E!3483
EULASNET LASCAN
Advanced laser renovation of old paintings, paper, parchment and metal objects. UNIVERSITIES, ACADEMIES
5
RESEARCH CENTRES, INSTITUTES
5
SMEs
8
END USERS
2
E!3483
EULASNET LASCAN
Advanced laser renovation of old paintings, paper, parchment and metal objects. UNIVERSITIES, ACADEMIES
5
RESEARCH CENTRES, INSTITUTES
2
SMEs
2
END USERS
2
E!3483
EULASNET LASCAN
AIMS AND OBJECTIVES: Development and implementation of new, advanced laser cleaning systems, automatic systems of scanning (objects, laser beam)
sensors for automatic detection of distance to the surface with the system of “dynamic focusing” or dynamic laser fluency control for irregular surfaces
E!3483
EULASNET LASCAN
AIMS AND OBJECTIVES:
Optimization of complementary renovation techniques, evaluation of the results based on the experience of consortium partners Creation of data bases or supplements to the existing ones (objects, procedures).
E!3483
EULASNET LASCAN
DPSS Nd:YAG LASER Pulse energy: 3.0 mJ @ 1064 nm; 1.3 mJ @ 532 nm 0.9 mJ @ 355 nm 0.6 mJ @ 266 nm Pulse energy stability: 1.0 % @ 1064 nm (St.Dev); 4.0 % @ 266 nm (St.Dev) Pulse duration stability: < 1 % @ 1064 nm (StDev). Repetition rate: 1000 Hz. Pulse duration: < 70 ps (30 ps) Spatial mode: TEM00 Beam diameter: ~ 3 mm. Beam divergence (full angle at 1/e2): < 1.6 mrad. Polarization purity (vertical): > 100:1. Contrast ratio (to residual pulse): > 200:1.
E!3483
EULASNET LASCAN
DPSS Nd:YAG LASER SECOND HARMONIC GENERATOR - KTP crystal in temperature-controlled heater. - Harmonics separator. THIRD HARMONIC GENERATOR - LBO crystal in temperature-controlled heater. - Harmonics separator. FOURTH HARMONIC GENERATOR - LBO crystal in temperature-controlled heater. - Harmonics separator.
E!3483
EULASNET LASCAN
LASER SCANNING SYSTEM
Lézerek alkalmazása a festmény restaurálásban - Magyarországon A Déri projekt: • 2006 február 1- 2007 szeptember 15 • Pécsi Tudományegyetem • Pannon Egyetem • Szépművészeti Múzeum • Magyar Restaurátorok Egyesülete • Mikroanyag Kft. • Támogatás: 63 MFt saját forrás 21 MFt
E!3483 EULASNET LASCAN
HUNGARY PANNONLASER, University Pecs
Excimer laser laboratory •KrF excimer laser (248 nm) •Controlled fluence and energy distribution •XY Z! scanning over ~1m2 •Andor Mechelle spectrograph •iStar camera •Exhaust hood, microscopes…
3D scanning system (University of Veszprem)
E!3483
EULASNET LASCAN
LASER CLEANING STATION
PANNONLASER
A kiválasztott teszt-képek
•a Szépművészeti Múzeum selejtraktárából származnak •fizikai felépítésük, állapotuk, anyagi összetevőik különbözők, hogy minél több romlási típust, öregedési folyamatot tudjunk rajtuk elkülöníteni Leltári szám
Szerző
Cím
Technika
Méret [cm]
840
Cranach után
Madonna
olaj-fém
25,3 x 20,6
6339
Magnasco után
Várromok hegyen
olaj-vászon
59 x 45,5
65.2
Német, 18. sz.
Párducot marcangoló kutyák
olaj-vászon
59 x 73
1378
Német, 18. sz.
Kikötő
olaj-fa
33 x 44,3
52.673
Teniers után, 19.sz.
Hegedülő paraszt
olaj-fa
25,7x 36,7
E!3483 EULASNET LASCAN
HUNGARY PANNONLASER, University Pecs
Place of sampling after laser treatment (248nm, 184mJ/cm2, 20 pulses) Stratigraphy Before laser treatment
After laser treatment 1–overpainting 2–varnish 3–pigment layer 4–primer
Átfestés eltávolítása ~15mm
Az átfestés eltávolítása után a lakkréteg elvékonyítása
Átfestés eltávolítása a lakk felszínéről
~25mm
A lézeres lakkeltávolítást befolyásoló tényezők •Raszter kialakulása sík felszín és vastag lakkréteg esetén
•Hamisított repedésháló vonalainak mélyülése, kiszélesedése
a) 248 nm-es lézerimpulzusokkal tisztított terület az 52,673 leltári számú képen (energiasűrűség 750 mJ/cm2), bekarcolt repedés b) lézeres tisztítás után, c) beavatkozás előtt
•Gyenge szerkezetű képen festék kipergés a lézer mechanikai hatása miatt
KrF lézerrel tisztított terület a 65.2 leltári számú képen. (Energiasűrűség 800 mJ/cm2, átfedés a pásztázó impulzusok közt x irány: 80%, y: 75%)
HUNGARY
E!3483 EULASNET LASCAN
PANNONLASER, University Pecs
Varnish removal @ 248 nm
1 – undercleaned with acetone 2 – overcleaned with dimethyl-formamide
Laser cleaning, 320 mJ/cm2
E!3483 EULASNET LASCAN
Setup for cleaning frescoe fragments @248 nm
HUNGARY PANNONLASER, University Pecs
E!3483 EULASNET LASCAN
HUNGARY PANNONLASER, University Pecs
LASER CLEANING OF FRESCOES
Excavated fresco fragment from Roman age Pannonia, covered by thick encrustation, consolidated with acrylic dispersion, cleaned with KrF laser
E!3483 EULASNET LASCAN
HUNGARY PANNONLASER, University Pecs
Excavated roman frescoe fragments from ancient Sophianae (now Pécs, Hungary) before and after cleaning at 248 nm, 2 J/cm2. As microphotography shows, the egiptian blue pigment and the microstructure of the surface remained intact in the course of cleaning.
E!3483 EULASNET LASCAN
HUNGARY PANNONLASER, University Pecs
The LIBS setup
Spektrumvonalak azonosítása Zn csúcsok a világoskék festékben
Zn Intenzitás (rel. egys.)
Zn
250
300
350
400
450
500
Hullámhossz (nm) 6339 (várrom) világoskék 16 lövés 840 (madonna) piros 5 lövés 65.2 (kutyás) 40 lövés
Hg csúcsok a piros festékben
Intenzitás (rel. egys.)
Hg
250
300
350
400
450
Hullámhossz (nm) 65.2 (kutyás) barna 40 lövés 1378 (kikötő) világoskék 20 lövés 840 (madonna) piros 5 lövés 840 (madonna) piros 4 lövés
E!3483 EULASNET LASCAN
HUNGARY PANNONLASER, University Pecs
PCA score plot of 20 pigment samples shows clustering according to pigment types
E!3483
EULASNET LASCAN
PAINTINGS – LIBS RESULTS
PANNONLASER
Multispektrális kamera
E!3483
EULASNET LASCAN LASER CLEANING – MODERN ART
PANNONLASER
E!3483
EULASNET LASCAN
LASER CLEANING – ARTIFICAL DUST FROM PAPER
SLOVENIA
E!3483
EULASNET LASCAN
Corroded brass covered with nc-lacquer TEA CO2 laser – 5J/cm2 (one pulse)
E!3483
EULASNET LASCAN
Copper with patina
TEA CO2 laser - 4J/cm2 (5 pulses)
E!3483
EULASNET LASCAN
Copperplate engraving at paper. Nd:YAG laser (SHG – 532 nm) Upper ellipse shows squares for different laser fluences Lower circle shows cleaning area around „E”
E!3483
EULASNET LASCAN
Laser cleaning of original old parchment. Nd:YAG laser. Left side (white arrow) – partially cleaned area.
E!3483
EULASNET LASCAN
Tests of laser cleaning of parchment. Nd:YAG laser (SHG – 532 nm) Left side – „square” tests Right side – uncovery of unvisible earlier letters under old encrustation
INPUT CONDITIONS “ONLINE” CONTROL
OBJECTS
AFTER RENOVATION ARCHIVES
LITERATURE DATA
ENCRUSTATION
MATERIALS
PATINAS ORIGINAL SUBSTRATES
OWN RESEARCH RESULTS
DATA BASE
TECHNOLOGIES
CLEANING CONSERVATION INFLUENCE ON OBJECTS
DIAGNOSTICS EXCHANGE INSIDE CONSORTIUM
CLEANING SAFETY DAMAGE THRESHOLD OPTICAL PARAMETERS
ENVIRONMENT
ABLATION THRESHOLD OPTICAL CHANGES CHEMICAL CHANGES ...
CHEMICAL COMPOSITION STRUCTURE ...
E!3483
EULASNET LASCAN
JOINT POLISH-HUNGARIAN DATA BASE
Összefoglalás
Sikeres tisztítást végeztünk KrF lézerrel
Felhívtuk a figyelmet a lézeres tisztítást akadályozó/kizáró tényezőkre
Teszteltük az on-line LIBS-kontroll lehetőségét
Mélységi elemanalízist végeztünk LIBS segítségével
A továbblépés lehetőségei
Pásztázás módosítása a raszter kiküszöbölésére
On-line kontroll fejlesztése fluoreszcencia spektrumokra alapozva
Mélységi LIBS analízisre szolgáló etalonok (pigment, kötőanyag) felvétele
Thank you very much for your attention.