1
Lid NLingenieurs ISO-9001 gecertificeerd
Rapport First te Rotterdam: (karakteristieke) geluidwering van de uitwendige scheidingsconstructie
Rapportnummer G 16598-22-RA d.d. 30 november 2011
Peutz bv Paletsingel 2, Postbus 696 2700 AR Zoetermeer Tel. (079) 347 03 47 Fax (079) 361 49 85
[email protected] Lindenlaan 41, Molenhoek Postbus 66, 6585 ZH Mook Tel. (024) 357 07 07 Fax (024) 358 51 50
[email protected] L. Springerlaan 37 Postbus 7, 9700 AA Groningen Tel. (050) 520 44 88 Fax (050) 526 31 78
[email protected] Montageweg 5 6045 JA Roermond Tel. (0475) 324 333
[email protected] www.peutz.nl Peutz GmbH Düsseldorf, Dortmund, Berlijn
[email protected] www.peutz.de Peutz SARL Paris, Lyon
[email protected] www.peutz.fr Peutz bv London
[email protected] www.peutz.co.uk Daidalos Peutz bvba Leuven
[email protected] www.daidalospeutz.be
Opdrachtgever:
Maarsengroep
Rapportnummer:
G 16598-22-RA
Datum:
30 november 2011
Ref.:
DdB/MJa/DB/G 16598-22-RA
Peutz Sevilla
[email protected] www.peutz.es Köhler Peutz Geveltechniek bv Zoetermeer
[email protected] www.gevel.com Opdrachten worden aanvaard en uitgevoerd volgens De Nieuwe Regeling 2011
BTW identificatienummer NL004933837B01 KvK: 12028033
Inhoud
pagina
1. INLEIDING
3
2. (KARAKTERISTIEKE) GELUIDWERING GEVELS 2.1. Normstelling en uitgangspunten 2.1.1. Geluidbelasting vanwege wegverkeer 2.1.2. Karakteristieke geluidwering van de gevel 2.1.3. Planopzet 2.2. Berekeningen
4 4 4 4 4 5
3. CONCLUSIE
8
G 16598-22-RA
2
1. INLEIDING In opdracht van de Maarsengroep is een akoestisch onderzoek verricht naar de karakteristieke geluidwering van de gevels van het kantoorgebouw First te Rotterdam. Het onderzoek is verricht met het doel om te kunnen beoordelen of met de thans geprojecteerde planopzet van de gevels wordt voldaan aan de in het Bouwbesluit gestelde eisen, danwel welke additionele geluidwerende voorzieningen dienen te worden aangebracht teneinde te kunnen voldoen aan de deze eisen. Bij de beoordeling is gebruik gemaakt van de tekeningen d.d. 30 november 2011 behorende tot werknummer 10007 vam de Architecten Cie.
G 16598-22-RA
3
2. (KARAKTERISTIEKE) GELUIDWERING GEVELS
2.1. Normstelling en uitgangspunten
2.1.1. Geluidbelasting vanwege wegverkeer Teneinde de (karakteristieke) geluidwering van de gevels van First te kunnen bepalen dienen de geluidbelastingen bekend te zijn. Voor de maximale geluidbelasting (L den), exclusief aftrek conform artikel 110g van de Wet geluidhinder is uitgegaan van het 'Overzicht rekenpunten MER Weenapoint mei 2010'. Het betreft de verwachte geluidbelastingen voor het jaar 2021. 2.1.2. Karakteristieke geluidwering van de gevel Voor wat betreft de karakteristieke geluidwering van de uitwendige scheidingsconstructie dient voldaan te worden aan de eisen volgens het Bouwbesluit. Voor kantoren eist het bouwbesluit dat de karakteristieke geluidwering van de uitwendige scheidingsconstructie (GA;k) voor het verblijfsgebied, bepaald volgens NEN 5077, uitgave augustus 2001, minimaal dient te voldoen aan: GA;k ≥ geluidbelasting Lden – 40 dB; met een minimum van 20 dB(A) 2.1.3. Planopzet Voor wat betreft de planopzet is uitgegaan van de tekeningen zoals genoemd in hoofdstuk 1. Gevelbasis Voor wat betreft de visueel gesloten geveldelen is uitgegaan van de volgende opbouw: Buitengevel - beton, 100 mm - isolatie, variërend in dikte - beton, 100 mm totale massa ca. 400 kg/m2, waarvoor geldt RA, wegverkeer = 51 dB(A). Beglazing Voor wat betreft de beglazing in de ramen is uitgegaan van een thermisch isolerende beglazing. De RA,wegverkeer van de beglazing is bepaald opdat aan de eis uit het Bouwbesluit wordt voldaan. De in tabel 1 tot en met 3 aangegeven geluidisolaties R A,wegverkeer voor het glas zijn de in de praktijk te realiseren geluidisolaties. De laboratorium
G 16598-22-RA
4
geluidisolatiewaarde van het het uiteindelijk te plaatsen glas dient 2 dB(A) hoger te zijn dan de genoemde waarden in de tabellen. Vanaf een geluidwering (RA,wegverkeer) van de beglazing van 35 dB(A) is de geluidwering van het kozijn tevens van invloed op de totale karakteristieke geluidwering. In de berekeningen is uitgegaan van een kozijn welke minimaal dezelfde geluidisolatiewaarde heeft als de beglazing. Naden en kieren Ter plaatse van de kantoren en vergaderruimten zijn geen te openen ramen aanwezig. De naden tussen de gevelelementen onderling, zoals tussen kozijnen en gevelbasis, dienen zorgvuldig rondom afgedicht te worden. Ventilatievoorzieningen Het kantoorgebouw First ventilatiesysteem.
wordt
voorzien
van
een
mechanisch
gebalanceerd
2.2. Berekeningen Omdat de toekomstige huurders zwaardere eisen stellen aan de geluidisolatie van de gevel dan gesteld in het Bouwbesluit, is in het ontwerp voorzien in goed geluidisolerende beglazing. In de tabellen 1 tot en met 3 is per gevel de vereiste GA;k weergegeven en welke isolatiewaarden aan beglazing is voorzien. Enkel de kantoorlagen zijn beoordeeld. De nummering van de gevels is terug te vinden in de figuren van bijlage I. Tabel 1: Benodigde (karakteristieke) geluidwering First te Rotterdam (Plint, laag 2 tot en met 7)
bouwlaag
gevelnr.
geluidbelasting [dB] (conform MER)
Bouwlaag 2 tot en met 7
1 2 3.1 3.2 4
70 65 max 51 55 66
G 16598-22-RA
Geluidisolatie RAv glas in dB(A) RAv = 39 dB(A) RAv = 34 dB(A) RAv = 28 dB(A) RAv = 28 dB(A) RAv = 35 dB(A)
Gak benodigd [dB(A)] 30 25 20 20 26
5
Tabel 2: Benodigde (karakteristieke) geluidwering First te Rotterdam (Midrise, laag 8 tot en met 20)
bouwlaag
bouwlaag 8
bouwlaag 9 tot en met 14
bouwlaag 15 tot en met 18
G 16598-22-RA
gevelnr. 1 2 3 4 5 6 7 8 8 9 10 11 12 1 2 3 4 5 6 7 8 8 9 10 11 12 1 2 4 5 6 7 8 9 10 11 12
geluidbelasting [dB] (conform MER) 69 65 65 65 65 65 51 62 62 62 62 55 65 68 64 64 64 64 64 51 62 62 62 62 55 65 67 63 63 63 63 51 61 61 61 55 64
Geluidisolatie RAv glas in dB(A) RAv = 39 dB(A) RAv = 28 dB(A) RAv = 28 dB(A) RAv = 28 dB(A) RAv = 30 dB(A) RAv = 30 dB(A) RAv = 28 dB(A) RAv = 32 dB(A) RAv = 35 dB(A) RAv = 35 dB(A) RAv = 33 dB(A) RAv = 28 dB(A) RAv = 35 dB(A) RAv = 37 dB(A) RAv = 33 dB(A) RAv = 33 dB(A) RAv = 33 dB(A) RAv = 35dB(A) RAv = 30 dB(A) RAv = 28 dB(A) RAv = 28 dB(A) RAv = 31 dB(A) RAv = 31 dB(A) RAv = 32 dB(A) RAv = 28 dB(A) RAv = 32 dB(A) RAv = 36 dB(A) RAv = 33 dB(A) RAv = 32 dB(A) RAv = 34 dB(A) RAv = 29 dB(A) RAv = 28 dB(A) RAv = 30 dB(A) RAv = 30 dB(A) RAv = 30 dB(A) RAv = 28 dB(A) RAv = 31 dB(A)
Gak benodigd [dB(A)] 29 25 25 25 25 25 20 22 22 22 22 20 25 28 24 24 24 24 24 20 22 22 23 22 20 25 27 23 23 23 23 20 21 21 21 20 24
6
bouwlaag 19
bouwlaag 20
G 16598-22-RA
1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12
67 63 55 55 63 63 51 61 61 61 55 64 67 63 55 55 63 63 51 61 61 61 55 63
RAv = 36 dB(A) RAv = 32 dB(A) RAv = 28 dB(A) RAv = 28 dB(A) RAv = 34 dB(A) RAv = 29 dB(A) RAv = 28 dB(A) RAv = 31 dB(A) RAv = 31 dB(A) RAv = 28 dB(A) RAv = 28 dB(A) RAv = 31 dB(A) RAv = 39 dB(A) RAv = 32 dB(A) RAv = 28 dB(A) RAv = 28 dB(A) RAv = 34 dB(A) RAv = 29 dB(A) RAv = 28 dB(A) RAv = 31 dB(A) RAv = 31 dB(A) RAv = 28 dB(A) RAv = 28 dB(A) RAv = 31 dB(A)
27 23 15 15 23 23 20 21 21 21 15 24 27 23 20 20 23 23 20 21 21 21 20 23
7
Tabel 3: Benodigde (karakteristieke) geluidwering First te Rotterdam (Highrise, laag 22 tot en met 28)
bouwlaag
gevelnr.
bouwlaag 22 tot en met 28
1 2 3 4 5 6 7 8 9 10 11 12
geluidbelasting [dB] (conform MER) 66 62 55 55 62 62 51 62 61 55 55 63
Geluidisolatie Gak benodigd RAv glas in [dB(A)] dB(A) RAv = 35 dB(A) 26 RAv = 31 dB(A) 22 RAv = 28 dB(A) 20 RAv = 28 dB(A) 20 RAv = 31 dB(A) 22 RAv = 31 dB(A) 22 RAv = 28 dB(A) 20 RAv = 31 dB(A) 22 RAv = 30 dB(A) 21 RAv = 28 dB(A) 20 RAv = 28 dB(A) 20 RAv = 31 dB(A) 23
Het glaspercentage van de gevels varieert tussen de ca. 35% en ca. 70%. Uit de tabellen blijkt dat voor gevel 1 de maximale geluidbelasting 70 dB bedraagt. Uitgaande van een maximaal glaspercentage van 70% (meest kritische situatie) is om aan de eis uit het Bouwbesluit te voldoen een RA,wegverkeer voor de beglazing van 31 dB benodigd, zoals ook blijkt uit bijlage 2.1. Uit de tabellen blijkt ook dat in gevel 1 tenminste beglazing met een R A,wegverkeer van 35 dB wordt toegepast. Hiermee wordt voldaan aan de eis uit het Bouwbesluit. Derhalve voldoen geveldelen met een lager glaspercentage of een lagere geluidbelasting ook aan de eis gesteld in het Bouwbesluit. Op de overige gevels is de geluidbelasting maximaal 66 dB (zie tabellen). Ook hier uitgaande van een maximaal glaspercentage van 70% is om aan de eis uit het Bouwbesluit te voldoen een RA,wegverkeer voor de beglazing van 28 dB benodigd, zoals blijkt uit bijlage 2.2. Uit de tabellen blijkt dat voor de overige geveldelen tenminste beglazing met een RA,wegverkeer van 28 dB wordt toegepast. Hiermee wordt voldaan aan de eis uit het Bouwbesluit. Derhalve voldoen geveldelen met een lager glaspercentage of een lagere geluidbelasting ook aan de eis gesteld in het Bouwbesluit.
G 16598-22-RA
8
BIJLAGE I
Nummering van de gevels
De aangegeven geluidisolaties RA,verkeer in dB(A) voor het glas zijn de in de praktijk te realiseren geluidisolaties. De laboratorium geluidisolatiewaarde van het het uiteindelijk te plaatsen glas dient 2 dB(A) hoger te zijn dan de genoemde waarden in de figuur
Gevel 1
Gevel 2 Gevel 4
Gevel 3.2
G 16598-22-RA-BY1
Gevel 3.1
I.1
BIJLAGE I
Nummering van de gevels
Gevel 1 Gevel 2
Gevel 12
Gevel 3
Gevel 11
Gevel 4 Gevel 10
Gevel 5
Gevel 9 Gevel 8
Gevel 6 @ Gevel 7
G 16598-22-RA-BY1
I.2
BIJLAGE II
Berekening Ga,k
G 16598-22-RA-BY2
II.1
G 16598-22-RA project : vertrek :
First fase 1 Plintverdieping (stramien 5,4m)
volume : gevel:
48,6 m3 16,2 m2
deel
code 1 GDL4-12-6 2 MS3 3 4 5 6 7
ventilatie
code 1
omschrijving dubbel glas luchtgevuld spouwmuur ca. 400 kg/m²
persoon: datum:
MJa 25-11-11
spektrum: nagalmtijd:
weg 0,5 oppervlak 11,3 4,9
totaal netto oppervlak gevel:
16,2
Omschrijving
Qeis
bijlage
2.2
s RAv 28,3 51,1
Gpart 26,9 53,3
Cr 3,0 3,0 3,0 3,0 3,0 3,0
Cl 0,0 0,0 0,0 0,0 3,0 0,0
Dn,q
Gpart
Cr
Cl
Geen keuze
3,0
-2,0
Invoer kieren en naden kieren
omschrijving
Lkier
1 KNTO
code
Raam: Niet te openen
24,4
60,0
55,2
3,0
0,0
2 NTG
Kozijn-steen: tweezijdig gekit afdeklat
13,8
55,0
52,7
3,0
0,0
3
3,0
0,0
4
3,0
0,0
Totale geluidwering Karakteristieke geluidwering
Opmerkingen: Rav: geluidisolatie Gpart: partiele karakteristieke geluidwering Cr: correctie term, verschil tussen diffuus geluidveld en invallend geluid. Cl: gevelfactor
Ga Ga;k
-10log kr
Gpart
26,9 26,9
Cr
dB(A) dB(A)
Cl
G 16598-22-RA project : vertrek :
First fase 1 Plintverdieping (stramien 5,4m)
volume : gevel:
48,6 m3 16,2 m2
deel
code 1 GDL6-16-8 2 MS3 3 4 5 6 7
ventilatie
code 1
omschrijving dubbel glas luchtgevuld spouwmuur ca. 400 kg/m²
persoon: datum:
MJa 25-11-11
spektrum: nagalmtijd:
weg 0,5 oppervlak 11,3 4,9
totaal netto oppervlak gevel:
16,2
Omschrijving
Qeis
bijlage
2.1
s RAv 30,8 51,1
Gpart 29,4 53,3
Cr 3,0 3,0 3,0 3,0 3,0 3,0
Cl 0,0 0,0 0,0 0,0 3,0 0,0
Dn,q
Gpart
Cr
Cl
Geen keuze
3,0
-2,0
Invoer kieren en naden kieren
omschrijving
Lkier
1 KNTO
code
Raam: Niet te openen
24,4
60,0
55,2
3,0
0,0
2 NTG
Kozijn-steen: tweezijdig gekit afdeklat
13,8
55,0
52,7
3,0
0,0
3
3,0
0,0
4
3,0
0,0
Totale geluidwering Karakteristieke geluidwering
Opmerkingen: Rav: geluidisolatie Gpart: partiele karakteristieke geluidwering Cr: correctie term, verschil tussen diffuus geluidveld en invallend geluid. Cl: gevelfactor
Ga Ga;k
-10log kr
Gpart
29,3 29,3
Cr
dB(A) dB(A)
Cl