Lengte 6.100
147
VELDBELASTINGEN
Ligger:str. A-B/4-5 B.G:1 Permanent
q2=20.9
VELDBELASTINGEN Last Ref. 1
Type 1:q-last
Omschrijving q2
VELDBELASTINGEN
Ligger:str. A-B/4-5 B.G:1 Permanent q1/p/m q2 psi Afstand Lengte -20.900 -20.900 0.000 6.100
Ligger:str. A-B/4-5 B.G:2 Veranderlijk
Last Ref. 1
Type 1:q-last
59 147
REACTIES
q2=14.8
VELDBELASTINGEN
-147 Fmin:59 Fmax:147
Ligger:str. A-B/4-5 B.G:2 Veranderlijk Omschrijving q1/p/m q2 psi Afstand Lengte q2 -14.800 -14.800 0.000 6.100
GUNSTIGE WERKING PERMANENTE BELASTINGEN
Stp 1 2
Fmin 59.47 59.47
Fmax 147.00 147.00
Ligger:str. A-B/4-5 Fundamentele combinatie Mmin Mmax 0.00 0.00 0.00 0.00
Ligger:str. A-B/4-5
BC Velden met gunstige werking 1 1 2 1
Bijlagen V001 - 172 van 248
Bijlagen V001 - 173 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
OMHULLENDE VAN DE KARAKTERISTIEKE COMBINATIES
4
VERPLAATSINGEN
TS/Liggers
[mm]
Ligger:str. A-B/4-5 Karakteristieke combinatie
VLOERLIGGERS (THQ)
Project......: Onderdeel....: Constructeur.: Opdrachtgever: Dimensies....: Datum........: Bestand......:
Rel: 5.27c 19 apr 2013 130583 - Saturn Duiven Vloerligger stramien 2 + 3 (magzijn) ENN kN/m/rad 08/04/2013 m:\bouw\projecten\130583 saturn duiven\4_berekeningen\ vloerligger thq str 2+3.dlw
Betrouwbaarheidsklasse -22.9
Staaf 1
Plts. aangr. 1.0*h
l gaffel [m] boven: 6.10 onder: 6.10
Ligger:str. A-B/4-5 Staal
Kipsteunafstanden [m] 0 6.100
Ligger:str. A-B/4-5 Staaf Mat BC Sit Kl Plaats Norm Artikel Formule Hoogste toetsing Opm. nr. U.C. [N/mm 2 ] 1 6 2 2 1 My-max EN3-1-1 6.2.5 (6.12y) 0.858 202
Staaf 1
Soort Mtg Lengte Overst Zeeg ut o t BC Sit [m] I J [mm] [mm] Vloer db 6.10 N N 20.0 -13.6 3 2 Eind -22.9 3 1 Eind db 3 1 Bijk
: 50
NEN-EN 1990:2002 NEN-EN 1991-1-1:2002 NEN-EN 1993-1-1:2006
C2:2010 C1:2009 C2:2009
NB:2011(nl) NB:2011(nl) NB:2011(nl)
LIGGER:STR.2 (VOL)
TOETSING SPANNINGEN
TOETSING DOORBUIGING
Referentieperiode
Toegepaste normen volgens Eurocode met Nederlandse NB Belastingen
KIPSTABILITEIT
: 2
GEOMETRIE
Ligger:str. A-B/4-5 u Toelaatbaar [mm] [mm] *l 6.4 ±24.4 0.004 -2.9 -9.3 ±18.3 0.003
Ligger:STR.2 (VOL)
3.1 4.5
4.5 3.9 5.150 5.150 8.500 8.500 26.300 17.800 1:STRIP100*327
VELDLENGTEN Veld 1 2 3 4 5
Vanaf 0.000 3.100 7.600 12.100 16.000
Tot 3.100 7.600 12.100 16.000 21.150
Lengte 3.100 4.500 4.500 3.900 5.150
Veld 6 7 8 9
Vanaf 21.150 26.300 34.800 43.300
Tot 26.300 34.800 43.300 44.100
.8
Ligger:STR.2 (VOL) Lengte 5.150 8.500 8.500 0.800
MATERIALEN Mt Omschrijving E-mechanica[N/mm2] Cement 1 S355 210000
Bijlagen V001 - 174 van 248
Kruipcoef. S.M. S.M.verh. Pois. 78.5 0.30
Bijlagen V001 - 175 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
PROFIELEN [mm] Prof. 1 2 3 4
BELASTINGCOMBINATIES
Omschrijving STRIP100*327 STRIP100*394 STRIP100*346 HEB300
Materiaal 1:S355 1:S355 1:S355 1:S355
Oppervlak 3.2700e+004 3.9400e+004 3.4600e+004 1.4910e+004
Traagheid 2.9138e+008 5.0969e+008 3.4518e+008 2.5170e+008
BC 1 2 3 4 5
Type Fund. Fund. Kar. Quas. Perm.
BG 1 1 1 1 1
Gen. Factor Perm 1.35 Perm 1.20 Perm 1.00 Extr 1.00 Perm 1.00
BG 2 2 2 2
Gen. Factor psi0 1.50 Extr 1.50 Extr 1.00 psi2 1.00
BG Gen. Factor
BG Gen. Factor
PROFIELEN vervolg [mm] Prof. Vormf. Breedte Hoogte 1 0.00 100 327 2 0.00 100 394 3 0.00 100 346 4 0.00 300 300
ey 163.5 197.0 173.0 150.0
Type
b1
h1
h2
GUNSTIGE WERKING PERMANENTE BELASTINGEN
Ligger:STR.2 (VOL)
BC Velden met gunstige werking 1 1-9 2 1-9
DOORSNEDEN sector Vanaf Tot 1 0.000 26.300 2 26.300 44.100 sector Vanaf Tot 1 0.000 26.300 2 26.300 44.100
b2
Ligger:STR.2 (VOL) Profiel eind z-eind 1:STRIP100*327 0.000 1:STRIP100*327 0.000
Lengte Profiel begin z-begin 26.300 1:STRIP100*327 0.000 17.800 1:STRIP100*327 0.000 Lengte Eindcode Bedding Br.[mm] 26.300 0:Scharnier 17.800 1:Vast
OMHULLENDE VAN DE FUNDAMENTELE COMBINATIES MOMENTEN
Ligger:STR.2 (VOL) Fundamentele combinatie
Velden: 1 t/m 6
228
188
203
190
158
BELASTINGGEVALLEN B.G. Omschrijving 1 Permanent 2 Veranderlijk
Belast/onbelast 2:Permanent EN1991 1:Schaakbord EN1991
VELDBELASTINGEN
0
1
2
e.g. -1.00 0.00
1.00 0.90 0.80
-94
-138
-141
-147
Ligger:STR.2 (VOL) B.G:1 Permanent
MOMENTEN q1=41.6
-93
-114
q2=22.2
q3=22.2
14.3
Ligger:STR.2 (VOL) Fundamentele combinatie
Velden: 7 t/m 9
488
VELDBELASTINGEN Last Ref. 1 2 3
Type 1:q-last 1:q-last 1:q-last
Omschrijving q1 q2 q3
VELDBELASTINGEN
Ligger:STR.2 (VOL) B.G:1 Permanent q1/p/m q2 psi Afstand Lengte -41.600 -41.600 0.000 16.000 -22.200 -22.200 16.000 10.300 -22.200 -14.300 26.300 17.800
14.2
Ligger:STR.2 (VOL) B.G:2 Veranderlijk -279
q1=37.5
VELDBELASTINGEN Last Ref. 1 2 3
Type 1:q-last 1:q-last 1:q-last
q3=20
14.3
Ligger:STR.2 (VOL) B.G:2 q1/p/m q2 psi -37.500 -37.500 -20.000 -20.000 -20.000 -14.300
Veranderlijk Afstand Lengte 0.000 16.000 16.000 10.300 26.300 17.800
q2=20
Omschrijving q1 q2 q3
Bijlagen V001 - 176 van 248
-362
Bijlagen V001 - 177 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
DWARSKRACHTEN
Ligger:STR.2 (VOL) Fundamentele combinatie
OMHULLENDE VAN DE KARAKTERISTIEKE COMBINATIES
Velden: 1 t/m 6
MOMENTEN 240
281
Ligger:STR.2 (VOL) Karakteristieke combinatie
Velden: 1 t/m 6
274
240 184
-65 -148
Fmin:20.1 Fmax:148
-170 -270 222 510
-284 246 565
DWARSKRACHTEN
-200
160
132
137
-96
133
110
-65
-78
-98
MOMENTEN
-259
142
-103
Ligger:STR.2 (VOL) Karakteristieke combinatie
Velden: 7 t/m 9 225 533
169 410
174 384
154 349
344
Ligger:STR.2 (VOL) Fundamentele combinatie
Velden: 7 t/m 9 10.0
301 164
-194 -254
OMHULLENDE VAN DE QUASI-BLIJVENDE COMBINATIES
-35.7
MOMENTEN
-212 -274 267 575
Fmin:154 Fmax:349
REACTIES Stp 1 2 3 4 5 6 7 8 9
Fmin 20.08 222.42 245.81 224.65 169.50 174.30 153.56 266.53 67.15
Fmax 147.90 510.48 565.17 532.73 409.99 384.25 348.80 575.21 199.55
Ligger:STR.2 (VOL) Quasi-Blijvende combinatie
Velden: 1 t/m 6 67 200
144
118
Ligger:STR.2 (VOL) Fundamentele combinatie Mmin Mmax 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
-57
-85
127
-86
MOMENTEN
121
98
-56
-68
-93
Ligger:STR.2 (VOL) Quasi-Blijvende combinatie
Velden: 7 t/m 9 313
9.1
-173 -228 Bijlagen V001 - 178 van 248
Bijlagen V001 - 179 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
LIGGER:STR.3 (VOL)
OMHULLENDE VAN DE FUNDAMENTELE COMBINATIES
GEOMETRIE
Ligger:STR.3 (VOL)
MOMENTEN
Ligger:STR.3 (VOL) Fundamentele combinatie
865
818
869
847 702
6.500
8.000
8.000 8.000 44.400 3:STRIP100*346
8.000
5.900
VELDLENGTEN Veld 1 2 3 4 5
Vanaf 0.000 6.500 14.500 22.500 30.500
Tot 6.500 14.500 22.500 30.500 38.500
Lengte 6.500 8.000 8.000 8.000 8.000
Veld 6
Vanaf 38.500
Tot 44.400
Vanaf Tot 0.000 44.400 Vanaf Tot 0.000 44.400
Lengte Profiel begin z-begin 44.400 3:STRIP100*346 0.000 Lengte Eindcode Bedding Br.[mm] 44.400 1:Vast
VELDBELASTINGEN
VELDBELASTINGEN Type 1:q-last 1:q-last
Omschrijving q1 q2
VELDBELASTINGEN
VELDBELASTINGEN Type 1:q-last 1:q-last
585
Ligger:STR.3 (VOL) Profiel eind z-eind 3:STRIP100*346 0.000
q2=52
-508
-539
-546
Ligger:STR.3 (VOL) Fundamentele combinatie
604
610
601
553 307
Ligger:STR.3 (VOL) B.G:1 Permanent q1/p/m q2 psi Afstand Lengte -52.000 -52.000 0.000 26.000 -52.000 -45.600 26.000 18.400
Omschrijving q1 q2
q2=45
-383
45.6
Ligger:STR.3 (VOL) B.G:2 Veranderlijk
q1=45
Last Ref. 1 2
-530
Ligger:STR.3 (VOL) B.G:1 Permanent
q1=52
Last Ref. 1 2
-377 -519
DWARSKRACHTEN
DOORSNEDEN sector 1 sector 1
Ligger:STR.3 (VOL) Lengte 5.900
39.3
-604 529 1189
Fmin:81 Fmax:383
-611 526 1214
REACTIES Stp 1 2 3 4 5 6 7
Fmin 80.92 529.33 525.83 524.27 516.59 465.29 50.27
Fmax 382.94 1188.91 1214.21 1216.74 1183.88 1049.46 306.96
-607 524 1217
-583 517 1184
-496 465 1049
50 307
Ligger:STR.3 (VOL) Fundamentele combinatie Mmin Mmax 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Ligger:STR.3 (VOL) B.G:2 Veranderlijk q1/p/m q2 psi Afstand Lengte -45.000 -45.000 0.000 26.000 -45.000 -39.300 26.000 18.400
GUNSTIGE WERKING PERMANENTE BELASTINGEN
Ligger:STR.3 (VOL)
BC Velden met gunstige werking 1 1-6 2 1-6 Bijlagen V001 - 180 van 248
Bijlagen V001 - 181 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
OMHULLENDE VAN DE KARAKTERISTIEKE COMBINATIES
LIGGER:STR.3 (HALF)
MOMENTEN
GEOMETRIE
Ligger:STR.3 (VOL) Karakteristieke combinatie
606
574
608
Ligger:STR.3 (HALF)
594 493
6.500
8.000
8.000 8.000 44.400 3:STRIP100*346
8.000
5.900
VELDLENGTEN -262 -362
-368
-353
-373
-379
OMHULLENDE VAN DE QUASI-BLIJVENDE COMBINATIES MOMENTEN
Veld 1 2 3 4 5
Vanaf 0.000 6.500 14.500 22.500 30.500
Tot 6.500 14.500 22.500 30.500 38.500
Lengte 6.500 8.000 8.000 8.000 8.000
Veld 6
Vanaf 38.500
Tot 44.400
Ligger:STR.3 (HALF) Lengte 5.900
Ligger:STR.3 (VOL) Quasi-Blijvende combinatie
DOORSNEDEN 543
517
545
sector 1 sector 1
533 443
Vanaf Tot 0.000 44.400 Vanaf Tot 0.000 44.400
Lengte Profiel begin z-begin 44.400 3:STRIP100*346 0.000 Lengte Eindcode Bedding Br.[mm] 44.400 1:Vast
VELDBELASTINGEN
Ligger:STR.3 (HALF) Profiel eind z-eind 3:STRIP100*346 0.000
Ligger:STR.3 (HALF) B.G:1 Permanent
q1=52
q2=52
45.6
-231 -322
-324
-332
-328
-312
VELDBELASTINGEN Last Ref. 1 2
Type 1:q-last 1:q-last
Omschrijving q1 q2
VELDBELASTINGEN
Ligger:STR.3 (HALF) B.G:1 Permanent q1/p/m q2 psi Afstand Lengte -52.000 -52.000 0.000 26.000 -52.000 -45.600 26.000 18.400
Ligger:STR.3 (HALF) B.G:2 Veranderlijk
q1=25
VELDBELASTINGEN Last Ref. 1 2
Type 1:q-last 1:q-last
q2=25
Ligger:STR.3 (HALF) B.G:2 Veranderlijk Omschrijving q1/p/m q2 psi Afstand Lengte q1 -25.000 -25.000 0.000 26.000 q2 -25.000 -25.000 26.000 18.400
GUNSTIGE WERKING PERMANENTE BELASTINGEN
Ligger:STR.3 (HALF)
BC Velden met gunstige werking 1 1-6 2 1-6 Bijlagen V001 - 182 van 248
Bijlagen V001 - 183 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
OMHULLENDE VAN DE FUNDAMENTELE COMBINATIES
OMHULLENDE VAN DE KARAKTERISTIEKE COMBINATIES
MOMENTEN
MOMENTEN
Ligger:STR.3 (HALF) Fundamentele combinatie
657
628
658
653
Ligger:STR.3 (HALF) Karakteristieke combinatie
468
467
448
554
464 394
-288 -385
-382
DWARSKRACHTEN 459
-379
-388
-392
Ligger:STR.3 (HALF) Fundamentele combinatie
467
470
467
-203 -269
-272
OMHULLENDE VAN DE QUASI-BLIJVENDE COMBINATIES MOMENTEN
439
-268
-273
-276
Ligger:STR.3 (HALF) Quasi-Blijvende combinatie
244 432
416
432
430 364
-293 -467 521 925
Fmin:98 Fmax:293
-471 518 938
-469 513 939
-460 513 927
-402 456 841
68 244
-184 -250
REACTIES Stp 1 2 3 4 5 6 7
Fmin 98.21 521.35 517.81 512.96 513.41 455.56 67.67
Fmax 292.66 925.24 937.85 939.05 926.66 841.07 243.53
-245
-250
-247
-243
Ligger:STR.3 (HALF) Fundamentele combinatie Mmin Mmax 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Bijlagen V001 - 184 van 248
Bijlagen V001 - 185 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
LIGGER:STR.4-6 (VOL)
VELDBELASTINGEN
Profiel : STRIP100*358
Last Ref. 1
GEOMETRIE
Type 1:q-last
Ligger:STR.4-6 (VOL) B.G:1 Permanent q1/p/m q2 psi Afstand Lengte -59.500 -59.500 0.000 53.000
Omschrijving q1
Ligger:STR.4-6 (VOL)
VELDBELASTINGEN
Ligger:STR.4-6 (VOL) B.G:2 Veranderlijk
q1=50
VELDBELASTINGEN 6.500
8.000
8.000
8.000 8.000 53.000 1:STRIP100*358
VELDLENGTEN Veld 1 2 3 4 5
Vanaf 0.000 6.500 14.500 22.500 30.500
Tot 6.500 14.500 22.500 30.500 38.500
Lengte 6.500 8.000 8.000 8.000 8.000
Veld 6 7
8.000
Last Ref. 1
6.500
Ligger:STR.4-6 (VOL) B.G:2 Veranderlijk Omschrijving q1/p/m q2 psi Afstand Lengte q1 -50.000 -50.000 0.000 53.000
BELASTINGCOMBINATIES
Ligger:STR.4-6 (VOL) Tot Lengte 46.500 8.000 53.000 6.500
Vanaf 38.500 46.500
Type 1:q-last
BC 1 2 3 4 5
Type Fund. Fund. Kar. Quas. Perm.
BG 1 1 1 1 1
Gen. Factor Perm 1.35 Perm 1.20 Perm 1.00 Extr 1.00 Perm 1.00
BG 2 2 2 2
Gen. Factor psi0 1.50 Extr 1.50 Extr 1.00 psi2 1.00
BG Gen. Factor
GUNSTIGE WERKING PERMANENTE BELASTINGEN
BG Gen. Factor
Ligger:STR.4-6 (VOL)
BC Velden met gunstige werking 1 1-7 2 1-7
MATERIALEN Mt Omschrijving E-mechanica[N/mm2] Cement 1 S355 210000
Kruipcoef. S.M. S.M.verh. Pois. 78.5 0.30
OMHULLENDE VAN DE FUNDAMENTELE COMBINATIES
PROFIELEN [mm] Prof. Omschrijving 1 STRIP100*358
Materiaal 1:S355
Oppervlak Traagheid 3.5800e+004 3.8236e+008
MOMENTEN
Ligger:STR.4-6 (VOL) Fundamentele combinatie
Velden: 1 t/m 6
PROFIELEN vervolg [mm] Prof. Vormf. Breedte Hoogte 1 0.00 100 358
ey 179.0
Type
b1
h1
b2
938
924
870
h2
938
924
870
BELASTINGGEVALLEN B.G. Omschrijving 1 Permanent 2 Veranderlijk
VELDBELASTINGEN
Belast/onbelast 2:Permanent EN1991 1:Schaakbord EN1991
0
1
2
0.40 0.70 0.60
e.g. -1.00 0.00
Ligger:STR.4-6 (VOL) B.G:1 Permanent -555
-570
-590
-595
-590
-570
q1=59.5
Bijlagen V001 - 186 van 248
Bijlagen V001 - 187 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
MOMENTEN
Ligger:STR.4-6 (VOL) Fundamentele combinatie
REACTIES Stp 1 2 3 4 5 6 7 8
Velden: 7 t/m 7
870
Fmin 93.11 551.52 547.04 542.92 542.92 547.04 551.52 93.11
Fmax 407.80 1262.77 1292.17 1302.26 1302.26 1292.17 1262.77 407.80
Ligger:STR.4-6 (VOL) Fundamentele combinatie Mmin Mmax 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
OMHULLENDE VAN DE KARAKTERISTIEKE COMBINATIES MOMENTEN
-555
Ligger:STR.4-6 (VOL) Karakteristieke combinatie
Velden: 1 t/m 6
DWARSKRACHTEN
Ligger:STR.4-6 (VOL) Fundamentele combinatie
Velden: 1 t/m 6
621
642
650
652
650
691
683
646
691
683
646
642
-407
-414
-427
-430
-427
-414
-408 Fmin:93 Fmax:408
-642 552 1263
DWARSKRACHTEN
-650 547 1292
-652 543 1302
-650 543 1302
-642 547 1292
MOMENTEN 552 1263
Ligger:STR.4-6 (VOL) Fundamentele combinatie
Ligger:STR.4-6 (VOL) Karakteristieke combinatie
Velden: 7 t/m 7 646
Velden: 7 t/m 7 408
-407
-621 Fmin:552 Fmax:1263
93 408
Bijlagen V001 - 188 van 248
Bijlagen V001 - 189 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
OMHULLENDE VAN DE QUASI-BLIJVENDE COMBINATIES
LIGGER:STR.4-6 (HALF) Profiel : STRIP100*358
MOMENTEN
Ligger:STR.4-6 (VOL) Quasi-Blijvende combinatie
GEOMETRIE
Velden: 1 t/m 6
548
543
520
548
543
Ligger:STR.4-6 (HALF)
520
6.500
-317
MOMENTEN
-315
-322
-325
-322
8.000
8.000
8.000 8.000 53.000 1:STRIP100*358
8.000
6.500
-315
VELDLENGTEN
Ligger:STR.4-6 (VOL) Quasi-Blijvende combinatie
Velden: 7 t/m 7 520
Veld 1 2 3 4 5
Vanaf 0.000 6.500 14.500 22.500 30.500
Tot 6.500 14.500 22.500 30.500 38.500
Lengte 6.500 8.000 8.000 8.000 8.000
Veld 6 7
Vanaf 38.500 46.500
VELDBELASTINGEN
Ligger:STR.4-6 (HALF) Tot Lengte 46.500 8.000 53.000 6.500
Ligger:STR.4-6 (HALF) B.G:1 Permanent
q1=59.5
VELDBELASTINGEN -317
Last Ref. 1
Type 1:q-last
Omschrijving q1
VELDBELASTINGEN
Ligger:STR.4-6 (HALF) B.G:1 Permanent q1/p/m q2 psi Afstand Lengte -59.500 -59.500 0.000 53.000
Ligger:STR.4-6 (HALF) B.G:2 Veranderlijk
q1=25
VELDBELASTINGEN Last Ref. 1
Type 1:q-last
Ligger:STR.4-6 (HALF) B.G:2 Veranderlijk Omschrijving q1/p/m q2 psi Afstand Lengte q1 -25.000 -25.000 0.000 53.000
GUNSTIGE WERKING PERMANENTE BELASTINGEN
Ligger:STR.4-6 (HALF)
BC Velden met gunstige werking 1 1-7 2 1-7
Bijlagen V001 - 190 van 248
Bijlagen V001 - 191 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
OMHULLENDE VAN DE FUNDAMENTELE COMBINATIES
DWARSKRACHTEN
Ligger:STR.4-6 (HALF) Fundamentele combinatie
Velden: 7 t/m 7
MOMENTEN
Ligger:STR.4-6 (HALF) Fundamentele combinatie
Velden: 1 t/m 6
295 668
662
634
668
662
634
-462 Fmin:502 Fmax:933 -387
-385
-395
MOMENTEN
-385
-395
-397
115 295
REACTIES
Ligger:STR.4-6 (HALF) Fundamentele combinatie
Velden: 7 t/m 7 634
Stp 1 2 3 4 5 6 7 8
Fmin 114.78 501.83 497.98 495.75 495.75 497.98 501.83 114.78
Fmax 294.88 932.82 945.36 950.18 950.18 945.36 932.82 294.88
Ligger:STR.4-6 (HALF) Fundamentele combinatie Mmin Mmax 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
OMHULLENDE VAN DE KARAKTERISTIEKE COMBINATIES MOMENTEN
Ligger:STR.4-6 (HALF) Karakteristieke combinatie
Velden: 1 t/m 6 -387
DWARSKRACHTEN
512
508
489
Ligger:STR.4-6 (HALF) Fundamentele combinatie
512
508
489
Velden: 1 t/m 6
462
471
475
476
475
470
-295
-290
-296
-298
-296
-290
-295 Fmin:115 Fmax:295
-470 502 933
-475 498 945
-476 496 950
-475 496 950
-471 498 945
502 933
Bijlagen V001 - 192 van 248
Bijlagen V001 - 193 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
MOMENTEN
Ligger:STR.4-6 (HALF) Karakteristieke combinatie
5
GEVELKOLOMMEN
Velden: 7 t/m 7
TS/Raamwerken 489
Rel: 5.26f 19 apr 2013
Dimensies: kN;m;rad (tenzij anders aangegeven) Datum....: 20/08/2012 Bestand..: m:\bouw\projecten\130583 saturn duiven\4_berekeningen\ gevelkolom dak str. 4-6.rww Rekenmodel.......: 1e-orde-elastisch. Theorie voor de bepaling van de krachtsverdeling: Geometrisch lineair. Fysisch lineair. Gunstige werking van de permanente belasting wordt automatisch verwerkt
-295
Toegepaste normen volgens Eurocode met Nederlandse NB
OMHULLENDE VAN DE QUASI-BLIJVENDE COMBINATIES MOMENTEN
Belastingen
Ligger:STR.4-6 (HALF) Quasi-Blijvende combinatie
Staal
NEN-EN 1990:2002 NEN-EN 1991-1-1:2002 NEN-EN 1993-1-1:2006
C2:2010 C1:2009 C2:2009
NB:2011(nl) NB:2011(nl) NB:2011(nl)
Velden: 1 t/m 6
GEOMETRIE 440
438
425
440
438
425
10,000 2.HEA160
3
5,000
-250
MOMENTEN
-241
-244
-245
-244
1.HEA220
2 -241
Ligger:STR.4-6 (HALF) Quasi-Blijvende combinatie
0,000
Velden: 7 t/m 7
1
NIVEAUS
425
Nr. 1 2 3
Z 0.000 5.000 10.000
X-min 0.000 0.000 0.000
X-max 1.000 1.000 1.000
MATERIALEN Mt Omschrijving E-modulus[N/mm2] 1 S235 210000 -250
S.M. Pois. 78.5 0.30
Uitz. coëff 1.2000e-005
PROFIELEN [mm] Prof. Omschrijving 1 HEA160 2 HEA220
Bijlagen V001 - 194 van 248
Materiaal 1:S235 1:S235
Oppervlak Traagheid Vormf. 3.8800e+003 1.6730e+007 0.00 6.4300e+003 5.4100e+007 0.00
Bijlagen V001 - 195 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
PROFIELEN vervolg [mm] Prof. Staaftype Breedte Hoogte 1 0:Normaal 160 152 2 0:Normaal 220 210
e 76.0 105.0
Type
b1
h1
b2
h2
BELASTINGEN
B.G:2 VB Momentaan
42
KNOPEN Knoop 1 2 3
X 0.000 0.000 0.000
Z 0.000 5.000 10.000 60
STAVEN St. 1 2
ki 1 2
kj 2 3
Profiel 2:HEA220 1:HEA160
Aansl.i NDM NDM
Aansl.j NDM NDM
Lengte Opm. 5.000 5.000
VASTE STEUNPUNTEN Nr. knoop Kode XZR 1=vast 0=vrij 1 1 110 2 2 100 3 3 100
Hoek 0.00 0.00 0.00
KNOOPBELASTINGEN Last Knoop Richting 1 3 Z 2 2 Z
BELASTINGGEVALLEN B.G. 1 2 3 4 5
Omschrijving Permanente belasting VB Momentaan VB restant dak VB restant verd Windbelasting
BELASTINGEN
Type e.g.X e.g.Z 1 0.00 -1.00 2 0.00 0.00 2 0.00 0.00 2 0.00 0.00 0 0.00 0.00
B.G:2 VB Momentaan waarde -42.000 -60.000
BELASTINGEN
B.G:3 VB restant dak
18
B.G:1 Permanente belasting
Eigen gewicht van alle staven is meegenomen in berekening. Richting: 197
174
KNOOPBELASTINGEN Last Knoop Richting 1 3 Z
KNOOPBELASTINGEN Last Knoop Richting 1 3 Z 2 2 Z
B.G:3 VB restant dak waarde -18.000
B.G:1 Permanente belasting waarde -197.000 -174.000 Bijlagen V001 - 196 van 248
Bijlagen V001 - 197 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
BELASTINGEN
B.G:4 VB restant verd
BELASTINGCOMBINATIES BC 1 2 3 4 5 6 7 8 9 10 11 12
91
Type Fund. Fund. Fund. Fund. Fund. Kar. Kar. Kar. Blij. Freq. Freq. Quas.
BG 1 1 1 1 1 1 1 1 1 1 1 1
Gen. Factor Perm 1.20 Perm 1.20 Perm 1.20 Perm 1.35 Perm 0.90 Perm 1.00 Perm 1.00 Perm 1.00 Perm 1.00 Perm 1.00 Perm 1.00 Perm 1.00
BG 2 2 2 2 5 2 2 2
Gen. Factor Extr 1.50 Extr 1.50 Extr 1.50 Extr 1.50 Perm 1.00 Extr 1.00 Extr 1.00 Extr 1.00
2 Extr 2 Extr 2 Extr
1.00 1.00 0.60
BG 3 4 5
Gen. Factor Extr 1.50 Extr 1.50 Perm 1.50
3 Extr 4 Extr 5 Perm
1.00 1.00 1.00
3 Extr 4 Extr
0.70 0.50
BG Gen. Factor
GUNSTIGE WERKING PERMANENTE BELASTINGEN
KNOOPBELASTINGEN Last Knoop Richting 1 2 Z
B.G:4 VB restant verd waarde -91.000
BELASTINGEN
B.G:5 Windbelasting
BC 1 2 3 4 5
Staven met gunstige werking Geen Geen Geen Geen Alle staven de factor:0.90
OMHULLENDE VAN DE FUNDAMENTELE COMBINATIES Fundamentele combinatie
-8.8
3.34
15.7
-8.8
3.34
MOMENTEN
STAAFBELASTINGEN Staaf Type 2 1:QZLokaal 1 1:QZLokaal
q1/p/m -3.34 -3.34
q2 -3.34 -3.34
A 0.000 0.000
B 0.000 0.000
B.G:5 Windbelasting psi0 psi1 psi2
Bijlagen V001 - 198 van 248
Bijlagen V001 - 199 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
DWARSKRACHTEN
Fundamentele combinatie
OMHULLENDE VAN DE KARAKTERISTIEKE [mm]
Karakteristieke combinatie
-1.00
-9.4
15.7
-15.7
-3.22
9.4
VERPLAATSINGEN
COMBINATIES
NORMAALKRACHTEN
Fundamentele combinatie
STAALPROFIELEN - ALGEMENE GEGEVENS -329
Stabiliteit: Classificatie gehele constructie: Doorbuiging en verplaatsing: Aantal bouwlagen: Gebouwtype: Toel. horiz. verplaatsing gehele gebouw: Kleinste gevelhoogte [m]:
Geschoord 1 Overig h/300 0.0
-737
MATERIAAL
-740
Mat Profielnaam nr. 1 HEA160 2 HEA220 Partiële veiligheidsfactoren: Gamma M;0 : 1.00
Vloeisp. [N/mm2 ] 235 235 Gamma M;1
KNIKSTABILITEIT Staaf
REACTIES Kn. 1 2 3
X-min -9.39 -31.31 -9.39
X-max 0.00 0.00 0.00
Z-min 337.54
Z-max 739.56
Fundamentele combinatie M-min M-max
1 2
ls y s [m] 5.000 5.000
Classif. y sterke as Geschoord Geschoord
Productie methode Gewalst Gewalst
lk n i k ; y [m] 5.000 5.000
Extra aanp. y Classif. z [kN] zwakke as 0.0 Geschoord 0.0 Geschoord
Min. drsn. klasse 1 1 :
lk n i k ; z [m] 5.000 5.000
1.00 Extra aanp. z [kN] 0.0 0.0
KIPSTABILITEIT Staaf
Bijlagen V001 - 200 van 248
1
Plts. aangr. 1.0*h
2
1.0*h
boven: onder: boven: onder:
l gaffel [m] 5.00 5.00 5.00 5.00
Kipsteunafstanden [m] 5 5 5.000 5.000
Bijlagen V001 - 201 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
TOETSING SPANNINGEN
6
Staaf Mat BC Sit Kl Plaats Norm Artikel Formule Hoogste toetsing Opm. nr. U.C. [N/mm 2 ] 1 2 2 1 1 Staaf EN3-1-1 6.3.1.1 (6.47z) 0.874 205 47 2 1 4 1 1 Staaf EN3-1-1 6.3.1.1 (6.47z) 0.971 228 47 Opmerkingen: [ 47] Bij verlopende normaalkracht wordt de grootste drukkracht genomen.
TOETSING HORIZONTALE VERPLAATSING Staaf 1 2
BC Sit 8 8
1 1
Lengte [m] 5.000 5.000
ue i n d [mm] -1.0 -3.2
Toelaatbaar [mm] [h/] 16.7 300 16.7 300
HELLINGBAAN
TS/Liggers Constructeur.: Dimensies....: Datum........: Bestand......:
Rel: 5.27c 19 apr 2013 ENN kN/m/rad 05/04/2013 m:\bouw\projecten\130583 saturn duiven\4_berekeningen\ hellingbaan.dlw
Betrouwbaarheidsklasse
: 2
Referentieperiode
: 50
Toegepaste normen volgens Eurocode met Nederlandse NB Belastingen
NEN-EN 1990:2002 NEN-EN 1991-1-1:2002 NEN-EN 1993-1-1:2006
Staal
C2:2010 C1:2009 C2:2009
NB:2011(nl) NB:2011(nl) NB:2011(nl)
LIGGER:stramien 1 GEOMETRIE
4
Ligger:stramien 1
4.65 4.65 4.65 5.333 5.334 5.333 55.000 1:HEA220
5
5
VELDLENGTEN Veld 1 2 3 4 5
Vanaf 0.000 4.000 8.650 13.300 17.950
Tot 4.000 8.650 13.300 17.950 23.283
Lengte 4.000 4.650 4.650 4.650 5.333
11 12
47.450 50.300
50.300 55.000
2.850 4.700
Veld 6 7 8 9 10
Vanaf 23.283 28.617 33.950 38.950 43.950
Tot 28.617 33.950 38.950 43.950 47.450
3.52.85 4.7
Ligger:stramien 1 Lengte 5.334 5.333 5.000 5.000 3.500
MATERIALEN Mt Omschrijving E-mechanica[N/mm2] Cement 1 S235 210000
Kruipcoef. S.M. S.M.verh. Pois. 78.5 0.30
PROFIELEN [mm] Prof. 1 2 3 Bijlagen V001 - 202 van 248
Omschrijving HEA220 HEA320 HEA400
Materiaal 1:S235 1:S235 1:S235
Oppervlak Traagheid 6.4300e+003 5.4100e+007 1.2440e+004 2.2930e+008 1.5900e+004 4.5070e+008 Bijlagen V001 - 203 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
PROFIELEN vervolg [mm] Prof. Vormf. Breedte Hoogte 1 0.00 220 210 2 0.00 300 310 3 0.00 300 390
ey 105.0 155.0 195.0
OMHULLENDE VAN DE FUNDAMENTELE COMBINATIES Type
b1
h1
b2
h2
MOMENTEN
Ligger:stramien 1 Fundamentele combinatie
Velden: 1 t/m 6
BELASTINGGEVALLEN B.G. Omschrijving 1 Permanent 2 Veranderlijk
Belast/onbelast 2:Permanent EN1991 1:Schaakbord EN1991
VELDBELASTINGEN
1
2
0.40 0.50 0.30
79
78
q2=23.8
VELDBELASTINGEN Type 1:q-last 1:q-last 1:q-last
Omschrijving q1 q2 q3
VELDBELASTINGEN
77
31.6
q3=31.6
Ligger:stramien 1 B.G:1 Permanent q1/p/m q2 psi Afstand Lengte -23.800 -23.800 0.000 28.300 -23.800 -31.600 28.300 17.700 -31.600 0.000 46.000 9.000
-42.7
-51
-42.6
-46.7
MOMENTEN
Ligger:stramien 1 Fundamentele combinatie
Velden: 7 t/m 12
105
109
105
93
Ligger:stramien 1 B.G:2 Veranderlijk
q2=7
q1=7
9.3
36.3
q3=9.3 -13.2 -31.2
VELDBELASTINGEN Type 1:q-last 1:q-last 1:q-last
Omschrijving q1 q2 q3
Ligger:stramien 1 B.G:2 q1/p/m q2 psi -7.000 -7.000 -7.000 -9.300 -9.300 0.000
Veranderlijk Afstand Lengte 0.000 28.300 28.300 17.700 46.000 9.000
-56
-64
Type Fund. Fund. Kar. Perm.
BG 1 1 1 1
Gen. Factor Perm 1.35 Perm 1.20 Perm 1.00 Perm 1.00
BG 2 2 2
Gen. Factor psi0 1.50 Extr 1.50 Extr 1.00
BG Gen. Factor
GUNSTIGE WERKING PERMANENTE BELASTINGEN
-24.0
-68
DWARSKRACHTEN
Ligger:stramien 1 Fundamentele combinatie
Velden: 1 t/m 6
BELASTINGCOMBINATIES BC 1 2 3 4
-57
-62
35.8
Last Ref. 1 2 3
105
104
92
e.g. -1.00 0.00
Ligger:stramien 1 B.G:1 Permanent
q1=23.8
Last Ref. 1 2 3
0
99
BG Gen. Factor
96
95
100
112
111
Ligger:stramien 1 -64
BC Velden met gunstige werking 1 1-12 2 1-12
-97 Fmin:30.1 Fmax:64
Bijlagen V001 - 204 van 248
114 196
-97 109 193
-95 106 191
-108 117 209
-111 127 223
128 226
Bijlagen V001 - 205 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
DWARSKRACHTEN
Ligger:stramien 1 Fundamentele combinatie
Velden: 7 t/m 12
VERPLAATSINGEN
[mm]
Ligger:stramien 1 Karakteristieke combinatie
Velden: 7 t/m 12
118
0.82
0.60
0.22
0.48
126
122
-0.40
78
-1.70
54
-3.31
16.2 -6.6
-52
-59
-8.9
-9.3
-115
-116
Fmin:128 Fmax:226
-128 144 250
133 235
REACTIES Stp 1 2 3 4 5 6 7 8 9 10 11 12 13
Fmin 30.14 114.20 109.35 106.45 116.63 126.86 127.87 132.77 143.54 132.28 68.08 58.73 7.81
-110 132 236
68 137
59 106
STAALPROFIELEN - ALGEMENE GEGEVENS
7.8 16.2
Stabiliteit:
Ligger:stramien 1 Fundamentele combinatie Mmin Mmax 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fmax 63.80 195.70 192.52 190.97 208.55 222.65 225.61 234.61 249.58 236.41 136.62 105.86 16.23
OMHULLENDE VAN DE KARAKTERISTIEKE COMBINATIES VERPLAATSINGEN
[mm]
-4.81
0.79
0.26
0.06
-4.41
MATERIAAL Mat Profielnaam nr. 1 HEA220 2 HEA320 3 HEA400 Partiële veiligheidsfactoren: Gamma M;0 : 1.00
0.53
0.21
-4.30
Staaf 1
Plts. aangr. 1.0*h
2
1.0*h
3
1.0*h
4
1.0*h
5
1.0*h
6
1.0*h
7
1.0*h
8
1.0*h
9
1.0*h
10
1.0*h
11
1.0*h
12
1.0*h
-5.1 -7.8 -9.0
Bijlagen V001 - 206 van 248
Vloeisp. [N/mm2 ] 235 235 235
Productie methode Gewalst Gewalst Gewalst
Gamma M;1
KIPSTABILITEIT
Ligger:stramien 1 Karakteristieke combinatie
Velden: 1 t/m 6
Ligger:stramien 1 Geschoord
Classificatie gehele constructie:
Min. drsn. klasse 1 1 1 :
1.00
Ligger:stramien 1
boven: onder: boven: onder: boven: onder: boven: onder: boven: onder:
l gaffel [m] 4.00 4.00 4.65 4.65 4.65 4.65 4.65 4.65 5.33 5.33
Kipsteunafstanden [m] 0 4.000 0 4.650 0 4.650 0 4.650 0 5.333
boven: onder: boven: onder: boven: onder: boven: onder: boven: onder:
5.33 5.33 5.33 5.33 5.00 5.00 5.00 5.00 3.50 3.50
0 5.334 0 5.333 0 5.000 0 5.000 0 3.500
boven: onder: boven: onder:
2.85 2.85 4.70 4.70
0 2.850 0 4.700 Bijlagen V001 - 207 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
LIGGER:stramien 2 TOETSING SPANNINGEN Staaf Mat BC nr. 1 1 2 1 3 1 4 1 5 1
2 8 1 Einde 2 8 1 Begin 2 10 1 Begin 2 14 1 Einde 2 16 1 Einde
EN3-1-1 EN3-1-1 EN3-1-1 EN3-1-1 EN3-1-1
6.2.8 6.2.8 6.2.8 6.2.8 6.2.8
(6.30) (6.30) (6.30) (6.30) (6.30)
6 7 8 9 10
2 2 2 2 2
EN3-1-1 EN3-1-1 EN3-1-1 EN3-1-1 EN3-1-1
6.2.8 6.2.8 6.2.8 6.2.8 6.2.8
(6.30) (6.30) (6.30) (6.30) (6.30)
18 18 22 22 24
1 1 1 1 1
Einde Begin Einde Begin Begin
Formule
0.788 0.788 0.818 0.818 0.700
185 185 192 192 164
46 46 46 46
11 1 2 28 1 Einde EN3-1-1 6.2.8 (6.30) 12 1 2 28 1 Begin EN3-1-1 6.2.8 (6.30) Opmerkingen: [ 46] T.b.v. kip is een equivalente Q-last berekend.
0.272 0.272
64 64
46 46
TOETSING DOORBUIGING
Ligger:stramien 1 u Toelaatbaar [mm] [mm] *l -4.8 ±16.0 0.004 -1.6 ±12.0 0.003 -4.4 ±18.6 0.004 -2.1 ±14.0 0.003 -5.1 ±18.6 0.004 -2.3 ±14.0 0.003 -4.3 ±18.6 0.004 2.7 ±14.0 0.003 -9.0 ±21.3 0.004 -3.7 ±16.0 0.003
Staaf
1 1 1 1 1
Sit Kl Plaats Norm Artikel
Ligger:stramien 1 Hoogste toetsing Opm. U.C. [N/mm 2 ] 0.589 139 0.589 139 0.582 137 0.687 161 0.778 183
Soort Mtg Lengte Overst Zeeg [m] I J [mm] Vloer db 4.00 N N 0.0 db Vloer db 4.65 N N 0.0 db Vloer db 4.65 N N 0.0 db Vloer db 4.65 N N 0.0 db Vloer db 5.33 N N 0.0 db
ut o t BC Sit [mm] -4.8 3 2 Eind 3 2 Bijk -4.4 3 3 Eind 3 3 Bijk -5.1 3 2 Eind 3 2 Bijk -4.3 3 3 Eind 3 2 Bijk -9.0 3 2 Eind 3 2 Bijk
6
Vloer
7
Vloer
1 2 3 4 5
8
Vloer
9
Vloer
10
Vloer
11
Vloer
12
Vloer
db db db db db db db db db db
5.33
N
N
0.0
-7.8
5.33
N
N
0.0
-9.3
5.00
N
N
0.0
-6.6
5.00
N
N
0.0
-8.9
3.50
N
N
0.0
-1.7
db
2.85
N
N
0.0
0.5 -0.4
db db db
4.70
N
N
0.0
-3.3
3 3 3 3 3 3 3 3 3 3
3 3 2 2 3 3 2 2 3 2
Eind Bijk Eind Bijk Eind Bijk Eind Bijk Eind Bijk
-7.8 -3.8 -9.3 -4.0 -6.6 -3.3 -8.9 -3.2 -1.7 1.5
±21.3 ±16.0 ±21.3 ±16.0 ±20.0 ±15.0 ±20.0 ±15.0 ±14.0 ±10.5
0.004 0.003 0.004 0.003 0.004 0.003 0.004 0.003 0.004 0.003
3 3 3 3 3
3 2 2 3 3
Eind Eind Bijk Eind Bijk
0.5 -0.4 -0.5 -3.3 -1.0
±11.4
0.004
±8.6 ±18.8 ±14.1
0.003 0.004 0.003
Bijlagen V001 - 208 van 248
GEOMETRIE
Ligger:stramien 2
2 3.1
11.400
8.000 3.8 8.500 46.100 2:HEA320
8.500 6.500 10.000 15.700 3:HEA400
Tot 2.000 5.100 16.500 24.500 28.300
Lengte 2.000 3.100 11.400 8.000 3.800
Vanaf 28.300 36.800 45.300 51.800
VELDLENGTEN Veld 1 2 3 4 5
Vanaf 0.000 2.000 5.100 16.500 24.500
Veld 6 7 8 9
Tot 36.800 45.300 51.800 61.800
DOORSNEDEN sector Vanaf Tot 1 0.000 46.100 2 46.100 61.800 sector Vanaf Tot 1 0.000 46.100 2 46.100 61.800
Lengte Profiel begin z-begin 46.100 2:HEA320 0.000 15.700 3:HEA400 0.000 Lengte Eindcode Bedding Br.[mm] 46.100 0:Scharnier 15.700 1:Vast
VELDBELASTINGEN
Ligger:stramien 2 Lengte 8.500 8.500 6.500 10.000
Ligger:stramien 2 Profiel eind z-eind 2:HEA320 0.000 3:HEA400 0.000
Ligger:stramien 2 B.G:1 Permanent
F1=143 q1=23.8
VELDBELASTINGEN Last Ref. 1 2 3 4
Type 1:q-last 1:q-last 1:q-last 8:Puntlast
Omschrijving q1 q2 q3 F1
q2=23.8
31.6
q3=30.6
Ligger:stramien 2 B.G:1 Permanent q1/p/m q2 psi Afstand Lengte -23.800 -23.800 0.000 28.300 -23.800 -31.600 28.300 17.800 -30.600 -30.600 46.100 15.700 -143.000 46.100
Bijlagen V001 - 209 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
VELDBELASTINGEN
Ligger:stramien 2 B.G:2 Veranderlijk
DWARSKRACHTEN
Ligger:stramien 2 Fundamentele combinatie
Velden: 1 t/m 6 F1=43 q2=7
q1=7
9.3
233
q3=9
164
210 136
80
VELDBELASTINGEN Last Ref. 1 2 3 4
Type 1:q-last 1:q-last 1:q-last 8:Puntlast
Ligger:stramien 2 B.G:2 Omschrijving q1/p/m q2 psi q1 -7.000 -7.000 q2 -7.000 -9.300 q3 -9.000 -9.000 F1 -43.000
GUNSTIGE WERKING PERMANENTE BELASTINGEN
Veranderlijk Afstand Lengte 0.000 28.300 28.300 17.800 46.100 15.700 46.100
121
-11.2 -81 -173
-202
-230 Fmin:10.3211 Fmax:86 395
256 435
76 218
132 294
246 435
Ligger:stramien 2
BC Velden met gunstige werking 1 1-9 2 1-9
DWARSKRACHTEN
Ligger:stramien 2 Fundamentele combinatie
Velden: 7 t/m 9
OMHULLENDE VAN DE FUNDAMENTELE COMBINATIES MOMENTEN
235
214
Ligger:stramien 2 Fundamentele combinatie
213
Velden: 1 t/m 6 397
375
337 199 119
80
-225 -308
-7.4 -123
-175
-286
-359 311 574
Fmin:246 Fmax:435
REACTIES MOMENTEN
Ligger:stramien 2 Fundamentele combinatie
Velden: 7 t/m 9
499 337
271
Stp 1 2 3 4 5 6 7 8 9
Fmin 10.30 210.99 255.85 75.69 132.00 245.75 311.28 316.63 112.95
Fmax 86.50 394.58 434.60 217.74 294.23 434.88 573.90 543.38 213.43
317 543
113 213
Ligger:stramien 2 Fundamentele combinatie Mmin Mmax 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
-64 -214 -440
Bijlagen V001 - 210 van 248
Bijlagen V001 - 211 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
OMHULLENDE VAN DE KARAKTERISTIEKE COMBINATIES TOETSING SPANNINGEN VERPLAATSINGEN
[mm]
Ligger:stramien 2 Karakteristieke combinatie
Velden: 1 t/m 6
3.96
3.86
2.73
0.69
-7.7
-9.0
-15.7
-46.9
VERPLAATSINGEN
[mm]
Ligger:stramien 2 Karakteristieke combinatie
Velden: 7 t/m 9
Staaf Mat BC nr. 1 2 2 2 3 2 4 2 5 2
2
-2.62
3 4
-19.3
5 -32.7
KIPSTABILITEIT Staaf 1
Plts. aangr. 1.0*h
2
1.0*h
3
1.0*h
4
1.0*h
5
1.0*h
6
1.0*h
7
1.0*h
8-9
1.0*h
10
1.0*h
Ligger:stramien 2
boven: onder: boven: onder: boven: onder: boven: onder: boven: onder:
l gaffel [m] 4.00 4.00 3.10 3.10 11.40 11.40 8.00 8.00 3.80 3.80
boven: onder: boven: onder: boven: onder: boven: onder:
8.50 8.50 8.50 8.50 6.50 6.50 10.00 10.00
Kipsteunafstanden [m] 2.000 2.000 3.100 3.100 11.400 11.400 8.000 8.000 3.800 3.800
2 10 12 12 16
1 1 1 1 1
Einde Einde Staaf Staaf Einde
EN3-1-1 EN3-1-1 EN3-1-1 EN3-1-1 EN3-1-1
6.2.8 6.2.8 6.3.2 6.3.2 6.2.8
(6.30) (6.30) (6.54) (6.54) (6.30)
Ligger:stramien 2 Hoogste toetsing Opm. U.C. [N/mm 2 ] 0.210 49 0.981 230 1.435 337 1.180 277 0.519 122
TOETSING DOORBUIGING 1
4.96
2 2 2 2 2
Formule
6 2 2 18 1 Staaf EN3-1-1 6.3.2 (6.54) 1.040 244 7 2 2 18 1 Staaf EN3-1-1 6.3.2 (6.54) 1.034 243 8-9 2 2 22 1 Staaf EN3-1-1 6.3.2 (6.54) 1.514 356 10 3 2 22 1 Staaf EN3-1-1 6.3.2 (6.54) 1.140 268 Opmerkingen: [ 43] Bij een samengestelde staaf is het profiel met de kleinste W genomen voor stabiliteitstoetsingen. [ 46] T.b.v. kip is een equivalente Q-last berekend. [ 60] Waarschuwing: Er is een intern staafscharnier aanwezig!
Staaf
0.59
Sit Kl Plaats Norm Artikel
Soort Mtg Lengte Overst Zeeg ut o t BC Sit [m] I J [mm] [mm] Vloer ss 2.00 J N 0.0 -9.0 3 2 Eind ss 3 2 Bijk Vloer db 3.10 N N 0.0 3.9 3 2 Eind db 3 2 Bijk Vloer db 11.40 N N 0.0 -46.9 3 2 Eind db 3 2 Bijk Vloer db 8.00 N N 0.0 -7.7 3 3 Eind db 3 2 Bijk Vloer db 3.80 N N 0.0 2.7 3 3 Eind db 3 3 Bijk
6
Vloer
7
Vloer
8-9
Vloer
10
Vloer
db db db db db db db db
8.50
N
N
0.0 -15.7
8.50
N
N
0.0 -19.3
6.50
N
N
0.0
10.00
N
N
0.0 -32.7
5.0 -2.6
3 3 3 3 3 3 3 3 3
3 3 5 5 5 3 3 5 5
Eind Bijk Eind Bijk Eind Eind Bijk Eind Bijk
46 46 60,43,46
Ligger:stramien 2 u Toelaatbaar [mm] [mm] *l -9.0 ±16.0 2*0.004 -2.4 ±12.0 2*0.003 3.9 ±12.4 0.004 1.0 ±9.3 0.003 -46.9 ±45.6 0.004 -12.1 ±34.2 0.003 -7.7 ±32.0 0.004 7.9 ±24.0 0.003 2.7 ±15.2 0.004 1.2 ±11.4 0.003 -15.7 -6.0 -19.3 -9.0 5.0 -2.6 -5.1 -32.7 -8.3
±34.0 ±25.5 ±34.0 ±25.5 ±26.0
0.004 0.003 0.004 0.003 0.004
±19.5 ±40.0 ±30.0
0.003 0.004 0.003
8.500 8.500 8.500 8.500 6.500 6.500 10.000 10.000 Bijlagen V001 - 212 van 248
Bijlagen V001 - 213 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
LIGGER:str. 1-2
OMHULLENDE VAN DE FUNDAMENTELE COMBINATIES
Profiel : HEA320
MOMENTEN GEOMETRIE
Ligger:str. 1-2 Fundamentele combinatie
Ligger:str. 1-2 267
-37.0 6.400 6.400 12.800 2:HEA320
-291
VELDLENGTEN Veld 1 2
Vanaf 0.000 6.400
Ligger:str. 1-2 Tot 6.400 12.800
Lengte 6.400 6.400
VELDBELASTINGEN
DWARSKRACHTEN
Ligger:str. 1-2 Fundamentele combinatie
237 154
Ligger:str. 1-2 B.G:1 Permanent
30.6
-24.5
31.6
VELDBELASTINGEN Last Ref. 1 2
Type 1:q-last 1:q-last
Omschrijving q1 q2
Ligger:str. 1-2 B.G:1 Permanent q1/p/m q2 psi Afstand Lengte 0.000 -31.600 0.000 12.800 0.000 -30.600 0.000 12.800
-263 245 418
Fmin:1.5 Fmax:24.5
REACTIES VELDBELASTINGEN
Ligger:str. 1-2 B.G:2 Veranderlijk
9
Stp 1 2 3
Fmin 1.52 245.01 126.07
Fmax 24.48 417.73 237.14
126 237
Ligger:str. 1-2 Fundamentele combinatie Mmin Mmax 0.00 0.00 0.00 0.00 0.00 0.00
9.3
VELDBELASTINGEN Last Ref. 1 2
Type 1:q-last 1:q-last
Omschrijving q1 q2
Ligger:str. 1-2 B.G:2 Veranderlijk q1/p/m q2 psi Afstand Lengte 0.000 -9.300 0.000 12.800 0.000 -9.000 0.000 12.800
GUNSTIGE WERKING PERMANENTE BELASTINGEN
Ligger:str. 1-2
BC Velden met gunstige werking 1 1,2 2 1,2 Bijlagen V001 - 214 van 248
Bijlagen V001 - 215 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
OMHULLENDE VAN DE KARAKTERISTIEKE COMBINATIES
LIGGER:stramien A Profiel : HEA220
VERPLAATSINGEN
[mm]
Ligger:str. 1-2 Karakteristieke combinatie
GEOMETRIE
Ligger:stramien A
3.75
-0.68
4.9 5.05 5.05 5 28.900 1:HEA220
5
3.9
-17.5
VELDLENGTEN
KIPSTABILITEIT Staaf 1
Plts. aangr. 1.0*h
2
1.0*h
boven: onder: boven: onder:
Ligger:str. 1-2 l gaffel [m] 6.40 6.40 6.40 6.40
Kipsteunafstanden [m] 0 6.400 0 6.400
Ligger:str. 1-2 Staaf Mat BC Sit Kl Plaats Norm Artikel Formule Hoogste toetsing Opm. nr. U.C. [N/mm 2 ] 1 2 2 2 1 Staaf EN3-1-1 6.3.2 (6.54) 0.716 168 46 2 2 2 6 1 My-max EN3-1-1 6.2.5 (6.12y) 0.761 179 46 Opmerkingen: [ 46] T.b.v. kip is een equivalente Q-last berekend.
Staaf 1 2
Soort Mtg Lengte Overst Zeeg ut o t BC Sit [m] I J [mm] [mm] Vloer db 6.40 N N 0.0 3.7 3 3 Eind db 3 3 Bijk Vloer db 6.40 N N 0.0 -17.5 3 3 Eind db 3 3 Bijk
Vanaf 0.000 4.900 9.950 15.000 20.000
Tot 4.900 9.950 15.000 20.000 25.000
Lengte 4.900 5.050 5.050 5.000 5.000
Veld 6
VELDBELASTINGEN
TOETSING SPANNINGEN
TOETSING DOORBUIGING
Veld 1 2 3 4 5
Ligger:str. 1-2 u Toelaatbaar [mm] [mm] *l 3.7 ±25.6 0.004 1.8 ±19.2 0.003 -17.5 ±25.6 0.004 -4.4 ±19.2 0.003
30.6
Type 1:q-last 1:q-last
Omschrijving q1 q2
Type 1:q-last 1:q-last
Ligger:stramien A B.G:1 Permanent q1/p/m q2 psi Afstand Lengte 0.000 -30.600 0.000 9.000 -30.600 -30.600 9.000 19.900 Ligger:stramien A B.G:2 Veranderlijk
q2=9
VELDBELASTINGEN Last Ref. 1 2
Ligger:stramien A Lengte 3.900
q2=30.6
VELDBELASTINGEN
9
Tot 28.900
Ligger:stramien A B.G:1 Permanent
VELDBELASTINGEN Last Ref. 1 2
Vanaf 25.000
Omschrijving q1 q2
Ligger:stramien A B.G:2 Veranderlijk q1/p/m q2 psi Afstand Lengte 0.000 -9.000 0.000 9.000 -9.000 -9.000 9.000 19.900
GUNSTIGE WERKING PERMANENTE BELASTINGEN
Ligger:stramien A
BC Velden met gunstige werking 1 1-6 2 1-6
Bijlagen V001 - 216 van 248
Bijlagen V001 - 217 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
OMHULLENDE VAN DE FUNDAMENTELE COMBINATIES
OMHULLENDE VAN DE KARAKTERISTIEKE COMBINATIES
MOMENTEN
VERPLAATSINGEN
Ligger:stramien A Fundamentele combinatie
116
114
115
[mm]
Ligger:stramien A Karakteristieke combinatie
1.21
107
0.39
0.31
0.30
0.26
66 -2.41 -5.2 -20.0 -59
-65
-68
DWARSKRACHTEN
-7.8
-60
-66
-8.6
Ligger:stramien A Fundamentele combinatie
133
133
131 78
60
-14.3
1
Plts. aangr. 1.0*h
2
1.0*h
3
1.0*h
4
1.0*h
5
1.0*h
6
1.0*h
-90 Fmin:3.4 Fmax:14.3
83 150
-133 150 261
-133 152 266
-132 152 265
-127 149 257
35.1 78
Ligger:stramien A
boven: onder: boven: onder: boven: onder: boven: onder: boven: onder:
l gaffel [m] 4.90 4.90 5.05 5.05 5.05 5.05 5.00 5.00 5.00 5.00
boven: onder:
Kipsteunafstanden [m] 0 4.900 0 5.050 0 5.050 0 5.000 0 5.000
3.90 0 3.90 3.900
TOETSING SPANNINGEN REACTIES Stp 1 2 3 4 5 6 7
Fmin 3.38 83.18 150.20 151.71 151.69 148.88 35.06
Fmax 14.27 149.64 260.85 266.12 265.03 257.47 78.23
Ligger:stramien A Fundamentele combinatie Mmin Mmax 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Bijlagen V001 - 218 van 248
-8.2
KIPSTABILITEIT Staaf
127
-8.0
Staaf Mat BC nr. 1 1 2 1 3 1 4 1 5 1
Sit Kl Plaats Norm Artikel 2 2 2 2 2
8 10 12 12 14
1 1 1 1 1
Staaf Einde Einde Begin Begin
EN3-1-1 EN3-1-1 EN3-1-1 EN3-1-1 EN3-1-1
6.3.2 6.2.8 6.2.8 6.2.8 6.2.8
Formule (6.54) (6.30) (6.30) (6.30) (6.30)
Ligger:stramien A Hoogste toetsing Opm. U.C. [N/mm 2 ] 0.529 124 46 0.851 200 46 0.868 204 0.868 204 0.861 202
6 1 2 16 1 Begin EN3-1-1 6.2.8 (6.30) Opmerkingen: [ 46] T.b.v. kip is een equivalente Q-last berekend.
0.801
188
Bijlagen V001 - 219 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
TOETSING DOORBUIGING Staaf 1 2 3 4 5
6
Soort Mtg Lengte Overst Zeeg [m] I J [mm] Vloer db 4.90 N N 0.0 db Vloer db 5.05 N N 0.0 db Vloer db 5.05 N N 0.0 db Vloer db 5.00 N N 0.0 db Vloer db 5.00 N N 0.0 db
ut o t BC Sit [mm] -2.4 3 2 Eind 3 3 Bijk -7.8 3 3 Eind 3 3 Bijk -8.6 3 2 Eind 3 2 Bijk -8.0 3 3 Eind 3 3 Bijk -8.2 3 2 Eind 3 2 Bijk
Vloer
-5.2
db db
3.90
N
N
0.0
3 3
3 Eind 3 Bijk
Ligger:stramien A u Toelaatbaar [mm] [mm] *l -2.4 ±19.6 0.004 2.2 ±14.7 0.003 -7.8 ±20.2 0.004 -3.1 ±15.2 0.003 -8.6 ±20.2 0.004 -3.7 ±15.2 0.003 -8.0 ±20.0 0.004 -3.7 ±15.0 0.003 -8.2 ±20.0 0.004 -3.4 ±15.0 0.003 -5.2 -2.0
±15.6 ±11.7
LIGGER:stramien 5 Profiel : HEA400
GEOMETRIE
Ligger:stramien 5
5.900 3.1 9.000 3:HEA400
0.004 0.003
VELDLENGTEN Veld 1 2
Vanaf 0.000 5.900
Ligger:stramien 5 Tot 5.900 9.000
Lengte 5.900 3.100
VELDBELASTINGEN
Ligger:stramien 5 B.G:1 Permanent
68
VELDBELASTINGEN Last Ref. 1
Type 1:q-last
Omschrijving
VELDBELASTINGEN
Ligger:stramien 5 B.G:1 Permanent q1/p/m q2 psi Afstand Lengte -68.000 -68.000 0.000 9.000 Ligger:stramien 5 B.G:2 Veranderlijk
20
VELDBELASTINGEN Last Ref. 1
Type 1:q-last
Omschrijving
Ligger:stramien 5 B.G:2 Veranderlijk q1/p/m q2 psi Afstand Lengte -20.000 -20.000 0.000 9.000
GUNSTIGE WERKING PERMANENTE BELASTINGEN
Ligger:stramien 5
BC Velden met gunstige werking 1 1,2 2 1,2
Bijlagen V001 - 220 van 248
Bijlagen V001 - 221 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
OMHULLENDE VAN DE FUNDAMENTELE COMBINATIES
OMHULLENDE VAN DE KARAKTERISTIEKE COMBINATIES
MOMENTEN
VERPLAATSINGEN
Ligger:stramien 5 Fundamentele combinatie
[mm]
Ligger:stramien 5 Karakteristieke combinatie
369
1.01
-31.0
-330
DWARSKRACHTEN
-8.5
Ligger:stramien 5 Fundamentele combinatie
KIPSTABILITEIT Staaf
396
1
Plts. aangr. 1.0*h
2
1.0*h
boven: onder: boven: onder:
Ligger:stramien 5 l gaffel [m] 5.90 5.90 3.10 3.10
Kipsteunafstanden [m] 5.900 5.900 3.100 3.100
84
TOETSING SPANNINGEN
Ligger:stramien 5 Staaf Mat BC Sit Kl Plaats Norm Artikel Formule Hoogste toetsing Opm. nr. U.C. [N/mm 2 ] 1 3 2 2 1 Staaf EN3-1-1 6.3.2 (6.54) 0.696 163 2 3 2 2 1 Begin EN3-1-1 6.2.8 (6.30) 0.614 144 -273
-294 402 691
Fmin:147 Fmax:273
REACTIES Stp 1 2 3
Fmin 147.25 401.67 3.33
Fmax 273.13 690.71 83.74
3.3 84
Ligger:stramien 5 Fundamentele combinatie Mmin Mmax 0.00 0.00 0.00 0.00 0.00 0.00
Bijlagen V001 - 222 van 248
TOETSING DOORBUIGING Staaf 1 2
Soort Mtg Lengte Overst Zeeg [m] I J [mm] Vloer db 5.90 N N 0.0 db Vloer db 3.10 N N 0.0 db
ut o t BC Sit [mm] -8.5 3 2 Eind 3 2 Bijk 1.0 3 2 Eind 3 2 Bijk
Ligger:stramien 5 u Toelaatbaar [mm] [mm] *l -8.5 ±23.6 0.004 -2.0 ±17.7 0.003 1.0 ±12.4 0.004 0.4 ±9.3 0.003
Bijlagen V001 - 223 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
7
MATERIALEN
FUNDERINGSBALKEN
TS/Liggers
Rel: 5.27c 19 apr 2013
: 2 Referentieperiode : 15% Toevallige inklemming eind : nee Maximale deellengte : 28 Relatieve vochtigheid gecorrigeerde stijfheden berekend.
: : : :
Prof. Omschrijving 1 B*H 650*500 50 15% 0.000 50%
Fysisch lineair : Er is gerekend met de e-modulus uit de materiaaltabel. Fys.NLE.kort : Er is gerekend met een gecorrigeerde e-modulus (korte duur). Deze e-mod. is berekend mbv de krachten uit de fysisch lineair berekening.
Toegepaste normen volgens Eurocode met Nederlandse NB Belastingen
NEN-EN 1990:2002 NEN-EN 1991-1-1:2002 NEN-EN 1992-1-1:2005
Beton
C2:2010 C1:2009 C2:2010
NB:2011(nl) NB:2011(nl) NB:2011(nl)
LIGGER:stramien 1 Profiel : B*H 650*500
GEOMETRIE
Kruipcoef. S.M. S.M.verh. Pois. 2.77 24.0 0.20
PROFIELEN [mm]
Dimensies....: kN/m/rad Datum........: 05/04/2013 Bestand......: m:\bouw\projecten\130583 saturn duiven\4_berekeningen\ funderingsbalken.dlw Betrouwbaarheidsklasse Toevallige inklemmingen begin Herverdelen van momenten Ouderdom bij belasten Doorbuigingen(beton) zijn dmv
Mt Omschrijving E-mechanica[N/mm2] Cement 1 C25/30 8352 N
Materiaal 1:C25/30
Oppervlak Traagheid 3.2500e+005 6.7708e+009
PROFIELEN vervolg [mm] Prof. Vormf. Breedte Hoogte 1 0.00 650 500
ey 250.0
Type 0:RH
b1
VEREN Veer Steunpunt Richting Veerwaarde 1 1 2:Translatie 2.0000e+004 2 2 2:Translatie 2.0000e+004 3 3 2:Translatie 2.0000e+004 4 4 2:Translatie 2.0000e+004 5 5 2:Translatie 2.0000e+004 6 7 8 9 10
6 7 8 9 10
2:Translatie 2:Translatie 2:Translatie 2:Translatie 2:Translatie
2.0000e+004 2.0000e+004 2.0000e+004 2.0000e+004 2.0000e+004
11 12
11 2:Translatie 2.0000e+004 12 2:Translatie 2.0000e+004
h1
b2
h2
Ondergrens 0.0000e+000 0.0000e+000 0.0000e+000 0.0000e+000 0.0000e+000
Ligger:stramien 1 Bovengrens 0.0000e+000 0.0000e+000 0.0000e+000 0.0000e+000 0.0000e+000
0.0000e+000 0.0000e+000 0.0000e+000 0.0000e+000 0.0000e+000
0.0000e+000 0.0000e+000 0.0000e+000 0.0000e+000 0.0000e+000
0.0000e+000 0.0000e+000 0.0000e+000 0.0000e+000
Ligger:stramien 1
BELASTINGGEVALLEN B.G. 1 2 3 4 5
ref.
4
4.65 4.65 4.65 5.333 5.333 5.334 55.000 1:B*H 650*500
5
5
VELDLENGTEN Veld 1 2 3 4 5
Vanaf 0.000 4.000 8.650 13.300 17.950
Tot 4.000 8.650 13.300 17.950 23.283
Lengte 4.000 4.650 4.650 4.650 5.333
11 12
47.450 52.500
52.500 55.000
5.050 2.500
Veld 6 7 8 9 10
Vanaf 23.283 28.616 33.950 38.950 43.950
Tot 28.616 33.950 38.950 43.950 47.450
Omschrijving Permanent VB momentaan VB extreem wind links wind rechts
Belast/onbelast 2:Permanent EN1991 1:Schaakbord EN1991 1:Schaakbord EN1991 0:Alles tegelijk 0:Alles tegelijk
0
1
0.40 0.40 0.00 0.00
0.70 0.70 0.20 0.20
2 0.60 0.60 0.00 0.00
e.g. -1.00 0.00 0.00 0.00 0.00
3.5 5.050 2.5
Ligger:stramien 1 Lengte 5.333 5.334 5.000 5.000 3.500
Bijlagen V001 - 224 van 248
Bijlagen V001 - 225 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
VELDBELASTINGEN
Ligger:stramien 1 B.G:1 Permanent
VELDBELASTINGEN
F12=42F13=13 F11=62 F5=112 F6=86 F7=89 F8=93 F9=96 F10=92 F1=13F2=150F3=165F4=170q2=8.8 11.6 q3=9.3
F4=370F5=321 F6=283 F7=292 F8=300F9=323F10=305 F12=139 F13=42 F11=163 F2=394F3=358 F1=38 q1=2.3 11.7 q2=19.2 17.7 q3=15.5
VELDBELASTINGEN Last Ref. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Type 1:q-last 1:q-last 1:q-last 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast
Omschrijving q1 q2 q3 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 F13
Ligger:stramien 1 B.G:1 Permanent q1/p/m q2 psi Afstand Lengte -2.300 -11.700 0.000 17.900 -19.200 -17.700 17.900 32.400 -15.500 -15.500 50.300 4.700 -38.000 0.000 -394.000 4.000 -358.000 8.650 -370.000 13.300 -321.000 17.950 -283.000 23.283 -292.000 28.616 -300.000 33.950 -323.000 38.950 -305.000 43.950 -163.000 47.450 -139.000 50.300 -42.000 55.000
Ligger:stramien 1 B.G:3 VB extreem
VELDBELASTINGEN Last Ref. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Type 1:q-last 1:q-last 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast
Omschrijving q2 q3 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 F13
VELDBELASTINGEN VELDBELASTINGEN
Ligger:stramien 1 B.G:3 VB extreem q1/p/m q2 psi Afstand Lengte -8.800 -11.600 17.900 32.400 -9.300 -9.300 50.300 4.700 -13.000 0.000 -150.000 4.000 -165.000 8.650 -170.000 13.300 -112.000 17.950 -86.000 23.283 -89.000 28.616 -93.000 33.950 -96.000 38.950 -92.000 43.950 -62.000 47.450 -42.000 50.300 -13.000 55.000 Ligger:stramien 1 B.G:4 wind links
Ligger:stramien 1 B.G:2 VB momentaan 223
223
F12=29F13=11 F11=43 F10=64 F5=80 F6=60 F7=62 F8=65 F9=67.2 F1=9.1 F2=98 F3=104F4=107q2=8.8 11.6 q3=9.3
VELDBELASTINGEN VELDBELASTINGEN Last Ref. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Type 1:q-last 1:q-last 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast
Omschrijving q2 q3 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 F13
Ligger:stramien 1 B.G:2 VB momentaan q1/p/m q2 psi Afstand Lengte -8.800 -11.600 17.900 32.400 -9.300 -9.300 50.300 4.700 -9.100 0.000 -98.000 4.000 -104.000 8.650 -107.000 13.300 -80.000 17.950 -60.000 23.283 -62.000 28.616 -65.000 33.950 -67.200 38.950 -64.000 43.950 -43.000 47.450 -29.000 50.300 -11.000 55.000
Bijlagen V001 - 226 van 248
Last Ref. 1 2
Type 8:Puntlast 8:Puntlast
Omschrijving
VELDBELASTINGEN
Ligger:stramien 1 B.G:4 wind links q1/p/m q2 psi Afstand Lengte 223.000 38.950 -223.000 47.450 Ligger:stramien 1 B.G:5 wind rechts
223
VELDBELASTINGEN Last Ref. 1 2
Type 8:Puntlast 8:Puntlast
Omschrijving
223
Ligger:stramien 1 B.G:5 wind rechts q1/p/m q2 psi Afstand Lengte -223.000 38.950 223.000 47.450
Bijlagen V001 - 227 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
BELASTINGCOMBINATIES BC 1 2 3 4 5 6 7 8 9 10
Type Fund. Fund. Fund. Fund. Fund. Fund. Kar. Freq. Quas. Perm.
BG 1 1 1 1 1 1 1 1 1 1
Gen. Factor Perm 1.35 Perm 1.20 Extr 1.20 Extr 1.20 Perm 0.90 Perm 0.90 Perm 1.00 Extr 1.00 Extr 1.00 Perm 1.00
BG 2 3 2 2 4 5 3 2 2
Gen. Factor Extr 1.50 Extr 1.50 Extr 1.50 Extr 1.50 Extr 1.50 Extr 1.50 Extr 1.00 Extr 1.00 Extr 0.80
BG Gen. Factor
Project......: 130583 - Saturn Duiven Onderdeel....: Dakligger hellingbaan
OMHULLENDE VAN DE FUNDAMENTELE COMBINATIES 4 Extr 5 Extr
1.50 1.50
GUNSTIGE WERKING PERMANENTE BELASTINGEN BC 1 2 3 4 5 6
BG Gen. Factor
MOMENTEN
Fysisch lineair Velden: 1 t/m 6
Ligger:stramien 1 Fundamentele combinatie
89
128
114
72
119
15.8 -8.3
Ligger:stramien 1
Velden met gunstige werking 1-12 1-12 1-12 1-12 Alle velden de factor:0.90 Alle velden de factor:0.90
-39.8
-39.9
-74
-85
-107
MOMENTEN
Fysisch lineair Velden: 7 t/m 12
Ligger:stramien 1 Fundamentele combinatie
325 277 191
166 119
74 -1.0 -101
-79
-106 -155
-282
DWARSKRACHTEN
Fysisch lineair Ligger:stramien 1 Fundamentele combinatie
Velden: 1 t/m 6
146 77
137
80
60
21.4 -55 Fmin:56 Fmax:119
Bijlagen V001 - 228 van 248
-29.4 -67 362 714
397 803
-56 392 788
-133 384 760
-141 387 759
377 764
Bijlagen V001 - 229 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
DWARSKRACHTEN
Fysisch lineair Ligger:stramien 1 Fundamentele combinatie
LIGGER:stramien 2
Velden: 7 t/m 12
GEOMETRIE
Ligger:stramien 2
291 140
150
137
ref.
148
23.2
351 778
REACTIES
1.53.6 4.5 4.5 3.9.5 18.500 1:B*H 650*500
-145
-158
Fmin:377 Fmax:764
Stp 1 2 3 4 5 6 7 8 9 10 11 12
-73
-106
-140
126 1014
Fysisch lineair Fmin Fmax 55.65 118.86 362.08 714.16 397.10 803.13 392.24 788.35 384.05 759.74 387.07 758.83 377.03 764.14 351.31 777.60 125.66 1014.04 337.31 699.10 23.26 835.73 208.07 476.98
337 699
-222 23.3 836
-187 208 477
Ligger:stramien 1 Fundamentele combinatie Mmin Mmax 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
VELDLENGTEN Veld 1 2 3 4 5
Vanaf 0.000 1.500 5.100 9.600 14.100
Tot 1.500 5.100 9.600 14.100 18.000
Lengte 1.500 3.600 4.500 4.500 3.900
Veld 6
Vanaf 18.000
Tot 18.500
VEREN Veer Steunpunt Richting Veerwaarde 1 1 2:Translatie 2.0000e+004 2 2 2:Translatie 2.0000e+004 3 3 2:Translatie 2.0000e+004 4 4 2:Translatie 2.0000e+004 5 5 2:Translatie 2.0000e+004
VELDBELASTINGEN
Ondergrens 0.0000e+000 0.0000e+000 0.0000e+000 0.0000e+000 0.0000e+000
Ligger:stramien 2 Lengte 0.500
Ligger:stramien 2 Bovengrens 0.0000e+000 0.0000e+000 0.0000e+000 0.0000e+000 0.0000e+000
Ligger:stramien 2 B.G:1 Permanent
F1=237 F2=671F3=754F4=539 F5=563 q1=14.8
VELDBELASTINGEN Last Ref. 1 2 3 4 5 6
Bijlagen V001 - 230 van 248
Type 1:q-last 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast
Omschrijving q1 F1 F2 F3 F4 F5
Ligger:stramien 2 B.G:1 Permanent q1/p/m q2 psi Afstand Lengte -14.800 -14.800 0.000 18.500 -237.000 2.000 -671.000 5.100 -754.000 9.600 -539.000 14.100 -563.000 18.000
Bijlagen V001 - 231 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
VELDBELASTINGEN
Ligger:stramien 2 B.G:2 VB momentaan
OMHULLENDE VAN DE FUNDAMENTELE COMBINATIES MOMENTEN
F1=100 F2=163F3=195F4=188 F5=174 q1=10
Fysisch lineair
Ligger:stramien 2 Fundamentele combinatie
181
VELDBELASTINGEN Last Ref. 1 2 3 4 5 6
Type 1:q-last 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast
Ligger:stramien 2 B.G:2 VB momentaan Omschrijving q1/p/m q2 psi Afstand Lengte q1 -10.000 -10.000 0.000 18.500 F1 -100.000 2.000 F2 -163.000 5.100 F3 -195.000 9.600 F4 -188.000 14.100 F5 -174.000 18.000
VELDBELASTINGEN
91
87
51 10.9 -12.0 -70
-72 -109
-162
-183
-251
Ligger:stramien 2 B.G:3 VB extreem
DWARSKRACHTEN
Fysisch lineair Ligger:stramien 2 Fundamentele combinatie
F1=142 F2=282F3=314F4=304 F5=271 q1=10
158
VELDBELASTINGEN Last Ref. 1 2 3 4 5 6
Type 1:q-last 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast
Omschrijving q1 F1 F2 F3 F4 F5
Ligger:stramien 2 B.G:3 VB extreem q1/p/m q2 psi Afstand Lengte -10.000 -10.000 0.000 18.500 -142.000 2.000 -282.000 5.100 -314.000 9.600 -304.000 14.100 -271.000 18.000
VELDBELASTINGEN
Ligger:stramien 2 B.G:4 wind links
VELDBELASTINGEN
Ligger:stramien 2 B.G:5 wind rechts
135
GUNSTIGE WERKING PERMANENTE BELASTINGEN
Ligger:stramien 2
6.5
4.7
81
-97
-92
-22.8
-562 Fmin:269 Fmax:626
REACTIES
BC 1 2 3 4 5 6
126
68
Stp 1 2 3 4 5
689 1434
Fysisch lineair Fmin Fmax 268.97 625.55 689.09 1433.56 763.29 1590.33 602.28 1337.88 540.26 1184.09
763 1590
-129
602 1338
540 1184
Ligger:stramien 2 Fundamentele combinatie Mmin Mmax 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Velden met gunstige werking 1-6 1-6 1-6 1-6 Alle velden de factor:0.90 Alle velden de factor:0.90
Bijlagen V001 - 232 van 248
Bijlagen V001 - 233 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
LIGGER:stramien 7
VELDBELASTINGEN
GEOMETRIE
Ligger:stramien 7
Ligger:stramien 7 B.G:1 Permanent
F1=225F2=392F3=329 F4=314 F5=286 F6=348F7=394F8=381 F9=389F10=370F11=437 F12=178 q1=22.2 q2=20.8
ref.
VELDBELASTINGEN
.92 4.6654.665 4.25
4
4
5.083 5.083 5.084 5.084 5.083 5.083 53.000 1:B*H 650*500
VELDLENGTEN Veld 1 2 3 4 5
Vanaf 0.000 0.920 5.585 10.250 14.500
Tot 0.920 5.585 10.250 14.500 18.500
Lengte 0.920 4.665 4.665 4.250 4.000
11 12
42.834 47.917
47.917 53.000
5.083 5.083
Veld 6 7 8 9 10
Vanaf 18.500 22.500 27.583 32.666 37.750
Tot 22.500 27.583 32.666 37.750 42.834
6 7 8 9 10 11 12
6 7 8 9 10 11 12
2:Translatie 2:Translatie 2:Translatie 2:Translatie 2:Translatie 2:Translatie 2:Translatie
2.0000e+004 2.0000e+004 2.0000e+004 2.0000e+004 2.0000e+004 2.0000e+004 2.0000e+004
Type 1:q-last 1:q-last 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast
Omschrijving q1 q2 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12
VELDBELASTINGEN
VEREN Veer Steunpunt Richting Veerwaarde 1 1 2:Translatie 2.0000e+004 2 2 2:Translatie 2.0000e+004 3 3 2:Translatie 2.0000e+004 4 4 2:Translatie 2.0000e+004 5 5 2:Translatie 2.0000e+004
Ligger:stramien 7 Lengte 4.000 5.083 5.083 5.084 5.084
Last Ref. 1 2 3 4 5 6 7 8 9 10 11 12 13 14
Ondergrens 0.0000e+000 0.0000e+000 0.0000e+000 0.0000e+000 0.0000e+000
Ligger:stramien 7 Bovengrens 0.0000e+000 0.0000e+000 0.0000e+000 0.0000e+000 0.0000e+000
0.0000e+000 0.0000e+000 0.0000e+000 0.0000e+000 0.0000e+000 0.0000e+000 0.0000e+000
0.0000e+000 0.0000e+000 0.0000e+000 0.0000e+000 0.0000e+000 0.0000e+000 0.0000e+000
Bijlagen V001 - 234 van 248
Ligger:stramien 7 B.G:1 Permanent q1/p/m q2 psi Afstand Lengte -22.200 -22.200 0.000 10.250 -20.800 -20.800 10.250 42.750 -225.000 0.920 -392.000 5.585 -329.000 10.250 -314.000 14.500 -286.000 18.500 -348.000 22.500 -394.000 27.583 -381.000 32.666 -389.000 37.750 -370.000 42.834 -437.000 47.917 -178.000 53.000 Ligger:stramien 7 B.G:2 VB momentaan
F1=54.8 F2=95.6 F3=88.4 F4=85.4 F5=83.1 F6=93.3 F7=100.5 F8=100.9 F9=102.4 F10=100.5 F11=105.4 F12=42.7 q1=4.2 q2=4.2
VELDBELASTINGEN Last Ref. 1 2 3 4 5 6 7 8 9 10 11 12 13 14
Type 1:q-last 1:q-last 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast
Omschrijving q1 q2 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12
Ligger:stramien 7 B.G:2 q1/p/m q2 psi -4.200 -4.200 -4.200 -4.200 -54.800 -95.600 -88.400 -85.400 -83.100 -93.300 -100.500 -100.900 -102.400 -100.500 -105.400 -42.700
VB momentaan Afstand Lengte 0.000 10.250 10.250 42.750 0.920 5.585 10.250 14.500 18.500 22.500 27.583 32.666 37.750 42.834 47.917 53.000
Bijlagen V001 - 235 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
VELDBELASTINGEN
Ligger:stramien 7 B.G:3 VB extreem
OMHULLENDE VAN DE FUNDAMENTELE COMBINATIES F1=110.9 F2=197F3=182 F4=176 F5=171 F6=192F7=207F8=208 F9=211F10=207F11=217 F12=83.8 q1=10.4 q2=10.4
VELDBELASTINGEN Last Ref. 1 2 3 4 5 6 7 8 9 10 11 12 13 14
Type 1:q-last 1:q-last 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast
Omschrijving q1 q2 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12
VELDBELASTINGEN
Ligger:stramien 7 B.G:3 VB extreem q1/p/m q2 psi Afstand Lengte -10.400 -10.400 0.000 10.250 -10.400 -10.400 10.250 42.750 -110.900 0.920 -197.000 5.585 -182.000 10.250 -176.000 14.500 -171.000 18.500 -192.000 22.500 -207.000 27.583 -208.000 32.666 -211.000 37.750 -207.000 42.834 -217.000 47.917 -83.800 53.000 Ligger:stramien 7 B.G:4 wind links
MOMENTEN
Fysisch lineair Velden: 1 t/m 7
Ligger:stramien 7 Fundamentele combinatie
236
233
175
164 135
78 22.2 -37.4
-39.1
-38.6
-117
-143
-148
MOMENTEN
Fysisch lineair Velden: 8 t/m 12
164
-142
Ligger:stramien 7 Fundamentele combinatie
162
144
133 81
274
274
VELDBELASTINGEN Last Ref. 1 2
Type 8:Puntlast 8:Puntlast
Omschrijving
VELDBELASTINGEN
23.9
Ligger:stramien 7 B.G:4 wind links q1/p/m q2 psi Afstand Lengte 274.000 14.500 -274.000 22.500 Ligger:stramien 7 B.G:5 wind rechts
274
-22.6
-38.6 -101
-117 -159
DWARSKRACHTEN
Fysisch lineair Ligger:stramien 7 Fundamentele combinatie
Velden: 1 t/m 7
274
134
VELDBELASTINGEN Last Ref. 1 2
Type 8:Puntlast 8:Puntlast
Omschrijving
Ligger:stramien 7 B.G:5 wind rechts q1/p/m q2 psi Afstand Lengte -274.000 14.500 274.000 22.500
GUNSTIGE WERKING PERMANENTE BELASTINGEN BC 1 2 3 4 5 6
-77
-86
6.2
132
153 121
2.6 -14.9
-132 Fmin:290 Fmax:616
Bijlagen V001 - 236 van 248
142
47.5
Ligger:stramien 7
Velden met gunstige werking 1-12 1-12 1-12 1-12 Alle velden de factor:0.90 Alle velden de factor:0.90
143
-114 455 1000
-121 -152 355 933
64 987
-128 365 831
-150 96 1077
427 1057
Bijlagen V001 - 237 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
DWARSKRACHTEN
Fysisch lineair Ligger:stramien 7 Fundamentele combinatie
Velden: 8 t/m 12
LIGGER:stramien A Profiel : B*H 650*500
142
136
GEOMETRIE
145 116
Ligger:stramien A
126 ref.
-135 Fmin:427 Fmax:1057
463 1052
4.5 5.250 5.250
-132
-141
475 1052
-156 479 1056
5
-143 514 1096
221 465
5
5 5 55.000 1:B*H 650*500
5
5
VELDLENGTEN REACTIES Stp 1 2 3 4 5 6 7 8 9 10 11 12
Fysisch lineair Fmin Fmax 289.65 616.29 455.11 1000.20 355.28 933.48 64.34 987.30 364.96 830.51 95.80 1076.62 426.80 1057.25 462.83 1051.75 475.22 1051.67 479.49 1055.84 514.43 1095.76 220.66 465.33
Ligger:stramien 7 Fundamentele combinatie Mmin Mmax 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Bijlagen V001 - 238 van 248
Veld 1 2 3 4 5
Vanaf 0.000 4.500 9.750 15.000 20.000
Tot 4.500 9.750 15.000 20.000 25.000
Lengte 4.500 5.250 5.250 5.000 5.000
11
50.000
55.000
5.000
Veld 6 7 8 9 10
Vanaf 25.000 30.000 35.000 40.000 45.000
Tot 30.000 35.000 40.000 45.000 50.000
VEREN Veer Steunpunt Richting Veerwaarde 1 1 2:Translatie 2.0000e+004 2 2 2:Translatie 2.0000e+004 3 3 2:Translatie 2.0000e+004 4 4 2:Translatie 2.0000e+004 5 5 2:Translatie 2.0000e+004 6 7 8 9 10
6 7 8 9 10
2:Translatie 2:Translatie 2:Translatie 2:Translatie 2:Translatie
2.0000e+004 2.0000e+004 2.0000e+004 2.0000e+004 2.0000e+004
11 12
11 2:Translatie 2.0000e+004 12 2:Translatie 2.0000e+004
5
5
Ligger:stramien A Lengte 5.000 5.000 5.000 5.000 5.000
Ondergrens 0.0000e+000 0.0000e+000 0.0000e+000 0.0000e+000 0.0000e+000
Ligger:stramien A Bovengrens 0.0000e+000 0.0000e+000 0.0000e+000 0.0000e+000 0.0000e+000
0.0000e+000 0.0000e+000 0.0000e+000 0.0000e+000 0.0000e+000
0.0000e+000 0.0000e+000 0.0000e+000 0.0000e+000 0.0000e+000
0.0000e+000 0.0000e+000 0.0000e+000 0.0000e+000
Bijlagen V001 - 239 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
VELDBELASTINGEN
q1=14.3
Ligger:stramien A B.G:1 Permanent
F1=185 F2=348 F3=319F4=190F5=202F6=49 F7=74 F8=66 F9=65 F10=76 q2=23.8 Q3=20.1
VELDBELASTINGEN Last Ref. 1 2 3 4 5 6 7 8 9 10 11 12 13
Type 1:q-last 1:q-last 1:q-last 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast
VELDBELASTINGEN
q1=8.1
VELDBELASTINGEN
Omschrijving q1 q2 Q3 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10
Ligger:stramien A B.G:1 Permanent q1/p/m q2 psi Afstand Lengte -14.300 -14.300 0.000 4.500 -23.800 -23.800 4.500 40.500 -20.100 -20.100 45.000 10.000 -185.000 4.500 -348.000 9.750 -319.000 15.000 -190.000 20.000 -202.000 25.000 -49.000 30.000 -74.000 35.000 -66.000 40.000 -65.000 45.000 -76.000 50.000 Ligger:stramien A B.G:2 VB momentaan
q1=8.1
Ligger:stramien A B.G:3 VB extreem
F1=27 F2=192 F3=188F4=205F5=150F6=12 F7=22 F8=21 F9=21 F10=21 q2=11.3 Q3=8.1
VELDBELASTINGEN Last Ref. 1 2 3 4 5 6 7 8 9 10 11 12 13
Type 1:q-last 1:q-last 1:q-last 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast
Omschrijving q1 q2 Q3 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10
VELDBELASTINGEN
F1=18.9F2=134.4 F3=131.6 F4=143.5 F5=105F6=6.6F7=10.6 F8=10.2 F9=10.2 F10=10.2 q2=4.5 Q3=3.3
Ligger:stramien A B.G:4 wind links
Fw=223
VELDBELASTINGEN VELDBELASTINGEN Last Ref. 1 2 3 4 5 6 7 8 9 10 11 12 13
Type 1:q-last 1:q-last 1:q-last 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast
Ligger:stramien A B.G:2 Omschrijving q1/p/m q2 psi q1 -8.100 -8.100 q2 -4.500 -4.500 Q3 -3.300 -3.300 F1 -18.900 F2 -134.400 F3 -131.600 F4 -143.500 F5 -105.000 F6 -6.600 F7 -10.600 F8 -10.200 F9 -10.200 F10 -10.200
VB momentaan Afstand Lengte 0.000 4.500 4.500 40.500 45.000 10.000 4.500 9.750 15.000 20.000 25.000 30.000 35.000 40.000 45.000 50.000
Last Ref. 1 2
Type 8:Puntlast 8:Puntlast
Omschrijving Fw Fw
VELDBELASTINGEN
VELDBELASTINGEN Type 8:Puntlast 8:Puntlast
Fw=223
Ligger:stramien A B.G:4 wind links q1/p/m q2 psi Afstand Lengte 223.000 15.000 -223.000 25.000 Ligger:stramien A B.G:5 wind rechts
Fw=223
Last Ref. 1 2
Ligger:stramien A B.G:3 VB extreem q1/p/m q2 psi Afstand Lengte -8.100 -8.100 0.000 4.500 -11.300 -11.300 4.500 40.500 -8.100 -8.100 45.000 10.000 -27.000 4.500 -192.000 9.750 -188.000 15.000 -205.000 20.000 -150.000 25.000 -12.000 30.000 -22.000 35.000 -21.000 40.000 -21.000 45.000 -21.000 50.000
Omschrijving Fw Fw
Fw=223
Ligger:stramien A B.G:5 wind rechts q1/p/m q2 psi Afstand Lengte -223.000 15.000 223.000 25.000
GUNSTIGE WERKING PERMANENTE BELASTINGEN BC 1 2 3 4 5 6 Bijlagen V001 - 240 van 248
Ligger:stramien A
Velden met gunstige werking 1-11 1-11 1-11 1-11 Alle velden de factor:0.90 Alle velden de factor:0.90 Bijlagen V001 - 241 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
OMHULLENDE VAN DE FUNDAMENTELE COMBINATIES
DWARSKRACHTEN
Fysisch lineair Ligger:stramien A Fundamentele combinatie
Velden: 7 t/m 11
MOMENTEN
Fysisch lineair Velden: 1 t/m 6
Ligger:stramien A Fundamentele combinatie 130 210
189
169
151
141
139 109
101
207
114 11.1
-56
-74 -135
-67 -120
-136
-137
-155 Fmin:159 Fmax:405
189 388
Fysisch lineair Velden: 7 t/m 11
Ligger:stramien A Fundamentele combinatie
207 113
102
112 73 16.9
-69
196 371
-129 198 360
53 101
Stp 1 2 3 4 5 6 7 8 9 10 11 12
Fysisch lineair Fmin Fmax 23.86 78.68 282.69 540.02 420.75 985.02 143.47 1104.90 327.76 838.55 22.72 879.57 158.59 404.54 189.34 388.45 202.49 390.68 196.42 370.97 197.52 359.68 52.91 101.47
Ligger:stramien A Fundamentele combinatie Mmin Mmax 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
-67
-75
-82
202 391
-123
-125
-139
REACTIES MOMENTEN
-139
-113
DWARSKRACHTEN
Fysisch lineair Ligger:stramien A Fundamentele combinatie
Velden: 1 t/m 6
154
158
153
117
172 134
-79
Fmin:23.9 Fmax:79
-165 283 540
-146 421 985
-143 143 1105
-159 328 839
-137 22.7 880
159 405
Bijlagen V001 - 242 van 248
Bijlagen V001 - 243 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
LIGGER:stramien H
VELDBELASTINGEN
GEOMETRIE
Ligger:stramien H
Ligger:stramien H B.G:1 Permanent
F1=39F2=371F3=73 F4=409 q1=18.6
F5=78 F6=445 q2=23.8
F7=443 F8=16
ref.
VELDBELASTINGEN
4
4 5 18.000
5
6.200 4.8 5 5 1 30.000 1:B*H 650*500
5
5
VELDLENGTEN Veld 1 2 3 4 5
Vanaf 0.000 4.000 8.000 13.000 18.000
Tot 4.000 8.000 13.000 18.000 24.200
Lengte 4.000 4.000 5.000 5.000 6.200
Veld 6 7 8 9 10
Vanaf 24.200 29.000 34.000 39.000 44.000
Tot 29.000 34.000 39.000 44.000 49.000
DOORSNEDEN sector 1 2 3 sector 1 2 3
Vanaf 0.000 18.000 19.000 Vanaf 0.000 18.000 19.000
Tot 18.000 19.000 49.000 Tot 18.000 19.000 49.000
Lengte Profiel begin z-begin 18.000 1:B*H 650*500 0.000 1.000 1:B*H 650*500 0.000 30.000 1:B*H 650*500 0.000 Lengte Eindcode Bedding Br.[mm] 18.000 1:Vast 1.000 1:Vast 30.000 1:Vast
VEREN Veer Steunpunt Richting Veerwaarde 1 1 2:Translatie 2.0000e+004 2 2 2:Translatie 2.0000e+004 3 3 2:Translatie 2.0000e+004 4 4 2:Translatie 2.0000e+004 5 5 2:Translatie 2.0000e+004 6 7 8 9 10 11
6 7 9 10 11
2:Translatie 2:Translatie 2:Translatie 2:Translatie 2:Translatie
2.0000e+004 2.0000e+004 2.0000e+004 2.0000e+004 2.0000e+004
8 2:Translatie 2.0000e+004
Ligger:stramien H Lengte 4.800 5.000 5.000 5.000 5.000
Ligger:stramien H Profiel eind z-eind 1:B*H 650*500 0.000 1:B*H 650*500 0.000 1:B*H 650*500 0.000
Ondergrens 0.0000e+000 0.0000e+000 0.0000e+000 0.0000e+000 0.0000e+000
Ligger:stramien H Bovengrens 0.0000e+000 0.0000e+000 0.0000e+000 0.0000e+000 0.0000e+000
0.0000e+000 0.0000e+000 0.0000e+000 0.0000e+000 0.0000e+000
0.0000e+000 0.0000e+000 0.0000e+000 0.0000e+000 0.0000e+000
Last Ref. 1 2 3 4 5 6 7 8 9 10
Type 1:q-last 1:q-last 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast
Omschrijving q1 q2 F1 F2 F3 F4 F5 F6 F7 F8
VELDBELASTINGEN
Ligger:stramien H B.G:2 VB momentaan
F1=8 F2=101F3=11 F4=109 q1=8.1
VELDBELASTINGEN Last Ref. 1 2 3 4 5 6 7 8 9 10
Type 1:q-last 1:q-last 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast
Ligger:stramien H B.G:1 Permanent q1/p/m q2 psi Afstand Lengte -18.600 -18.600 0.000 19.000 -23.800 -23.800 19.000 30.000 -39.000 4.000 -371.000 8.000 -73.000 13.000 -409.000 18.000 -78.000 24.550 -445.000 29.000 -443.000 39.000 -16.000 42.400
Omschrijving q1 q2 F1 F2 F3 F4 F5 F6 F7 F8
F5=11 F6=99 q2=4.5
F7=99 F8=3
Ligger:stramien H B.G:2 q1/p/m q2 psi -8.100 -8.100 -4.500 -4.500 -8.000 -101.000 -11.000 -109.000 -11.000 -99.000 -99.000 -3.000
VB momentaan Afstand Lengte 0.000 19.000 19.000 30.000 4.000 8.000 13.000 18.000 24.550 29.000 39.000 42.400
0.0000e+000 0.0000e+000
Bijlagen V001 - 244 van 248
Bijlagen V001 - 245 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond
Project: Wand Engelman Architecten Roerdelta te Roermond
Projectnr: 110997
Projectnr: 110997
VELDBELASTINGEN
Ligger:stramien H B.G:3 VB extreem
F1=17F2=198F3=21 F4=220 q1=8.1
Type 1:q-last 1:q-last 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast 8:Puntlast
F7=215 F8=6
MOMENTEN
Fysisch lineair Velden: 1 t/m 6
Ligger:stramien H Fundamentele combinatie
380
VELDBELASTINGEN Last Ref. 1 2 3 4 5 6 7 8 9 10
F5=22 F6=216 q2=11.3
OMHULLENDE VAN DE FUNDAMENTELE COMBINATIES
Omschrijving q1 q2 F1 F2 F3 F4 F5 F6 F7 F8
Ligger:stramien H B.G:3 VB extreem q1/p/m q2 psi Afstand Lengte -8.100 -8.100 0.000 19.000 -11.300 -11.300 19.000 30.000 -17.000 4.000 -198.000 8.000 -21.000 13.000 -220.000 18.000 -22.000 24.550 -216.000 29.000 -215.000 39.000 -6.000 42.400
312 195 85
68 10.3 -68
MOMENTEN VELDBELASTINGEN
Ligger:stramien H B.G:4 wind links
Fw=223
-177
-188
-231
Fysisch lineair Velden: 7 t/m 10
Ligger:stramien H Fundamentele combinatie
395
Fw=223
253
VELDBELASTINGEN Last Ref. 1 2
Type 8:Puntlast 8:Puntlast
Omschrijving Fw Fw
Ligger:stramien H B.G:4 wind links q1/p/m q2 psi Afstand Lengte 223.000 8.000 -223.000 18.000
13.8
-92
VELDBELASTINGEN
Ligger:stramien H B.G:5 wind rechts
Fw=223
Fw=223
-178
-205
DWARSKRACHTEN
Fysisch lineair Ligger:stramien H Fundamentele combinatie
Velden: 1 t/m 6
VELDBELASTINGEN Last Ref. 1 2
Type 8:Puntlast 8:Puntlast
Omschrijving Fw Fw
Ligger:stramien H B.G:5 wind rechts q1/p/m q2 psi Afstand Lengte -223.000 8.000 223.000 18.000
GUNSTIGE WERKING PERMANENTE BELASTINGEN BC 1 2 3 4 5 6
90
Ligger:stramien H
Velden met gunstige werking 1-10 1-10 1-10 1-10 Alle velden de factor:0.90 Alle velden de factor:0.90
-77
-78
Fmin:5.6 Fmax:77
121 386
84
77
-10.3
-22.8 -118
-191
-192
Bijlagen V001 - 246 van 248
244
206 136
100 934
254 512
153 1086
-361 270 605
433 943
Bijlagen V001 - 247 van 248
Project: Wand Engelman Architecten Roerdelta te Roermond Projectnr: 110997
DWARSKRACHTEN
Fysisch lineair Ligger:stramien H Fundamentele combinatie
Velden: 7 t/m 10
248
238 100
70 21.0 -20.6 -98
-70
-188 -247 243 495
Fmin:433 Fmax:943
REACTIES Stp 1 2 3 4 5 6 7 8 9 10 11
457 962
Fysisch lineair Fmin Fmax 5.61 77.49 120.76 386.11 99.71 934.26 253.80 511.82 152.57 1085.59 270.13 605.07 432.87 942.96 242.94 495.02 457.41 961.93 213.99 425.22 31.49 100.42
214 425
31.5 100
Ligger:stramien H Fundamentele combinatie Mmin Mmax 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Bijlagen V001 - 248 van 248