STAVEBNĚ-FYZIKÁLNÍ VLASTNOSTI STAVEBNÍCH OBJEKTU STAVEBNĚ-TECHNICKÉ PARAMETRY STAVEBNÍCH KONSTRUKCÍ ZÁSADNĚ OVLIVŇUJÍ KVALITU VNITŘNÍHO PROSTŘEDÍ Z HLEDISKA ZDRAVÉHO A BEZPEČNÉHO UŽÍVÁNÍ A ZÁROVEŇ URČUJÍ VHODNOST POUŽITÝCH MATERIÁLŮ, SLEDUJÍ I ENERGETICKOU NÁROČNOST PROVÁDĚNÝCH OBJEKTŮ…………
ZÁKLADNÍMI PARAMETRY JSOU:
TEPELNĚ-TECHNICKÉ POŽADAVKY AKUSTICKÉ POŽADAVKY POŽADAVKY NA DENNÍ OSVĚTLENÍ A PROSLUNĚNÍ PROTIPOŽÁRNÍ POŽADAVKY OCHRANA PŘED VLHKOSTÍ
TEPELNĚ-TECHNICKÉ POŽADAVKY PŘI ROZDÍLU TEPLOT MEZI VNITŘNÍM / INTERIÉREM / A VNĚJŠÍM / EXTERIÉREM / PROSTŘEDÍM PROSTUPUJE TEPLO KONSTRUKCÍ / SMĚR PŘIROZENÉHO PROUDĚNÍ JE SMĚREM K CHLADNĚJŠÍMU PROSTŘEDÍ /.
CÍLEM STAVEBNÍHO DÍLA JE VYTVÁŘET TEPELNOU POHODU S MINIMÁLNÍMI NÁKLADY NA VYTÁPĚNÍ A KLIMATIZACI.NOSNÉ STAVEBNÍ KONCTRUKCE Z BETONU,OCELI,KAMENE A PLNÉ KERAMIKY NEMAJÍ DOBRÉ TEPELNĚ- IZOLAČNÍ VLASTNOSTI. KOMBINACE LEHKÝCH – POREZNÍCH TEPELNĚ-IZOLAČNÍCH MATERIÁLŮ S NOSNÝMI ZAJIŠŤUJE POŽADOVANÝ TEPELNÝ ODPOR RN, RESPEKTIVE NORMOVÝ SOUČINITEL PROSTUPU TEPLA UN . U STAVEBNÍCH KONSTUKCÍ ZJIŠŤUJEME VÝPOČTEM RV, UV DÁLE SE VYPOČTE POVRCHOVÁ TEPLOTA tsim , DIFUZNÍ ODPOR, KONDENZACE VODNÍCH PAR………
TEPELNÝ ODPOR VÍCEVRSTVÉ KONSTRUKCE RV Rv = R i +
d1
+
d2
λ1 λ 2
+
d3
λ3
+
di + Re λi
/
m2K/W
Ri = 1
/
Re = 1
αι
SOUČINITEL PROSTUPU TEPLA UV
UV =
1 Rv
αe
/ W/m2K /
NEJNIŽŠÍ POVRCHOVÁ TEPLOTA tsim/ STANOVENÍ ROSNÉHO BODU / STĚNA tsim = tap - U.Ri .( tap - te )
/ θsim = θap - U.Ri.( θap- θe ) / / θsiN ´ = ∆θ w 1 + Δ θ w 2 + θ w /
tsiN ´ = ∆tw1 + ∆tw2 + tw
KOUT tsim = tap – Kx.U.Ri .( tap - te )
/ θsim = θap – Kx.U.Ri.( θap- θe ) / E
I E
E
I
Kx =
0,6 (U .Ri ) 0, 21
Kx =
tsim ≥ tsiN
I
1,05 (U .Ri ) 0,31 www.tzb-info.cz
POŽADOVANÉ A DOPORUČENÉ HODNOTY SOUČINITELE PROSTUPU TEPLA UN PRO BUDOVY S PŘEVAŽUJÍCÍ NÁVRHOVOU VNITŘNÍ TEPLOTOU ti = 20°C
Popis konstrukce
Typ konstrukce
[W/(m2.K)]
Součinitel typu konstrukce e2 [-]
Činitel teplotní redukce b1 [-]
Požadované hodnoty UN
Doporučené hodnoty UN
[W/(m2.K)] Střecha plochá a šikmá se sklonem do 45° včetně Podlaha nad venkovním prostorem Strop pod nevytápěnou půdou se střechou bez tepelné izolace Podlaha a stěna s vytápěním
lehká
0,24
0,16
0,8
1,25
těžká
0,30
0,20
0,8
1,00
Stěna venkovní Střecha strmá se sklonem nad 45°
lehká
0,30
0,20
1,0
1,25
těžká
0,38
0,25
1,0
1,00
Podlaha a stěna přilehlá k zemině (s výjimkou podle poznámky 2) Strop a stěna vnitřní z vytápěného k nevytápěnému prostoru
0,60
0,40
0,8
0,49
Strop a stěna vnitřní z vytápěného k částečně vytápěnému prostoru
0,75
0,50
0,8
0,40
1,05
0,70
0,8
0,29
1,30
0,90
1,0
0,29
Strop vnitřní mezi prostory s rozdílem teplot do 5 °C včetně
2,2
1,45
0,8
0,14
Stěna vnitřní mezi prostory s rozdílem teplot do 5 °C včetně
2,7
1,80
1,0
0,14
nová
1,80
1,20
5,5
1,15
upravená
2,0
1,35
6,0
1,15
3,5
2,3
6,0
0,66
Stěna mezi sousedními budovami Strop mezi prostory s rozdílem teplot do 10 °C včetně Stěna mezi prostory s rozdílem teplot do 10 °C včetně
Okno a jiná výplň otvoru podle 4.6, z vytápěného prostoru (včetně rámu, který má nejvýše 2,0 W/(m2.K))
Dveře, vrata a jiná výplň otvoru podle 4.6, z částečně vytápěného nebo nevytápěného prostoru vytápěné budovy (včetně rámu)
Z HLEDISKA VÝHODNÉ AKUMULACE TEPLA HMOTNÉ NOSNÉ KONSTRUKCE A NÁSLEDNÉMU SÁLÁNÍ TEPLA PŘI PŘERUŠOVANÉM VYTÁPĚNÍ A Z DŮVODU POSUNU ROSNÉHO BODU K EXTERIÉRU SE NAVRHUJÍ TEPELNĚ-IZOLAČNÍ OBKLADY NA STRANĚ EXTERIÉRU. ZNAKY PRO SPRÁVNÉ ZATEPLENÍ HTTP://WWW.ZATEPLENI-KWACZEK.CZ/ZATEPOVACI-SYSTEMY • IZOLUJE TEPLO • ODVÁDÍ VLHKOST • CHRÁNÍ PROTI VNĚJŠÍM VLIVŮM • VZHLED (ESTETICKÝ DOJEM BUDOVY)
ZATEPLOVACÍ SYSTÉM ETICS ETICS = EXTERNAL THERMAL INSULATION COMPOSITE SYSTEM - ANGLICKÁ ZKRATKA, V ČR POUŽÍVÁME ZKRATKU VKZS = VNĚJŠÍ KONTAKTNÍ ZATEPLOVACÍ SYSTÉM, NEBO TAKÉ VNĚJŠÍ KONTAKTNÍ TEPELNĚ IZOLAČNÍ KOMPOZITNÍ ZATEPLOVACÍ SYSTÉM. JEDNÁ SE O CELKOVÉ POKYNY, JAK PROKÁZATELNĚ SNÍŽIT SPOTŘEBU ENERGIÍ A UŠETŘIT FINANCE. ZATEPLOVACÍ SYSTÉMY DRUHY: • KONTAKTNÍ ZATEPLOVACÍ SYSTÉMY - PŘEVÁŽNĚ SE ZATEPLUJE BUDOVA ZVENČÍ, OBSAHUJE KONTAKT IZOLANTU A ZDI • BEZKONTAKTNÍ / NEKONTAKTNÍ ZATEPLOVACÍ SYSTÉMY - JEDNÁ SE O ZATEPLENÍ, KTERÉ OBSAHUJE K ODVĚTRÁVÁNÍ VZDUCHOVOU MEZERU (= ODVĚTRÁVANÁ FASÁDA)
KONTAKTNÍ SYSTÉM ZATEPLENÍ
BEZKONTAKTNÍ SYSTÉM ZAPLENÍ
PRŮKAZ ENERGETICKÉ NÁROČNOSTI BUDOVY (PENB) SLOUŽÍ K INFORMACI O ENERGETICKÉ NÁROČNOSTI PROVOZU NEMOVITOSTI. PRŮKAZ ENERGETICKÉ NÁROČNOSTI BUDOVY JE SOUČÁSTÍ ENERGETICKÉHO POSUDKU. ENERGETICKÝ POSUDEK (EP) JE ROZBOREM NEMOVITOSTI Z HLEDISKA HOSPODAŘENÍ S ENERGIEMI, VČETNĚ PŘEDBĚŽNÉHO NÁVRHU STAVEBNÍCH OPATŘENÍ, JEJICH CENÁCH A DOPADU. HTTP://WWW.PRUKAZNADUM.CZ/PRUKAZ-ENERGETICKE-NAROCNOSTI
AKUSTICKÉ POŽADAVKY ZVUK VZNIKÁ MECHANICKÝM KMITÁNÍM MOLEKUL. RUŠIVÝ ZVUK JE HLUK. VE STAVEBNICTVÍ SE ZABÝVÁME ŠÍŘENÍM ZVUKU VZDUCHEM A HMOTAMI / KONSTRUKCÍ /. ÚKOLEM STAVEBNÍ AKUSTIKY JE NAVRHOVAT PROSTŘEDÍ, VE KTERÉM JE DOBRÁ LIBOZVUČNOST A SLYŠITELNOST / TZV. OPTIMÁLNÍ DOBA DOZVUKU / - BEZ NEGATIVNÍHO VLIVU PROSTUPU ZVUKU Z OBALUJÍCÍCH KONSTRUKCÍ A OKOLNÍHO PROSTŘEDÍ. VZDUCHOVÁ NEPRŮZVUČNOST V dB ZVUKOVÁ NEPRŮZVUČNOST – KROČEJOVÁ NEPRŮZVUČNOST / HLUK ZPŮSOBENÝ NÁRAZY A CHŮZÍ PO PODLAZE /
PRÁH BOLESTI 130 dB
PRÁH SLYŠITELNOSTI 0 dB
TĚŽKÉ NOSNÉ STĚNY MAJÍ VZDUCHOVOU NEPRŮZVUČNOST DOBROU . PŘÍČKY O MENŠÍ TLOUŠTCE / 100-150 MM / PŘI POŽADAVKU NA AKUSTICKOU ZÁBRANU KOMBUNUJEME S MATERIÁLEM ZVUKOVĚ POHLTIVÝM . POHLTIVÝMI MATERIÁLY – AKUSTICKÝMI OBKLADY OVLIVŇUJEME OPTIMÁLNI DOZVUK.
AKUSTICKOU KVALITU PROSTORU ROVNĚŽ OVLIVŇUJE TVAROVÁNÍ PROSTORU, VELIKOST MÍSTNOSTÍ, AKUSTICKÉ PODHLEDY I VYBAVENÍ NÁBYTKEM. V RÁMCI ZVUKOVÉ IZOLACE OPOMENOUT NEBEZPEČÍ REZONANCE / KMITAJÍCÍ KONSTRUKCE JE ZDROJEM ZVUKU /, JEJÍŽ PŘÍČINOU MOHOU BÝT STROJE NEBO RÁZY VZNIKAJÍCÍ V POTRUBÍ. ŘEŠENÍM JE ODDĚLENÍ ZDROJE OD KONSTRUKCE TZV. IZOLÁTORY CHVĚNÍ NAPŘ. U STROJNÍHO VYBAVENÍ BUDOV.
KROČEJOVÁ NEPRŮZVUČNOST: TJ. NEPRŮZVUČNOST KONSTRUKCE PROTI HLUKU VZNIKAJÍCÍMU CHŮZÍ NEBO RÁZY, NEZÁVISÍ NA PLOŠNÉ HMOTNOSTI, NÝBRŽ NA PŘERUŠENÍ VEDENÍ ZVUKU HMOTOU. DOCILUJE SE ODDĚLENÍM PODLAHY OD STROPNÍ KONSTRUKCE VRSTVOU ZE ZVUKOVĚ IZOLAČNÍHO MATERIÁLU, KTERÉ ŠPATNĚ VEDOU ZVUK A TLUMÍ KMITÁNÍ KONSTRUKCE. ZVUKOVÉ IZOLAČNÍ VRSTVA MÁ ODDĚLOVAT PODLAHU I OD OSTATNÍCH KONSTRUKCÍ, NAPŘ. OD STĚN A PŘÍČEK, TAKŽE VYTVÁŘÍ TZV. IZOLAČNÍ VANU. PODLAHY V NÍ ULOŽENÉ SE PROTO NAZÝVAJÍ "PLOVOUCÍ PODLAHY". PODLE ULOŽENÍ NA NOSNOU KONSTRUKCI ROZEZNÁVÁME PODLAHY: • POLOPRUŽNÉ / TĚŽKÉ + LEHKÉ / PLOVOUCÍ PODLAHY: U NICHŽ JE NÁŠLAPNÁ VRSTVA ULOŽENA NA POLOTUHÉ ZVUKOVĚIZOLAČNÍ VRSTVĚ, PŘIČEMŽ SE NEPOŽADUJE OBVODOVÁ IZOLACE NÁŠLAPNÉ VRSTVY, ZLEPŠUJE HLAVNĚ KROČEJOVOU NEPRŮZVUČNOST; POUŽÍVÁ SE PRO STROPY O HMOTNOSTI 330 AŽ 350 KGM-2
•
PODLAHOVÉ POVLAKY: JSOU VYTVOŘENY NÁŠLAPNOU VRSTVOU (NAPŘ. Z PVC NEBO TEXTILNÍ PODLAHOVINY) ULOŽENOU POUZE NA TLUMÍCÍ PODLOŽCE (NAPŘ. Z PLSTI, Z MECHOVÉ PRYŽE, Z GUMY APOD.). TATO JEDNOVRSTVÁ PODLAHA TLUMÍ POUZE KROČEJOVÝ HLUK; MÁ SE POUŽÍVAT PRO STROPNÍ KONSTRUKCE O HMOTNOSTI NAD 350KGM-2
POŽADAVKY NA DENNÍ OSVĚTLENÍ A PROSLUNĚNÍ DLE NORMY ČSN 73 0580-1 DENNÍ OSVĚTLENÍ BUDOV MUSÍ BÝT VŠECHNY BYTY V ČR NAVRHOVÁNY TAK, ABY BYLY DOSTATEČNĚ PROSLUNĚNY. BYT JE PROSLUNĚNÝ, JE-LI SOUČET PODLAHOVÝCH PLOCH JEHO PROSLUNĚNÝCH OBYTNÝCH MÍSTNOSTÍ ROVEN NEJMÉNĚ 1/3 PODLAHOVÝCH PLOCH VŠECH JEHO OBYTNÝCH MÍSTNOSTÍ./DO SOUČTU PLOCH NEZAPOČÍTÁVÁME ČÁSTI PODLAHOVÝCH PLOCH MÍSTNOSTÍ, KTERÉ LEŽÍ ZA HRANICÍ HLOUBKY ROVNÉ 2,3 NÁSOBKU JEJÍ SVĚTLÉ VÝŠKY/. PROSLUNĚNÁ MÍSTNOST MUSÍ SPLŇOVAT PODMÍNKY: PŮDORYSNÝ ÚHEL SLUNEČNÍCH PAPRSKŮ S HLAVNÍ PŘÍMKOU ROVINY OKENNÍHO OTVORU MUSÍ BÝT NEJMÉNĚ 25° A VÝŠKA SLUNCE NAD NEJMÉNĚ 5°. OTVORY, KTERÝMI PROCHÁZÍ SLUNEČNÍ ZÁŘENÍ DO MÍSTNOSTI MUSÍ BÝT PROSKLENY PRŮHLEDNÝM A BARVY NEZKRESLESLUJÍCÍM MATERIÁLEM. CELKOVÁ PLOCHA OKEN SE MUSÍ ROVNAT NEJMÉNĚ 1/10 PODLAHOVÉ PLOCHY MÍSTNOSTI / OPTIMÁLNĚ 1/8 /,ZA NEJMENŠÍ ROZMĚR OKNA JE POVAŽOVÁN OTVOR 900X900 MM. MÍSTNOST MÁ BÝT VE DNECH 1. BŘEZNA A 21. ČERVNA PŘI JASNÉ OBLOZE PROSLUNĚNA MINIMÁLNĚ 90 MINUT.
PROSVĚTLENÍ OVLIVŇUJE UMÍSTĚNÍ A PLOCHA OKEN
VNITŘNÍ PROSTOR BY MĚL BÝT NAVRŽEN A KONCIPOVÁNTAK,ABY UMOŽŇOVAL DOBRÝ KONTAKT S VENKOVNÍM PROSTŘEDÍM. PRO POHODU ČLOVĚKA JE DŮLEŽITÝ POHLED Z OKNA. JEHO PROSTŘEDNICTVÍM SE INFORMUJE O DENNÍ A ROČNÍ DOBĚ A POČASÍ VENKU. VNÍMÁ CYKLICKÉ ZMĚNY DENNÍHO SVĚTLA, KTERÉ PŘÍZNIVĚ PŮSOBÍ NA JEHO BIOLOGICKÉ RYTMY. http://www.tzb-info.cz/3945-denni-osvetleni-a-prosluneni-bytovych-domu http://www.izolace.cz/index.asp?module=ActiveWeb&page=WebPage&DocumentID=2599
PROTIPOŽÁRNÍ POŽADAVKY
www.tzb-info.cz/pozarni-bezpecnost-staveb
POŽÁRNÍ BEZPEČNOST BUDOV OBECNĚ JE POSTAVENA NA DVOU ZÁKLADNÍ PILÍŘÍCH, KTERÝMI JSOU PASIVNÍ A AKTIVNÍ POŽÁRNÍ OCHRANA. PASIVNÍ POŽÁRNÍ OCHRANA PŘEDSTAVUJE KONSTRUKČNÍ A DISPOZIČNÍ ŘEŠENÍ STAVBY Z POŽÁRNÍHO HLEDISKA ČLENĚNÍ OBJEKTU DO POŽÁRNÍCH ÚSEKŮ, POUŽITÍ VYHOVUJÍCÍCH VÝROBKŮ, HMOT A STAVEBNÍCH KONSTRUKCÍ Z HLEDISKA JEJICH HOŘLAVOSTI A POŽÁRNÍ ODOLNOSTI, ŘEŠENÍ ÚNIKOVÝCH CEST PRO OSOBY ČI EVAKUAČNÍCH CEST PRO ZVÍŘATA, VYBAVENÍ ZÁSAHOVÝCH CEST PRO JEDNOTKY POŽÁRNÍ OCHRANY, ZHODNOCENÍ POŽÁRNĚ NEBEZPEČNÉHO PROSTORU APOD. - INSTALACE BLESKOSVODU /HROMOSVODU / – AKTIVNÍ NEBO PASIVNÍ AKTIVNÍ POŽÁRNÍ OCHRANA PŘEDSTAVUJE SCHOPNOST POŽÁRNĚ BEZPEČNOSTNÍCH ZAŘÍZENÍ JAKO CELKU V BUDOVĚ DETEKOVAT ÚČINKY POŽÁRU, V LOGICKÝCH NÁVAZNOSTECH OVLÁDAT OSTATNÍ POŽÁRNĚ BEZPEČNOSTNÍ ZAŘÍZENÍ A LIKVIDOVAT (PŘÍPADNĚ SNIŽOVAT) ÚČINEK VZNIKAJÍCÍHO POŽÁRU, TJ. V JEHO POČÁTEČNÍ FÁZI. JEDNÁ SE ZEJMÉNA O ELEKTRICKOU POŽÁRNÍ SIGNALIZACI, STABILNÍ HASICÍ ZAŘÍZENÍ, ZAŘÍZENÍ PRO ODVODY KOUŘE A TEPLA, POŽÁRNÍ VĚTRÁNÍ ÚNIKOVÝCH CEST, ZAŘÍZENÍ PRO AUTONOMNÍ DETEKCI A SIGNALIZACI POŽÁRU A MNOHO DALŠÍCH ZAŘÍZENÍ. POŽÁRNÍ ÚSEKY (PÚ) ABY SE MINIMALIZOVAL ROZSAH ŠKOD ZPŮSOBENÝCH POŽÁREM, DĚLÍ SE OBJEKTY DO POŽÁRNÍCH ÚSEKŮ (PÚ). POŽÁRNÍ ÚSEK JE PROSTOR V OBJEKTU, KTERÝ JE OD OSTATNÍCH PROSTOR ODDĚLEN POŽÁRNĚ DĚLICÍMI KONSTRUKCEMI (TEDY KONSTRUKCEMI S POŽÁRNÍ ODOLNOSTÍ, AŤ JIŽ NOSNÝMI NEBO NENOSNÝMI). ROZDĚLENÍ UVNITŘ POŽÁRNÍHO ÚSEKU PAK VE VĚTŠINĚ PŘÍPADŮ NENÍ PŘEDMĚTEM POŽÁRNÍ BEZPEČNOSTI. EXISTUJÍ PROVOZY, KTERÉ BEZ OHLEDU NA PŮDORYSNÉ ROZMĚRY NEBO POČET PODLAŽÍ MUSÍ TVOŘIT SAMOSTATNÝ PÚ. CELKOVÝ VÝPIS TAKOVÝCH PROVOZŮ JE UVEDEN V ČLÁNKU 5.3.2 ČSN 73 0802, NEJČASTĚJI SE V OBJEKTECH VYSKYTUJÍ TYTO: • CHRÁNĚNÁ ÚNIKOVÁ CESTA; • VÝTAHOVÁ A INSTALAČNÍ ŠACHTA PROCHÁZEJÍCÍ PŘES RŮZNÉ POŽÁRNÍ ÚSEKY; STROJOVNA VÝTAHU; • KAŽDÁ OBYTNÁ NEBO UBYTOVACÍ BUŇKA (BYT, RODINNÝ DŮM, HOTELOVÝ POKOJ); • GARÁŽ (S VÝJIMKOU GARÁŽE U RODINNÉHO DOMU, KTERÁ MŮŽE BÝT OBVYKLE SOUČÁSTÍ JEHO POŽÁRNÍHO ÚSEKU); • KOTELNA S VELKÝM TOPNÝM VÝKONEM; • PROVOZY ZAJIŠŤUJÍCÍ POŽÁRNÍ BEZPEČNOST STAVEB, NEJČASTĚJI STROJOVNY POŽÁRNĚ BEZPEČNOSTNÍCH ZAŘÍZENÍ (STROJOVNA STABILNÍHO HASICÍHO ZAŘÍZENÍ, POŽÁRNÍHO VĚTRÁNÍ CHRÁNĚNÝCH ÚNIKOVÝCH CEST, ZAŘÍZENÍ PRO ODVOD KOUŘE A TEPLA) A JEJICH NAPÁJENÍ (MÍSTNOST PRO NÁHRADNÍ ZDROJ ELEKTRICKÉ ENERGIE).
DRUHY KONSTRUKČNÍCH SYSTÉMŮ BUDOV NA ZÁKLADĚ UMÍSTĚNÍ KONSTRUKČNÍCH ČÁSTÍ DRUHU DP1, DP2 A DP3 V POŽÁRNĚ DĚLÍCÍCH A NOSNÝCH KONSTRUKCÍCH ZAJIŠŤUJÍCÍCH STABILITU OBJEKTU NEBO JEHO ČÁSTÍ JE DEFINOVÁN KONSTRUKČNÍ SYSTÉM OBJEKTU Z POŽÁRNÍHO HLEDISKA .
DOBA POŽÁRNÍ ODOLNOSTI / PO / PO DOBU POŽÁRNÍ ODOLNOSTI MUSÍ KONSTRUKCE ODOLÁVAT ÚČINKŮM POŽÁRU, RESPEKTIVE MUSÍ PLNIT POŽADOVANÝ MEZNÍ STAV (POPŘÍPADĚ VÍCE MEZNÍCH STAVŮ). DOBA POŽÁRNÍ ODOLNOSTI JE MĚŘENA V MINUTÁCH, PŘIČEMŽ JE VYTVOŘENA STUPNICE. ZÁKLADNÍ KLASIFIKAČNÍ DOBY JSOU 15, 30, 45, 60, 90, 120 A 180 MINUT.
MEZNÍ STAVY POŽÁRNÍ ODOLNOSTI MEZNÍ STAV POŽÁRNÍ ODOLNOSTI ZOHLEDŇUJE TYP KONSTRUKCE: ZDA JE NOSNÝ ČI NENOSNÝ, ZDA JDE O STĚNU, SLOUP, POPŘ. DVEŘE. NORMA ČSN EN 13501-2 DEFINUJE ŘADU MEZNÍCH STAVŮ, ČTYŘMI NEJČASTĚJI POUŽÍVANÝMI JSOU: R, E, I, W (OBRÁZEK 6). U VÝPLNÍ OTVORŮ SE LZE SETKAT SE DVĚMA DALŠÍMI SPECIFICKÝMI MEZNÍMI STAVY C A S
HLAVNÍ MEZNÍ STAVY: (a) R = ÚNOSNOST A STABILITA, (b) E = CELISTVOST, (c) I = IZOLAČNÍ SCHOPNOST (OMEZENÍ TEPLOTY); (d) W = OMEZENÍ RADIACE (SÁLÁNÍ) TEPLA
ZVYŠOVÁNÍ POŽÁRNÍ ODOLNOSTI PŘI NÁVRHU NOVÉ BUDOVY NENÍ VĚTŠINOU PROBLÉM KONSTRUKCE NAVRHNOUT, ABY SPLŇOVALY POŽADAVKY POŽÁRNÍ ODOLNOSTI. U REKONSTRUKCÍ STÁVAJÍCÍCH BUDOV, KDY SE ZVYŠUJE POŽÁRNÍ ZATÍŽENÍ, NEBO U SPECIFICKÝCH KONSTRUKCÍ (NAPŘ. OCELOVÝ ČI DŘEVĚNÝ SKELET) UŽ POŽÁRNÍ ODOLNOST BEZ DALŠÍCH OPATŘENÍ NEMUSÍ BÝT SPLNITELNÁ. PAK JE POTŘEBA KONSTRUKCI NĚJAK UPRAVIT, RESPEKTIVE NĚČÍM „ZAKRÝT“ TAK, ABY SE CHRÁNĚNÁ KONSTRUKCE ZAČALA ZAHŘÍVAT POMALEJI. MOŽNOSTÍ JE NĚKOLIK, ZÁLEŽÍ NA PROSTORU OKOLO CHRÁNĚNÉHO PRVKU, NA EXPOZICI, NA POŽADAVKU ESTETICKÉ FUNKCE, NA UMÍSTĚNÍ CHRÁNĚNÉHO PRVKU V BUDOVĚ, NA ZÁKLADNÍ POŽÁRNÍ ODOLNOSTI NECHRÁNĚNÉHO PRVKU A V NEPOSLEDNÍ ŘADĚ NA ŽIVOTNOSTI OCHRANNÉHO SYSTÉMU.
MOŽNOSTMI ZVYŠOVÁNÍ POŽÁRNÍ ODOLNOSTI JSOU: • OBETONOVÁNÍ NEBO OBEZDĚNÍ; TOTO ŘEŠENÍ JE CELKEM TRVANLIVÉ, ALE TAKÉ PROSTOROVĚ NÁROČNÉ A HMOTNÉ – JE POTŘEBA I NĚKOLIKA CM, ABY TOTO OPATŘENÍ MĚLO ŽÁDANÝ EFEKT. • POŽÁRNÍ OMÍTKY; JEDEN Z TRADIČNÍCH SYSTÉMŮ OCHRANY, OPĚT JE VŠAK POTŘEBA ZHOTOVIT OMÍTKU V TLOUŠŤCE NĚKOLIKA CM. NEJVÝHODNĚJŠÍ Z HLEDISKA POŽÁRNÍ OCHRANY JSOU OMÍTKY SÁDROPERLITOVÉ NEBO SÁDROVERMIKULITOVÉ, NAOPAK NEJBĚŽNĚJŠÍ VÁPENNÉ, VÁPENOCEMENTOVÉ NEBO CEMENTOVÉ OMÍTKY MAJÍ Z POŽÁRNÍHO HLEDISKA MINIMÁLNÍ ÚČINEK. PRO LEPŠÍ SOUDRŽNOST A PŘÍDRŽNOST KE CHRÁNĚNÉMU PRVKU SE OCHRANNÉ OMÍTKY MOHOU VYZTUŽOVAT PLETIVEM NEBO MINERÁLNÍMI VLÁKNY. • POŽÁRNÍ NÁSTŘIKY JSOU DALŠÍM VÝVOJOVÝM STUPNĚM POŽÁRNÍCH OMÍTEK. STEJNĚ JAKO U OMÍTEK SE DO SILIKÁTOVÉ BÁZE PŘIDÁVAJÍ DALŠÍ SPECIFICKÁ PLNIVA (VERMIKULIT, PERLIT) A VÝZTUŽ. NANÁŠENÍ NÁSTŘIKŮ JE VŠAK RYCHLEJŠÍ. OMÍTKY I NÁSTŘIKY JSOU TRVANLIVÉ, NA DRUHOU STRANU STÁLE HMOTNÉ A NA CHRÁNĚNÉM PRVKU VYTVÁŘÍ HRUBOU NEESTETICKOU STRUKTURU. PO ZASCHNUTÍ JSOU NAVÍC KŘEHKÉ, TAKŽE U DYNAMICKY ZATÍŽENÝCH KONSTRUKCÍ (NAPŘ. TRIBUNY) MOHOU PRASKAT. • POŽÁRNÍ OBKLADY A PODHLEDY JSOU TRVANLIVÉ. LZE POUŽÍT MATERIÁLY DESKOVÉ, AŤ JIŽ HOMOGENNÍ (NAPŘ. VÁPENOSILIKÁTOVÉ, VERMIKULITOVÉ), NEHOMOGENNÍ (NAPŘ. CEMENTOTŘÍSKOVÉ), POPŘÍPADĚ DESKY SENDVIČOVÉ (NAPŘ. SÁDROKARTONOVÉ, SÁDROVLÁKNITÉ), NEBO LZE POUŽÍT OBJEMNĚJŠÍ OBKLAD Z MINERÁLNÍCH VLÁKEN. • POŽÁRNÍ NÁTĚRY SE OPROTI PŘEDCHOZÍM ÚPRAVÁM VYZNAČUJÍ SUBTILNOSTÍ, DÍKY KTERÉ SI MOHOU KONSTRUKČNÍ PRVKY ZACHOVÁVAT SVŮJ PŮVODNÍ TVAR, A MOŽNOSTÍ LIBOVOLNÉHO BAREVNÉHO ŘEŠENÍ (VČETNĚ BEZBARVÉHO ZEJMÉNA PRO DŘEVĚNÉ KONSTRUKCE). VÝRAZNOU NEVÝHODOU POŽÁRNÍCH NÁTĚRŮ JE JEJICH OMEZENÁ ŽIVOTNOST (OBVYKLE OKOLO 10 LET), PO JEJÍŽ UPLYNUTÍ JE NEZBYTNÁ OBNOVA NÁTĚROVÉHO SYSTÉMU, A ROVNĚŽ OMEZENÁ POUŽITELNOST, KDY NÁTĚRY NELZE VŮBEC POUŽÍT. EXISTUJÍ NÁSLEDUJÍCÍ TYPY POŽÁRNÍCH NÁTĚRŮ: O INTUMESCENTNÍ NÁTĚRY JSOU Z HLEDISKA POUŽITÍ UNIVERZÁLNÍ A POUŽÍVÁNY JSOU NEJČASTĚJI, A TO ZEJMÉNA PRO OCELOVÉ, DŘEVĚNÉ, ALE I BETONOVÉ KONSTRUKCE. PŘI TEPELNÉ EXPOZICI NÁTĚR NAPĚNÍ AŽ NA 50NÁSOBEK SVÉ PŮVODNÍ TLOUŠŤKY. NA POVRCHU CHRÁNĚNÉ KONSTRUKCE VYTVÁŘÍ MASIVNÍ TEPELNĚIZOLAČNÍ BARIÉRU (PĚNU), KTERÁ ZPOMALUJE OHŘÍVÁNÍ CHRÁNĚNÉHO PRVKU A ZAMEZUJE PŘÍSTUPU KYSLÍKU. VELKOU POZORNOST JE TŘEBA VĚNOVAT SPRÁVNÉ APLIKACI INTUMESCENTNÍHO NÁTĚRU, TJ. ZEJMÉNA KOMPATIBILNOSTI JEDNOTLIVÝCH VRSTEV NÁTĚROVÉHO SYSTÉMU (VRSTVA ZÁKLADNÍ, FUNKČNÍ A KRYCÍ) A SKUTEČNOSTI, ABY NAPĚNĚNÍ NEBYLO BRÁNĚNO ŽÁDNOU DALŠÍ PŘEKÁŽKOU (NAPŘ. DODATEČNÝM OBKLADEM, NÁBYTKEM APOD.). O ZÁBRANOVÉ NÁTĚRY SE POUŽÍVAJÍ ZEJMÉNA NA KABELY A PLASTOVÉ VÝROBKY. PŘI TEPELNÉ EXPOZICI VYTVOŘÍ NA CHRÁNĚNÉM PRVKU NEPRODYŠNOU KRUSTU, ČÍMŽ SE OMEZÍ PŘÍSTUP KYSLÍKU A ZABRÁNÍ SE PROCESU HOŘENÍ. O SUBLIMUJÍCÍ NÁTĚRY SE POUŽÍVAJÍ VÝJIMEČNĚ A VÝHRADNĚ NA OCELOVÝCH KONSTRUKCÍCH. PŘI TEPELNÉ EXPOZICI SE Z NÁTĚRU UVOLŇUJÍ PLYNY, KTERÉ STRHUJÍ PLAMEN A OCHLAZUJÍ KONSTRUKCI.
OCHRANA PŘED VLHKOSTÍ