LEMBAR DATA KESELAMATAN ________________________________________________________________________________________________________________
BAGIAN 1: Identifikasi zat/campuran dan perusahaan/usaha Identifikasi zat atau campuran Kode Produk Nama Produk
P33311 Pro-Q® Diamond phosphoprotein gel destaining solution
Identifikasi perusahaan/usaha Life Technologies 5791 Van Allen Way PO Box 6482 Carlsbad, CA 92008 +1 760 603 7200 12FL Suseo Office Building 281 Gwangpyeong-ro, Gangnam-gu Seoul, 135-884, Korea T 82.2.2023.0600 Guangzhou Office Room1010-1013 South Tower Guangzhou World Trade Center Complex 371-376 HuanShi Dong Rd Guangzhou 510095, China Tel: +86-020-8760 9229 Hotline: 800 830 2001 Fax: +86-020-8775 0687
24 hour Emergency Response:
Life Technologies New Zealand Limited 18 - 24 Botha Road Penrose Auckland 1061 NEW ZEALAND +64 9 579 3024 0800 636 327 Life Technologies Australia Pty Limited 30-32 Compark Circuit Mulgrave VIC 3170 AUSTRALIA +61 3 9262 3700 1800 636 327 Silver Tower-Beijing Office Room 1711 Beijing Silver Tower #2 DongSanHuan North Rd, Beijing 100027 P.R.China Tel: +86-010-8446 1800 Fax: +86-010-6410 6617
1800 636 327 (Australia) 0800 636 327 (New Zealand) 866-536-0631 (US) 301-431-8585 (US) ++1-301-431-8585 (Outside of the U.S.)
For Veterinary Use only.
________________________________________________________________________________________________________________ Tanggal revisi Kode Produk
30-Oct-2014 P33311
Halaman 1 / 7 Nama Produk Pro-Q® Diamond phosphoprotein gel destaining solution www.lifetechnologies.com
Australian MSDS Statement
BAGIAN 2: Identifikasi bahaya Diklasifikasikan berdasarkan kriteria Keselamatan Kerja Australia. Zat yang Berbahaya. Barang-barang yang Tidak-Berbahaya.
GHS - Klasifikasi Kata Sinyal BAHAYA
Bahaya Kesehatan Korosi/iritasi kulit Toksisitas reproduktif
Kategori 3 Kategori 1B
Bahaya Fisik Tidak Berbahaya
pernyataan berbahaya H316 - Menyebabkan iritasi kulit ringan H360 - Bisa merusak kesuburan atau janin bila terhirup
pernyataan tindakan pencegahan P305 + P351 + P338 - JIKA TERKENA MATA: Bilas secara hati-hati dengan air selama beberapa menit. Lepas lensa kontak, jika ada dan mudah melepaskannya. Teruskan membilas P302 + P352 - JIKA TERKENA KULIT: Cuci dengan sabun dan air yang banyak P308 + P313 - JIKA terpapar atau khawatir: Dapatkan saran/ pertolongan medis P312 - Hubungi PUSAT INFORMASI RACUN atau dokter jika merasa tidak enak badan P280 - Kenakan sarung tangan pelindung/pakaian pelindung/pelindung mata/pelindung wajah P202 - Jangan pegang sebelum membaca dan memahami semua tindakan pencegahan keselamatan P201 - Mintalah petunjuk khusus sebelum menggunakan
Uni Eropa
Pernyataan Bahaya Spesifik UE
________________________________________________________________________________________________________________ Tanggal revisi Kode Produk
30-Oct-2014 P33311
Halaman 2 / 7 Nama Produk Pro-Q® Diamond phosphoprotein gel destaining solution www.lifetechnologies.com
R -phrase(s) R60 - Bisa mengganggu kesuburan R61 - Bisa membahayakan janin R36/37/38 - Mengiritasi mata, sistem pernapasan dan kulit Frasa S S26 - Jika kontak dengan mata, segera bilas dengan air yang banyak dan minta saran medis S24/25 - Hindari kontak dengan kulit dan mata S36/37/39 - Kenakan pakaian pelindung, sarung tangan dan pelindung mata/wajah yang sesuai Principle Routes of Exposure Potential Health Effects MATA Kulit Penghirupan PENELANAN
Mengiritasi mata. Mengiritasi kulit. Mengiritasi sistem pernapasan. BISA BERBAHAYA BILA TERTELAN. Penelanan bisa menyebabkan iritasi gastrointestinal, mual, muntah, dan diare.
Efek spesifik Efek karsinogenik EFEK MUTAGENIK Toksisitas reproduktif Sensitisasi
Tidak ada Tidak ada Bisa mengganggu kesuburan Bisa membahayakan janin Tidak ada Tidak satu pun dalam kondisi penggunaan normal
Efek pada organ target
BAGIAN 3: Komposisi/informasi bahan baku Nama kimia
CAS-No 872-50-4
1-Methyl-2-pyrrolidone
EINECS-No 212-828-1
Weight % 7-13
Kami merekomendasikan penanganan semua bahan kimia dengan hati-hati.
BAGIAN 4: Tindakan pertolongan pertama Segera cuci dengan air yang banyak selama setidaknya 15 menit. Tanggalkan semua pakaian yang terkontaminasi dan cuci sebelum digunakan kembali. Pertolongan medis segera diperlukan. Segera bilas dengan air yang banyak, juga di bawah kelopak mata, selama setidaknya 15 menit. Pertolongan medis segera diperlukan. Segera hubungi dokter atau pusat pengendalian racun. Jangan memberikan apa pun melalui mulut kepada orang yang pingsan. Jangan rangsang muntah tanpa saran medis. Pindahkan ke udara segar. Jika tidak bernapas, berikan pernapasan buatan. Segera hubungi dokter atau pusat pengendalian racun. Rawat sesuai gejalanya.
Kontak dengan kulit
Kontak dengan mata PENELANAN
Penghirupan Catatan bagi Dokter
BAGIAN 5: Tindakan pemadaman kebakaran Media Pemadaman yang Sesuai
Semprotan air. Karbon dioksida (CO2). Busa. Bahan kimia kering.
________________________________________________________________________________________________________________ Tanggal revisi Kode Produk
30-Oct-2014 P33311
Halaman 3 / 7 Nama Produk Pro-Q® Diamond phosphoprotein gel destaining solution www.lifetechnologies.com
Peralatan pelindung khusus bagi pemadam kebakaran Kenakan alat bantu pernapasan mandiri (SCBA) dan setelan pelindung. BAGIAN 6: Tindakan terhadap pelepasan tak sengaja Tindakan pencegahan pribadi Metode pembersihan
Pastikan ventilasi mencukupi. Hindari kontak dengan kulit, mata atau pakaian. Gunakan alat pelindung diri. Serap dengan bahan penyerap yang lembam.
Tindakan Pencegahan Dampak Lingkungan Cegah kebocoran atau tumpahan lebih lanjut jika aman dilakukan. Cegah produk memasuki saluran pembuangan. Lihat Bagian 12 untuk informasi selengkapnya. BAGIAN 7: Penanganan dan penyimpanan Selalu gunakan Peralatan Perlindungan Diri yang direkomendasikan. Tidak diperlukan nasihat penanganan khusus. Simpan di tempat kering, dingin, dan berventilasi baik. Simpan dalam wadah dengan label yang benar.
Penanganan Penyimpanan
BAGIAN 8: Pengendalian paparan/perlindungan diri Batas Paparan
Nama kimia 1-Methyl-2-pyrrolidone 872-50-4
Australia STEL 75 ppm 309 mg/m3
Australia OEL 25 ppm 103 mg/m3
Australia - Skin Absorbers Skin
Australia - OES - Peak Tidak ada
Nama kimia
New Zealand - Workplace Exposure Limits skin notation
New Zealand TWA
New Zealand STEL
Tidak ada
Tidak ada
New Zealand Ceiling Limits Tidak ada
Nama kimia 1-Methyl-2-pyrrolidone 872-50-4
China OEL Tidak ada
Cina - Penyerap Kulit Tidak ada
Hong Kong OEL Tidak ada
Nama kimia 1-Methyl-2-pyrrolidone 872-50-4
Korea OEL (CEILING) Tidak ada
Korea OEL (TWA) Tidak ada
Korea OEL (STEL) Tidak ada
Nama kimia 1-Methyl-2-pyrrolidone 872-50-4
Taiwan OEL (TWA) Tidak ada
Taiwan OEL Tidak ada
Taiwan Ceiling Limits Tidak ada
1-Methyl-2-pyrrolidone 872-50-4
Nama kimia 1-Methyl-2-pyrrolidone 872-50-4
Engineering measures
Singapore OEL (PEL) Tidak ada
Singapore OEL (STEL) Tidak ada
Pastikan ventilasi yang cukup, khususnya di area tertutup.
Alat pelindung diri Personal Protective Equipment requirements are dependent on the user institution's risk assessment and are specific to the risk assessment for each laboratory where this material may be used. ________________________________________________________________________________________________________________ Tanggal revisi Kode Produk
30-Oct-2014 P33311
Halaman 4 / 7 Nama Produk Pro-Q® Diamond phosphoprotein gel destaining solution www.lifetechnologies.com
Perlindungan pernapasan
Jika ventilasi tidak memadai, kenakan peralatan pernapasan yang sesuai.
Sarung tangan yang kedap. Perlindungan Tangan Kacamata keselamatan dengan pelindung-samping. Perlindungan Mata Perlindungan kulit dan tubuh Pakaian pelindung yang ringan. Tangani sesuai praktik higiene dan keselamatan yang baik. Hygiene measures Pengendalian paparan lingkungan
Cegah produk memasuki saluran pembuangan. Jangan biarkan bahan mencemari sistem air tanah. BAGIAN 9: Sifat fisika dan kimia
Informasi umum Form penampakan Bau Titik didih / rentang didih Titik leleh/rentang leleh Titik Nyala Suhu penyulutan otomatis Sifat pengoksidasi Kelarutan air
liquid Tidak ada informasi yang tersedia Tidak ada informasi yang tersedia °C data tidak tersedia °C data tidak tersedia °C data tidak tersedia °C data tidak tersedia Tidak ada informasi yang tersedia soluble
°F °F °F °F
data tidak tersedia data tidak tersedia data tidak tersedia data tidak tersedia
BAGIAN 10: Stabilitas dan reaktivitas stabilitas Bahan yang harus dihindari Produk Dekomposisi yang Berbahaya Polimerisasi
Stabil dalam kondisi normal. Tidak ada informasi yang tersedia. Tidak ada informasi yang tersedia. Tak satu pun dalam pemrosesan normal.
________________________________________________________________________________________________________________ Tanggal revisi Kode Produk
30-Oct-2014 P33311
Halaman 5 / 7 Nama Produk Pro-Q® Diamond phosphoprotein gel destaining solution www.lifetechnologies.com
BAGIAN 11: Informasi toksikologis
Toksisitas akut Nama kimia 1-Methyl-2-pyrrolidone
LD50 (oral,tikus/mencit) = 3598 mg/kg (Rat)
Principle Routes of Exposure Potential Health Effects MATA Kulit Penghirupan PENELANAN
LD50 (dermis,tikus/kelinci) data tidak tersedia
LC50 (inhalation,rat/mouse) =3.1mg/L(Rat)
Mengiritasi mata. Mengiritasi kulit. Mengiritasi sistem pernapasan. BISA BERBAHAYA BILA TERTELAN. Penelanan bisa menyebabkan iritasi gastrointestinal, mual, muntah, dan diare.
Efek karsinogenik EFEK MUTAGENIK Toksisitas reproduktif Sensitisasi
Tidak ada. Tidak ada. Bisa mengganggu kesuburan. Bisa membahayakan janin. Tidak ada.
Efek pada organ target
Tidak satu pun dalam kondisi penggunaan normal BAGIAN 12: Informasi ekologis Daphnia magna lihat log Pow Tidak ada informasi yang tersedia Tidak ada informasi yang tersedia
ekotoksisitas Mobilitas biodegradasi Bioakumulasi Nama kimia 1-Methyl-2-pyrrolidone
Freshwater Algae Data Desmodesmus subspicatus EC50>500 mg/L (72 h)
Water Flea Data
Freshwater Fish Species Data
Microtox Data
Daphnia magna EC50=4897 mg/L (48 h)
log Pow logPow-0.46
BAGIAN 13: Pertimbangan pembuangan Buang isi/kontainer sesuai peraturan setempat. BAGIAN 14: Informasi transportasi
IATA Nama Pengiriman yang Benar Kelas Bahaya Kelas tambahan Kelompok Kemasan No. UN
Tidak diklasifikasikan berbahaya menurut peraturan pengangkutan. Tidak ada Tidak ada Tidak ada none
________________________________________________________________________________________________________________ Tanggal revisi Kode Produk
30-Oct-2014 P33311
Halaman 6 / 7 Nama Produk Pro-Q® Diamond phosphoprotein gel destaining solution www.lifetechnologies.com
BAGIAN 15: Informasi terkait peraturan Inventarisasi Internasional Mematuhi Nama kimia 1-Methyl-2-pyrrolidone
EINECS Listed
ELINCS -
ENCS Listed
PICCS Listed
TSCA Listed
Nama kimia 1-Methyl-2-pyrrolidone
Cina Listed
AICS Listed
KECL Listed
DSL Listed
NDSL -
Korea This product complies with applicable Korean chemical regulations. Nama kimia
Industrial Safety and Health Act (ISHA)
Toxic Chemicals Control Act (TCCA)
Wastes Control Act
1-Methyl-2-pyrrolidone
Tidak Terdaftar
Tidak Terdaftar
Tidak Terdaftar
National Emergency Management Agency (NEMA) - Dangerous Substances Tidak Terdaftar
BAGIAN 16: Informasi lainnya
Bagian (M)SDS (Material Safety Data Sheet/Lembar Data Keselamatan Bahan) telah diperbarui
Alasan revisi
For Veterinary Use only.
Informasi di atas diperoleh melalui penelusuran dan/atau investigasi dan rekomendasi berdasarkan aplikasi bijak pada pertimbangan profesional. Informasi tidak boleh diambil secara inklusif dan hanya digunakan sebagai petunjuk. Semua bahan dan campuran mungkin diketahui tidak berbahaya dan sebaiknya digunakan dengan hati-hati. Karena Perusahaan tidak dapat mengontrol metode, volume, atau kondisi aktual penggunaan, Perusahaan tidak bertanggung jawab atas bahaya atau kehilangan yang disebabkan dari penanganan atau dari kontak dengan produk sebagaimana disebutkan di sini. INFORMASI DALAM SDS INI BUKAN MERUPAKAN JAMINAN, TERSURAT ATAU TERSIRAT, TERMASUK JAMINAN PERDAGANGAN YANG TERSIRAT ATAU KESESUAIAN UNTUK TUJUAN TERTENTU Akhir dari Lembar Data Keselamatan
________________________________________________________________________________________________________________ Tanggal revisi Kode Produk
30-Oct-2014 P33311
Halaman 7 / 7 Nama Produk Pro-Q® Diamond phosphoprotein gel destaining solution www.lifetechnologies.com