Technical Slides
SIMATIC S7-1500 Rostislav Kosek Industry Sector IA AS Restricted / © Siemens AG 2014. All Rights Reserved.
SIMATIC S7-400
The modular controller for solutions Thesystem modular controller for system solutions for discrete as well as for discrete as well process automation as process automation
SIMATIC S7-300
The modular controller for solutions Thesystem modular controller for system solutions for discrete automation for discrete automation
SIMATIC S7-1200
The modular compact controller for solutions in the lower performance range for discrete and stand-alone automation
SIMATIC S7-1500
Application complexity
SIMATIC S7-1500 Positioning
Number of I/Os, program size, instruction speed, communication properties, …
Restricted / © Siemens AG 2014. All Rights Reserved. Page 2
I IA AS, R. Kosek
SIMATIC S7-1500 The Ultimate Plus in Automation
• Maximum performance for minimized production cycles • Technology integrated for perfect drive integration via motion control functions • Security integrated for improved intellectual property and investment protection • One system for safety and standard applications
• Excellent usability for reduced commissioning and maintenance times • Reduced downtimes through integrated system diagnostics • Minimized development times through increased engineering efficiency Restricted / © Siemens AG 2014. All Rights Reserved. Page 3
I IA AS, R. Kosek
SIMATIC S7-1500 Design
Restricted / © Siemens AG 2014. All Rights Reserved. Page 4
I IA AS, R. Kosek
SIMATIC S7-1500 Highlights
Portfolio • One system for machine and plant engineering • Reduction of modules by >50% with CPU • Reduction of modules by >30% with I/O
Restricted / © Siemens AG 2014. All Rights Reserved. Page 5
I IA AS, R. Kosek
SIMATIC S7-1500 aktuální stav, jednotky CPU New in V13
New in V13
PROFIBUS PROFINET / IE
CPU
S7-1511
S7-1513
S7-1515
S7-1516
S7-1518
1511-1 PN
1513-1 PN
1515-2 PN
1516-3 PN/DP
1518-4 PN/DP
1
1
1
1
1
1
150 KB 1 MB
300 KB 1,5 MB
500 KB 3 MB
1 MB 5 MB
3 MB 10 MB
60 ns
40 ns
30 ns
10 ns
1 ns
35 mm
35 mm
70 mm
70 mm
175 mm
Rozhraní Program / data memory Bit performance Ší ka
2
1
2
1
1
2
1
3
Optimální výb r CPU Restricted / © Siemens AG 2014. All Rights Reserved. Page 6
I IA AS, R. Kosek
SIMATIC S7-1500 Delivery Stage 1
CPU-1511 / 1513
CPU-1516
IM
5x PS / PM
6x CM / CP
13x I/Q
2xTM
Restricted / © Siemens AG 2014. All Rights Reserved. Page 7
I IA AS, R. Kosek
SIMATIC S7-1500 Delivery Stage 2 CPUs
CPU-1515
CPU-1518
25 mm module
3x DI/DQ
CM / CP
2 x CM/CP
Restricted / © Siemens AG 2014. All Rights Reserved. Page 8
I IA AS, R. Kosek
SIMATIC S7-1500 Highlights Hardware • Max. 32 modules / line • Identical modules for U-connector and backplane assembly • Sufficient memory for any application • Load memory via SIMATIC memory card
Performance • Extremely fast backplane bus • Extremely fast bit instructions • Extremely short response time (terminal <-> terminal)
Portfolio • One system for machine and plant engineering • Reduction of modules by >50% with CPU • Reduction of modules by >30% with I/O
Restricted / © Siemens AG 2014. All Rights Reserved. Page 9
I IA AS, R. Kosek
SIMATIC S7-1500 provedení S7-300, ET200M • S7-300 central: až 32 modul , ALE: jsou pot eba další IM moduly • ET 200M distributed: až 12 modul
S7-1500 • S7-1500 central a také ET 200MP distributed: • až 31 modul bez ídavných IM
Max. 32 I/O modul
Úspora místa díky mén použitých IM Úspora náklad Restricted / © Siemens AG 2014. All Rights Reserved. Page 10
I IA AS, R. Kosek
SIMATIC S7-1500 – Power Supply Concept Definice: Load Power Supply / System Power Supply
S7-300: PS
S7-1500: PM
PS307 24V/2A PS307 24V/5A PS307 24V/10A
PM1507 24 V/3 A PM1507 24 V/8 A
S7-400: PS
S7-1500: PS
Load power supply
System power supply
PM = Powermodule
PS = Power supply module
• Základní 24VDC napájení všech modul
• Interní napájení p es backplane bus (interní elektoniky / komunikace)
• tozn. (PS, PLC, IM) ale i senzor /aktor
• V rámci jedné sestavy lze zapojit jeden nebo více a tvo it segmenty
• Bez U-konektoru
• S U-konektorem
• Bez diagnostiky a dopl kových informací v TIA Portal
• S diagnostikou a dopl kovými informacemi v TIA Portal
Restricted / © Siemens AG 2014. All Rights Reserved. Page 11
I IA AS, R. Kosek
SIMATIC S7-1500 Aplikace: Load Power Supply / System Power Supply Basic configuration
Basic+ configuration
With PM (load power supply)
PM (load power supply) and PM
PS (system power supply)
PS
PS
PM PS
power segment 1
power segment 1
power segment 2
power segment 3
Extended configuration (SITOP and PS) Optional realization of "all-round protection"
SITOP
PS
PS
PS Redundancy Uninterruptible power supply DC-UPS power segment 1
power segment 2
power segment 3
Maximum of 32 modules
Restricted / © Siemens AG 2014. All Rights Reserved. Page 12
I IA AS, R. Kosek
SIMATIC S7-1500 – Power Supply Concept Basic Configuration (Load Power Supply PM) Load power supply (PM)…. • No connection for the backplane bus • CPU feeds the system with 10-12 W via the backplane • No PS required for this configuration! ….for 24VDC supply of: • CPU / IM, input/output circuits of modules • Sensors and actuators • Additional system power supply modules (PS)
PM1507 70W
System power supply of the CPU via the backplane bus
PM
Modules (IO, CM, CP, TM)
CPU / IM
Power segment 1 (max. 10 modules*)
24 V/ 3 A
120/230V AC Eingang 6EP1332-4BA00
PM1507 190W 24 V/ 8 A 120/230V AC Eingang 6EP1333-4BA00
DC 24 V AC 120/230 V Sensors
Actuators
* Max. number of modules depending on the modules' power consumption
Restricted / © Siemens AG 2014. All Rights Reserved. Page 13
I IA AS, R. Kosek
SIMATIC S7-1500 – Power Supply Concept Basic + Configuration (with Load Power Supply PM and System Power Supply PS) System power supply (PS)… • Supplies the internally required system voltage for the backplane bus • PM required for 24VDC supply …for supply of: • Module electronics • LEDs (via the backplane bus) • Backplane bus of CPU / IM / modules
System power supply of the CPU and PS via the backplane bus
PM
CPU / IM
Modules (IO, CM, CP, TM)
PS
power segment 1 (max. 10 modules*)
Modules (IO, CM, CP, TM)
power segment 2 (max. n modules**)
PS 25W 24VDC input 6ES7505-0KA00-0AB0 PS 60W 24/48/60VDC input 6ES7505-0KA00-0RA0 PS 60W 120/230V AC/DC input 6ES7507-0KA00-0RA0
DC 24 V
AC 120/230 V
Sensors
Actuators
Restricted / © Siemens AG 2014. All Rights Reserved. Page 14
I IA AS, R. Kosek
SIMATIC S7-1500 Highlights Hardware • Max. 32 modules / line • Identical modules for U-connector and backplane assembly • Sufficient memory for any application • Load memory via SIMATIC memory card
Performance • Extremely fast backplane bus • Extremely fast bit instructions • Extremely short response time (terminal <-> terminal)
Communication • PN IO RT/IRT in every CPU • 2 additional interfaces for network separation • All I/O data (PLC, CM) in the process image • Easy communication programming for PLC & CMs • Integrated web server
Portfolio • One system for machine and plant engineering • Reduction of modules by >50% with CPU • Reduction of modules by >30% with I/O
Restricted / © Siemens AG 2014. All Rights Reserved. Page 15
I IA AS, R. Kosek
SIMATIC S7-1500 Komunikace Identické PROFINET funkce na každém CPU • PROFINET jako standardní rozhraní pro p ipojení na úrovni tech. procesu • PROFINET IO IRT (v etn izochronní komunikace) • iDevice • Shared Device / Shared iDevice • Od CPU 1515 výše, každé CPU nabízí druhé rozhraní pro odd lení sítí • Web server s uživatelskými webovými stránkami • Volitelný p ístup na MC (memory card) p es web server Dopl kové PROFIBUS a PROFINET komunika ní moduly • enos dat z r zných míst p ímo do CPU • Uniformní SEND/RECEIVE bloky (TSEND, TRCV) pro komunikaci p es integrovaná rozhraní CPU i p es rozhraní CM (communication module) MODBUS TCP pro CPU i komunika ní karty • Komunikace Modbus master / slave
Restricted / © Siemens AG 2014. All Rights Reserved. Page 16
I IA AS, R. Kosek
SIMATIC S7-1500 Uniform Communication Blocks Configured connections
Programmed connections
Uniform communication blocks
CPU
CM
1 1
2
CP
1
1
1
Restricted / © Siemens AG 2014. All Rights Reserved. Page 17
I IA AS, R. Kosek
SIMATIC S7-1500 Komunika ní karty PROFIBUS PROFINET / IE
Type Interfaces Function
Ind. Ethernet
PROFINET
PROFIBUS
PROFIBUS
CP 1543-1
CM 1542-1
CM 1542-5
CP 1542-5
1
1
1
1
1
1
Security function IT functions S7 communication Open communication Incl. ISO communication
PN IO controller S7 communication Open communication
PB master / PB slave S7 communication Open communication
PB master / PB slave S7 routing
IPv6 support
128 I/O devices
125 DP slaves
32 DP slaves
6GK7543-1AX00-0XE0
6GK7542-1AX00-0XE0
6GK7542-5DX00-0XE0
6GK7542-5FX00-0XE0
Výb r vhodného CP/CM na základ funk ního rozsahu karet Restricted / © Siemens AG 2014. All Rights Reserved. Page 18
I IA AS, R. Kosek
SIMATIC S7-1500 PROFIBUS CM 1542-5 and CP 1542-5 – Function Overview CM 1542-5
Functions
CP 1542-5
• Communication services • PROFIBUS DP • S7 communication (max. 48 connections) • PG/OP communication, incl. S7 routing • Data record routing
• Communication services • PROFIBUS DP • S7 communication (max. 16 connections) • PG/OP communication, incl. S7 routing
• Connection of 125 DP slaves
• Connection of 32 DP slaves
PROFIBUS CM 1542-5 CP 1542-5
• Diagnostics • Web diagnostics via access to the web server of S7-1500
• Diagnostics • Web diagnostics via access to the web server of S7-1500
DP master DP slave
• Time synchronization (time master or time slave)
• Time synchronization (time master or time slave)
Assembly • 9-pole Sub-D socket for connection to PROFIBUS • Mounting on S7-1500 DIN rail • Module replacement without programming device
Restricted / © Siemens AG 2014. All Rights Reserved. Page 19
I IA AS, R. Kosek
SIMATIC S7-1500 PROFIBUS CM 1542-5 and CP 1542-5 in Comparison CM 1542-5
CP 1542-5
125
32
Address range inputs as DP master
8192 bytes
2048 bytes
Address range outputs as DP master
8192 bytes
2048 bytes
DP-V1 master
48
16
Number of configurable S7 connections
40
16
DP-V1 Master
Number of DP slaves
DP-V1 slave PG/OP communication PROFIBUS CM 1542-5 CP 1542-5 DP master DP slave
Data record routing Time synchronization (master or slave) Web diagnostics via web server of the CPU
Restricted / © Siemens AG 2014. All Rights Reserved. Page 20
I IA AS, R. Kosek
SIMATIC S7-1500 PROFINET CM 1542-1 – Function Overview Functions • Communication services • PROFINET IO controller with realtime properties: RT and IRT • Connection of 128 PN IO devices • Open communication (TCP/IP, UDP (Multicast)) • PG/OP communication, incl. S7 routing • S7 communication (client, server) • IP address assignment via DCP PROFIBUS CM 1542-1
I/O controller
• Media redundancy MRP • MRP manager or MRP client
• Diagnostics and network management • Web diagnostics via access to the web server of S7-1500 • Integration in network management systems such as SINEMA Server via SNMP V1 • Time synchronization via NTP
Assembly • Two RJ45 ports (integrated 2-port switch) for connection to PROFINET with 10/100 Mbit/s full/half-duplex • Mounting on S7-1500 DIN rail • Module replacement without programming device
• Security mechanisms • Web server access via HTTP(S) • Secure firmware update
Restricted / © Siemens AG 2014. All Rights Reserved. Page 21
I IA AS, R. Kosek
SIMATIC S7-1500 Industrial Ethernet CP 1543-1 – Function Overview Functions
Industrial Ethernet CP 1543-1
• Communication services • Communication with SIMATIC systems • IT communication FTP (client/server) and e-mail • S7 communication (client/server) • PG/OP communication, incl. S7 routing • Open communication via ISO, TCP/IP, UDP (Broadcast/Multicast) • IPv6 support • Security mechanisms • Access protection by means of firewall
• Protection against data manipulation by means of VPN, FTPS, HTTPS, SNMPv3 and secure NTP • Secure firmware update • Diagnostics and network management • Web diagnostics via access to the web server of S7-1500 • Integration in network management systems such as SINEMA Server via SNMP V1/V3
Assembly • One RJ45 port for connection to Industrial Ethernet with 10/100/1000 Mbit/s full/halfduplex • Mounting on S7-1500 DIN rail • Module replacement without programming device
• Time synchronization via NTP or secure NTP
Restricted / © Siemens AG 2014. All Rights Reserved. Page 22
I IA AS, R. Kosek
SIMATIC S7-1500 Security for S7-1500 via CP 1543-1 Customer benefits • Secure connection of S7-1500 to Industrial Ethernet by means of integrated security functions (firewall and VPN) • Additional communication options such as easy alerting via e-mail and transfer of production data to host computer by means of FTP(S) file transfer • Network separation facilitates the assembly of identical machines with identical IP addresses
CP 1543-1 offers secure connection of S7-1500 to Industrial Ethernet networks Restricted / © Siemens AG 2014. All Rights Reserved. Page 23
I IA AS, R. Kosek
SIMATIC S7-1500 Connection to IPv6-Based Networks for S7-1500 via CP 1543-1 Customer benefits • Accessibility of the S7-1500 system via an IPv6-based network by means of CP • Communication from and to S7-1500 is realized by means of the services FTP, SMTP and FETCH/WRITE • Migration to new network structures on the basis of IPv6
CP 1543-1 facilitates the connection of S7-1500 to an IPv6-based Ethernet network Restricted / © Siemens AG 2014. All Rights Reserved. Page 24
I IA AS, R. Kosek
SIMATIC S7-1500 Shared I-Device Shared I-Device • ístup do S7-1500 jako I-Device až ty em PLC • Rychlá vým na dat v reálném ase mezi S7-1500 CPUs • Klidn i integrace do PROFINET sítí t etích stran
Controller 1
Controller 2
íklad: Logické p azení jedné stanice dv ma kontrolér m (PLC) Restricted / © Siemens AG 2014. All Rights Reserved. Page 25
I IA AS, R. Kosek
SIMATIC S7-1500 Highlights Hardware • Max. 32 modules / line • Identical modules for U-connector and backplane assembly • Sufficient memory for any application • Load memory via SIMATIC memory card
Performance • Extremely fast backplane bus • Extremely fast bit instructions • Extremely short response time (terminal <-> terminal)
Communication • PN IO RT/IRT in every CPU • 2 additional interfaces for network separation • All I/O data (PLC, CM) in the process image • Easy communication programming for PLC & CMs • Integrated web server Display • For commissioning • For rapid diagnostics • All error messages in plain text • Access to MLFB, serial number.,... Portfolio • One system for machine and plant engineering • Reduction of modules by >50% with CPU • Reduction of modules by >30% with I/O
Restricted / © Siemens AG 2014. All Rights Reserved. Page 26
I IA AS, R. Kosek
SIMATIC S7-1500 Displej CPU
X1: 192.168.0.1 X2: 192.168.1.1
Start screen
Status
Diagnostics
Fail-safe
Restricted / © Siemens AG 2014. All Rights Reserved. Page 27
I IA AS, R. Kosek
SIMATIC S7-1500 Displej - provedení Displej pro uvád ní do provozu a diagnostiku • Zákl. nastavení/zm ny, nap . IP adresy, název stanic a nepot ebuji servisní PC ( i Filed PG) • Na displeji se zobrazí, pokud chybí nebo nebyl na ten projekt, nebo že je nap . SIMATIC memory card chrán na proti zápisu • Zobrazuje systémovou diagnostiku a uživatelské alarmy • Status jednotek pro central / distributed moduly • MLFB, firmware, sériová ísla central / distributed modul • Vícejazy né menu a texty zpráv (p epínání za provozu) • Volitelné odpojení a p ipojení displeje b hem provozu • Nastavitelná hesla pro uživatele (nastavení p es TIA Portal) • Uživatelské logo na displeji (*.bmp, *.jpg, *.png, *.gif ) • Životnost 50,000 provozních hodin
Restricted / © Siemens AG 2014. All Rights Reserved. Page 28
I IA AS, R. Kosek
SIMATIC S7-1500 Highlights Hardware • Max. 32 modules / line • Identical modules for U-connector and backplane assembly • Sufficient memory for any application • Load memory via SIMATIC memory card
Performance • Extremely fast backplane bus • Extremely fast bit instructions • Extremely short response time (terminal <-> terminal)
STEP7 language innovations • Fully symbolic programming • High-performance LAD/FBD/SCL compiler • Innovations LAD/FBD/SCL • Max. DB: 10MB, FBs/FCs: 512k
Communication • PN IO RT/IRT in every CPU • 2 additional interfaces for network separation • All I/O data (PLC, CM) in the process image • Easy communication programming for PLC & CMs • Integrated web server Display • For commissioning • For rapid diagnostics • All error messages in plain text • Access to MLFB, serial number.,... Portfolio • One system for machine and plant engineering • Reduction of modules by >50% with CPU • Reduction of modules by >30% with I/O
Restricted / © Siemens AG 2014. All Rights Reserved. Page 29
I IA AS, R. Kosek
SIMATIC S7-1500 Programování a práce v prost edí TIA Portal Nové prvky • Pln symbolický p ístup ve všech ástech projektu • Optimalizace kompilátoru všech jazyk LAD/FBD/SCL • Plná ekvivalence a shodný rozsah p íkaz v t chto programovacích jazycích • Compute box pro LAD/FBD na komplexní výpo etní algoritmy • Podpora 64-bit datových typ (LREAL, LINT, LWORD…) u všech IEC jazyk • Žádné omezení velikosti bloku na 64 kByte – FBs/FCs lze do 512 kByte, DBs do 10 Mbyte (system limit je až 16 Mbyte) • Volné p azení názv a vlastní íslování u OB ur itého typu • Implicitní konverze datových typ • Doporu ení pro práci v prost edí TIA Portal a migrace http://support.automation.siemens.com/WW/view/de/81318674
Efektivita, flexibilita a volnost p i programování Restricted / © Siemens AG 2014. All Rights Reserved. Page 30
I IA AS, R. Kosek
SIMATIC S7-1500 Nové možnosti pro download Náhrávání sw a konzistence dat • Konzistentní download – do CPU jsou na teny všechny bloky kterých se zm na týká • Uchování stávajících dat pro download: Rozší ení data bloku, smazání tagu v DBs, zm ny v komentá i – aktuální hodnoty ostatních tag v rámci DB stávají zachovány • Retentivita dat se definuje až na úrove jednotlivých tag v rámci jednotlivých DBs
Aktuální hodnoty v DB již nemusejí být reinicializovány p i každém download in RUN Restricted / © Siemens AG 2014. All Rights Reserved. Page 31
I IA AS, R. Kosek
viz TIAnD 2013/06
STEP 7 inovace FB/DB a zm ny v interface bloku bez ztráty procesních dat +
Rozší ení FB/DB bez ztráty dat
Dodate né zm ny v FB/DB bez rizika: • Lze vytvo it a nahrát do PLC FB/DB s pam ovou rezervou • Aktivovat nahrání bez reinicializace (existující hodnota se pak již nezm ní) • idat nový tag • Dojde k zachování aktuálních hodnot FB/DB i p i nahrání nového rozhraní bloku • Funkce je k dispozici jak pro optimalizované tak pro standard DBs • Výchozí velikost rezervy p i vytvo ení nového DB je 100 bajt . Lze zadat a nastavit pro r zné bloky dle pot eby
Aktivace nahrání bez reinicializace
Number Value_1
Rezerva
Number Rozší ení DB v režimu RUN bez reinicializace
Value_1
Current_Value Reserve Value_2
Restricted / © Siemens AG 2014. All Rights Reserved. Page 32
I IA AS, R. Kosek
STEP 7 inovace FB/DB a zm ny v interface bloku bez ztráty procesních dat
Ukázka, komentá
Restricted / © Siemens AG 2014. All Rights Reserved. Page 33
I IA AS, R. Kosek
STEP 7 inovace FB/DB a zm ny v interface bloku bez ztráty procesních dat
Ukázka, komentá
Restricted / © Siemens AG 2014. All Rights Reserved. Page 34
I IA AS, R. Kosek
STEP 7 inovace Optimalizované a standardní bloky
Ukázka, komentá
Restricted / © Siemens AG 2014. All Rights Reserved. Page 35
I IA AS, R. Kosek
SIMATIC S7-1500 Highlights Hardware • Max. 32 modules / line • Identical modules for U-connector and backplane assembly • Sufficient memory for any application • Load memory via SIMATIC memory card
Performance • Extremely fast backplane bus • Extremely fast bit instructions • Extremely short response time (terminal <-> terminal)
STEP7 language innovations • Fully symbolic programming • High-performance LAD/FBD/SCL compiler • Innovations LAD/FBD/SCL • Max. DB: 10MB, FBs/FCs: 512k System diagnostics, alarms • Fully integrated system diagnostics • One ALARM FB • Uniform representation PLC&HMI
Communication • PN IO RT/IRT in every CPU • 2 additional interfaces for network separation • All I/O data (PLC, CM) in the process image • Easy communication programming for PLC & CMs • Integrated web server
Plug & play • Read-out of actual configuration • Complete project upload to empty programming device
Display • For commissioning • For rapid diagnostics • All error messages in plain text • Access to MLFB, serial number.,... Portfolio • One system for machine and plant engineering • Reduction of modules by >50% with CPU • Reduction of modules by >30% with I/O
Restricted / © Siemens AG 2014. All Rights Reserved. Page 36
I IA AS, R. Kosek
SIMATIC S7-1500 Programování a práce v prost edí TIA Portal Plug & play • Detekce HW pro rychlé a bezchybné na tení aktuální konfigurace hardware • Kompletní upload projektu v etn hardware i software najednou se na te pln konfigurovaná stanice SIMATIC S7-1500 • etn nastavení u centrálních modul • etn nastavení decentrálních modul I/O • (Zatím) bez podpory F-modul (platí pro V13) • hem funkce upload, jsou samozžejm jako již d íve na teny symboly i komentá e
Efektivita p i uvád ní technologie do provozu a servisních innostech díky inovaci upload/download funkcí Restricted / © Siemens AG 2014. All Rights Reserved. Page 37
I IA AS, R. Kosek
SIMATIC S7-1500 new features in TIA Portal V13 Station upload to PG/PC
Ukázka, komentá
Upload of Hardware & Software • Upload of software, comments, symbolic information and hardware for S7-1500: • central modules • distributed periphery • No support of F-modules (in V13)
Restricted / © Siemens AG 2014. All Rights Reserved. Page 38
I IA AS, R. Kosek
SIMATIC STEP 7 in TIA Portal – Compatibility Online – Upload/Download
V13 Engineering Software
V13 Project *
<= V12 SP1 Project (auch STEP 7 Classic)
Restricted / © Siemens AG 2014. All Rights Reserved. Page 39
**
V13 Project
* Nur KOP/FUP/AWL Bausteine **incl. hardware configuration I IA AS, R. Kosek
SIMATIC STEP 7 in TIA Portal – Compatibility Online – Upload/Download
V13 Engineering Software
V12 SP1 project in compatibility mode
V13 Project *
<= V11 Project
V12.0 Project
V12 SP1 Project
V13 Project
*incl. hardware configuration Restricted / © Siemens AG 2014. All Rights Reserved. Page 40
I IA AS, R. Kosek
SIMATIC STEP 7 in TIA Portal – Compatibility Project upgrade and comptability mode
V13 Engineering Software Open in V12 SP1 comptability mode
Projekt upgrade to V12.1
<= V11-Project
V12.0-Project
V12 SP1 Project
V13 Project
Project Upgrade to V13.0 Restricted / © Siemens AG 2014. All Rights Reserved. Page 41
I IA AS, R. Kosek
SIMATIC S7-1500 Highlights: Firmware V1.5 in TIA Portal V13 New CPUs
Focus
Hardware configuration Focus
CPU 1515
Station Upload - complete Hardware and Software Upload all parameters (Standard)
CPU 1518
Fast IP address change Extended functions for handling PROFINET names
New blocks / data types
Shared i-Device
Reflection instructions (GetSym, GetBlockName, GetInstanceName)
Option handling with central modules
Data type WChar/WString JOIN und SPLIT of strings
New features for display / webserver
Status of the CPU load via RT_Info Focus
Integrated Technology Down-sizing of the motion-cycle (servo) to the PROFINET-cycle
Shared PLC Parallel monitoring of block for up to 5 users on the PLC
Additional language support of Russian, Japanese, Portuguese, Turkish, Korean for Display and Webserver Reading access to watch- / force-table at the display and on the webserver User defined logo at the display
Restricted / © Siemens AG 2014. All Rights Reserved. Page 42
I IA AS, R. Kosek
SIMATIC S7-1500 Highlights for CPU 1515 – the PLC in the middle range S7-1515 Highlights Performance Bit performance: 30ns
PN IRT (V2.3) conformity
500kByte program, 3MByte data
two PROFINET interfaces with separate IP-address
Cycle time OB 3x, OB6x: 500µs Connection of up to 20 axes
Two PROFINET-interfaces: Separate IP-address For network separation Simple integration into the customer IT-infrastructure For application in the middle range (~ CPU 315-2 PN/DP)
Communication
IPv6 via CP 1543-1
Security
Usability
Tests of hacker-attacks of ENCS (European Network for Cyber Security) without success
Integrated technology functions: e.g. Motion, Trace, …
VPN und Firewall via CP 1543-1 Security Integrated: Know-How-protec., Binding to SMC, protec. against manipulation
On-site-diagnostic with the multi language display Reading access to force- and watch table directly on the display
Restricted / © Siemens AG 2014. All Rights Reserved. Page 43
I IA AS, R. Kosek
SIMATIC S7-1500 Highlights of CPU 1518 – the most powerful PLC of Siemens S7-1518 Highlights Performance
Communication
Bit, Word, Floating: 1ns, 2ns , 6ns
PN IRT (V2.3) conformity
Clamp-Clamp-reaction: ~160µs
three PROFINET interfaces with separate IP address
Cycle time OB3x, OB6x: 250µs Connection of up to 128 axes
IPv6 via CP 1543-1
Security
Usability
Code performance (based on analyses of 247 projects)
Tests of hacker-attacks of ENCS (European Network for Cyber Security) without success
Integrated technology functions: e.g. Motion, Trace, …
• 8 times faster than CPU 1516
VPN und Firewall via CP 1543-1
• 4 times faster than CPU 319 with use of standard DBs • 10-12 times faster than CPU 319 with use of optimized DBs Working memory: 3MB program, 10MB data
Security Integrated: Know-How-protec., Binding to SMC, protec. against manipulation
On-site-diagnostic with the multi language display Reading access to force- and watch table directly on the display
Restricted / © Siemens AG 2014. All Rights Reserved. Page 44
I IA AS, R. Kosek
SIMATIC S7-1500 novinky v TIA Portal V13 Nové jazyky pro zobrazení na webserver a displej Nové prvky pro displej a webserver • Nové jazyky pro zobrazení na webserver a displej : • Nyní nov : • Ruština, Japonština, Ture tina, Portugalština, Korejština •
tení watch tables a force table p ímo na displeji CPU
Watch table na displeji CPU
New
Restricted / © Siemens AG 2014. All Rights Reserved. Page 45
I IA AS, R. Kosek
SIMATIC S7-1500 novinky v TIA Portal V13 Funkce displeje pro rychlejší a komfortn jší servis, oživování apod Praktické funkce p ímo na displeji CPU
IP adresy CPU
asové pásmo
Popisky
• Na první stránce displeje naleznete vždy IP adresu(y) integrovaných PN rozhaní • Také IP adresy p ipojených komunika ních karet lze nastavovat, m nit p es displej • Popisky a dopl ující informace nap . u Watch tables jsou k dispozici po stisku levého tla ítka displeje
Natavení IP adres také u komunika ních karet CP v rámu
• Lze zm nit nastavení asového pásma pro CPU
Restricted / © Siemens AG 2014. All Rights Reserved. Page 46
I IA AS, R. Kosek
SIMATIC S7-1500 novinky v TIA Portal V13 Nové možnosti pro displej CPU Novinka • Lze na úvodní stránku displeje umístit firemení logo nebo jakýkoliv jiný obrázek: • *.bmp, *.jpg, *.png a *.gif jsou podporované formáty pro takový obrázek • Firemní logo lze automaticky p izp sobit velikosti displeje použitého PLC • Když není v PLC nahrán žádný projekt zobrazuje se ikona, která napoví • Když je PLC chrán no (Memory Card write protect) zobrazuje se ikona, která napoví
Restricted / © Siemens AG 2014. All Rights Reserved. Page 47
I IA AS, R. Kosek
SIMATIC S7-1500 novinky v TIA Portal V13 Paralelní monitoring S7-1500
• S7-1500 od firmware V1.5 umož uje až 5-ti uživatel m monitorovat r zné bloky sou asn na jednom CPU • TIA Portal pak automaticky informuje uživatele o programových zm nách (které provedli ostatní uživatelé).
Pokra ování zde… viz Team Engineering Restricted / © Siemens AG 2014. All Rights Reserved. Page 48
I IA AS, R. Kosek
SIMATIC S7-1500 novinky Jak efektivn programovat v prost edí TIA Portal Programujte správn v prost edí TIA Portal • Doporu ení jak pracovat v novém prost edí TIA Portal s PLC S7-1200/S7-1500 > Guideline in Customer Support • Odkazy na d ležité dokumenty a informace týkající se migrace • • • •
Guideline FAQs Videa …
Restricted / © Siemens AG 2014. All Rights Reserved. Page 49
I IA AS, R. Kosek
SIMATIC S7-1500 novinky Instructions list ehled instrukcí v ídicích systémech SIMATIC S7 •
Instrukce pro všechny S7-CPU S7-300/400/1200/1500
•
Porovnání všech program. jazyk (LAD, FBD, STL, SCL)
•
Zvýrazn né nové instrukce
•
Doporu ení pro použití nebo naopak restrikce
•
Rozd lení do sekcí • Basic instrukce • Extended instrukce • Technology • Communication
•
Ke stažení zde: Service&Support
Restricted / © Siemens AG 2014. All Rights Reserved. Page 50
I IA AS, R. Kosek
SIMATIC S7-1500 Highlights Hardware • Max. 32 modules / line • Identical modules for U-connector and backplane assembly • Sufficient memory for any application • Load memory via SIMATIC memory card
Performance • Extremely fast backplane bus • Extremely fast bit instructions • Extremely short response time (terminal <-> terminal)
System diagnostics, alarms • Fully integrated system diagnostics • One ALARM FB • Uniform representation PLC&HMI
Communication • PN IO RT/IRT in every CPU • 2 additional interfaces for network separation • All I/O data (PLC, CM) in the process image • Easy communication programming for PLC & CMs • Integrated web server Display • For commissioning • For rapid diagnostics • All error messages in plain text • Access to MLFB, serial number.,... Technology • Standard motion (via PN IRT V2.2) • Trace for all tags • New PID control functions
STEP7 language innovations • Fully symbolic programming • High-performance LAD/FBD/SCL compiler • Innovations LAD/FBD/SCL • Max. DB: 10MB, FBs/FCs: 512k
Plug & play • Read-out of actual configuration • Complete project upload to empty programming device Data log (archives) and recipes • On the SIMATIC memory card in csv format • Access via web server
Security integrated Portfolio • One system for machine and plant engineering • Reduction of modules by >50% with CPU • Reduction of modules by >30% with I/O
compatibility • Within the complete product range • Easy migration 300/400->1500 Security integrated • Know-how protection / copy protection • Authentication • Manipulation protection
Restricted / © Siemens AG 2014. All Rights Reserved. Page 51
I IA AS, R. Kosek
kuji za pozornost! Rostislav Kosek Industry Sector IA AS Siemensova 1 155 00 Praha 13 E-Mail:
[email protected]
Siemens offers automation and drive products with industrial security functions which support safe system or machine operation. They essentially contribute to the realization of a holistic industrial security concept. Our products are continuously advanced under this aspect. We therefore recommend you to regularly inform yourself on updates of our products and to only use the respectively current versions. Relevant information is available at: http://support.automation.siemens.com. You can also subscribe to a product-specific newsletter via this link. Moreover, safe system or machine operation necessitates the implementation of suitable protective measures (e.g. cell protection concept) and the integration of all automation and drive components in a holistic state-of-the-art industrial security concept for the entire system or machine. Also third-party products have to be taken into account in this context. Further information is available at: http://www.siemens.com/industrialsecurity
Restricted / © Siemens AG 2014. All Rights Reserved. Page 52
I IA AS, R. Kosek
Diskuze… Technická podpora:
eská republika http://www.siemens.cz/iadt-kontakt
[email protected] Tel.: 800 122 552
Celosv tov (n mecky/anglicky)
[email protected] http://support.automation.siemens.com Tel.: +49 180 5050 222 Restricted / © Siemens AG 2014. All Rights Reserved. Page 53
I IA AS, R. Kosek